Loading...
HomeMy WebLinkAboutAPPROVED, EQUIPMENT DATA SHEETSThere's no need to sacrifice ADJUSTABLE BASE CONFIGURATIONS' your pump's power. The ideal replacement for high energy -consuming single -speed pumps up to 1.5 HP, the 115v/230v dual voltage VS Flo Pro` 1,85 is the onfyvariabte-speed pump on the market that offers the same performance at both voltages. • 115v/230v Dual Vottage With the abitity to provide the same head pressure and Row rates at both 115v and 230v, the VS FloPro 1.85 eliminates the need for expensive main power rewiring without compromising performance. • Add iOPUMPD1 for Instant Automation Two auxiliary relays can be used to control other pool equipment, such as booster pumps and salt chlorinators, for easier installation and operation. No need for additional timeclocks! iAyuaLink' CONTROL low • Lower Electricity Costs Save over $8501 per year in energy costs! The variable -speed motor allows for dramatic energy savings and quieter operation. • Our Quietest Variable -Speed Pump Over 40% quieten than other Jandy variable - speed pumps, the VS FloPro 1.85 HP features proprietary sound dampening motor technology allowing it to operate with noticeably less noise. • Choose Your Own Controller Designed to work with the following Jandy' control systems for complete programmability and customization (controller sold separately): > Jandy AquaLink' Automation Systems > iQPUMP01 with iAquaLink® App Control > JEP-R Controller • Additional Features > Adjustable base for seamless direct replacement of a variety of other pumps in the aftermarket > Zero Clearance TEFC Motor for cool, quiet operation in tight spaces 2" unions included or utilize 2" internal threads Easy Controller Setup auto detects connection to an automation system or a traditional controller, eliminating the need to adjust settings manually > RS485 Quick Connect Port for faster instaltation and maintenance > Dry Contact Relay Control > Tool -free lid for easy debris removal > Ergonomic easy -transport handle Jandy.com 1 1.800.822.7933 Base Fits ,A. ,B, Dimension Dimension Hayward' Super Pump' No Base Pentair'SuperFlo`' 73/4" 123/4- Sta-Rile' SuperMaxe Small Base Hayward Super II'" 8 7/9„ 13 7/8" Jandy PlusH P and MaxHP Pumps Small Base Pentair WhisperFto° 91/6" 141l8" w/Spacers Sta- RileDyna-Gias` Sta-Rite Max-E-Pro' Small Base Sta-RiteDura -Glas' 103/4" 153/4" + Large Base Sta-Rite Dura-Glas II Sta-Rite Max-E-Glas° DIMENSIONS Bolt Holes, Front Edge of Union Centeno Canter to Center of Solt Hales - i Max Union Rae, Carton Overall Model No. THP WEF` Voktage Watts Amps Size Pipe Size` Weight Length VSFHP185DV2A 1.85 8.5 230VAC 1,70OW 7.5 2"a2" 11/2'-2V2" 531bs. 241/2" 115 VAC 1,800W 15.5 V9FHP795ptiR4 Pertormance Curnf aD 3450 RPM _ 7D 3 eD 3000 RPM m RPM 2400 RPM aSa�tsoD 1730 RPM270 g 120 RPM 600 RPM a ~~ 0 50 20 30 60 50 Flow 3o 7] e0 9D pate. Gallons Per Minute (GPM) $00 tt0 190 ss0 used on a 22,50J gallon nooi with Ewa turnovers per day of an energy case of $Q.195lkWh vS comparable sngfe Speed pumps; when tested in accordance with the applicable ragwrements of 10 CFR 429. 'When compared to the averagp 18 reading of o?her Jandy variable -speed pumps at 1453 RPM from 5 ft.. based an lh rr 3-party independent tab soundlasting - smallbase with spacers included with all %Pro pumps. Large hose is optional ca. t R0546400. WEF = weighted energy factor in ItgaiNiNh. WEF is performance -based metric adopted by the Department at Energy to characterize the energy performance of dedicated -purpose pool pumps. nepartment of Energy 10 CFR Parts 429 and 431. `Always follow lofal building and safelycodes lorpipe'sizing and gurdehnes. Ns G. Jand Pro sel es INSTALLERS & AHJs* THE JANDY PRO -SERIES AND SAVE® BRANDED NICHELESS LED UNDERWATER POOL AND SPA LUMINAIRES ARE LISTED LOW -VOLTAGE LUMINAIRES INTENDED TO BE POWERED BY NRTL-LISTED LOW -VOLTAGE P00L1 SPA TRANSFORMERS. WHEN INSTALLED PROPERLYAND IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE® (NEC@% THESE LUMINAIRES DO NOT REQUIRE ADDITIONAL PROVISIONS FOR BONDING ANDIOR GROUNDING. THE JANDY PRO -SERIES AND SAVI BRANDED NICHELESS LIGHTS ARE CERTIFIED FOR "WET -AREA" INSTALLATIONS, AND ARE COMPLETELY NONMETALLIC AND ARE INTENDED TO BE POWERED BY NRTL- LISTED LOW -VOLTAGE POOUSPA TRANSFORMERS, CERTIFIED AS COMPLIANT WITH THE APPLICABLE REQUIREMENTS OF THE STANDARD FOR SAFETY FOR "POWER UNITS FOR FOUNTAIN, SWIMMING POOL, AND SPA LUMINAIRES" (UL-379). WHEN INSTALLED PROPERLY IN ACCORDANCE WITH THEIR INSTALLATION INSTRUCTIONS AND IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE® (NEC®),THESE LUMINAIRES HAVE BEEN FOUND TO BE ACCEPTABLE FOR INSTALLATION IN AREAS WITHIN 10 FEET (3M) OF A POOL OR SPA. THEY ARE LISTED BY INTERTEK FOR SUCH INSTALLATIONS AND BEAR THE ETL LISTING MARK TO INDICATE THIS. ADDITIONALLY, THESE LIGHTS DO NOT REQUIRE'ADDITIONAL PROVISIONS FOR BONDING AND/OR GROUNDING. - NEC PROVISIONS FOR UNBONDED LUMINAIRES: When these low -voltage luminaires are installed properly, the National Electrical Code (NEC) allows for an exception to the typical requirements for bonding and grounding in Articles 680.6 and 680.23. NEC PROVISIONS FOR POOL WATER BONDING: Article 680.26C of the NEC typically requires bonding of the pool Tvater. However per 680.26(B)(1) concrete pools are tobe considered conductive duetnthe porous nature of concrete. If, on a concrete pool, the metal rebar of the pool base is properly bonded as required by the NEC, no additional bonding is required. NEC PROVISIONS FOR MINIMUM DEPTH FOR INSTALLATION: Article 680.23(5) requires that pool wall - mounted luminaires be installed such that the top of the lens is a minimum of 18-inches below the normal water level of the pool, UNLESS the luminaire is listed and identified for use at lesser depths. Due to their sealed 2-wire,12V, nonmetallic design, the Jandy Pro -Series and SAVI branded nicheless LED underwater pool and spa luminaires are suitable, and ETL listed, for installations at depths of only 4-inches below the normal water level of the pool. For assistance with product installation and usage, contact Zodiac Pool Systems, Inc. Technical Support c0q1_S u at (800) 822-7933. 'AulhaOes having judsdiction Intertek ZODIAC@ is a registered hademAof zwiac tatemannal, SAS.U.,used underrmease-H04990D REV C o7PRl•w; When the batteries are loaded, a red LED light on the front of the unit wild flash once and a single beep will sound. This indicates the unit is set up and ready to work. ENTRY DELAY: After the unit is set up, there will be an 8-12 second alarm delay with the red LED light flashing. After this, the alarm is ready. The Safe Pool is designed to sound a loud alert when children enter through a Safe Pool protected door 1 gate. When properly installed, the Safe Pool will allow adults to pass through the protected door 1 gate and immediately shut off the sounding alarm. When powered, the Safe Pool is always in protected mode, The alarm wil I activate the instant when the door ! gate opens by more than 1 inch (when the magnetic sensors are apart by more than 1 inch). Once the alarm activates, it will sound continuously until the BYPASS button is pressed. When passing through the door/gate from the opposite side, where the additional BYPASS option is included (S189A does not include the additional BYPASS button) and mounted, press that outside mounted BYPASS button to temporarily disarm, open door, enter and close the door quickly The unit will re arm Itself within 8-12 seconds. ? , When the alarm volume becomes low, or the unit does rat produce normal alarm sound, the red light will illuminate. Replace with (3) 1.5V AAA batteries. The Safe Pool's plastic resists ultraviolet rays from direct sunikght exposure. However, slight discoioration over time is normal. WARNING! THE SAFE POOL ALARM IS EXTR I MELY LOUD WHEN ACTIVATED. FOR YOUR SAFETY, NEVER PLACE THE UNIT CLOSE TO YOUR EARS. TO TEST THE ALARM, ALWAYS USE EAR PROTECTION AND DIRECT THE UNIT AWAY BEFORE TESTING / ACTIVATING THE ALARM. IT IS PROHIBITED BY LAW TO REMOVE THE INSTALLED ALARM AFTER IT HAS PASSED INSPECTION! Important Warranty Information; A dated proof of purchase is required for warranty service Customer Service 1-888-OTECHKO (1-888-883-2456) Website: www.techkousa.com Mfg. By MUM' 9767 Research Drive Irvine, CA 92618-4626 MADE IN CHINA USA Patent: No. 5,473,310 No. 6,727,819 No. 7,187,280 NOTICE THIS PRODUCT 15 PROTECTED UNDER FEDERAL PATENT, TRADEMARK AND COPYRIGHT LAWS AND LAWS PREVENTING UNFAIR COMPETITION. NO DUPLICATION OR SIMULATION OF THIS PRODUCT 15 PERMITTED EXCEPT BY WRITTEN AUTHORIZATION OF TECHKO, INC. TECHKO AND THE CONFIGURATION OF THIS PRODUCT ARE TRADEMARKS OF TECHKO INC. COPYRIGHT 1994 TECHKO, INC. ALL RIGHTS RESERVED MADE IN CHINA FIB Safe Pool TM Model S189A I S189D Area Entry Alarm 51B9AUNIT 71 5199D UNIT I — OPERATION MANUAL INTRODUCTION Congratulations on your purchase of the TECHKO Safe Pool model S189A/ S189D safety alarm. The Safe Pool can be used to provide a high volume alarm alert when children have entered a pool or spa area. The 5189A 1 S189D can be used outdoors on wood duurs 1 windows ! gates. FEATURES i " Easy installation for gate or door protection Weather I Water resistant " (3) 1.5V AAA batteries (included} High output 100-110 dB B-tone alarm siren ' One button BYPASS operation Low battery LED display ' Optional additional BYPASS button for delayed entry from either side of door or fence (5189A not included) Optional additional magnetic sensor for screen door exit I entry (S189A not Included) IMPORTANT SAFETY TIPS _II "Alarm siron is VERY loud; NEVER place the unit close to ears. Install the unit high enough to be out of reach of children ' S189D - addibonat delay button may be mounted on the other side of the entrance- When pressed, it will delay the alarm 8 -12 seconds before alarm is triggered, allowing time to secure the door/ gate. S189D - additional magnetic sensor allows the unit to be used on sliding door with screens. Alarm will sound only when both magnetic sensors are apart. ' Keep this manual for future reference. The Safe Pool can provide valuable protection when used correctly- However, it cannot guarantee complete protection against accidents or injuries. Therefore, TECHKO cannot be held responsible for any loss, damage, or injury that may occur. WARNING: Read all installation and operation instructions thoroughly before proceeding with installation. Before installing the battery, use a rubber band to temporarily secure the two magnetic sensors together with the arrows pointing toward each Other to avoid setting off the alarm unintentionally during the installation of the alarm. INSTALLING THE BATTERY. 1- Remove the battery cover of the unit and install the new (3) 1.5V AAA batteries (included) (5ee Fig. 1) 2. If you are sensitive to loud sound, please wear ear protection against the loud alarm siren before testing the alarm. 3. Once the battery is connected the unit is now ON and marking. To teat the alarm siren, make sure you have ear protection before testing. After ear protection is in place, separate the magnetic sensors apart by more than 1 Inch. The alarm should sound immediately rD t after the sensors are separated. Press the BYPASS button and immediately secure the two magnet sensors together again to avoid the alarm sounding oft u nintenbonally. MOUNTING: WARNING: The alarm should be positioned close to the door Ill enough to be out of the reach of children. As each mounting application varies, TECHKO suggests testing the unit's installation location and effectiveness before permanently mounting the S189AI S189D. Fig. 2 PARTS LIST 51890 NIT BYPASS nm � Q Q � 1 Oouwr woo rue oau. rowr..t MOUNTING INDOORS USING DOUBLE -SIDED TAPE Make sure that the mounting surfaces for the double -sided tapes are completely clean. Attach the double -sided tapes onto the rear of the unit, and then secure the unit onto the desired mounting surface. MOUNTING INDOORS USING SCREW Using the provided mounting template printed in this manual, mark the position of the screw hole on the desired mounting surface. Lint[ the screw in to the mounting surface with approximately 0-125 inch of three remaining. Slide the unit over the o screw and secure the unit by pushing it downward as shown in Fig. 3. You may need to adjust the screw towards or away from the mounting surface to provide a more Fig. s secure fit. MOUNTING THE SENSORS INDOORS Make sure that the arrows of each sensor are pointed towards each other. Using either the double -sided tape or the screw provided, mount the sensors so that they are less than 1 inch away from each other. Please make sure that the wired portion of the magnetic sensor is mounted on the non-moving portion Of the mounting surface and the standalone sensor is mounted on the door I gate {See Fig. 4 IFIg. 5). MOUNTING OUTDOORS ON WOODEN GATES Using the provided mounting template printed in this manual, mark the position of the screw hole on the desired mounting surface. Drill the screw in to the mounting surface with approximately a 125 Inch of thread remaining. Slide the unit over the screw and secure the unit by pushing it downward as shown in Fig. 3. You may need to adjust the screw towards or away from the mounting surface to provide a more secure fit. Make sure that the arrows of each sensor are facing each other Fig. 4 MOUrrTrNG OUTDOORS ON GATES _ wuarw va pact � i ac MOUNTING OUTDOORS ON WOODEN GATES ❑ �r� MAxIMUM WALL OR W OODEN DISTANCE DOOR MOUNTING INDOORS ON GATES Using the provided mounting template printed in this manual, mark the position of the screw hole on the desired mounting surface. S1890-Additional delay button may be mounted on the other side of the entrance. When pressed, it will delay the alarm 8-12 seconds before alarm is triggered. allowing time to secure the door r gate 51890, Additional magnetic sensor allows the unit to be used on sliding door with screens. Alarm will sound only when both magnetic sensors are apart. Fig. 5 � r � TEMPLATE MODEL S189A / S189D SCREW HOLE