HomeMy WebLinkAboutAPPROVED, EQUIPMENT DATA SHEETSThere's no need to sacrifice
ADJUSTABLE BASE CONFIGURATIONS'
your pump's power.
The ideal replacement for high energy -consuming
single -speed pumps up to 1.5 HP, the 115v/230v dual voltage
VS Flo Pro` 1,85 is the onfyvariabte-speed pump on the
market that offers the same performance at both voltages.
• 115v/230v Dual Vottage
With the abitity to provide the same head pressure and
Row rates at both 115v and 230v, the VS FloPro 1.85
eliminates the need for expensive main power rewiring
without compromising performance.
• Add iOPUMPD1 for Instant Automation
Two auxiliary relays can be used to control
other pool equipment, such as booster pumps
and salt chlorinators, for easier installation and
operation. No need for additional timeclocks!
iAyuaLink'
CONTROL
low
• Lower Electricity Costs
Save over $8501 per year in energy costs!
The variable -speed motor allows for dramatic
energy savings and quieter operation.
• Our Quietest Variable -Speed Pump
Over 40% quieten than other Jandy variable -
speed pumps, the VS FloPro 1.85 HP features
proprietary sound dampening motor technology
allowing it to operate with noticeably less noise.
• Choose Your Own Controller
Designed to work with the following Jandy' control
systems for complete programmability and
customization (controller sold separately):
> Jandy AquaLink' Automation Systems
> iQPUMP01 with iAquaLink® App Control
> JEP-R Controller
• Additional Features
> Adjustable base for seamless direct replacement
of a variety of other pumps in the aftermarket
> Zero Clearance TEFC Motor for cool,
quiet operation in tight spaces
2" unions included or utilize 2" internal threads
Easy Controller Setup auto detects connection to
an automation system or a traditional controller,
eliminating the need to adjust settings manually
> RS485 Quick Connect Port for faster
instaltation and maintenance
> Dry Contact Relay Control
> Tool -free lid for easy debris removal
> Ergonomic easy -transport handle
Jandy.com 1 1.800.822.7933
Base Fits
,A. ,B,
Dimension Dimension
Hayward' Super Pump'
No Base Pentair'SuperFlo`' 73/4" 123/4-
Sta-Rile' SuperMaxe
Small Base Hayward Super II'" 8 7/9„ 13 7/8"
Jandy PlusH P and MaxHP Pumps
Small Base
Pentair WhisperFto°
91/6" 141l8"
w/Spacers
Sta- RileDyna-Gias`
Sta-Rite Max-E-Pro'
Small Base
Sta-RiteDura -Glas' 103/4" 153/4"
+ Large Base
Sta-Rite Dura-Glas II
Sta-Rite Max-E-Glas°
DIMENSIONS
Bolt Holes,
Front Edge of Union
Centeno Canter
to Center of Solt Hales
-
i
Max Union
Rae,
Carton
Overall
Model No. THP
WEF` Voktage
Watts Amps Size
Pipe Size`
Weight
Length
VSFHP185DV2A 1.85
8.5 230VAC
1,70OW 7.5
2"a2"
11/2'-2V2"
531bs.
241/2"
115 VAC
1,800W 15.5
V9FHP795ptiR4 Pertormance Curnf
aD 3450 RPM
_ 7D
3 eD 3000 RPM
m RPM
2400 RPM
aSa�tsoD
1730 RPM270
g
120 RPM
600 RPM
a ~~
0 50 20
30 60 50
Flow
3o 7] e0 9D
pate. Gallons Per Minute (GPM)
$00 tt0
190
ss0
used on a 22,50J gallon nooi with Ewa turnovers per day of an energy case of $Q.195lkWh vS comparable
sngfe Speed pumps; when tested in accordance with the applicable ragwrements of 10 CFR 429.
'When compared to the averagp 18 reading of o?her Jandy variable -speed pumps at 1453 RPM from 5 ft..
based an lh rr 3-party independent tab soundlasting
-
smallbase with spacers included with all %Pro pumps. Large hose is optional ca. t R0546400.
WEF = weighted energy factor in ItgaiNiNh. WEF is performance -based metric adopted by the
Department at Energy to characterize the energy performance of dedicated -purpose pool pumps.
nepartment of Energy 10 CFR Parts 429 and 431.
`Always follow lofal building and safelycodes lorpipe'sizing and gurdehnes.
Ns G.
Jand
Pro sel es
INSTALLERS & AHJs*
THE JANDY PRO -SERIES AND SAVE® BRANDED NICHELESS LED UNDERWATER POOL AND SPA LUMINAIRES
ARE LISTED LOW -VOLTAGE LUMINAIRES INTENDED TO BE POWERED BY NRTL-LISTED LOW -VOLTAGE P00L1
SPA TRANSFORMERS. WHEN INSTALLED PROPERLYAND IN ACCORDANCE WITH THE NATIONAL ELECTRICAL
CODE® (NEC@% THESE LUMINAIRES DO NOT REQUIRE ADDITIONAL PROVISIONS FOR BONDING ANDIOR
GROUNDING.
THE JANDY PRO -SERIES AND SAVI BRANDED NICHELESS LIGHTS ARE CERTIFIED FOR "WET -AREA"
INSTALLATIONS, AND ARE COMPLETELY NONMETALLIC AND ARE INTENDED TO BE POWERED BY NRTL-
LISTED LOW -VOLTAGE POOUSPA TRANSFORMERS, CERTIFIED AS COMPLIANT WITH THE APPLICABLE
REQUIREMENTS OF THE STANDARD FOR SAFETY FOR "POWER UNITS FOR FOUNTAIN, SWIMMING POOL,
AND SPA LUMINAIRES" (UL-379). WHEN INSTALLED PROPERLY IN ACCORDANCE WITH THEIR INSTALLATION
INSTRUCTIONS AND IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE® (NEC®),THESE LUMINAIRES
HAVE BEEN FOUND TO BE ACCEPTABLE FOR INSTALLATION IN AREAS WITHIN 10 FEET (3M) OF A POOL OR
SPA. THEY ARE LISTED BY INTERTEK FOR SUCH INSTALLATIONS AND BEAR THE ETL LISTING MARK TO
INDICATE THIS. ADDITIONALLY, THESE LIGHTS DO NOT REQUIRE'ADDITIONAL PROVISIONS FOR BONDING
AND/OR GROUNDING. -
NEC PROVISIONS FOR UNBONDED LUMINAIRES: When these low -voltage luminaires are installed properly, the
National Electrical Code (NEC) allows for an exception to the typical requirements for bonding and grounding in
Articles 680.6 and 680.23.
NEC PROVISIONS FOR POOL WATER BONDING: Article 680.26C of the NEC typically requires bonding of the pool
Tvater. However per 680.26(B)(1) concrete pools are tobe considered conductive duetnthe porous nature of concrete.
If, on a concrete pool, the metal rebar of the pool base is properly bonded as required by the NEC, no additional
bonding is required.
NEC PROVISIONS FOR MINIMUM DEPTH FOR INSTALLATION: Article 680.23(5) requires that pool wall -
mounted luminaires be installed such that the top of the lens is a minimum of 18-inches below the normal
water level of the pool, UNLESS the luminaire is listed and identified for use at lesser depths. Due to their sealed
2-wire,12V, nonmetallic design, the Jandy Pro -Series and SAVI branded nicheless LED underwater pool and
spa luminaires are suitable, and ETL listed, for installations at depths of only 4-inches below the normal water
level of the pool.
For assistance with product installation and usage,
contact Zodiac Pool Systems, Inc. Technical Support c0q1_S
u
at (800) 822-7933.
'AulhaOes having judsdiction Intertek
ZODIAC@ is a registered hademAof zwiac tatemannal, SAS.U.,used underrmease-H04990D REV C
o7PRl•w;
When the batteries are loaded, a red LED light on the
front of the unit wild flash once and a single beep will
sound. This indicates the unit is set up and ready to work.
ENTRY DELAY: After the unit is set up, there will be an 8-12
second alarm delay with the red LED light flashing. After this,
the alarm is ready.
The Safe Pool is designed to sound a loud alert when
children enter through a Safe Pool protected door 1 gate.
When properly installed, the Safe Pool will allow adults to
pass through the protected door 1 gate and immediately shut
off the sounding alarm.
When powered, the Safe Pool is always in protected mode,
The alarm wil I activate the instant when the door ! gate opens
by more than 1 inch (when the magnetic sensors are apart
by more than 1 inch). Once the alarm activates, it will sound
continuously until the BYPASS button is pressed.
When passing through the door/gate from the opposite side,
where the additional BYPASS option is included (S189A does
not include the additional BYPASS button) and mounted,
press that outside mounted BYPASS button to temporarily
disarm, open door, enter and close the door quickly The unit
will re arm Itself within 8-12 seconds.
? ,
When the alarm volume becomes low, or the unit does rat
produce normal alarm sound, the red light will illuminate.
Replace with (3) 1.5V AAA batteries.
The Safe Pool's plastic resists ultraviolet rays from direct
sunikght exposure. However, slight discoioration over time
is normal.
WARNING!
THE SAFE POOL ALARM IS EXTR I MELY LOUD WHEN
ACTIVATED. FOR YOUR SAFETY, NEVER PLACE THE
UNIT CLOSE TO YOUR EARS. TO TEST THE ALARM,
ALWAYS USE EAR PROTECTION AND DIRECT THE UNIT
AWAY BEFORE TESTING / ACTIVATING THE ALARM.
IT IS PROHIBITED BY LAW TO REMOVE THE INSTALLED
ALARM AFTER IT HAS PASSED INSPECTION!
Important Warranty Information;
A dated proof of purchase is required for warranty service
Customer Service
1-888-OTECHKO (1-888-883-2456)
Website: www.techkousa.com
Mfg. By MUM'
9767 Research Drive
Irvine, CA 92618-4626
MADE IN CHINA
USA Patent: No. 5,473,310
No. 6,727,819
No. 7,187,280
NOTICE
THIS PRODUCT 15 PROTECTED UNDER FEDERAL
PATENT, TRADEMARK AND COPYRIGHT LAWS AND
LAWS PREVENTING UNFAIR COMPETITION. NO
DUPLICATION OR SIMULATION OF THIS PRODUCT
15 PERMITTED EXCEPT BY WRITTEN AUTHORIZATION
OF TECHKO, INC.
TECHKO AND THE CONFIGURATION OF THIS PRODUCT
ARE TRADEMARKS OF TECHKO INC.
COPYRIGHT 1994 TECHKO, INC.
ALL RIGHTS RESERVED
MADE IN CHINA
FIB
Safe Pool TM
Model S189A I S189D
Area Entry Alarm
51B9AUNIT
71 5199D UNIT
I —
OPERATION MANUAL
INTRODUCTION
Congratulations on your purchase of the TECHKO Safe
Pool model S189A/ S189D safety alarm. The Safe Pool
can be used to provide a high volume alarm alert when
children have entered a pool or spa area. The 5189A 1
S189D can be used outdoors on wood duurs 1 windows !
gates.
FEATURES i
" Easy installation for gate or door protection
Weather I Water resistant
" (3) 1.5V AAA batteries (included}
High output 100-110 dB B-tone alarm siren
' One button BYPASS operation
Low battery LED display
' Optional additional BYPASS button for delayed entry
from either side of door or fence (5189A not included)
Optional additional magnetic sensor for screen door
exit I entry (S189A not Included)
IMPORTANT SAFETY TIPS _II
"Alarm siron is VERY loud; NEVER place the unit close to
ears.
Install the unit high enough to be out of reach of children
' S189D - addibonat delay button may be mounted on the
other side of the entrance- When pressed, it will delay
the alarm 8 -12 seconds before alarm is triggered, allowing
time to secure the door/ gate.
S189D - additional magnetic sensor allows the unit to be
used on sliding door with screens. Alarm will sound only
when both magnetic sensors are apart.
' Keep this manual for future reference.
The Safe Pool can provide valuable protection when
used correctly- However, it cannot guarantee complete
protection against accidents or injuries. Therefore,
TECHKO cannot be held responsible for any loss,
damage, or injury that may occur.
WARNING: Read all installation and operation
instructions thoroughly before proceeding with
installation. Before installing the battery, use a rubber
band to temporarily secure the two magnetic sensors
together with the arrows pointing toward each Other to
avoid setting off the alarm unintentionally during the
installation of the alarm.
INSTALLING THE BATTERY.
1- Remove the battery cover of the unit and install the
new (3) 1.5V AAA batteries (included) (5ee Fig. 1)
2. If you are sensitive to loud sound, please wear ear
protection against the loud alarm siren before testing
the alarm.
3. Once the battery is connected the unit is now ON and
marking. To teat the alarm siren,
make sure you have ear protection
before testing. After ear protection
is in place, separate the magnetic
sensors apart by more than 1 Inch.
The alarm should sound immediately rD t
after the sensors are separated.
Press the BYPASS button and immediately secure the
two magnet sensors together again to avoid the alarm
sounding oft u nintenbonally.
MOUNTING:
WARNING: The alarm should be positioned close to
the door Ill enough to be out of the reach of children.
As each mounting application varies, TECHKO suggests
testing the unit's installation location and effectiveness
before permanently mounting the S189AI S189D.
Fig. 2
PARTS LIST
51890 NIT BYPASS
nm
� Q Q
� 1 Oouwr woo rue oau. rowr..t
MOUNTING INDOORS USING DOUBLE -SIDED TAPE
Make sure that the mounting surfaces for the double -sided
tapes are completely clean. Attach the double -sided tapes
onto the rear of the unit, and then secure the unit onto the
desired mounting surface.
MOUNTING INDOORS USING SCREW
Using the provided mounting template printed in this
manual, mark the position of the screw hole on the
desired mounting surface. Lint[ the screw in to the
mounting surface with
approximately 0-125 inch of three
remaining. Slide the unit over the o
screw and secure the unit by
pushing it downward as shown in
Fig. 3. You may need to adjust the
screw towards or away from the
mounting surface to provide a more Fig. s
secure fit.
MOUNTING THE SENSORS INDOORS
Make sure that the arrows of each sensor are pointed towards
each other. Using either the double -sided tape or the screw
provided, mount the sensors so that they are less than 1 inch
away from each other. Please make sure that the wired portion
of the magnetic sensor is mounted on the non-moving portion
Of the mounting surface and the standalone sensor is mounted
on the door I gate {See Fig. 4 IFIg. 5).
MOUNTING OUTDOORS ON WOODEN GATES
Using the provided mounting template printed in this manual, mark
the position of the screw hole on the desired mounting surface.
Drill the screw in to the mounting surface with approximately a 125
Inch of thread remaining. Slide the unit over the screw and secure
the unit by pushing it downward as shown in Fig. 3. You may need
to adjust the screw towards or away from the mounting surface to
provide a more secure fit. Make sure that the arrows of each sensor
are facing each other
Fig. 4
MOUrrTrNG OUTDOORS
ON GATES
_
wuarw
va pact
�
i
ac
MOUNTING OUTDOORS ON WOODEN GATES
❑
�r�
MAxIMUM WALL OR W OODEN
DISTANCE DOOR
MOUNTING INDOORS ON GATES
Using the provided mounting template printed in this manual, mark
the position of the screw hole on the desired mounting surface.
S1890-Additional delay button may be mounted on the other side
of the entrance. When pressed, it will delay the alarm 8-12 seconds
before alarm is triggered. allowing time to secure the door r gate
51890, Additional magnetic sensor allows the unit to be used on
sliding door with screens. Alarm will sound only when both magnetic
sensors are apart.
Fig. 5
� r �
TEMPLATE
MODEL S189A / S189D
SCREW
HOLE