HomeMy WebLinkAboutSTRUCTURAL EVALUATION Eng.# 13692727_C2_02
September 10, 2021
Page 1 of 1
AMERICAN TOWER
C O R P O R A T 1 0 N
Structural Evaluation
ATC Site 5120 Reviewed By:
Number& Name Strazzula, FL \\��AI �W�
Carrier Site Number 131783 T /�
& Name STRAZULLA
Site Location 13698 Indrio Rd No 79480
Fort Pierce, FL 34945-4003, St. Lucie County * �
27.5581 N/80.4816 W �
Tower Description 136 ft Guyed
Basic Wind Speed 155 mph (3-second gust) �j� ,� fLop'OP
Applicable Code ANSI/TIA-222-H/2018 IBC/7th ED(2020) Florida Building Code �SSIO�Ak
/it, IIIIi
This item has been electronically signed and sealed by
Evaluation Results: Joshua Walton,PE,CWI on the date shown using digital signature.
The loading in the tables below was evaluated with respect to the tower and foundation Printed copies of this are not considered signed and sealed and the
signature must be verified on any electronic copies.
capacities. As future loading is added,or if actual loading is different from these tables, Digitally signed by Joshua
re-evaluation shall be required. This tower and foundation are adequate to support the Joshua Walton Walton
Date:2021.09.12 22:46:09-0 '00'
below loads in conformance with specified requirements. Created By: lenniferyu
Existing and Reserved Equipment
Elev'(ft) Qty Equipment Mount Type Lines Carrier
3 Ericsson Air6449 B41
132.0 3 Commscope FFVV-65C-R3-V1 Sector Frame (2) 1.99" (50.7mm) SPRINT NEXTEL
3 Ericsson Radio 4480 B71+B85A Hybrid
3 Ericsson Radio 4460 625+666
125.0 6 Andrew DB982G30A-M Sector Frame (10) 1 5/8"Coax VERIZON WIRELESS
102.0 1 Andrew Microwaves UHX6-59W Leg (2) EW52
86.0 1 Ericsson RAU2
85.0 1 Ericsson 1301-UKY 210 77/SC11 Uen Leg (1)3/8" Coax SPRINT NEXTEL
Equipment to be Removed
Elev'(ft) Qty Equipment Mount Type Lines Carrier
125.0 2 CSS X7C-FRO-640 _ (2) 1 5/8" Coax VERIZON WIRELESS
1 CSS X7-665-4
Proposed Equipment
Elev1(ft) Qty Equipment Mount Type Lines Carrier
3 Ericsson Radio 4449- B13&B5
3 Ericsson 8843 Rev 2
125.0 3 Ericsson AIR6449 Sector Frame (2) 15/8" Hybriflex VERIZON WIRELESS
3 Raycap RCMDC-6627-PF-48
6 Commscope NHH-65B-R2B
'Contracted elevations are shown for appurtenances within contracted installation tolerances.Appurtenances outside of contract limits are shown at installed elevations.
Install proposed lines alongside existing VERIZON WIRELESS lines.
ATC Tower Services,Inc. 3500 Regency Parkway,Suite 100-Cary,NC 27518—919-468-0112 Office—919-466-5414 Fax-www.americantower.com