HomeMy WebLinkAboutNOA - EXHAUST VENT FOR ROOF RIDGESP11AFI1•DIE
Ml9MI-DADE COUNTY
PRODUCT CONTROL SECTION
- - - DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) l l805 SW 26-Sfrcd. loom 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
GAF
I Campus Drive
Parsippany, NT. 07054
SCOPE: ------------ - -------- -----------------
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if.it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
.DESCRIPTION: GAF Cobra® Exhaust Vent for Roof Ridge.
LABELING: Each unit, shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dada County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
Z ERNIINATION o£tbis NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA,
ADVERTISE
1VIENT: The NOA number preceded by the words Miami -Dade Coulnty, Florida, and followed
by the expiration date may be displayed in advertising literate e. H any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 1 &0619.02 and consists of pages 1 through 3. _
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No. 194123.05
), Expiration Date: 11/09/23
Approval Date: 05/16/19
Page 1 of 3
1
ROOFING COMPONENT APPROVAL
Category: Roofing _
- —
Sub-Catetsory: Ventilation
Materials:. Plastic
1 `RADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT:
Test Product
Product Dimensions Spccrficaiiou
I) _ €scrratxon
GAF Cobra°-EWaust Vent 3/4" x 10 1/2" x 20' TAS-7 00 Low xofic n le attic 'dge vent for installationstainstallation
for Roof Ridge
.rr�r �.uvra-s:xnausr Vent
for Roof Ridge
(For nail guns)
EVIDENCE SUSMPPTED:
1. Acworth, GA.
EVIDENCE SUBMITTED:
Test A2ency/Identifier
Intertek - Architectural Testing
Intertek
MfAFII•DAUE CbUNTY
n
Low profile attic ridge vent for installation
ender ridaa .chinalA�
Name Re ort Date
TAS 100(A) 13223.01409-18 06/06/18
ASTMD 1929 13223,02-106-18 RI 07/20/18
ASTM D 635 I3223.02-166-18 RI 07/20/18
ASTMD 2843 13223 6024064 8 R1 07/20/18
ASTMD 1929 J0478.01406-18 RO 01/08/19
ASTM D 635 J0478.01406-18 RO 01/08/19
ASTMD 2843 10478.0140648 RO 01/08/19
NOA No.19-0123.05
Expirafaon Date: 11/09/23
Approval Date: 05/16/19
Page 2 of 3
-- - -APPROVED APPLICATIONS - - -- -- - — - - - - -
Tradename: GAF Cobra® Exhaust Vent for Roof Ridge
System Type: Mechanical attachment of static vent over asphalt shingle roof systems only.
Cutout: Cut a 2" slot along the ridge of the roof by nutting 1 " on each side of the ridge. Leave uncut
sheathing area of 6" at each end of the ridge. Cut through sheathing only, avoiding roof trusses.
--- — -- -- In buildings with a ridge board,.cut 1-3/4" slot on each side.'
Installation: Roll out ridge vent centered over the slot, and secured 6" o.c. on each side of the ridge with
included 2-1/2" corrosion resistant galvanized roofing nails or 1-3/4" collated corrosion resistant
to hold it in place until ridge shingles can be installed.
galvanized roofing nails (for nail guns)
(Polyurethane sealant shall be used to seal the perimeter of the vent to the roof shingles.) Extend
to the rake edge• Roll ends or cut joints shall be butted together and caulked with an approved
polyurethane sealant.
Ridge Shingle: Install pre -manufactured or field -cut ridge shingles over the ridge vent in compliance with the
shingle manufacturer's Notice of Acceptance (NOA) and the installation instructions.
Ring shank nails shall be corrosion resistant and long enough to penetrate through the•wood deck
a minimum of 3/16". Apply a bead of polyurethane sealant in between adjacent cap shingles to
seal the caps.
Net Free Area: Refer to manufachuexs published literature.
LIMITATIONS:
1. Refer to applicable building codes for required ventilation.
2. This acceptance is for installations over asphalt shingle roof systems 3. only.
GAF Cobra® Exhaust Vent for Roof Ridge shall not be installed on roof mean heights greater than 33 feet.
4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer`s name or logo, city and state and following statement: "Miami Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
IAMitiR1]$ CO I�jTY-
END OF THIS ACCEPTANCE
M�A67FIYADE COUNTY
NOA No. 19-0123.05
Expiration Date: 11/09/23
Approval Date: 05/16/19
Page 3 of 3