Loading...
HomeMy WebLinkAboutUNDERLAYMENTS NOA1/12l22; 3:52 PM Florida Building Code Online Florida -m I�" �ProductApproval R USER: Public User �d�n 31Po'/mi Product Approval Menu > Produ4 or Appllcatlon Search > 9PPIICdtIOn List > ApplicaUon Oetall FL # FL10626-R22 Appllcatlon Type Revision Code Version 2020 Application Status Approved Comments Archived ( ) Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, N7 07054 (800)766-3411 mstleh@gaf.com Authorized Signature Robert Nieminen Ireith@nemoetc. com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07064 (800) 766-3411 Tech nica IQuestl onsGAF@gaf. com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer fl Evaluation Report -Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nleminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated By John W. Knezevlch, PE t�'--! Validation Checklist -Hardcopy Received Certlflcate of Independence EL10626 R22 COI 2021 Ol COI NIEMINEN Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D4633 (tear) 2015 ASTM D4798 (weathering) 2011 ASTM D4869 (water transmission) 2016 ASTM D5035 (tensile) 2011 ASTM D6164 2011 ASTM D6767 2016 FM 4474 2011 FRSA/TRI, 6th Edition 2018 https://floridabuilding.org/pr/pr_app_d[Laspx7param=wGEVXQwtDgtBNbEY5V�2boQY9nVE2RiJHVOx<CjvNQ3G7L9ejWUj2ta9o26EA%3d�3d 1/2 1/12/22, 3:52 PM Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method i Option D Date Submitted 06/09/2021 Date Validated 06/il/2021 Date Pending FBC Approval 06/17/2021 Date Approved OS/10/2021 Date Revised 1Z/16/2021 Summary of Products FL # Model, Number or Name Description 10626.1 GAF Roof Underlayments for I Roofing Underlayments for use in sloped roof systems use in FBC non-HVHZ jurisdictions Limits of Use Installation Instructions Approved for use in HVHZ: No FL10626 R22 II 2021 06 09 FINAL ER GAF UNDERLAYMENTS FL10626- Approved for use outside HVHZ: Yes R22.ILdf Impact Resistant: N/A VerlFled By: Robert Nlemien 69166 Design Pressure: +N/A/-442,5 Created by Independent Third Party: Yes Other: 1.) The design pressure noted In this Evaluation Reports application relates to one particular FL10626 R22 AE 2021 06 09 FINAL ER GAF UNDERLAYMENTS_FL10626-. underlayment system. Refer to ER Section 6. B.3 R22.pdf for details. 2.) Refer to ER Section 6 for other Created by Independent Third Party: Yes Limits of Use. Bacit Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 860-487-182 The State of Flonda Is an AA/EEO employer. Copyright 200]-2013 State of Fior"da :: Privacy Statement:: Accessibility Statement :: Refuntl Statement Untler Florltla law, email addesses are public records. If you do not want your a -mall atldress released In response to a public -records request, tlo not send electronic mall to this entlty. instead, contact the office by phone or by tratlitlonai mall. If you have any questions, please contact 860.48].1396, 'Pursuant to SeQlon 466.2]B(Il, Florltla Statutes, effective October 1, 2012, licensees il<ensed antler Chapter 456, F.S. must provide the Department with an email adtlress If they have one. Ttie emalls provltled may be usetl for ofOcial communication with the licensee. However email addresses are public record. If you do not wish to supply a personal atldress, please prpvitle [he Department wI[h an email address which can be matle available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here , Produc[Approval Acceptr: ® Kok �� - � Sl'CUI'll\ \l l.'I'Ii1Cti https://ftotidabuilding.org/pr/pr_app_d[1.aspx?param=wGEVXQwtDq[BNbEYSV%26oQY9nVE2RUHVOxKjvNQ3GJL9ejWUj2ta%2bEA%a3d%3d 2/2 NEMO l etc. Certificate of Authorization N32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT 1Campus Drive Parsippany, NJ 07054 (800) 766-3411 FL10626-R22 Date oflssuance:04/26/2008 Revision 22: 06/09/2021 $COPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 71h Edition (2020) Florida Building Code sections noted herein. LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle, ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Ietc, Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection atthe job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robertl.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seals I authorized Robert appearing y •,Fy.,,.r..`�,.:+�'�? This Nieminen,P.E. on O6/09/2021. This does not serve as an ,�N im",� electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved In the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC ROOFING COMPONENT EVALUATION: 1. JCDYE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the 711 Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth Section Pro er Standard Year 1504.3.1 Wind resistance FM 4474 2011 1507.1.1, 1507.2.40 1507.2.9.2 / Material standard ASTM D1970 2015 R905.1,11 R905.2.8.2 1507.1.1.1(2&3, Exception), Tear Strength ASTM D4533 2015 1507.1.1.1(5) / 11905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), Tensile strength ASTM D5035 2011 1507.1.1.1(5) / R905.1.1.1(2&31 Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1507.1.1/ R905.1.1 Material standard ASTM D6757 2016 1507,3.31 R905.3.3 Material standard FRSA/TRi, Sixth Edition 2018 1507,11.2 Material standard ASTM D6164 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 Entity Examination Reference Date ERD (TST 6049) ASTM D1623 & FRSA/TRI (Slippage) G34150.08.11 11/14/2011 ERD (TST 6049) ASTM D6164 (GA) G40630.01.14-28 01/07/2014 ERD (TST 6049) ASTM D6164(GA) G46160.09.14-3A 09/09/2014 ERD (TST 6049) ASTM D1970 (GA) GAF-SC13285.03.17-3 03/01/2017 ERD (TST 6049) ASTM D1970 (GA) GAF-SC13285.03.17-4 03/01/2017 ERD (TST 6049) ASTM D1970 (GA) GAF-SC13285.03.17-1 03/08/2017 ERD (TST6049) ASTM D1970 (IN) GAF-SC16440.12.17 12/31/2017 ntertek(TST 1558) ASTM D4869(Dadra, India) F8549.02-106-18 11/08/2016 NEMO (TST 6049) Physical Properties (ON) 4q-GAF-I9-SSMBB-03.A 05/13/2019 NEMO (TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/2020 NEMO (TST 6049) ASTM D4798, TAS 103 4j-GAF-20-SSUDL-02.A 03/15/2021 NEMO (TST6049) ASTM D4798 4j-FTS-2I-SSUDL-02.A 06/09/2021 PRI (TST 5878) ASTM D1970 (IN) GAF-324-02-01 11/30/2011 PRI (TST 5878) ASTM D226 (OK) GAF-339-02-01 03/13/2012 PRI (TST 5878) ASTM D4798 (NC) GAF-349-02-01 07/03/2012 PRI (TST 5878) Wind Uplift GAF-434-02-01 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-03 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-04 09/16/2013 PRI (TST 5878) ASTM D4533 (various) GAF-818-02-01 12/05/2017 PRI (TST 5878) ASTM D1970 (AL) MSA-047-02-01 04/11/2018 PRI (TST 5878) ASTM D4533 (LA) GAF-826-02-01 06/4/2018 PRI (TST 5878) ASTM D4533 (Dadra, India) GAF-847-02-01 06/4/2018 PRI (TST 5878) ASTM D4533 (Dadra, India) GAF-914-02-01 04/10/2019 PRI (TST 5878) ASTM D4533, D5035 (VA) 376T0012 07/15/2019 PRI (TST 5878) ASTM D4533 (Umerkui Kilvani, India) 376T0018 07/31/2019 PRI (TST5878) ASTM D4533 (Parzai, India) 376T0018 07/31/2019 NEMO ETC, LLC Evaluation Report 01606.09.08-R22 Certificate oJAuthorlmtian H32455 lie EDITION (2020) FBC NON-HVHZ EVALUATION FL30626-1122 GAF Roof Underlayments Revision 22: 06/09/2021 Page 2 of 9 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4,10 4,11 4,12 Entitv Examination PRI (TST 5878) ASTM D1970 (AR) PRI (TST 5878) - ASTM D226 (S-CA) PRI (TST 5878) ASTM D4533 (Gujarat, India) PRI (TST 5878) ASTM D5035 (various) PRI (TST 5878) ASTM D4533, D5035 (Rajasthan, India) PRI (TST 5878) ASTM D4533, D5035 (Gujarat, India) UL (TST 1740) ASTM D6757 (TX) PRI (TST 5878) ASTM D5035 (Gujarat, India) PRI (TST 5878) ASTM D4533, D5035 (Rajasthan, India) UL (TST 1740) ASTM D6757 INC) NEMO ETC Traceability N EMO Traceability UL, LLC(QUA 9625) Quality Control UL, LLC(QUA 9625) Qua lity Control UL, LLC (QUA 9625) Quality Control NE Ao I etc. Reference Date 376T0032 10/22/2019 376T0054 02/18/2020 376T0058 02/18/2020 376T0103 09/11/2020 376T0111 12/22/2020 376T01.13 12/22/2020 02NK22569 06/04/2002 376T0146 03/11/2021 376T0161 OS/07/2021 10NK11990 05/18/2011 FBC Cross -Listing 04/22/2020 FBC Cross -Listing 04/08/2021 Service Confirmation 03/23/2021 Service Confirmation (AL) 05/04/2020 Florida BCIS Current PRODUCTDESCRIPTION: , II GAT Extended / 1 1Langley, BC Canada LibertyTm SBS Self -Adhering Base/Ply l�� Mt. Vernon, IN Sheet • 1 Savannah, GA • t Vernon, •` Arkadelphia,1 WeatherWatchO Mineral -Surfaced Leak Mt. Vernon, IN Barrier / 1 Savannah, GA Tuscaloosa, IIII r, • ���� R90 /.. Dadra, FeltBuster'm Synthetic Roofing Felt 7,1,1.1(2&3, Exception), Gujarat, India 1507.1.1.1(5) •1 5,1.1,1(2&3 (CPP) Rajasthan, India Roofing Felt) Exception), Richmond, VA nbur: Shingle -Mate" Roof 1-ck Protection / II I• or• II Shafter, CA 'i StormSarfe'� Anchor Sheet / Dadra,I India Tiger Paw� Premium Roof 1- 1507.1JA(2&3, Exception)/ Gujarat, IndiaProtection fformerly Tiger PawTTT Roof Deck R905.1,1.1(2&3, Exception) Parzai, India Protection) 1 Umerkul Klivani, India VersaShleldO Fire -Resistant Roof Deck /. �© Protection II Ruberoldg Mop Granule � I09 18 Savannah, GA 1: I: NEMO ETC, LLC Evaluation Repor[ 01506.04.08-R22 Certj<cate o(Aurhorizotlon #3�455 7'"EDITION (2020)FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: O6/09/2021 Page 3 of 9 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5A This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1i ROOF COVER OPTIONS FBC Section: 1507.2 1507.3 1507.4 and 1507.5 1507.7 1507.8 and 1507.9 Clay and Concrete Tile Metal Slate or Wood Underlayment Asphalt Slate -Type Mechanical Adhesive- Shingles Panels Shingles Shingles Shingles Shakes Attach Set Yes Yes GAF Wended Dry -in Membrane Yes No No Yes Yes Yes (Joint strips, Romt strips, 1507.1.1.3 / 1507.1.1.3 / R905.1.1.3) R905.1.1.3) Yes Yes Libertr SBS Self -Adhering Yes No No No No No 0omtsmps, Bomcarips, Base/Ply Sheet 1507.1.1s/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Yes Yes StormGuard® Film -Surfaced Leak Yes No No Yes Yes Yes Rotntorlps, golnt strips, Barrier 1507.1.1.3/ 1507.1.3.3/ R905.1.1.3) R905.1.1.3) Yes Yes WeatherWatch®Mineral-Surfaced Yes No No No No No (pint strips, Domt strips, Leak Barrier 1507.11.31 IS07.1.1.3 / R905.1.1.3) R905.1.1.3) Deck-Armor"Premium Breathable Yes No No Yes Yes Yes No No Roof Deck Protection FeltBusterTM Synthetic Roofing Felt Yes No No No No No No No shingle -Mate® Roof Deck Yes No No No No No No No Protection Tiger Paw' Premium Roof Deck Yes No No Yes Yes Yes No No Protection Versashield°Fire-Resistant Roof Yes No No No No No No No Deck Protection Yes Yes Ruberoid®Mop Granule No (cap Sheet in (Cap sheet in No No No No No 2-piysystem) 2-piysystem) See 5.6.1 Yes Yes Ruberoid®Mop Granule FR No (Cap sheet in (Cap Sheet In No No No No No system) 2-ply system) see 5.6.1 NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certflcate ofAefharizatlon g32455 7TM EDITION (20201 FBC NON-HVH2 EVALUATION FL30626-R22 GAF Roof Underlayments Revision 22: O6/09/2021 Page 4 of 9 • 5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations. TABLE IA: ALLOWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval Ruberoid° Mop Granule; Ruberoida Mop Granule FR Dupont "Tile Bond To Roof Tile Adhesive' FL22525 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Primer Substrates GAF Extended Dry -In Membrane self -adhering None plywood Liberty"' SBS Self -Adhering Base/Ply Sheet self -adhering (Optional) ASTM D41 plywood StormGuard® Film -Surfaced Leak Barrier Weather Watch® Mineral -Surfaced Leak Barrier LibertyT"' SBS Self -Adhering Base/Ply Sheet self -adhering None ASTM D226 felt, Type II StormGuard° Film -Surfaced Leak Barrier Weather Watch® Mineral -Surfaced Leak Barrier Liberty'" SBS Self -Adhering Base/Ply Sheet self -adhering ASTM D41 metal (flashing metal, valley metal, etc.) StormGuard® Film -Surfaced Leak Barrier Weather Watch° Mineral -Surfaced Leak Barrier Ruberoid® Mop Granule hot asphalt ASTM D41 structural concrete Ruberoid® Mop Granule FR Ruberoid° Mop Granule hot asphalt None GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid° 20 Smooth Ruberoida Mop Granule FR 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturers installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but— for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(forTwo-Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A. Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. � Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization#32455 7Ta EDITION(2020)FBC NON-HVH2 EVALUATION F1.30626-1322 GAF Roof Underlayments Revision 22: 06/09/2021 Page 5 of 9 ONEMOletc. #1 Maximum Design Pressure=-442.5 psf. Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction Base Sheet: GAFGLAS #75 Base Sheet, Tri-Piy #75 Base Sheet, GAFGLAS #80 Ultimo Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 lbs/square. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square, 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117, Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #2 Maximum Design Pressure = -45 psf Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaT"' Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. #3 Maximum Design Pressure=-75 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. #4 Maximum Design Pressure =-97.5 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaT'" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25lbs/square. NEMO ETC, LLC Evaluation Report 03606.04.08-R22 Certificate oJAutherizatlan #32455 lTe EDITION (2020) FBC NON-HVH2 EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: O6/09/2021 Page 6 of 9 5.9 Exposure Limitations: TABLE 3:. EXPOSURE LIMITATIONS Prepared Roof Cover Maximum Underlayment Installation Type Exposure (days) Deck -Armor TM Premium Breathable Roof Deck Protection, FeltBuster" Synthetic Roofing Felt, Shingle -Mate® Roof Deck Protection, StornnSafeT" Anchor Sheet, Tiger Pawl Premium Roof Deck Protection, VersaShield® Fire -Resistant Roof Deck Mechanically attached 30 Protection, LibertyT"' SBS Self -Adhering Base/Ply Sheet, StormGuardo Film -Surfaced Leak Barrier and WeatherWatch° Mineral -Surfaced Leak Barrier GAF Extended Dry -In Membrane Mechanically attached 180 Adhesive -set tile roof system 180 Ruberoid° Mop Granule and Ruberoida Mop Granule FR Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck the roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECKTILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Staging Slope Ruberoid® Mop Granule Flat Max. 10-tile stack 4:12 Flat Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 5:12 Ruberoid® Mop Granule FR Flat or Lugged Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 4:12 6A GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate (if applicable). 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in fBC 1507.1.1.1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.4 FeltBuster'"' Synthetic Roofing Felt: 6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate ofAuthorizatfon k32Q55 7r"EDITION (2020)fBC NON-HVHZ EVALUATION FL30626-R22 GAF Roof Underlayments Revision 22: 06/09/2021 Page 7 of 9 4MEMO I etc. 6.5.1 StormSafe"' Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. 6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof coveringto be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5.3 One the same day, install Liberty"" SBS Self -Adhering Base/Ply; StormGuard® Film -Surfaced Leak Barrier or WeatherWatch® Mineral -Surfaced Leak Barrier over the StormSafe"" Anchor Sheet. 6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.7 VersaShield® Fire -Resistant Roof Deck Protection: 6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.8.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. 6.8.2 Back -nailing is required. Back -nailing shall consist of Approved cap nails spaced 18-inch o.c., encapsulated within min. 4-inch side laps. 6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.8.4 GAF Extended Dry -In Membrane, LibertyTm SBS Self -Adhering Base/Ply Sheet, StormGuardO Film -Surfaced Leak Barrier or WeatherWatch® Mineral -Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6.9.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply System' in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. 6.9.2 Refer to Section 5.8 herein for attachment limitations. 6.9.3 Refer to Table 4 for tile staging limitations. NEMO ETC, LLC Evaluation Report 03506.04,08-R22 lertleete o(Authorizotian #32955 7'a EDITION l20201 FBC NON-HVHZ EVALUATION FL30626-R22 GAF Roof Underlayments Revision 22: O6/09/2021 Page 8 of 9 As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements, Refer to Section 4 herein for products and production locations having met codified material standards, UL, LLC.—QUA9626; (414) 248-6409; karen.buchmann@ul.com . END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 01606.04.06-R22 Certificate ojAutharization #32455 7'n EDITION (2020J FOC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: O6/09/2021 Page 9 of 9