HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS12%14/2I,'J:57 AM Florida Building Code Online
BCIS Home I Log In I User Registatlon � Hot Topics submit Surcharge I Stats & Fac[s Publications ( Contact Us aCIS 51[e Map Links Search
Floridd
Product Approval
R', USER: PUbit User
Ih�� 1 i
ro(' duct Approval Menu > Pratluct or ApPlicatlon Search > 9pplicatlon List > AppUca[lon Detail
FL # FL10626-R22
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived �:'..1
Product Manufacturer GAF
Address/Phone/Email 1 Campus Drive
Parisppany, NJ 07054
(800)766-3411
mstieh@gaf.com
Authorized Signature Robert Nleminen
Irelth@nemoetacom
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054
(800)766-3411
Tech n i calQuestionsGAF@g af. com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
(.l Evaluation Report -Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/17/2021
Validated By John W. Knezevich, PE
-:�� Validation Checklist -Hardcopy Received
Certificate of Independence FL10626 R22 COI 2021 Ol COI NIEMINEN. pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D4533 (tear) 2015
ASTM D4798 (weathering) 2011
ASTM D4869 (water transmission) 2016
ASTM D5035 (tensile) 2011
ASTM D6164 2011
ASTM D6757 2016
FM 4474 2011
FRSA/TRI, 6th Edition 2018
https:/ifioridabuilding.org/pr/pr_app_dtLaspx?param=wGEVXQwIDgtBNbEYSV%26oQY9nVE2RiJEIVOxKjvNQ3GJL9ejWU2ta%26EAg3d%3d I/2
12/14l21, 7:57 AM
florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
06/09/2021
Date
Validated
06/il/2021
Date
Pending FBC Approval
06/17/2021
Date
Approved
08/10/2021
Summary of Products
rI
FL #
Model, Number or Name
Description
10626.1
GAF Roof Underlayments far
RooOng Underlayments for use
In sloped roof systems
use In FBC non-HVHZ
jurisdidlons
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10626 R22 II 2021 06 09
FINAL ER 6AF UNDERLAYMENTS FL10626-
}222.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By; Robert Niemien 59166
Design Pressure: +N/A/-442.5
Created by Independent Third
Party: Yes
Other: 1,) The design pressure noted in this
Evaluation Reports
application relates to one particular
FL10626 R22 AE 2021 06 09
FINAL ER GAF UNDERLAYMENTS FLS0626-
underlayment system. Refer to ER Section 6, 8,3
R22.pdf
for details. 2.) Refer to ER Section 6 for other
Created by Independent Third
Party: Yes
Limits of Use.
onext
ContaQ Us :: 2601 Blair Stone Roatl Tallahassee FL 32399 Phone 650-48]-162
The State of Florida is an AA/EEO employer. CopLrl ht 200]-2013 St F f FI Ida :: Privacy Statement :: Accessibility Statement :: Refuntl Statement
Under Florida law, email addresses are public records. If you tlo not want your a -mall address released In response to apublic-records request, tlo not send elec[ronk
mail to this entity. Instead, contact [he ofnce by phone or by tradltlonal mall. tf you have any questions, please contact 850.99].1395. (Pursuant [o seQlon 455.2]6(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide [he Department with an email atltlress If they have one. The emalls
provltletl may be used for oHlclal communicatlon with the Ilcensee. However email addresses are public record. If you tlo not wish to supply a personal atldress, please
provitle the Department with an email address which can be made available to the public. To determine If you are a Ilcensee under Chapter 455, F.S., please click )_iem .
Protluct Approval Accepts:
Credit Card
Safe
https:!/(loridabuilding.org/pr/pr_app_dtLaspx4param=wGEVXQwtDqtBNbEYSV%26oQY9nVE2RUHVOxKjvNQ3G1L9ejWUj2ta%26EA%3d%3d 2/2
NEMO l etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(N (203)262-9245
ENGINEER EVALUATE TEST CONSULT
GAF Evaluation Report 01506.04.08-R22
1Campus Drive FL10626-R22
Parsippany, NJ 07054 Date of Issuance: 04/25/2008
(800) 766-3411 Revision 22: 06/09/2021
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted
herein.
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507#1111
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
is distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
��aP'GfV'e3�G �
• - t9e
%2�-6'ri•:E, was au y
2 ',°,c'_ nsoi.;";; The facsimile seal appearing authorized b Robert
,� �yat0�a Nieminen,E. on d document.
This does not serve as an
electronically signe
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
'4NEM0 I etc.
ROOFING COMPONENT EVALUATION:
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement: GAF
Roof Underlayments, as produced by
GAF, have demonstrated
compliance with the
following sections of the 7t6 Edition (2020) Florida Building Code through
testing in accordance
with the following
Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions
of Use set forth
herein.
r•r
Section
Proper
Standard
Year
1504.3A
Wind resistance
FM 4474
2011
1507.1.1, 1507.2.41 1507.2.9.2 /
Material standard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.1.1.1(2&3, Exception),
Tear Strength
ASTM D4533
2015
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(2&3, Exception),
Tensile strength
ASTM D5035
2011
1507.1.1.1(5) / R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
1507.1.1.1(5)/ R905.1.1.1(5)
Liquid water transmission
ASTM D4869
2016
1507.1.1 / R905.1.1
Material standard
ASTM D6757
2016
1507.3.3, R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2
Material standard
ASTM D6164
2011
TAS 110
Accelerated Weathering
ASTM D4798
2011
Examination
Reference
Date
Entity
ERD (TST 6049)
ASTM D1623 & FRSA/TRI (Slippage)
G34150.08.11
11/14/2011
ERD (TST 6049)
ASTM D6164 (GA)
G40630.01.14-2B
01/07/2014
ERD (TST 6049)
ASTM D6164 (GA)
G46160.09.14-3A
09/09/2014
END (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-3
03/01/2017
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-4
03/01/2017
ERD (TST 6049)
ASTM D1970 (GA)
GAF-SC13285.03.17-1
03/08/2017
ERD (TST6049)
ASTM D1970 (IN)
GAF-SC16440.12.17
12/31/2017
Intertek(TST 1558)
ASTM D4869(Dadra, India)
F8549.02-106-18
11/08/2016
N EMO (TST 6049)
Physical Properties (ON)
4q-GAF-I9-SSMBB-03.A
05/13/2019
NEMO (TST6049)
ASTM D1970
4j-FTS-20-SSUDL-01.A
12/01/2020
NEMO (TST 6049)
ASTM D4798, TAS 103
4j-GAF-20-SSUDL-02.A
03/15/2021
NEMO (TST6049)
ASTM D4798
4j-FTS-2I-SSUDL-02.A
06/09/2021
PRI (TST 5878)
ASTM D1970 (IN)
GAF-324-02-01
11/30/2011
PRI (TST 5878)
ASTM D226 (OK)
GAF-339-02-01
03/13/2012
PRI (TST 5878)
ASTM D4798 INC)
GAF-349-02-01
07/03/2012
PRI (TST 5878)
Wind Uplift
GAF-434-02-01
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434-02-03
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434-02-04
09/16/2013
PRI (TST 5878)
ASTM D4533 (various)
GAF-818-02-01
12/05/2017
PRI (TST 5878)
ASTM D1970 (AL)
MSA-047-02-01
04/11/2018
PRI (TST 5878)
ASTM D4533 (LA)
GAF-826-02-01
06/4/2018
PRI (TST 5878)
ASTM D4533 (Dadra, India)
GAF-847-02-01
06/4/2018
PRI (TST 5878)
ASTM D4533 (Dadra, India)
GAF-914-02-01
04/10/2019
PRI (TST 5878)
ASTM D4533, D5035 (VA)
376TOO12
07/15/2019
PRI (TST 5878)
ASTM D4533 (Umerkui Kilvani, India)
376TOO18
07/31/2019
PRI (TST 5878)
ASTM D4533 (Parzai, India)
376TOO18
07/31/2019
NEMO ETC, LLC Evaluation Report 01606.04.06-1122
Certf(Icote of Authorization #32455 7r"EDITION (2020)FeC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22: O6/09/2021
Page 2 of 9
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4,10
4.11
4.12
Entity
Examination
PRI
(TST 5878)
ASTM D1970 (AR)
PRI
(TST 5878)
ASTM D226 (S-CA)
PRI
(TST 5878)
ASTM D4533 (Gujarat, India)
PRI
(TST 5878)
ASTM D5035 (various)
PRI
(TST 5878)
ASTM D4533, D5035 (Rajasthan, India)
PRI
(TST 5878)
ASTM D4533, D5035 (Gujarat, India)
UL
(TST 1740)
ASTM D6757 (TX)
PRI
(TST 5878)
ASTM D5035 (Gujarat, India)
PRI
(TST 5878)
ASTM D4533, D5035 (Rajasthan, India)
UL(TST
1740)
ASTM D6757(NC)
N EMO ETC
Traceability
N EMO
Traceability
UL,
LLC (QUA 9625)
Quality Control
UL,
LLC (QUA 9625)
Quality Control
UL,
LLC (QUA 9625)
Quality Control
fONEMOJetc.
Reference
Date
376T0032
10/22/2019
376T0054
02/18/2020
376T0058
02/18/2020
376T0103
09/11/2020
376T0111
12/22/2020
376T0113
12/22/2020
02N K22569
06/04/2002
376T0146
03/11/2021
376T0161
05/07/2021
lON K11990
05/18/2011
FBC Cross -Listing
04/22/2020
FBC Cross -Listing
04/08/2021
Service Confirmation
03/23/2021
Service Confirmation (AL)
05/04/2020
Florida BCIS
Current
Product
Material Standard
Plant(s)
GAF Extended Dry -In Membrane
ASTM D1970
Langley, BC Canada
UbertyTM SBS Self -Adhering Base/Ply
Mt. Vernon, IN
Sheet
ASTM D1970
Savannah, GA
Mt. Vernon,
StormGuard® Film -Surfaced Leak Barrier
ASTM D1970
Savannah, CA
Arkadelphia, AR
WeatherWatch® Mineral -Surfaced Leak
Mt. Vernon, IN
Barrier
ASTM D1970
Savannah, GA
Tuscaloosa, AL
Deck -Armor" Premium Breathable Roof
1507.1.1.1(2&3, Exception) /
Dadra, India
Deck Protection
R905.1.1.1(2&3, Exception)
Dadra, India
FeltBuster'" Synthetic Roofing Felt
1507.1.1.1(2&3, Exception),
Gujarat, India
(CPP) Rajasthan, India
(formerly Fel[Buster'" High -Traction Synthetic
1507.1.1.1(5) / R905.1.1.1(2&31
(MIP) Rajasthan, India
Roofing Felt)
Exception), R905.1.1.1(5)
Richmond, VA
Spartanburg, SC
Pryor,
Shingle -Mate® Roof Deck Protection
ASTM D226, Type II (Table 1)
Shaffer, CA
StormSafe"" Anchor Sheet
1507.1.1.1(2&3, Exception) /
North Bay, ON
R905.1.1.1(2&3, Exception)
Dadra, India
Tiger Paw'" Premium Roof Deck
Exception)
Protection/formerly Tiger Pow'^' Roof Deck
R07.1.1.1(2&3,
R905.1.1.1(2&3, Exception)
Parzalt,India
Parzai, India
Protection)
Umerkui Kilvanl, India
VersaShield® Fire -Resistant Roof Deck
ASTM D6757
Conover, NC
Protection
ASTM D6164
Ruberoid® Map Granule
Savannah, GA
FRSA/TRI 09-18
ASTM D6164
Ruberoid® Mop Granule FR
Savannah, GA
FRSA/TRI 09-18
NEMO ETC, LLC Evaluation Report 01606.04.08-R22
Certificate ofAutharfzation a32455 7TMEDITION (2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22: O6/09/2021
Page 3 of 9
,4NEMO I etc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (Le,, Broward and Miami -
Dade Counties),
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5A This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FSCSection:
1507.2
15oza
1507.4 and 1507.5
1507.7
1507.8 and 1507.9
Clay and Concrete Tile
Metal
Slate or
Wood
Underlayment
Asphalt
Selate-Type
Mechanical
Ad
Shingles
Setve-
Panels
Shingles
Shingles
Shingles
Shakes
hcal
Yes
Yes
GAF Extended Dry -in Membrane
Yes
No
No
Yes
Yes
Yes
Uoint:trip.,
Umnt:trips,
1507.1.1.3 /
1507.1.1.3 /
R905.1.1.3)
R905.1.1.3)
Yes
Yes
LibertyT"SBS Self -Adhering
Yes
No
No
No
No
No
(joint:nip:,
Uouitsmp.,
Base/Ply Sheet
1507.1.1.3/
1507.1.1.3/
R905.1.1.3)
R9D5.1.1.3)
Yes
Yes
StormGuard®Film-Surfaced Leak
Yes
No
No
Yes
Yes
Yes
UDlnl stops,
(joint strips,
Barrier
1507.1.1.3/
1507.1.1.3/
R905.1.1.3)
ft9 5.1.1.3)
Yes
Yes
WeatherWatch®Mineral-Surfaced
Yes
No
No
No
No
No
Uoint.trip,,
Uolnt snip:,
Leak Barrier
507.1.1.3/
1507.1.1.3/
R905.1.1.3)
R905.1.1.3)
Deck-Armorl" Premium Breathable
Yes
No
No
Yes
Yes
Yes
No
No
Roof Deck Protection
FeltBusterT" Synthetic RaoOng Felt
Yes
No
No
No
No
No
No
No
Shingle -Mate® Roof Deck
Yes
No
No
No
No
No
No
No
Protection
Tiger Paw`" Premium Roof Deck
Yes
No
No
Yes
Yes
Yes
No
No
Protection
VersaShield® Fire -Resistant Roof
Yes
No
No
No
No
No
No
No
Deck Protection
Yes
Yes
Ruberoid®Mop Granule
No
(Cap sheet in
(Cap Sheet in
No
No
No
No
No
2-ply system)
2 -ply system)
See 5.6.1
Yes
Yes
Ruberoid®Mop Granule FR
No
(Cap sheet in
Sheet in
(ply
No
No
No
No
No
system)
2-ply system)
See 5.6.1
NEMO ETC, LLC Evaluation Report 03506.04.08-R22
Certificate af4u[horizatlon #32455 7r"EDITION (2020)FBC NON-HVH2 EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22: 06/09/2021
Page 4 of 9
ONEMOjetc.
5.6.1 Adhesive -set is limited to use of following
underlayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE UNDERIAYMENT / TILE -ADHESIVE COMBINATIONS'
Underlayment
Adhesive
Florida Product Approval
Ruberoid® Mop Granule; Ruberoid® Mop Granule FR
Dupont "Tile Bond'" Roof Tile Adhesive'
FL22525
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERU\YMENTS
Underlayment
Application
Primer
Substrates
GAF Extended Dry -In Membrane
self -adhering
None
plywood
Liberty'" SBS Self -Adhering Base/Ply Sheet
self -adhering
(Optional)
ASTM D41
plywood
StormGuard® Film -Surfaced Leak Barrier
Weather Watch® Mineral -Surfaced Leak Barrier
Liberty'" SBS Self -Adhering Base/Ply Sheet
self -adhering
None
ASTM D226 felt, Type it
StormGuard® Film -Surfaced Leak Barrier
Weather Watch• Mineral -Surfaced Leak Barrier
Liberty'" SBS Self -Adhering Base/Ply Sheet
self -adhering
ASTM D41
metal (flashing metal, valley metal,
etc.)
StormGuard® Film -Surfaced Leak Barrier
Weather Watch® Mineral -Surfaced Leak Barrier
Ruberoid® Mop Granule
hot asphalt
ASTM D41
structural concrete
Ruberoid® Mop Granule FR
Ruberoid® Mop Granule
Ruberoid® Mop Granule FR
hot asphalt
None
GAFGLAS® #80 Ultima'" Base Sheet
or Ruberoidm 20 Smooth
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets -not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but —for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1 (for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
' Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance
NEMO ETC, LLC Evaluation Report 01506.04.08-R22
CertlP�nte of Authorization #32455 7'"EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22: 06/09/2021
Page 5 of 9
ONEMO I etc.
#1 Maximum Design Pressure = -442.5 psf.
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction
Base Sheet: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4,
Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20
to 25 Ibs/square.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square,
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section
2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements.
#2 Maximum Design Pressure = -45 psf
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'"' Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c.
at the min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid®Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#3 Maximum Design Pressure = -75 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'm Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c.
at the min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows
in the field of the sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure = -97.5 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 UltimaTm Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga.,
min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c.
at the min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field
of the sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
NE VIO ETC, LLC Evaluation Report 01506.04.08-R22
Certificate of Auuthorization#32455 7T"EDITION(2020)FaC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22: 06/09/2021
Page 6 of 9
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS '
Underlayment
Prepared Roof Cover
Maximum
Exposure
Installation Type
(days)
Deck -Armor" Premium Breathable Roof Deck Protection, FeItBusteCSynthetic
Roofing Felt, Shingle -Mate® Roof Deck Protection, StormSafe'" Anchor Sheet, Tiger
Paw'" Premium Roof Deck Protection, VersaShieldm Fire -Resistant Roof Deck
Mechanically attached
30
Protection, Liberty'" SBS Self -Adhering Base/Ply Sheet, StormGuardo Film -Surfaced
Leak Barrier and WeatherWatch® Mineral -Surfaced Leak Barrier
GAF Extended Dry -In Membrane
Mechanically attached
180
Ruberoid® Mop Granule and Ruberoid° Mop Granule FR
Adhesive -set the roof system
180
Mechanically attached
UNLIMITED
5.10 Tile Slippa¢e
Limitations: When
loading
roof tiles on the underlayment in direct -deck the
roof assemblies, the
maximum
roof slope shall be as
follows.
These slope limitations can only be exceeded by
using battens during
loading
of the roof tiles.
TABLE 4; TILE SLIPPAGE LIMITATIONS FORDIRECT-DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum Staging Slope
Ruberoid® Mop Granule
Flat
Max. 10-tile stack
4:12
Flat
Max. 6-tile stack (4 over 2)
5:12
Lugged
Max. 10-tile stack
5:12
Ruberoid® Mop Granule FR
Flat or Lugged
Max. 6-tile stack (4 over 2)
5:12
Lugged
Max. 10-tile stack
4:12
6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application and prime the substrate (if applicable).
6.3.1 Shall be installed incompliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception)
or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type
of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.4 FeltBuster'" Synthetic Roofing Felt:
6.4.1 Shall be installed in compliance with requirements for a synthetic underlaymentin FBC 1507.1.1.1(2, Exception),
1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
NEMO ETC, LLC Evaluation Report 01506.Oq.08-R22
Gertificote fAuthorizottan a32455 7'"EDITION i2020)FBC NON-HVHZ EVALUATION FL10626-R22
GAF Roof Underlayments Revision 22: O6/09/2021
Page 7 of 9
4NEMO I etc.
6.5.1 StormSafeT'" Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems.
6,5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception)
or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type
of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take
precedence over the manufacturer's installation instructions.
6.5.3 One the same day, install LibertyTM SBS Self -Adhering Base/Ply; StormGuard® Film -Surfaced Leak Barrier or
WeatherWatch® Mineral -Surfaced Leak Barrier over the StormSafe"" Anchor Sheet.
6.6 Shingle -Mate® Roof Deck Protection;
6.6.1 Shall be installed in mnlinn�n , k ...,.,,..
- -��- -•�rr���=v���=���a�n�m�yauacneaunaerlayment(AS IM
D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions.
6.7
VersaShield®Fire-Resistant Roof
Deck
Protection:
6-7.1
Ch Pll ho inef�Hl A :..
.
----- ---•r••••••�� ^•l•• •�yull=Iljmm� Ful do approve0 mecnamcaliy attached underlayment (ASTM
D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be
installed, and the manufacturer's installation instructions. FBC requirements take precedence over the
manufacturer's installation instructions. Im
GAF Extended Dry -In Membrane, Liberty c SBS Leak
Barrier:
An Base/Ply Sheet, StormGuard® Film -Surfaced Leak:.
Barrier or WeatherWatch® Mineral -Surfaced Leak Barrier•
6.8.1 Shall be installed in comnlinnrP ui fh P .� a.. _..
_. i 1115 ui iuci myn ien L iHJ I IVI U17 /Ui In
FBC 1507.1.1,1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
6.8.2 Back -nailing is required. Back -nailing shall consist of Approved cap nails spaced 18-inch ox., encapsulated within
min. 4-inch side laps.
6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type it felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.8.4 GAF Extended Dry -In Membrane, Liberty"m SBS Self -Adhering Base/Ply Sheet, StormGuardO Film -Surfaced Leak
Barrier or WeatherWatch® Mineral -Surfaced Leak Barrier may be installed as a secondary water barrier using
minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
6.9.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the
ETwo Ply System' in the rers installation
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition, and the manufacturer's installation instructions.
6.9.2 Refer to Section 5.8 herein for attachment limitations.
6.9.3 Refer to Table 4 for tile staging limitations.
NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certfi�ote fAuthonzation #32455 7T�EDITION 120201 FBC NON-HVHZ EVALUATION FL10626-R22
GAF Raof Underlayments Revision 22: O6/09/2021
Page 8 of 9
4MEMO I etc.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL, LLC.—QUA9625; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC
cert�cote fAuthorizotian #32455 Evaluation Report 01506.04.08-R22
Jr"EDITION (2020( FBC NON-HVHZ EVALUATION
GAF Roof Underlayments fL10626-R22
Revision 22: O6/09/2021
Page 9 of 9