Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Efficiency Code
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Logan Winn Builder Name: Owner Builder Street: 5510 Palmetto Dr Permit Office: St Lucie County City, State, Zip: Fort Pierce, FL, 34982 Permit Number, 211.0325 Owner: Logan Winn Jurisdiction: St Lucie County Design Location: FL, Fort Pierce County: SL Lucie(Florida Climate Zone 2) 1. New construction, or existing New (From Plans) 10. Wall Types(2278.8 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=5.0 1859.80 ftZ b. Frame - Wood, Adjacent R=13.0 419.04, ft2 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 3 d. N/A R= ftZ 5. is this a worst case? No 11. Ceiling Types(1992.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1992.00 ftZ 6. Conditioned floor area above grade (ft2) 1992 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(231.0- sqft.) Description Area 12. DuctsJocation &.insulation level R ft2 a. U-Factor: Dbl, U=0.29 153.00 ft2' a. Sup: Attic, Rot: Attic, AH: Garage 6 235 SHGC: SHGC=0.22 b. b. U-Factor: Dbl, U=0.33 72.00 ft2 C. SHGC: SHGC=0.20 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.28 6.00 ft2 a. Central. Unit 24.4 SEER:16.00 SHGC: SHGC=0.24 Area Weighted Average Overhang Depth: 10.398 ft Area Weighted Average SHGC: 0.214 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 24.4 HSPF:9.00 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): NIA 15. Hot Water Systems 9. Floor Types Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R= 0.0 1990.40 ft2 EF: 0.920 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 16. Credits CF, Pstat Glass/Floor Area: 0.116 Total Proposed Modified'Loads: 55.28 PASS Total Baseline Loads: 61.91 I hereby certify that the plans and specifications covered by this in compliance the Florida Energy Review of the plans and covered by this �t1E 5T ATF calculation are with specifications a4 O.o Code. calculation indicates compliance ti ,, _ ' . gn.�.o_ PREPARED BY: t with the Florida Energy Code.`O Before construction is completed DATE: 118122 this building will be Inspected for compliance with Section 553.908 O -„ Florida Statutes. i hereby certify that this building, as designed, is in compliance �gt15� with the Florida Energy Code. M. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Default duct leakage does not require a Duct Leakage Test Report. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/8/2022 3:16:09 PM EnergyGauge® USA 7.0.00 - FleRes2020 FBC 7th. Edition (2020) Compliant Software Page 1 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT' Title: Logan, Winn Address type: Street Address Building Type:. User Bedrooms: 3 Lot #: - Owner: Logan Winn Conditioned Area: 1992 Biock/SubDivision: - Total Stories: 1 PlatBook: - Builder Name: Owner Builder Worst Case: No Street: 5510 Palmetto Dr Permit Office: St Lucie County Rotate,Angle: 0 County: St. Lucie Jurisdiction: St Lucie County Cross Ventilation: No City, State, Zip: Fort Pierce, Family Type: Detached Whole House Fan: No FL, 34982 New/Existing: New (From Plans) Terrain: Suburban Year Construct 2021 Shielding: Suburban Comment: - CLIMATE Design Temp lht Design Temp Heating Design. Daily temp VDesign Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL,VERO_BEACH MUNICIPA 39 90 70 75 299 - 62 Low BLOCKS Number Name Area Volume 1 Entire House 1992 18725 SPACES Number Name Area Volume Kitchen Occupants Bedrooms finished Cooled Heated 1 hail 21 197.4 No 0 Yes Yes Yes 2 living 390 3750.6 No 1 Yes Yes Yes 3 kitchen 415 3901 Yes -1 Yes Yes Yes 4 bed2 217 2039.8 No 1 1 Yes Yes Yes _ 5 bed3 208 1955.2 No 0 1 Yes Yes Yes 6 bath 59 554.6. No 0 Yes Yes Yes 7 hall1 49 460.6 No 0 No Yes Yes _ _ 8 mbed 264 2481.6 No 1 1 Yes Yes Yes . 9 his 51 479.4 No 0 Yes Yes Yes _ 10 hers r 53 498.2 No 0 Yes Yes Yes 11 mbath 233 2190.2 No 0 Yes Yes Yes 12 we 23 2%.2 No 0 Yes Yes Yes FLOORS (Total Exposed Area. = 1990 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor .Joist R Value Tile Wood Carpet 1 Slab -On -Grade Edge Ins hall 9.3 0 21.3'ft 0.710 - 1.00 0.00 0.00 - 2 Slab -On -Grade Edge Ins living 40.3 0 399.4 ft 0:710 - 1.00' 0.00 0.00 -'3 Slab -On -Grade Edge Ins - kitchen 29.8 0 414.6 ft 0.710 - 1.00 0.00 0.00 4 Slab -On -Grade Edge Ins bed2 30 0 216.5 ft 0.710 - 1.00 0.00 no _ 5 Slab -On -Grade Edge Ins bed3 30 0 207.6 It 0.710 - 1.00 0.00 0.00 _ 6 Slab -On -Grade Edge Ins bath 5.3 0 58.8 ft 0:710 - 1.00 0.00 0.00 7 Slab -On -Grade Edge Ins hall1 1 0 48.8 ft 0.710 - 1.00 0.00. 0.00 _ 8 Slab -On -Grade Edge Ins mbed 32 0 264.4 ft 0.710 - 140 0.00 0.00 _ 9 Slab -On -Grade Edge Ins his 7.5 0 '50.6 ft 0.710 - 1.00 0.00 0.00 r_ 10 Slab -On -Grade Edge Ins hers 7.5 0 52.8 It 0.710 - 1.00 0.00 0.00 11 Slab -On -Grade Edge Ins mbath 44.8 0 232.9 It 0.710 - 1.00 0.00 0.00 _ 12 Slab -On -Grade Edge Ins we 5.8 0 23 ft 0.710 - 1.00 0.00 0.00 1/8/2022 3:16:09 PM EnergyGauge® USA 7.0.00-FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Root Gable Roof Rad Solar SA Emitt Emit[ Deck Pitch ✓# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2100 ft' 0 112 Medium N 0.75 No 0.9 No 20 18.43 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1992 ft2 N N CEILING (Total Exposed Area = 1992 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Free. Truss Type _ 1 Under Atbc(Unvented) hall 0.0 Blown 21.0ft' 0.061 0.10 Wood _ 2 Under Attic(Unvented) living 0.0 Blown 399.0ft' 0.061 0.10 Wood -3 Under Attic(Unvented) kitchen 0.0 Blown 415.0ft' 0.061 0.10 Wood _ 4 Under Attic(Unvented) bed2 0.0 Blown 21.7.0ft2 0.061 0.10 Wood -5 Under Attic(Unvented) bed3 0.0 Blown 208.0ft' 0.061 0.10 Wood -6 Under Attic(Unvented) bath . 0.0 Blown 59.Oft' 0.061 0.10 Wood _ 7 Under Attic(Unvented) halls 0.0 Blown 49.02 0.051 0.10 Wood _ 8 Under Attic(Unvented) mbed 0.0 Blown 264.0ft2 0.061 0.10 Wood 9 UnderAttic(Unvented) his 0.0 Blown 61.0112 0.061 0.10 Wood _ 10 Under Attic(Unvented) hers 0.0 Blown 53.0ft' 0.061 0.10 Wood _ 11 Under Attic(Unvented) mbath 0.0 Blown 233.0ft2 0.061 0.10 Wood 12 Under Attic(Unvented) we 0.0 Blown 23.Oft2 0.061 0.10 Wood WALLS (Total Exposed Area = 2279 sq.ft.) Cavity Width Height Area U- Sheath Frm, Solar Below VAdjacent # Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 W Garage Frame - Wood hall 13.0 5.0 0 9.0 5 47.1 0.095 0 0.25 0.01 0 % __._ 2 N Garage Frame - Wood hell 13.0 4.0 3 9.0 5 40.0 0.095 0 0.25 0.01 0 % 3 W Exterior Cone. Blk - Int Ins living 5.0 22.0 6 9.0 5 211.9 0.132 0 0 0.50 0 % _ 4 N Garage Frame - Wood living 13.0 17.0 9 9.0 5 167.1 0.095 0 0.25 0.01 0 % -5 E Exterior Cone. Blk - Int Ins kitchen 5.0 24.0 9 9.0 5 233.1 0.132 0 0 0.50 0 % -6 N Garage Frame - Wood kitchen 13.0 5.0 0 9.0 5 47.1 0.095 0 0.25 0.01 0 % _ 7 S Exterior Cone. Blk - Int Ins bed2 5.0 13.0 6 9.0 5 127.1 0.132 0 0 0.50 0 % _ 8 W Exterior Cone. Blk - Int Ins bed2 5.0 16.0 6 9.0 5 155.4 0.132 0 0 0.50 0 % -9 E Exterior Cone. Blk - Int Ins bed3 5.0 14.0 3 9.0 5 134.2 0.132 0 0 0.50 0 % _ 10 S Exterior Cone. Blk - Int Ins bed3 5.0 15.0 9 9.0 5 148.3 0.132 0 0 0.50 0 % 11 S Exterior Cone. Blk -int Ins bath 5.0 5.0 3 9.0 5 49.4 0.132 0 0 0.50 0 % _ _ 12 N Exterior Cone. Blk - Int Ins mbed 5.0 13.0 6 9.0 5 127.1 0.132 0 0 0.50 0 % 13 S Exterior Conc. Blk - Int Ins mbed 5.0 6.0 0 9.0 5 56.5 0.132 0 0 0.50 0 % 14 W Garage Frame - Wood mbed 13.0 12.0 6 9.0 5 117.7 0.095 0 0.25 0.01 0 % 15 S Exterior Conc. Blk -'Int Ins his 5,0 7.0 6 9.0 5 70.6 0.132 0 0 0.50 0 % 16 N Exterior Conc. Blk - Int Ins hers 5.0 7.0 6 9.0 5 70.6 0,132 0 0 0.50 0 % 17 N Exterior Conc. Blk - Int Ins mbath 5.0 16.0 6 9.0 5. 155A 0.132 0 0 0.50 0 % 18 E Exterior Conc. Blk - Int ins mbath 5.0 17.0 6 9.0 5 164.8 0.132 0 0 0.50 0 % 19 S Exterior Conc. Blk - Int Ins T mbath 5.0 10.0 9 9.0 5 101.2 0.132 0 0 0.50 0 % 20 S Exterior Conc. Blk - Int Ins we 5.0 5.0 9 9.0 5 54.1 0.132 0 0 0.50 0 % DOORS (Total Exposed Area = 0 sq.ft.) , / V # Ornt Adjacent To Door Type Space Storms U Value Width Height Ft In Ft in Area 1/812022 3:16:09 PM EnergyGauge® USA 7.0.00-FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT DOORS(Continued) WINDOWS (Total Exposed Area = 231 sq.ft.) / Wall Total Same Width Height -Overhang- / # Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Units (ft) (ft) Depth Sep: Interior Shade Screen (#2) (ft) (ft) _ 1 W 3. Vinyl Low-E Double Y 0.33 0.20 Y N 24.0 1 3.00 8.00 12.0 0.5 Drapeslblinds None 2 W 3 Vinyl Low-E Double- Y 0.29 0.22 Y N 15.5 1 3.00 5.17 12.0 0.6 Drapes/blinds Ex. 50% 3 W 3 Vinyl Low-E Double Y '0.29 0.22 Y N 31.0 1 6.00 5.17 12.0 0.5 Drapes/blinds Ex 50% _- 4 E 5 Vinyl 0Low-E Double Y 0.33 0.20 Y N 48.0 1 6.00 8.00 12.0 0.5 Drapes/blinds None _ 5 E 5 Vinyl Low=E Double Y 0.29 0.22 Y N 13.5 1 3.00 4.50 12.0 0.5 Drapes/blinds Ex. 50% 6 W 8 Vinyi Low-E Double Y 0.29 0.22 Y N 31.0 1 6.00 5.17 12.0 0.5 Drapes/blinds Ex. 60% -7 E 9 Vinyl - Low-E Double Y 0.29 0.22 Y N 31.0 1 6.00 5.17 12.0 0.6 Drapes/blinds Ex. 50% 8 N 12 Vinyl Low-E Double Y 0.29 0.22 Y N 31.0 2 3.00 5.17 2.0 1.0 Drapes/blinds Ex. 50% 9 S 20 Vinyl Low-E Double Y 0.28 0.24 Y N &0 1. 3.00 2.00 2.0 1.0 Drapes/blinds Ex. 50% INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00030 1560 85:61 160.72 0.0963 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Will Height, Exposed Wall Insulation 1 621 ft2 621 ft2 64 ft 9 ft 1 MASS # Mass Type Area Thickness Furniture Fraction Space. 1 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 hall 2 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 living .-3 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 kitchen __... 4 Default(8 Ibs/sq.ft.) 0 W 0 ft 0.30 bed2 5 Default(8 Ibs/sq.ft.) 0 ft' 0 It 0.30 bed3 _ 6 Default(8 Ibs/sq.ft.) 0 ft2 ft2 0 ft 0.30 bath _ 7 Default(8 ibs/sq.ft) 0 0 ft 0.30 hall? _ 8 Default(8 ibs/sq.ft.) 0 ft2 0 ft 0.30 tubed ___ 9 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 his 10 Default(8 ibs/sq.ft.) 0 ft2 0 ft 0.30 hers _ 11 Default(8 Ibs/sq.ft.) 0 fta 0-ft 0.30 mbath 12 Default(8 Ibs/sq.ft) 0 ft2 0 ft 0.30 we HEATING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity -GeothermaPHeatPump- Ducts Block kBtulhr Entry Power Volt Current . 1 Electric Heat Pump Splitlsingle HSPF: 9.00 24.4 0.00 0.00 0.00 sys#1 1 1/8/2022 3:16:09 P.M EnergyGauge®,USA 7.0.00 - FlaRes2020 FBC 7th Edition (2620) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtulhr cfm 1 Central Unit SplittSingle- SEER:16.0 24.4 799 0.70 sys#1 1 HOT WATER SYSTEM # System Type Subtype, Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric None Garage 0.92 (0.92) 50.00'gal 60 gal 120 deg Low None 99 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected. Flow Eff 1 No NA NA. NA No NA NA NA None DUCTS . Supply Return Air CFM 25 CFM 25 HVAC # �Duct # Location R-Value Area, location R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6.0 235 ftz Attic 6.0 53 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programabie Thermostat: Y Ceiling Fans: N Cooling [ ] Jan [ ] Fob [] Mar [ ] Apr [] May [XJ Jun [X] Jul [X] Aug [X] Sep [ ] Oct j ] Nov [ ] Dec Heating [X] Jan [X] .Feb '[X] Mar [ ] Apr [] May []Jun [ ] Jul [I Aug (I Sep [ ] Oct Pq Nov [X] Dec Venting []Jan [ J: Feb [XJ Mar [X] Apr [ ] May . [ ] Jun [ ] Jul [ ] Aug [] Sep [X] Oct [X] Nov (] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 76 78 78 78 78 80 80 '78 80 80 _ PM 80 80 7B 78 78 78 78 78 78 78 78- Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78. _ PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (W EH) AM 66 66 66 66 66 68 68 68 68 68 68 68 _ PM 68 68 68 68 68 68 68 68 68 68 66 66 1/8/2022 3:16:09 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 r-;