HomeMy WebLinkAboutRevision Building PlansWALL LEGEND
THICKNESS
ON FLOOR
ID
DESCRIPTION
SPECS
PLAN
REINFORCED CMU WALL
SEE TYP WALL SECTION
9"
W/ FINISHES
REINFORCED CMU WALL
SEE TYP WALL SECTION
8"
W/O INT FINISH
❑
REINFORCED CMU COLUMN
SEE FLOOR PLAN
VARIES
NON LOAD BEARING INT WALL
SEE PROJECT SPECS ON A-1
4.5"
iT'i777Ti "
LOAD BEARING 2x4 WALL
N/A NONE PRESENT
4.5"
FLOOR PLAN NOTES:
1. INTERIOR DIMENSIONS ARE TO FINISH. SEE WALL LEGEND FOR THICKNESS.
2. EXTERIOR DIMENSIONS ARE TO STRUCTURE.
FLOOR PLAN KEYNOTES:
1. 22"x30" RO MIN ATTIC ACCESS
2. TYP PORCH COLUMN- 12"x12"x8" CMU, 4 #5 VERT.
3. TYP PORCH BEAM- CASTCRETE 8F16-1B/1T. 9'-4" TOB.
4. NON BRG DROP HEADER
38'-4"
11'-51/4
FLOOR PLAN- DIMENSIONED
SCALE: 1/4"= 1'-0"
PROJECT SPECS:
1. INSULATION: R20 SPRAYFOAM @ CONDITINED ROOF DECK, & ATTIC SEPARATING KNEE WALLS @ PORCHES & GARAGES.
R-13 BATT @ GARAGE SEPARATING WALL, FLOOR TO CLG. PROVIDE ACCESS HATCH TO CONNECT Al rIC SPACES.
SLOPE AS PER ELEV
METAL OVER PEEL/STICK OVER 5/8" CDX PLY OVER PE WOOD _
ROOF TRUSS AS PER FRAMING PLAN.
PE TRUSS AS PER FRAMING PLANS -
INSULATION AS PER PROJECT SPECS -�
SEE FRAMING PLANS OR
CONNECTOR SCHEDULE
METAL DRIP OVER PT WOOD DRIP OVER
2x8 CEDAR FASCIA TO TRUSS ENDS W/ �1
(2) #16d NAIL, -5.5" TRUSS HEEL
UNVENTED ALUM SOFFIT PANELS
LINTELS PER DOOR/WINDOW/LINTEL SCHEDULE
STUCCO OVER 8x8x16 CMU W/ #5 VERT REBAR @ 48" OC
W/ CONT CMU BOND BEAM TOP (2) COURSES W/ #5
REBAR EA COURSE- 1/2" OR 5/8" GWB OVER OVER 3/4"
FURRING STRIP. GARAGE WALLS TO BE UNINSULATED &
UNFINISHED.
WALL REINF AS PER NOTE 16.8/GN-1.
DOWELS PER NOTE 17.2 GN-1.
PROJECT SPECS: A-1
GENERAL NOTES: GN-1
FOOTING PER FOUNDATION PLAN &
FOOTING SCHEDLE- REINF PER
FOOTING SCHEDULE
9
GRADE AS PER SITE PLAN •L
j
TYP WALL SECTION
SCALE: 1/2"= V-0"
+_SEE.ELEVS
1/2" OR 5/8" GWB OVER WOOD PE TRUSS BC.
GARAGE HOUSE
F3
OPTIONAL CJ/EJ 44- 4
MONO 91 STEP
g
OPTIONAL CJ/EJ
W -`
MONO CURB/RECESS
,P..
n
SOG/FILL/COMPACTION PER
17
NDATON PLAN AND NOTE 17/GN-1
SHEETINDEX
A-1
floor plan
A-2
elevs
A-3
foundation/ framing
A-4
elect, plumb
GN-1
general notes
PROJECT DESCRIPTION
NEW 1 STORY SF RESIDENCE.
ZONING INFORMATION:
PARCEL ID: 3402-607-0239-000-0
RS-3 (ST LUCIE COUNTY)
FLOOD ZONE: X
UTILITY INFORMATION:
gas: n/a
sewage: septic
potable water: public
AREA CALCULATIONS:
conditioned living area
1,991 sf
garage
563 sf
front porch
617 sf
rear porch
383 sf
total building area
3,554 sf
conditioned volume
18,915 cf
DOOR/ LINTEL SCHEDULE
ACTUAL
PRESSURES
DESCRIPTION
D1 31.9, -41.7
3-0 8-0 CC 8RF14-1B/1T S. SWING, GLAZED
D2
31.9, -41.7
6-0 8-0 CC 8RF14-1B/1T D. SWING, GLAZED
D3
28.2, -31.5
16-0 8-0 CC 8F16-1B/2T SECTIONAL OVERHEAD
SEE GEN NOTE 26. CC= CASTCRETE
WINDOW/
ACTUAL
PRESSURES W H
W1 33.4, -44.8 (2) 3-0 5-2
:•
LINTEL
8-0
LINTEL SCHEDULE
LINTEL TYPE NOTES
CC 8F16-1B/1T (2) S. HUNG
W2
33.4, -44.8
3-0
5-2
8-0
CC 8F16-1B/1T
S. HUNG
W3
33.4, -44.8
(2) 3-0
5-2
8-0
CC 81`16-113/1T
(2) S. HUNG
W4
33.4, -44.8
3-0
5-2
8-0
CC 8F16-1B/1T
S. HUNG
W5
33.4, -44.8
(2) 3-0
5-2
8-0
CC 8F16-1B/1T
(2) S. HUNG
_
EGRESS
W6
33.4, -44.8
(2) 3-0
5-2
8-0
CC 8F16-1B/1T
2) S. HUNG
EGRESS
W7
33.4, -44.8
3-0
4-6
8-0
CC 8F16-1B/1T
S. HUNG
W8
33.4, -44.8
3-0
2-0
8-0
CC 8F16-1B/1T
_
FIXED
W9
33.4, -44.8
2-8
5-2
8-0
CC 8F16-113/1T
S. HUNG
EGRESS
W10
133.4, -44.8
2-8
5-2
8-0
CC 8F16-1B/1T
S. HUNG
SEE GEN NOTE 26. CC= CASTCRETE
PRODUCT
APPROVAL AFFIDAVIT
GLASS
ITEM TYPE IDi BUILDING DP 2 PRODUCT DP
TYPE MFR MODEL
APPROVAL 4
FASTNERS6
DOOR OVERHEAD ALL 31.9, -41.7 36 ,-44
N/A DAB ANY
NOA 20-0107.06
DOOR
S. SWING, GLAZED
ALL
31.9, -41.7
50,-50
IMPACT
Jeld Wen
ANY
FL 16674.2
DOOR
D. SWING, GLAZED
ALL
31.9, -41.7
50,-50
IMPACT
Jeld Wen
ANY
FL 16674.4
WINDOW
FIXED
ALL
33.4, -44.8
55,-55
IMPACT
Jeld Wen
ANY
FL 14088.3
WINDOW
S. HUNG
ALL
33.4, -44.8
65,-70
IMPACT
Jeld Wen
ANY
FL 14095.1
WINDOW
S. HUNG
ALL
33.4, -44.8
65,-70
IMPACT
Jeld Wen
ANY
FL 14095.4
WINDOW
MULLION
ALL
44.8
57
N/A
Jeld Wen
1x3
FL 11870.1
t-clip w/ (4) .25"x1.5" embed ea clip
ROOFING
UNDERLAYMENT
ALL
N/A
N/A
N/A
Owens Corning
WeatherLock
NOA 18-0523.02
self adhered
-56.1 field, -
ROOFING METAL ALL 78.8 edge -166 N/A Dynamic Metals 1500
FL 27499.12
clip @ 16" oc/ 4" ends
1. 'ID' as per door & window schedule, or all meaning worst case of all similar items of that type.
2. If building dp are left blank- see door & window schedule or design pressure chart.
3. This affidavit is only to verify product's compliance with wind loads.
4. Unless products are specifically submitted for verification by contractor, they are assumed.
5. If glass type is not specified more than 'impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures.
6. If fasteners is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building
design pressures.
7.1 have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions.
PN
+-'
o
E
o
U
`
at;
_
E +.
°
c c°+ o -
CU
CL
(n
r*o
L
a
c
® Lo E
ao 'qtCM
+
m
1_
N (D V
= N N i m
E- N
CY)
•N L=co
~
~
a)
N
0 c
+
�
Y
C J
J O
U. V
r
U
co LL
"'
0
t.7
0
U
w
0
a
U
LL
U
w
a
U)
x
0
LL
0
w
n.
0
w
0
0
z
0
w
J
O
w
W
o
V
N
�
W
uj
W
Uj
M
z
a
V
v)
-�
z
W
w
a
WJ
Z
Q
z
m
z
J
�
to
to
w
Ill
LL
o
LL
p
z
CL
a
z
.J
C�
E
w
x
z
'^
(�
¢
W
w
�J J
x
l�
F-
0
WI----
0
z
w
d
U
0
Z
z
z
w
2
w
U
z
0
z
g
a
vi
z
0
w
0
ui
u�
0
J
z
w
O
U
W
H
floor plan
8/27/21
SHEET
A-1
r;�'c,IS P. L�F9 9
AR97108
RIGHT ELEMATION
SCALE: 3/16"= 1'-0"
LEFT ELEV TION
SCALE: 3/16"= 1'-0"
4112 METAL
FRONT ELEVATION
SCALE: 3/16"= 1'-0"
um I
E
r
o
O
E U�
t1
N
C =
�
ONp
L�
co
L
a;Q Lo
a
C 'D
-Q
0. cc::"
0 'D
rn�
m r=
N N
d M
m
N�
G p
�j
.C] .i
62
Oco
LL U
U
4—
U
W
u
u
Z
00
0)
°
(
u
Wu
W
c' M
J
-
C s
Z
LIJ
LL
u
ti
v
W
0-
J
L�
�cl)
u LL
W
aC
0
c
0�
u-
O
Z
w
J
u
LL
a
Z
C�
E
LL
17
LL
Z
n
4
LL
u
r n
VJ
z
u
a_
F
z
W
C
LL
Z
LL
a
elevs
8/27/21
SHEET
A-2
�. NoS R LIA e�, .9
AR97108
REAR ELEVATION
SCALE: 3/16"= 1'-0"
ROOF PLAN
SCALE: NT'S
10'-8"
•
r— — — — — --_. - — — — —i
iI
� 1IIIII(IiI
-II III I II
I
I
II
II
s
-N
tO
1 F4 SOG, MONO, INTERIOR
20_ xCO/NTx1
80'-0" (2) #5 CONT
SWR RECESS
FFE: -0'-4" � FOUNDATION NOTES:
lk -SEE GEN NOTES 17.2 FOR DOWEL LOCATIONS. FILLED WALL CELLS ARE MARKED
ON PLAN FOR CLARIFICATION.
-SEE FLOOR PLAN FOR DIMENSIONS
FOUNDATION KEYNOTES:
1. TYP FILLED CELL
zo
6-7" 12'-5" 38'4"
V-111/4" 1 V-51/4" 1 V-11 1/4"
---------------- — — —
— — F2, TYP PORCH
4" SOG
AFF: -0'-4"
1/8" SLOPE
F4 8!-6" 10'-11/2" 12'-51/2" T-3"
--------------------
— ------------------ — — — - ——
�IIII
(I
--————————————————————————
I
1iIII II
I-
II IIII
(
— 12'-7" 4'-8"
2'-1/2" T-5"
F3
FTYP HOUSE UN'O
5'-4" F3 4"SOG
AFF: 0'-0"
4" SOG T-3 3/4" 2-7L"
AFF: -0'-4"
1/8" SLOPE
— — — — —
1----•IIIIIIi
III
I
I
I
II
II
LI
�
I
i
I
I
I
I
IIII
I—
— —T-3 6'-11 314" 8'-11 1/2"
1 V-5"
4" SOG
AFF: 0-4"
118" SLOPE F2, TYP PORCH
-----------
T-3" IIIII
----------
FOUNDATION/SLAB PLAN
SCALE: 1/4"= V-0"
CONNECTION (CXN) SCHEDULE
TRUSS ACTUAL
ACTUAL
CONNECTED ELEMENTS
REACTION ID UPLIFT
GRAVITY CONNECTOR ID
A L1U"LUUU11UUeam
locations uno
truss
CO-1
valley truss to ea supporting
truss
truss
CO-6 or CO-7
truss GR2
truss
CO-8
truss GRA
18,27
truss
Co -
truss GRB
18
truss
Co -
truss GRB1
truss
CO-9
1. Connector ID references the connector (CO) schedule.
2. All loads are checked by architect, loads left blank were checked but are not required to be listed.
3. Actual loads listed in this schedule are worst case, actual may be lower than listed but never higher.
4. If'connected elements' contains 'truss', reference loads in truss package. If no reaction points specified use
connector for all nesessary points.
CONNECTOR (CO) SCHEDULE
ALLOW•
r CONNECTED ELEMENTS UPLIFT GRAVITY CITY MFR MODEL
CO-1 see CXN sched 1810 1 Simpson META 20 To truss w/ (9) 10d x 1.5"
CO-2
see CXN sched
2035
2
Simpson
HETA 20
To single ply truss w/ (10) 10d x 1.5"
CO-3
see CXN sched
250
22
Simpson
IHTSM20
HETA 20
To multi ply truss w/ (12) 16d
To conc w (4) .25" x 2.25" tapcon. To truss w/ (10)
CO-4
missed or misplaced co-1
1175
1.
Simpson
10d x 1.5"
To conc w/ (4) .25" x 2.25" tapcon. To truss w/ (10)
CO-5
missed or misplaced co-1
2350
2
Simpson
HTSM20
10d x 1.5"
To valley truss be w (3) 10d x 1.5". To supporting
CO-6
see CXN sched
370
1
Simpson
VTCR
truss tc w/ (4) 10d.
To valley truss be w/ (4) 10d x 1.5". To supporting
CO-7
see CXN sched
500
1
Simpson
MST12
truss tc w/ (4) 10d x 1.5.
To truss w/ (16) 10d. To conc w/ (2) 5/8" TR epoxied
CO-8
see CXN sched
10980
1
Simpson
HGT-2
12" into bond beam.
To truss w (22) 10d nails. To conc w/ 5 8" TR epoxied
CO-9
see CXN sched
3965
1
Simpson
MGT
12" into bond beam
1. Refer to connection CXN schedule for connector locations.
2. 'CITY' referes to the number of connectors used per per ea connection (connected elements). If qty left blank, refer to drawings.
CAST-CRETE LINTEL DIAGRAM
,
----F = FILLED WITH GROUT / U = UNFILLED
QUANTITY OF #5 FIELD ADDED REBAR AT
BOTTOM OF U-LINTEL CAVITY FOR
GRAVITY LOAD
6F16-1 B/1 T
1
NOMINAL WIDTH
L- QUANTITY OF #6 FIELD
NOMINAL HEIGHT--`
ADDED REBAR AT TOP OF
COMPOSITE U•LINTEL FOR
UPLIFT LOAD
#5 FIELD ADDED REBAR AT
TOP OF COMPOSITE
U - LINTEL MIN. (1) REQ'D
•
1-1/2" CLEAR
--FIELD PLACED C.M.U.
a
a
"
• �`
O
<
GROUT
H
2
I
a
•
#5 FIELD ADDED REBAR AT
BOTTOM OF U-LINTEL CAVITY
7.5l8" ACTUAL - BOTTOM REINFORCING
PROVIDED IN U.LINTEL
8" NOMINAL WIDTH (SEE REINFORCING SCHEDULE)
LINTEL AS PER WINDOW/DOOR
SCHEDULE
DOOR & WINDOW BUCK AS
PER GEN NOTE 26.2
FLASHING AND SEALING AS
PER GEN NOTE 26.7
WINDOW FRAME W/ FLANGE,
ATTACH TO MASONRY/CONC AS
PER MFR SPECS
HiWind MASONRY SILL BY CASTCRETE
EXT INT
�1• y
SECTION ELEVATION CHANGE- ELEVATION VIEW
I,--
E
Q
O
� 0
N
�
C mot-CN .CU
a :�:J
�,i
CD i01
�C��
m p
Q M a)�._
E `� N -Q
•� i=N
iv
0 (a
Y
J C
r) C
r CU
LL
v �-
CK
U
W
U
N
Z
00
W
Nt
UJ
0
M
V
U)
Z
W
�—
W
W
n:
LL
Uj
Q
G1
H
O
Z
W
a�
Z
C.�
E
Z
co
L..
m
W
I---
Z
F_
Z
W
O
H
x
foundation/ framina
8/27/21
SHEET
A-3
r,�)!��C%S
.
AR97108 ,
SCALE: NTS
w w
E2 E2
L5---
i
I
I
I
I
I
I
L5-----------------------L5
I
I
I
I
I
I
I
I
I
I
I
I
L5 L5
I I
I I
I I
I I
I I
I I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
L5
I
I
I
I
I
I
I
I
I
I
L5
I
I
I
I I
I I
I I
I 1
I I
I I
I I
L5 i
I
I I
I I
I I
i
I
I
E5 E2
L5
I
I
I
I
I
I
i
I
I
I
I
I
I
I
I
I
i I
I I
I I
i E2 E5
I L5
I I
I I
1 I
I
I
I
1
I
I
I
I
I
L5
I
I
I
I
I
L5
I
I
I
I I
I I
L5 I
I I
I I
i
i
I
I WOf
I
I
I
I
I
I
I I
I I
I I
t I
I I
I W
i
i
i I
I I
i
I
I
I
I
I i
I I
i I
I
05'
\\�E5
L5-----------------------
L5 L5
E2 w E2
DETACHED GARAGE/SHED ELECT PLAN
SCALE: 3/16"= T-O"
SK 1.5" AAV
i "„
SCALE: 1/8"= T-0"
L 11
ELECT PLAN NOTES:
1. SEE GENERAL NOTES 27 ON GN-1.
2. GFI PER PLAN & GEN NOTE 27.4. INCLUDING ALL RECEPTACLES IN LAUNDRY ROOM, WASHER,
DISHWASHER, GARAGE DOOR OPENER.
3. PROVIDE DISCONNECTS FOR WATER HEATER, CU, AHU
4. ALL 120 VOLT BRANCH CIRCUITS SUPPLYING RECEPTACLES INSTALLED IN FAMILY ROOMS, DINING
ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION
ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY LISTED
ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF
THE BRANCH CIRCUIT (NEC 210.12(B)).
L1--------------- --- L1------------- - - - - -- L1--------------------L1
I i
i
I I
I I
I FL
L1L1-------------------L1--------------------L1
u� `
w ` %'' `n
w
f
E1 w W W w CO: w w
W I 00 1 LS
F, I ww L1----------------
L1
E1 I \� i L----------r' E2
� , I E1
L1 `� L1 L1----------- L1 I
SD E1 / I i w
W E1 E-RG i FA
/ I
N L7
w W W % SD / I
W w / i I I I I E2
m L5 /,' i FL i L1 - - - LS I // i E1
SD
E-OV W
L91t----------'I E1------------------------
I N I
w ` I
-- - - - - - - - - - - - - - - -- � L1
E2 L1
I �
I � '
05 w
I I � E1 ` /
— — L12
j L1———————— — — — — —— L1---------------L1 _
W �\
I I 4 i i SD E2 J EX
I I W
E1 PIP w
90 CD x� I
w0 I WX E150
wx
I
FA i i I E1
I � I
L5 E1 I i I FA I
I
E1
I L1 .' L1------------- --L1 I I E1
L9 E2 E1 L1---------------L1
Li w W
to r I I
W JLO
------ I I W
ALL L11
-------------------
L1=-----------------L1------------------------ L1------------------------ L1L1
L11
ELECT PLAN LEGEND
L1-------------------- L1
E1 I I
I I
I I
I I
I I
I I
FA
ELECT PLAN
SCALE: 3/16"= 1'-0"
E1 120V DUPLEX RECEPTACLE
E2 120V GFCI DUPLEX RECEPTACLE
E3 120V RECEPTACLE recessed for tv
E4 120V GFCI DUPLEX RECEPTACLE- soffit
E5 120V GFCI DUPLEX RECEPTACLE wl water protected box
E6 240V RECEPTACLE- gene backfeed w/ panel lockout
E7 120V RECEPTACLE- floor
E8 PANEL FOR RV: 120V- 20A GFI, 240V- 30A & 50A
E- ELECTRIC FOR LABLED APPLIANCE
L1 RECESSED CAN LIGHT
L2 FLUSH MOUNT CLG LIGHT
L3 FLUSH LED STRIP LIGHT
L4 VANITY WALL LIGHT
L5 SHOP LIGHT
L6 CHANDELIER LIGHT
L7 PENDANT LIGHT
L8 UNDER CABINET LIGHT
L9 EXTERIOR WALL SCONCE
L10 WALL MOUNT READING LIGHT
L11 EXTERIOR MOTION DETECTOR LIGHT
L12 RECESSED CAN LIGHT- wet location
L13 RECESSED CAN LIGHT- exterior soffit
S LIGHT SWITCH
EX EXHAUST FAN- vent to roof if vented soffit, soffit if unvented
EXL EXHAUST FAN WITH LIGHT- vent to roof if vented soffit, soft t if unvented
FL FAN/ LIGHT COMBO
FA FAN W/O LIGHT
JB JUNCTION BOX
SD SMOKE/CO2 DETECTOR- interconnected, hardwired w/battefY
TV TELEVISION CABLE
NEW METER
OQ0 co VO 0 no
cg cg c_j Mw_j
aQ o Q aQ CL Q
N
�� N NN �IJO
GEC TO CWP, UFER, c c c c
INTERSYSTEM
NEW
UNDERGROUND
WIRE SIZE BY ELECTRICAL
CONTRACTOR
ELECTRICAL RISER DIAGRAM
SCALE: N.T.S.
Electric Load Calculation
E5
L11
220.12 General Lighting Load
3 vaW of floor area, including unused space adaptable for future use.
Floor Area = 1991 fe 5,973 va
Basement Floor Area = fe va
220.52(A) Small Appliance Load
1500 va for each 20 amp branch circuit required per 210.1(C)(1) in EACH kitchen,
pantry, breakfast room, dining room, or similar areas.
# of Small Appliance Branch Circuits =�■ 1500 va = 3,000 va
220.52(8) Laundry Load
# of Laundry Branch Circuits =■ 1500 va - 1,500 va
Total General Lighting 8 Appliance Load- 10,473 va
220.42 Lighting Load Feeder Demand Factors
First 3000 or less at i00% 3,000 va
From 3001 to 3.2o,000 at 35% 2,816 va
Remainder over szo,000 at 25% - va
Total Lighting Demand Load- 5,616 va
220.54 Electric Clothes Dryers
Qty 1 Electric Dryer #1 5 00 kw 5,000 w
city 0 Electric Dryer #2 kw - w
220.55 Electric Cooking -Ranges, Stove Tops and Wall Ovens
QtY 1 Electric Range Nameplate 8.00 kw
Qtyl 1 Wall Oven Nameplate 8.00 kw
Qtyl o _ kw
Electric Cooking Demand Load= 10,400 w
220.61 Fixed Electric Space Heating Loads or Air Conditioning Load: _
Fixed Electric Space Heat #i 10.0 kw AC#1/Geo 16 SEER 4 Ton 5.1 kva
Fixed Electric Space Heat #2 - kw AC#a/Geo kva
Fixed Electric Space Heat #3 kw AC#3/Geo kva
Fixed Electric Space Heat #4 kw AC#4/Geo kva
Fixed Electric Space Heat #5 kw AC#5/Geo kva
Total Heat & AC Load = 15,078 va
220.14 Appliance load --Dwelling Units
Qty Description vaiwattsl ON naarrintinn si.nka�
0
i
Dishwasher
1,200
i
Refrigerator
1,440
1
Microwave
1,580
0
0
0
Total Connected Appliance Load =
31,220 va
220.53 Appliance load —Dwelling Units
Total Appliance Demand Load =
23,415 va
220.60 Motor Loads Q 120 Volts
Qty Description va(watts) Qty
i
Description va(watts)
3/4hpPool/Spa Pump 563 0
1/2hpGarbage Dispose 375 0
1/2hpGar/DoorOpener 375 0
E�E
- o
Total Motor Load =
1,313 va
430.24 Several Motors or a Motors) and Other Load(s)
25% of Largest Motor Load =
141 va
Total Motor Demand Load =
1,464 va
TOTAL CALCULATED DEMAND LOAD in Volt-amperes =
60,962 va
TOTAL CALCULATED DEMAND
LOAD in AMPS @1201240V 1ph3W =
254 amps
EXISTING SERVICE SIZE NEW AMPS
MINIMUM SERVICE SIZE 400 AMPS
SERVICE SIZE REQUESTED =
400 amps
Note: Electrical contractor to verify accuracy and completeness of load calculation. HVAC specs are esitimates only
A L
C
W
O
'ca
,F,
d
LIB
m p
8� v 0
N .O
� C
C
W
W
W
Z
Z
W
0
U
Tr
i
W
U
Z
W
vJ
�W/
L.I.
cJ
G
Q
LL
J
Z
rr
vJ
W
Z
elect, plumb
8J27/21
SHEET
A-4
BASIS OF STROCTURAL DESIGN:
SOIL BEARING: 2500 PSI(assumed)
r
WIND: 160mph (ult), risk at 2, exp C, wind borne debri region, .18 enclosed design
FROST DEPTH: 12"
- THE STRUCTURAL DESIG�TSIGN.
APPROACH FOR MASONRY, ROLLED STEEL, AND LIGHT WEIGHT
STEEL IS WORKING STR DESIGN. THE DESIGN APPROACH FOR REINFORCED CONCRETE
IS ULTIMATE STRENGTH THE DESIGN SERVICE LOADS ARE AS FOLLOWS:
ROOF LIVE LOAD
20 PSF(slope<4:12), 15 PSF(slopez4:12)
ROOF DEAD LOAD
10 PSF TC (shingles, metal, modified bitumen)
ROOF WIND LOAD
(SEE DRAWINGS)
CEILING DEAD LOAD
10 PSF BC
WALL WIND LOADS
S DRAWINGS)
(SEE )
(
FLOOR DEAD LOADS
15 PSF TC,
5 PSF BC
FLOOR LIVE LOADS
SEE BELOW
FLOOR LIVE LOADS:
it storage
10 psf
Uninhabitable attics witho
Uninhabitable attics with I
mited storage
20 psf
Habitable attics and attics
served
with fixed stairs
30 psf
Balconies (exterior) and
cks
40 psf
Fire escapes
40 psf
Guardrails and handrails
200 lb
Guardrail in -fill componerts
50 plf
Passenger vehicle garages
50 psf
Rooms other than sleepir
g room
40 psf
Sleeping rooms
30 psf
Stairs
40 psf
WIND PRESSURES
asd
COMPONENT AND CIADDING
LOADS... FROM TABLE FBC R301.2(2)
EFFECTIVE
ZONE
WIND
AREA (SF)
160
1
10.0
24.9
-56.1
1
j j 20.0
21.5
-56.1
1
1 1 50.0
16.9
-43.3
1
1 1 100.0
13.6
-33.4
2r
10.0
24.9
-73.1
Hip Roof 2r
20.0
21.5
-65.8
7 20 2r
50.0
16.9
-56.3
d
deg 2r
100.0
13.6
-49.0
2e, 3
1 10.0
24.9
-78.8
2e, 3
1 20.0
21.5
-70.9
2e, 3
1 50.0
16.9
-60.4
2e, 3
1 100.0
13.6
-52.4
4
1 10.0
33.4
-36.3
4
1 20.0
31.9
-34.7
4
1 50.0
30.0
-32.8
4
100.0
28.4
-31.2
4
500.0
24.9
-27.7
Wall
5
10.0
33.4
-44.8
5
20.0
31.9
-41.7
5
1 50.0
30.0
-37.8
5
1 100.0
28.4
-34.7
5
500.0
24.9
-27.7
Garage 9'x7'
1
29.4
-33.3
Door 16'x7'
-3
1.21 adjustment
factor used
?h
I-j-
*
%
(aJ-,
- I r i-
I ;i
- -
I I � ,= I
I I I
t_ ___
rt 1
h
I
I I
,�11 G 1 Ct�
I I
I' `1
8]. a A TIZIN
I I
G,.6t,
I I G.b.4
L,
I L - -
r_. __c _
J I Fi2',,
�l
l.N
GaVe and Plat Roots LH 5
7'
a
N_ _.
= -
r its
___ I 0 - _
I
1 I 1`
x
,
I 1
I 1 1
y
t 1
I
i 1 1
1
$
i t. tl
1
FIE F ATit7N
, I I
I I
I
,-,I---1-�-
. -.
I
III-: a \
Gabi* and l' lat Roots P I{ US 45"
- _ ; 1~ -_
I w1 F
< f
I ♦ -
I ,
I 1 1
�1 `� Iw o I �� $
I al � I
i . , EL.EVATItl\
I r , + ` , I
`i I Yi,
ll N
� t
Hip Roots 7* C o:45"
--,�k
r, ` =i1.
1:1
Walls
VCIVCf%J6%L IVV 1 CJ- I WbIUCIILIaI
1. CODE COMPLIANCE:
1.1. This project was designed under the following codes. The construction documents cannot reference all of the codes require for the
construction of this building. By submitting these construction documents for permit or commencing work, the contractor, hereby
agrees to comply with all local, state, and federal regulations having jurisdiction over this project, and to comply with all governing
codes, including but not limited to, the most current editions as adopted by the state of Florida, of the following:
-2020 FBC: RESIDENTIAL, 7th ed -2017 NATIONAL ELECTRIC CODE
-2020 FBC: ENERGY CONSERVATION, 7th ed -ASCE 7-16
2. ALL GENERAL NOTES
2.1. THE FOLLOWING SPECIFICATIONS ARE MINIMUM REQUIREMENTS TO SUPPLEMENT THE DRAWINGS. IN CASE OF
CONFLICT, NOTIFY ARCHITECT. THESE DRAWINGS, IN CONJUNCTION WITH OTHER SUBMITTALS, REPORTS, OR
WRITTEN INSTRUCTIONS BY ARCHITECT OR CONSULTANTS, SHALL BE CONSIDERED THE COMPLETE CONSTRUCTION
DOCUMENTS.
2.2. THE FOLLOWING GENERAL & SPECIFIC NOTES SHALL APPLY EQUALLY TO ALL CONTRACTORS, SUBCONTRACTORS,
AND SUPPLIERS ENGAGED IN EXECUTION OF WORK ON THESE PLANS.
T
2.3. GENE
RAL CONTRACT
OR SHALL FUR
NISH A COM
PLETE SET OF
DRAWINGS AND ADDENDUM'S O ALL
SUBCONTRACTORS ON THE JOB AND COORDINATE THEIR WORK. ANY DISCREPANCIES AND/OR CONFLICTS IN THE
DRAWINGS SHALL BE NOTIFIED TO THE ARCHITECT BEFORE PROCEEDING WITH ANY INSTALLATION. FAILURE TO DO
SO WILL BE THE ENTIRE RESPONSIBILITY OF THE GENERAL CONTRACTOR. ANY COSTS ARISING TO CORRECT THE
DISCREPANCY AND/OR CONFLICT SHALL BE BORNE BY THE RESPONSIBLE PARTY.
2.4. NO DEVIATION OF THE APPROVED SET OF DRAWINGS WILL BE MADE IN THE FIELD WITHOUT THE EXPRESSED
WRITTEN CONSENT OF THE ARCHITECT AND BUILDING OFFICIAL. IN SUCH CASE THE ARCHITECT SHALL PREPARE A
REVISION IN ACCORDANCE WITH THE CHANGE. APPROVAL FROM THE BUILDING OFFICIAL SHALL BE OBTAINED BY THE
CONTRACTOR BEFORE PROCEEDING WITH ANY WORK.
3. ARCHITECT & CONTRACTOR RELATIONSHIP
3.1. UNLESS CONTRACTED DIRECTLY BY CONTRACTOR, THE ARCHITECT AND CONTRACTOR ARE NOT IN A CONTRACTUAL
RELATIONSHIP, THE ARCHITECT IS AN AGENT OF THE OWNER. BY SUBMITTING THESE CONSTRUCTION DOCUMENTS
FOR PERMIT, THE CONTRACTOR ACKNOWLEDGES THAT THEY ARE COMPETENT, UNDERSTAND THE DOCUMENTS, AND
ARE BOUND BY THE TERMS OF THE DOCUMENTS. IF THE CONTRACTOR VEERS FROM THESE PLANS, THEY ARE
ACCEPTING LIABILITY THAT MAYARISE DUE TO CHANGES. ARCHITECT IS NOT LIABLE FOR THE CONTRACTOR'S
INCOMPETENCY TO UNDERSTAND THE CONSTRUCTION DOCUMENTS. IT IS NOT THE ARCHITECT'S ERROR OR
OMISSION IF THE ARCHITECT DOES NOT SPECIFY/REFERENCE SOMETHING THAT IS REQUIRED BY THE CODES
MENTIONED, THE CONTRACTOR AND SUBS ARE REQUIRED TO UNDERSTAND AND ADHERE THE BLDG CODES NO
DIFFERENT THAN THE ARCHITECT.
4. WORKMANSHIP:
4.1. ALL WORK SHALL BE PERFORMED IN THE BEST AND MOST PROFESSIONAL MANNER BY CRAFTSMEN SKILLED IN THEIR
RESPECTIVE TRADES.
5. COORDINATION:
5A. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF WORK FOR ALL TRADES.
5.2. A DRAWING MAY INADVERTENTLY OMIT SOME RELATED ITEM FROM ANOTHER DRAWING. THIS DOES NOT MEAN THAT
THE SECONDARILY OMITTED ITEM IS NOT REQUIRED IN SO FAR AS IT AFFECTS THE TRADES. ALL TRADES SHALL
INCLUDE EVERYTHING NECESSARY FOR A COMPLETE AND PROPERLY FUNCTIONING CODE - ACCEPTABLE PROJECT,
UNLESS CERTAIN ITEMS ARE SPECIFICALLY INDICATED AS BEING PROVIDED BY OTHERS AS "NIC" (NOT IN CONTRACT).
7. CONDITIONS NOT DETAILED:
7A. CONSTRUCTION DOCUMENTS CANNOT DETAIL EVERY CONDITION OR INSTRUCT THE CONTRACTOR ON HOW TO
PERFORM THE WORK. EVERY CONNECTION, CORNER, FLASHING, ETC. MUST BE RESOLVED. NOTIFY ARCHITECT IF A
CONDITION NEEDS ADDITIONAL DIRECTION OR DETAIL. ARCHITECT IS NOT LIABLE FOR WORK THAT IS NOT
DETAILED/SPECIFIED BY ARCHITECT. IF DRAWINGS HAVE A DETAILED SPECIFICATION FOR ACERTAIN PRODUCT,
CONTRACTOR MAY REQUEST A SUBSTITUTION APPROVAL BY ARCHITECT. IF DRAWINGS HAVE A GENERIC
SPECIFICATION CONTRACTOR IS FREE TO USE ANY PRODUCT THAT MEETS WHAT IS SPECIFIED WITHOUT APPROVAL
BY ARCHITECT.
8. VERIFY SITE INFORMATION,
8.1. CONTRACTOR IS TO VERIFY ALL SITE INFORMATION AND ASSUMPTIONS, ESPECIALLY SUBTERRANEAN CONCEALED
CONDITIONS INVOLVING HIDDEN UTILITIES AND SOIL CONDITIONS. SHOULD ANY CONDITIONS AFFECTING THE WORK
BE DISCOVERED BY THE CONTRACTOR, HE IS TO NOTIFY THE ARCHITECT IMMEDIATELY. CONTRACTOR SHALL VERIFY
THAT EXISTING SOILS MEET THE MINIMUM CAPACITY PER THE STRUCTURAL DESIGN.
9. PRIOR TO ANY EXCAVATION WORK:
UNDER CON, MAKE
9.1. THE CONTRACTOR IS REQUIRED TO LOCATE ANY AND ALL UTILITIES IN OR U CONSTRUCTION, AND
ARRANGEMENTS FOR THEIR LEGAL RE-ROUTING, AS ACCEPTABLE TO GOVERNING AGENCIES, AUTHORITIES,
UTILITIES AND OWNER. CONTACTALL AFFECTED UTILITY COMPANIES AND INFORM THEM OF THE IMPENDING
CONSTRUCTION, AND OBTAIN THEIR ASSISTANCE IN LOCATING THEIR UTILITIES.
10. DIMENSIONS:
PLANS REQUIREMENTS.
" R "FINISH." SEE FOR RE UIR
10.1. DIMENSIONS ON ARCHITECTURAL DRAWINGS MAYBE "ROUGH O Q
ARCHITECTURAL DIMENSIONS SHALL TAKE PRECEDENCE OVER STRUCTURAL OR OTHER DIMENSIONS, IF NO OTHER
CONFLICT RESULTS. DOCUMENT ANY SUCH DISCREPANCIES TO ARCHITECT IN WRITING. DO NOT RELY ON SCALED
DIMENSIONS. NOTES TAKE PRECEDENCE OVER GRAPHICS. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS FOR
WORK TO EXISITING BUILDINGS.
11. HEIGHT ELEVATIONS:
11.1. BUILDING HEIGHT ELEVATIONS TYPICALLY USE THE MAIN FLOOR SLAB AS ELEVATION 0'4- (BUILDING ELEVATIONS MAY
BE NOTED AS "BLDG EL. _" OR "EL. _" OR "AFF. e") ANY ELEVATION NOT OTHERWISE DESIGNATED AS A SITE
LA
ELEVATION IS ON ANY PNS OTHER THAN THE SITE PLAN IS ASSUMED TO BE A BUILDING ELEVATION. SITE
ELEVATIONS MAY BE BASED ON THE SURVEY, WHICH MAY USE MEAN SEA LEVEL, NAVD, OR OTHER HEIGHT AS A
REFERENCE DATUM. SITE ELEVATIONS MAYBE NOTED AS: "SEL _" OR "_ NAVD" OR " +X.X' ". CONSULT ARCHITECT
FOR ANY QUESTIONABLE LOCATIONS PRIOR TO CONSTRUCTING.
12. AMBIGUITY:
12.1. IN THE EVENT OF ANY AMBIGUITY OR QUESTION WITH REGARD TO THE INTENT OF THE DOCUMENTS, THE ARCHITECT
SHALL INTERPRET THE CONSTRUCTION DOCUMENTS.
12.2. IN CASE OF CONFLICTS BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWINGS, CONSULT WITH ARCHITECT. IN
CASE OF CONFLICT BETWEEN THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS, CONSULT WITH ARCHITECT.
13. FLORIDA PRODUCT APPROVALS / SUBMITTALS / SHOP DRAWINGS:
13.1. THE SUBMISSION OF REQUIRED NOTICES OF ACCEPTANCE (NOA) / PRODUCT APPROVALS ARE THE RESPONSIBILITY
OF THE CONTRACTOR. THE CONTRACTOR IS REQUIRED TO MAKE THESE AVAILABLEATTIME OF INSPECTION. EVEN
IF THE ARCHITECT PROVIDES THESE THE CONTRACTOR MAY CHANGE TO A DIFFERENT PRODUCT THAT MEETS THE
SAME OR HIGHER BUILDING DESIGN PRESSURES, SOME JURISDICTIONS WILL REQUIRE A REVISION. IF THERE IS A
DISCREPANCY BETW THE FASTENING OF PRODUCTS, ACCORDING TO MFR INSTALLATION AND ARCHITECT'S SPECS,
VERIFY W/ ARCHITECT.
13.2. SHOP DRAWINGS/SUBMITTALS WILL BE REVIEWED FOR DESIGN CONFORMITY AND GENERAL CONFORMANCE TO
CONSTRUCTION DOCUMENTS ONLY. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING
DIMENSIONS AT JOBSITE FOR TOLERANCE, CLEARANCE, QUANTITIES, FABRICATION PROCESSESITECHNIQUES OF
CONSTRUCTION, COORDINATION OF HIS WORK WITH OTHER TRADES, AND FULL COMPLIANCE WITH CONSTRUCTION
DOCUMENTS.
14. GENERAL STRUCTURAL
14.1. ONCE SIGNED & SEALED BY ARCHITECT OR ENGINEER. DESIGN PROFESSIONAL CERTIFIES THATTHE CONSTRUCTION
DOCUMENTS MEET THE LOAD REQUIREMENTS STATED IN THE APPLICABLE FBC REFERENCED.
14.2. THE CONTRACTOR IS RESPONSIBLE FOR ALL METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION.
PROVIDE APPROPRIATE SUPERVISION THROUGHOUT THE PROJECT. CONSTRUCTION SITE SAFETY, INCLUDING ALL
ADEQUATE TEMPORARY BRACING AND SHORING, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IT IS THE
RESPONSIBILITY OF THE CONTRACTOR TO EMPLOY THE NECESSARY PROFESSIONAL SERVICES TO DETERMINE THE
NECESSARY METHODS AND SUPPORTS REGARDING FORMING AND CONSTRUCTION LOADS. TEMPORARY BRACING
AND SHORING SHALL BE DESIGNED TO RESIST ALL CONSTRUCTION LOADS INCLUDING THE WEIGHTS OF ALL
SUPPORTED MATERIALS PLUS A LIVE LOAD OF 50 PSF ON HORIZONTAL SURFACES. MAINTAIN TEMPORARY BRACING
AND RETAIN IN PLACE UNTIL PERMANENT STRUCTURAL SYSTEMS ARE CAPABLE OF RESISTING ALL CONSTRUCTION
PHASE LOADS.
14.3. THE CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS IN THE FIELD PRIOR TO F ABRICATIONAND START OF
CONSTRUCTION. THE CONTRACTOR SHALL PROTECT AND MAINTAIN ALL CONSTRUCTION AND ITS CONTENTS.
14.4. SPECIFIC PRODUCT DATAMUST BE PROVIDED TO ARCHITECT FOR APPROVAL OF HEAVY FINISHES SUCH AS TILE
ROOFS OR STONE ON RAISED FLOORS.
15. CAST -IN -PLACE CONCRETE
15.1, ARCHITECT OR ENGINEER OF RECORD TO BE NOTIFIED IN WRITING PRIOR TO POUR, TO GIVE ARCHITECT THE
OPTION TO INSPECT THE REINFORCEMENT FOR OVERHEAD BEAMS AND SLABS
15.2. CONCRETE PROPORTIONING, PLACING, FINISHING AND CURING SHALL BE AS PER THE LATEST EDITION OF THE PCA
MANUAL. LEAVE SUPPORT FOR ELEVATED CONCRETE IN PLACE UNTIL THE CONCRETE HAS REACHED ITS DESIGN
STRENGTH:
-OVERHEAD SLABS AND BEAMS TO BE 4000 PSI CONCRETE MIN UNO
-COLUMN AND WALL CONCRETE TO BE 3000 PSI CONCRETE MIN UNO
-FOOTINGS AND SLAB-ONI-GRADE TO BE 3000 PSI CONCRETE MIN UNO
-AUGERGAST PILE TO BE 5000 PSI CONCRETE MIN UNO
15.3. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 6 INCHES MAXIMUM AND 1 INCH MINIMUM EXCEPT FOR SLABS
ON -GRADE WHICH SHALL HAVE A MAXIMUM SLUMP OF 5 INCHES AND A MINIMUM OF 3 INCH,
15.4. COMPLY WITH ALL REQUIREMENTS OF ACI 117-10, ACI 318-14, ACI-315
15.5. ALL REINFORCING SHALL CONFORM TO ASTM 615 FOR GRADE 60 STEEL; WELDED WIRE MESH TO ASTM A-185.
ARRANGEMENT AND BENDING OF REINFORCING STEEL SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF
THE ACI DETAILING MANUAL AND THE CONCRETE REINFORCING STEEL INSTITUTE. DON'T SPLICE IN MIDDLE 1/3 OF
BEAM OR COLUMN SPAN, IF A SPLICE IN SPAN IS UNAVOIDABLE, FOLLOW DEVELOPMENT LENGTH/LAP DISTANCE IF
NOT NOTED VERIFY W/ ARCHITECT
15.6. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED
ITEMS SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC., PRIOR TO PLACING CONCRETE.
15.7. PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES.
START INITIAL CURING A' S) SOON AS FREE WATER HAS DISAPPEARED FROM THE CONCRETE SURFACE AFTER
PLACING AND FINISHING. KEEP CONTINUOUSLY MOIST FOR NOT LESS THAN 7 DAYS IN ACCORDANCE WITH ACI 301
PROCEDURES. PERFORM CURING OF THE CONCRETE BY CURING AND SEALING COMPOUND, BY MOIST CURING, BY
MOISTURE RETAINING COVER CURING OR BY COMBINATION THEREOF.
15.8. SEE THE DRAWINGS FOR. CONCRETE COVER FOR REINFORCING STEEL, BUT IN NO CASE SHALL THE COVER BE LESS
THAN THAT REQUIRED BY AC1318:
-CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH; 3"
-CONCRETE EXPOSED TO EARTH OR WEATHER: #5 BARS AND SMALLER, 1 1/2" INCHES; #6 BARS AND LARGER, 2"
15.9. CONCRETE SLAB ON GRADE CONTROL JOINTS SHALL BE AS SHOWN ON THE FOUNDATION PLAN OR TYPICAL
DETAILS. WHERE CONTROL JOINTS ARE NOT SHOWN ON PLANS, ALL CONCRETE SLABS ON GRADE SHALL BE BOUND
BY KEYED, DOWELED OR, SAW -CUT CONTROL JOINTS SUCH THAT THE ENCLOSED AREA DOES NOT EXCEED 260
SQUARE FEET. POST -TENSIONED CONCRETE SLABS ON GRADE SHALL NOT HAVE CONTROL JOINTS UNLESS
SPECIFICALLY NOTED ON THE PLANS. EXPANSION JOINT FILLER SHALL BE NON -EXTRUDED PREMOLDED MATERIAL
OF ASPHALT IMPREGNATED FIBERBOARD (ASTM D1751)
15.10. CONSTRUCTION JOINTS OR POUR JOINTS IN STRUCTURAL ELEMENTS (BEAMS, COLUMNS, ELEVATED SLABS, ETC.)
NOT SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS REQUIRE PRIOR APPROVAL OF THE ARCHITECT.
CONTRACTOR SHALL SUBMIT SHOP DRAWINGS SHOWING PROPOSED JOINTS TO ENGINEER FOR APPROVAL.
15.11. ALL CONCRETE SHALL UTILIZE A MINIMUM OF 20% FLY ASH CONTENT.
15.12. VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SHOWN ON THE DRAWINGS. PLACE VERTICAL
REINFORCING BARS AT CORNERS, JAMBS OF OPENINGS, BELOW BEAM BEARING, AND IN WALLS AS INDICATED ON
THE DRAWINGS. VERTICAL WALL REINFORCING BARS SHALL EXTEND CONTINUOUS I=ROM FOUNDATION INTO TOP
BOND BEAM. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC LINO.
-TIES/STIRRUPS TO STARTATA DISTANCE FROM SUPPORT OF 1/2 TIE SPACING
15.13. NO HOLES, CHASES, OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THK STRUCTURAL DRAWINGS
SHALL BE MADE IN CONCRETE MEMBERS WITHOUT ARCHITECT'S APPROVAL.
16. CONCRETE MASONRY:
16.1, CMU DESIGNED AND TO BE IN ACCORDANCE ACI 530-13/ASCE 5-13/TMS 402-13, "BUILDING CODE REQ FOR
MASONRY STRUCTURES", "COMMENTARY ON BUILDING REQ FOR MASONRY STRUC
TURES".
16.2. MASONRY STRENGTH (fm DESIGN) UNO:
-BLOCK STRENGTH = 1900, ASTM C90
-MORTAR STRENGTH = 1800, TYPE S
-GROUT STRENGTH = 2000
16.3. GROUT SHALL HAVE A SLUMP OF 8 TO 11 INCHES, BE IN CONFORMANCE WITH ASTM C 476-02 AND ATTAIN A
COMPRESSIVE STRENGTH OF 3000 PSI. GROUT SHALL. CONFORM TO REQUIREMENTS OF FLBC STANDARDS.
USE SUFFICIENT WATER FOR GROUT TO FLOW INTO ALL JOINTS OF THE MASONRY WITHOUT
SEGREGATION. ALL CELLS IN CONCRETE BLOCKS CONTAINING REINFORCING SHALL BE FILLED SOLID WITH
GROUT. ALL MASONRY BELOW FINISHED FLOOR OR GRADE SHALL BE GROUTED SOLID. HOLD GROUT
DOWN 1-1/2" BELOW TOP OF BLOCK AT GROUT LIFT JOINTS AND AT CONCRETE PLACED OVER MASONRY.
16.4. CONCRETE MASONRY UNITS SHALL BE PLUMB, TRUE TO LINE, WITH LEVEL COURSES ACCURATELY SPACED
AND BUILT TO THE THICKNESS AND IN A RUNNING BOND AS INDICATED AND CONFORMING TO THE
TOLERANCES SPECIF
IED IN ACI 531
.1 AND 530.1.
16.5. REINFORCING BARS SHALL BE PLACED IN THE MIDDLE OF THE CELLS, UNLESS NOTED OTHERWISE, AND
TIED OR OTHERWISE SECURELY SUPPORTED AT THE TOP AND BOTTOM TO ENSURE THAT THE BAR DOES
NOT MOVE DURING GROUTING.
16.6. MORTAR DROPPINGS AND OTHER DEBRIS MUST BE KEPT OUT OF CELLS WHICH ARE TO BE GROUTED.
16.7. CONTROL JOINTS SHALL BE PROVIDED IN ACCORDANCE WITH THE LOCATIONS AND DETAILS SHOWN ON
THE DRAWINGS. CONTROL JOINTS SHALL NOT EXTEND THROUGH THE TOP BOND BEAM COURSE. THE
JOINTS ON BOTH SIDES OF THE WALL SHALL BE SEALED AND TOOLED SMOOTH.
16.8. WALL REINFORCEMENT: VERTICAL AND HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SPECIFIED
ON THE DRAWINGS. DESPITE IF SHOWN ON DRAWINGS- PLACE VERTICAL REINFORCING BARS AT
CORNERS, EA CELL WITHIN 16" OF CORNER, JAMBS OF OPENINGS, EA CELL WITHIN 16" OF JAMBS FOR
OPENINGS WIDER THAN 12', BELOW BEAM BEARING, BELOW GIRDER TRUSS BEARING, AND IN WALLS AS
INDICATED ON THE DRAWINGS. IF NOT SPECIFIED IN TEXT ON DRAWINGS USE #5 @ 48" OC. WALL
REINFORCING BARS SHALL EXTEND CONTINUOUS FROM FOUNDATION INTO TOP BOND BEAM. MIN LAP
SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO. 8" TOLERANCE ALLOWED
FOR WALL REINF SPACING. SEE DOWEL NOTE 17.2 BELOW.
16.9. REINFORCED MASONRY LINTELS SUCH AS CAST CRETE TO BE INSTALLED AS PER MFR INSTRUCTIONS.
LINTELS TO HAVE 4" MINIMUM BEARING. CONTINUOUS REINF ACROSS COLUMNS. IF SPECIFIED, OA LINTEL
LENGTH IS +/- AS LONG AS MIN BRIG IS MET. DOOR/WINDOW LINTELS CAN BE DEEPER(TALLER) THAN
SPECIFIED BUT NOT SHORTER.
16.10. LINO HORIZ JOINT REINFORCEMENT @ 16" OC IN MASONRY WALLS IS SUGGESTED BUT NOT REQUIRED TO
CONTROL CRACKING.
16.11. BOND/TIE BEAMS/LINTELS- CONTINUE REINFORCING BARS CONT (UNINTERRUPTED) AROUND ALL
CORNERS, OVER OPENINGS, ACROSS WALL INTERSECTIONS, THROUGH TIE COLUMNS, AND UP/DOWN AT
CHANGES IN BOND BEAM ELEVATION.
16.12. ALTERNATE WINDOW SILL: 4"H MIN x 8"W CAST CONC W/ (1) # 5 EXTENDED 4" INTO FILLED JAMB CELLS.
17. FOUNDATIONS:
17A. BUILDING AREA TO BE STRIPPED/GRUBBED OF SURFACE DEBRISNEGITATION. FILL TO BE CLEAN
GRANULAR & UNIFORMLY COMPACTED TO 95% DENSITY (ASTM D 1557) AND MEASURED IN 12" LIFTS. AT
DISCRETION OF CONTRACTOR OR BLDG INSPECTOR, ARCHITECT RECOMENDS SOIL TO BE TESTED BY
GEOTECH ENGINEER TO ENSURE MINIMUM SOIL BEARING PRESSURE CAPACITY & RECOMEND SITE PREP.
17.2.. DOWEL VERTICAL REINFORCING BARS OUT OF THE FOUNDATION OR STRUCTURE BELOW WITH BARS OF
THE SAME SIZE AND SPACING OF WALLABOVE. THERE SHALL BE A DOWEL FOR EACH VERTICAL
REINFORCING BAR. MIN LAP SPICES, EMBEDMENT, AND END HOOK LENGTHS AS PER ACI 318 OR FBC UNO.
For #5: MINIMUM 30" LAP W/ 10" HOOK LINO. SEE WALK_ REINFORCEMENT NOTE 16.8 ABOVE. FOR MISSED
EMBEDDED DOWEL, EPDXY EMBED W! 1/8" OVERSIZED HOLE DIA., 6" EMBED W/ CLEAN HOLE.
17.3. BUILDING SLABS -ON -GRADE TO BE REINFORCED WITH 6x6 10/10 WWF MIN WITH MESH UP CHAIRS OVER 6-
MIL MINIMUM POLYETHYLENE FILM VAPOR RETARDER OVER TERMITE TREATED COMPACTED GRADE UNO.
SUGGESTION TO PROVIDE DIAGONAL 36" #4 REBAR ATALL INSIDE 'REENTRANT CORNERS.
17.4. CONTINUOUS FOOTINGS, STEM OR MONOLITHIC, TO BE REINFORCED CONTINUOUS, WITH LAPS AS PER
STATED DEVELOPMENT LENGTH IF NOTED OR 48x BAR DIAMETER MIN UNO. 30" MIN CORNERS BARS TO
MATCH LONGITUDINAL REBAR.
17.5. SUGGESTION TO PROVIDE A 4-INCH MEDIUM TO COARSE SAND OR GRAVEL COMPACTED DRAINAGE FILL
BELOW ALL INTERIOR SLABS -ON -GRADE.
17.6. SOIL AND SUBGRADE IS TO BE TERMITE TREATED.
17.47. SLAB FINISHES UNO:
MAIN BUILDING: STEEL TROWEL FINISH
-GARAGE: STEEL TROWEL, THRESHOLD: LIGHT BROOM
-DRIVEWAY, DRIVEWAY APRON, PORCHES/PATIOS LIGHT BROOM
17.8. GARAGE, AND ALL EXTERIOR HARD SURFACES TO SLOPE AWAY FROM BLDG MIN 1/8"/FT.
17.9. CONCRETE PADS FOR VIBRATING EQUIPMENT SUCH AS PUMPS OR MOTORS TO HE SEPARATED FROM
HOUSE SLAB WITH A MINIMUM OF AN ASPHALT EXPANSION JOINT.
17.10. RECESS SGD & GARAGE DOOR THRESHOLDS 3/4"- VERIFY EXACT DIMENSIONS WITH SUPPLIER/MFR.
17.11. COLUMN/WALLAND FOOTING CENTERLINES SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE.
17.12. SLOPE GRADES AWAY FROM BUILDING ON ALL SIDES A MINIMUM OF 6" OVER 101. 4:1 SLOPE MAX.
18. STRUCTURAL STEEL:
18.1. ALL STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A-36 AND THE "SPECIFICATION FOR THE
DESIGN, FABRICATIONAND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" BY THE AMERICAN
INSTITUTE OF STEEL CONSTRUCTION. ALL STEEL PIPE SHALL CONFORM TO ASTM A-53, TYPE E (Fy = 35
KSI).
18.2. ALL SHOP CONNECTIONS TO BE WELDED AND FIELD CONNECTIONS TO BE BOLTED UNLESS OTHERWISE
SPECIFICALLY NOTED ON THE STRUCTURAL DRAWINGS. ALL WELDING IN ACCORDANCE WITH AWS D1.1
"STRUCTURAL WELDING CODE". USE E70XX ELECTRODES UNO.
18.3. ALL STEEL TO RECEIVE ONE SHOP COATAND ONE FIELD TOUCHUP COAT OF APPROVED PAINT.
18A. ALL BOLTED CONNECTIONS SHALL CONSIST OF ASTM A325 HIGH STRENGTH BOLTS AND HARDENED
WASHERS AS SHOWN ON THE STRUCTURAL DRAWINGS. ALL BOLTED CONNECTIONS SHALL CONFORM TO
THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" BY THE AMERICAN
INSTITUTE OF STEEL CONSTRUCTION.
18.5. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A36 OR A307 (THREADED ROD).
18.6. SUBMIT SHOP DRAWINGS FOR REVIEW OF CONFORMANCE TO DESIGN CONCEPT.
1&7. GROUT FOR COLUMN BASE PLATES SHALL BE NON -SHRINK GROUT 5000 PSI MINIMUM.
19, LIGHT GAGE METAL STUDS & MISC. METAL FRAMING:
19.1. ALL LIGHT GAGE METAL INTERIOR STUDS SHALL BE G90 GALVANIZED 25 GA MINIMUM. USE 20 GA STUDS
WHERE HEAVY LOADS ARE HUNG FROM SUCH AS TV"S OR WALL CABINETS. ALL WALL TRACKS SHALL BE 25
GA.
20. HVAC:
20.1. PLANS ARE SCHEMATIC. EXACT LAYOUTISIZING OF UNITS, DUCTS, RETURN AIR GRILLES AND SUPPLY
GRILLES ETC, SHALL BE DETERMINED BY HVAC LICENSED CONTRACTOR. IF LAYOUT/SIZING IS PROVIDED
HVAC CONTRACTOR TO VERIFY.
20.2. PROVIDE MANUFACTURED CONCRETE PADAND BRACKETS RATED FOR SPECIFIED WIND LOAD FOR
CONDENSING UNIT. FOR MOUNTING AND SECURING MECHANICAL EQUIPMENT, REFER TO THE
MANUFACTURER'S SPECIFICATIONS.
21. WOOD FRAMING
21.1. ALL STRUCTURAL (LOAD BEARING) LUMBER SHALL BE S.Y.P. OR DOUGLASS FIR, GRADE #2, KID 19% (Fb FOR
LUMBER SIZES NOTED TO BE IN CONFORMANCE WITH VALUES LISTED IN THE NATIONAL FOREST
PRODUCTS ASSOCIATION NATIONAL DESIGN STANDARD SUPPLEMENT TABLE 4B), AND SHALL CONFORM TO
THE NATIONAL GRADING RULE FOR DIMENSION LUMBER, THE SOUTHERN PINE INSPECTION BUREAU AND
THE SOUTHERN FOREST PRODUCTS ASSOCIATION. ALL NON -LOAD BEARING FRAMING LUMBER (INTERIOR
WALLS) TO BE #2 S.P.F. OR BETTER.
21.2. ALL WOOD MEMBERS IN CONTACT WITH CONCRETE AND/OR MASONRY TO BE PRESSURE TREATED. ALL
WOOD EXPOSED TO THE WEATHER OR IN CONTACT WITH THE GROUND TO BE PRESSURE TREATED TO 0.80
CCA.
21.3. SPLICING FOR MULTI -PLY HEADERS/BEAMS/COLUMNS:
-2x4- 10d COMMON NAIL @ 6" OC EACH LAYER STAGGERED.
-2x6- 2 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER.
-2x8- 3 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER.
-2xl0- 4 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER.
-2xl2- 5 ROWS 10d COMMON NAIL @ 12" OC EACH LAYER.
-LOCATE SPLICES OVER BRG SUPPORTS. GLUE BETW LAYERS. USE 16D IF 1/2" PLY SPACER USED
21.7. END STUDS OF EXTERIOR FRAME WALL OR DESIGNATED INTERIOR SHEAR WALLS TO ATTACH TO CONC
WALL W/ .25" x 3.25" TAPCON @ 16" OC/8" ENDS. FOR INTERIOR BRIG WALLS USE 1/4" x 2.75" TAPCON @ 32"
OC/8" ENDS.
21.8. ALL WOOD NAILING AS PER FBC R 602.3 UNO.
22. PLYWOOD SHEATHING:
22.1. ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING. INSTALL PLYWOOD WITH FACE GRAIN PERPENDICULAR
TO SUPPORTS, PROVIDE BLOCKING AT PANEL EDGES WHERE INDICATED ON THE PLANS.
22.2. UPPER PANELS TO BE ATTACHED TO THE TOP MEMBER OF THE UPPER DOUBLE TOP PLATE AND TO RIM
JOIST AT BOTTOM OF WALL, PROVIDE BLOCKING FOR ALL EDGE NAILING OVER LENGTH OF PLYWOOD
22.3. FOR EXTERIOR AND INTERIOR SHEAR WALLS USE 1/2" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE
NAILS 6" FIELD, 6" EDGE, 4" EDGE WITHIN 4' OF CORNERS. NAIL SPECS: ASTM F1667 RSRS-03 (2'/z" x 0.131")
22.4. FOR ROOF USE 5/8" PLYWOOD AND 8d RINGSHANK GALV NAILS. SPACE NAILS 6" FIELD, 6" EDGE, 4" EDGE
WITHIN 4' OF EAVES/RIDGES/GABLES.
22.5. FOR SUBFLOOR USE 3/4" PLYWOOD AND 2.5" #8 SCREWS & GLUE OR 8d RINGSHANK GALV NAILS & GLUE.
SPACE FASTENERS 6" FIELD, 6" EDGE.
22.6. FOR ATTIC FLOOR USE 5/8" PLYWOOD AND 6d RINGSHANK GALV NAILS. SPACE NAILS 12" FIELD, 12" EDGE.
ONLYALLOWED WHERE TRUSS ENGINEERING SPECIFIES.
23. PE TRUSSES:
ABBREVIATIONS:
23.1.
FIELD VERIFY WITH ARCHITECT EXACT LOCATION AND CONFIGURATION BEFORE MODIFYING EXISTING
TRUSSES. DO NOT CUT ANY FRAMING MEMBERS OR TRUSSES WITHOUT EXPRESS WRITTEN AUTHORITY
AB
ANCHOR BOLT
FROM THE ENGINEER AND ARCHITECT.
A/C
AIR CONDITIONER
23.2.
FIELD VERIFY DIMENSIONS OF NEW PRE-ENGINEERED TRUSSES PRIOR TO CONSTRUt',TING.
AHU
AIR HANDLING UNIT
23.3.
CONTRACTOR TO SUBMIT THE TRUSS ENGINEERING TO ARCHITECT TO REVIEW FOR ADHERENCE WITH
AT
ACOUSTICAL TILE
DRAWINGS PRIOR TO CONSTRUCTION. ARCHITECT'S SEAL WILL NOT BE APPLIED.
B.M.
BENCH MARK
23.4.
TRUSS CONFIGURATION DRAWN ARE SCHEMATIC ONLY, HOWEVER THE SUPPORTING STRUCTURE HAS
BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL
BM
BEAM
FINAL LAYOUT MY MFR. EXACT TRUSS WEB, CHORD SIZES AND LAYOUTARE TO BE DETERMINED BY THE
BC
BOTTOM CHORD
MFR. TRUSS MFR TO DESIGN ANY PERMANENT BRACING REQUIRED FOR STABILITY.
BLK
BLOCK
23.5.
ALL TRUSSES FURNISHED SHALL BE SUPPLIED WITH SIGNED AND SEALED TRUSS DIAGRAMS PROVIDING
BO
BY OWNER
THE MFR'S TRUSS SPECIFIC REQUIREMENTS FOR BRACING AND LATERAL MOVEMENT. ALL TRUSS-10-
BOTTOM
TRUSS CONNECTORS TO BE SUPPLIED BY THE TRUSS MFR. VERIFY THAT THE CAPACITY OF THE TRUSS
BP
BP
BOTTOM PLATE
ANCHORS CALLED OUT ON THE CONSTRUCTION DRAWINGS MEET OR EXCEED THE UPLIFT VALUES ON
CJ
CONTROL (CONSTRUCTION) JOINT
THE TRUSS ENGINEERING.ANY TRUSS ANCHORS CALLED OUT THAT ARE OF INSUFFICIENT CAPACITY
SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR SUBSTITUTION.
CL
CENTER LINE
23.6.
BRACE BOTTOM CHORD AS PER MFR SPECS, IF NOT PROVIDED, PROVIDE CONTINUOUS 'RAT RUN'
CLG
CEILING
LATERAL BRACE PERPENDICULAR TO BC 2x4 @ 12' OC (2) 12d NAILS EA BC.
CLR
CLEAR
23.7.
PREFABRICATED WOOD TRUSSES, JOISTS, AND GIRDER TRUSSES SHALL BE DESIGNED TO SUPPOR-r
CMU
CONCRETE MASONRY UNIT
THEIR SELF -WEIGHT, PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. INCLUDING, BUT NOT LIMI TED
CO
CONNECTOR
TO, WALLS EITHER PARALLEL OR PERPENDICULAR TO THE SPAN, ALL MECHANICAL AND OTHER
COL
COLUMN
EQUIPMENT, AND SHALL DESIGNED TO RESIST ALL DRAG FORCES, SHEARWALL UPLIFT AND DOWNVvARD
CONC
CONCRETE
LOADS, AND OTHER SPECIAL LOADS NOTED ON STRUCTURAL, MECHANICAL, PLUMBING, OR
C
CU
CONTINUOUS
CONDENSING UNIT OR COPPER
ARCHITECTURAL DRAWINGS OR CALCULATIONS. MINIMUM ALLOWABLE SHEAR SHALL BE 95 PSI,
CW
COLD WATER
BRIDGING SIZE AND SPACING SHALL BE AS DESIGNATED BY TRUSS MFR UNLESS NOTES OTHERWISE.
CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, ERECTION DRAWINGS AND DESIGN CALCULATIONS
CXN
CONNECTION
SEALED BY A REGISTERED ENGINEER. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED
D
NAIL SIZE (PENNY)
AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICBO APPROVAL. THE MFR SHALL DESIGN
CONNECTION OF TRUSS REQUIRING PREFABRICATED HARDWARE HANGER OR OTHER.
DF
DRINKING FOUNTAIN
23.8.
FABRICATOR TO SUBMIT SHOP DRAWINGS AND CALCULATIONS FOR ALL ELEMENTS OVER SIGNATURE
DIA
DIAMETER
AND SEAL OF FLORIDA ENGINEER (SPECIALTY ENGINEER). SPECIALTY ENGINEER MAY SUBMIT
DIM
DISP
DIMENSION
DISPOSAL
PREFERRED CONNECTION AND OTHER DETAILS IF DIFFERENT FROM SAME ON DRAWINGS FOR
DN
DOWN
APPROVAL.
DR
DRYER
24. CONNECTORS/FASTENERS:
DTL
DW
DETAIL
DRIVEWAY
24.1.
CONNECTORS BY SIMPSON OR APPROVED SIMILAR TO BE HDG OR ZMAX COATED IF UNEXPOSED TO
WEATHER AND TO BE STAINLESS STEEL IF EXPOSED TO WEATHER UPON COMPLETION.
'E'
EXISTING
24.2.
UPLIFT CONNECTORS MAY BE SUBSTITUTED WITH CONNECTORS WITH >_ THE DOCUMENTED UPLIFT
VALUE IS >_ SPECIFIED CONNECTOR. UNLESS SPECIFIED UPLIFT CONNECTORS ARE NOT REQUIRED ,DN
EA
EACH
LOADBEARING WALLS THAT ARE NOT SUBJECT TO UPLIFT OR SHEAR. SPACE NAILS AT STRAPS AS TO
EJ
EXPANSION JOINT
NOT SPLIT WOOD, USE MINIMUM NAIL QTY REQUIRED BY MFR. IF MULTIPLE FASTENER OPTIONS USE
EL
BUILDING ELEVATION
EITHER UNLESS SPECIFIED BY ARCHITECT.
ELECT
ELECTRICAL
ELEV
ELEVATOR OR ELEVATION
26. EXTERIOR DOORS AND WINDOWS:
EW
EWC
EACH WAY
ELECTRIC WATER COOLER
26.1.
INSTALL OVERHEAD DOORS (INCLUDING BUCKS), EXTERIOR DOORS, AND WINDOWS AS PER MFR'S
EWH
ELECTRIC WATER HEATER
SPECIFICATION/ PRODUCT APPROVAL.
EXP
EXPOSED
26.2.
PT 1x BUCK: ATTACH TO MASONRY/CONC W/ADHESIVE & RECESSED 3/16"x2" MIN TAPCON OR 6D CASE
HARD NAILS OR T NAILS @ 12"A" END. PT 2x BUCK: ATTACH TO MASONRY/CONC W/ADHESIVE &
EXT
EXTG
EXTERIOR
EXISTING
RECESSED 1/4"x3 1/4" MIN TAPCON @ 12"A" END,
26.3.
MIN OVERHEAD DOOR BUCK: 2x6 @ SIDES TO FILLED CELL W/ WEDGE ANCHOR @ 24" OC MIN, 12" FROM
F1
FOOTING #1
ENDS. WEDGE ANCHOR TO BE 1/2" x 6" W/ 2" x 1/8" WASHER. 2x6 @ TOP TO LINTEL W/ 1/4" x 2.75"
TAPCONS STAG 24" OC.
�o
FA
FASTENER
26.4.
CONTRACTOR TO VERIFY THE FOLLOWING WITH MFR/SUPPLIER PRIOR TO CONSTRUCTION:
FD
FIELD {FLOOR} DRAIN
-ROUGH OPENING DIMS, EGRESS COMPLIANCE (FBC R310), SAFETY GLASS COMPLIANCE (FBC R308A)
FE
FIRE EXTINGUISHER
26.5.
CONTRACTOR TO FIELD VERIFY OPENINGS BEFORE ORDERING DOORS/WINDOWS.
FF
FINISH FLOOR
26.6.
DOORS BETWEEN GARAGE & RESIDENCE TO BE 20 MINUTE FIRE RATED OR 1-38" THICK SOLID WOOD AS
FIN
FINISH
FLR
FLOOR
PER FBC R 302.5.1.
FP
FIRE PROTECTION
26.7.
FLASHING AS PER FBC R703.4 AND REFERENCED FMA/AAMA DOCUMENTS.
EPS
EXPANDED POLYSTYRENE
26.8.
GLASS TO HAVE: LOW-E, U-FACTOR 5 0.4, SHGC 5 0.25
FTG
FOOTING
26.9.
SIZES ARE NOMINAL AND CAN VERY +/- 2" IN SIZE IF EGRESS IS NOT EFFECTED.
FT
FOOT (OR FEET)
27. ELECTRICAL & LIGHTING NOTES
GALV
GALVANIZED
27.1.
PLANS ARE SCHEMATIC. EXACT LAYOUT/SIZING OF CIRCUITS, RECEPTACLES, FIXTURES, AND
EQUIPMENT, SHALL BE DETERMINED BY AN ELECTRICAL_ CONTRACTOR. IF LAYOUT/:SIZING IS PROVIDED
GFI
GROUND FAULT INDICATOR
TO VERIFY.
ELECTRICAL CONTRACTORGWH
GSF
GROSS SQUARE FEET
27.2.
ALL 120V 15AAND 20A DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER -RESISTANT TYPE.
GAS WATER HEATER
27.3.
PROVIDE AFIC AS DETERMINED BY NEC 210.12 OR FBC R 3902.
GWB
GYPSUM WALL BOARD
27.4.
PROVIDE GFIC AS DETERMINED BY NEC 210.8 OR FBC R 3902,
2T5.
ALL EXTERIOR OUTLETS TO BE GFIC WITH WEATHER TIGHT PROTECTIVE COVER.
HB
HOSE BIB
27.6.
SMOKE ALARMS SHALL BE HARD WIRED, INTERCONNECTED, W/ BATTERY BACKUP PER FBC R314.
HC
HOLLOW CORE
27.T
CARBON MONOXIDE ALARM TO BE INTEGRAL WITH SMOKE ALARM AND COMPLY WITH FBC R315.
HDG
HOT DIPPED GALVANIZED
27.8.
PROVIDE POWER RECEPTACLE & LIGHT, WHEN ATTIC CONTAINS AHU OR HAS STORAGE AREA.
HORIZ
HORIZONTAL
HW
HOT WATER
28.
PLUMBING:
HWH
HOT WATER HEATER
28.1.
PLANS ARE SCHEMATIC. ACTUAL LOCATION, MATERIAL, AND SIZE OF PIPES, DRAINS, AND VENTS SHALL
BE DETERMINED BY A LICENSED PLUMBER. IF LAYOUT/SIZING IS PROVIDED PLUMBING CONTRACTOR TO
IN
INCH
VERIFY.
INT
INTERIOR
28.2.
T IZING SHALL BE BY A LICENSED SEPTIC
SEPTIC &DRAIN FIELD IS SCHEMATIC, EXACT LAYOU !S S
CONTRACTOR AND ADHERE TO 64E-6, F.A.C.
JT
JOINT
28.3.
NO PLUMBING REQUIREMENTS SHALL INTERRUPT THE STRUCTURAL INTEGRITY OFT HE BUILDING.
MAX
MAXIMUM
29.
ROOF PENETRATIONS:
MEP
MECH/ELECT/PLUMB
29.1.
VERIFY ALL REQUIRED ROOF PENETRATIONS FROM HVAC, PLUMBING, ELECTRICAL, AND OTHER
MFR
MANUFACTURER
DRAWINGS. PROVIDE ALL NECESSARY PENETRATIONS WITH REQUIRED ACCESSORIES TO PREVENT-
MIN
MINIMUM
MOISTURE INTRUSION AND RETAIN STRUCTURAL STABILITY, IN ADDITION TO THOSE INDICATED ON THE
MO
MASONRY OPENING
ROOF PLAN. CONSULT ARCHITECT IF ROOF PLAN CONFLICTS WITH ANY REQUIRED ROOF PENETRATIONS.
MW
MICROWAVE
31.
FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX:
NIC
NOT IN CONTRACT
31.1.
FLAME SPREAD INDEX & SMOKE DEVELOPED INDEX:
NTS
NOT TO SCALE
31.2.
FINISHES TO COMPLY WITH THE BELOW FIGURES AS PER FBC R302.9 - 302.10
NSF
NET SQUARE FEET
31.3.
INSULATION FLAME SPREAD: <25, INSULATION SMOKE DEVELOPED: <450
31.4.
WALL/CLG FLAME SPREAD: <200, WALL/CLG SMOKE DEVELOPED: <450
LF
LINTEL #1
LF
LINEAL FOOT
32.
CLIMATIC & GEOGRAPHIC DESIGN CRITERIA:
32.1.
WEATHERING: NEGLIGIBLE, TERMITE AREA: VERY HEAVY
OA
OVERALL
OC
ON CENTER
33.
MISC:
OAS
OR APPROVED SIMILAR
33.1.
ROOF SYSTEM & FLASHING AS PER MFR INSTRUCTIONS.
3o,�ARDRAI
a F13G R312
PL
PROPERTY LINE OR PLATE
AS PER
-r
cntlotntlnvnc oco core o��tl� �
PLY
PLYWOOD
38.3.
� PER FBG R322.1.6.
PT
PRESSURE TREATED
33.4.
33.5.
MEP SYSTEMS!' BF-E, oco
MECHANICAL APPLIANCES TO BE PROTECTED IF INSTALLED ON FLOOR IN GARAGE AS PER M1307.3.1.
PVC
POLYVINYL CHLORIDE
USE 2" DIA x 36"H PIPE W/ COLLAR BASE, ATTACH COLLAR TO SLAB W/ (4) 1/4" x 2.25" TAPCON.
33.6.
CAULK BOTTOM OF SOLE PLATE AT GARAGE COMMON FRAME WALL.
R
RADIUS
33.7.
IGNITION BARRIER NOT REQUIRED FOR SPRAY FOAM IN ATTIC UNO.
R/A
RETURN AIR
33.8.
PROVIDE FIRE BLOCKING AS PER FBC R 302.11.
RCB
REINFORCED CONCRETE BEAM
83.9.
RCC
REINFORCED CONCRETE COLUMN
AS PER F13G
RD
ROOF DRAIN
THAN 1,0008F •
REF
REFRIGERATOR
34.
FINISHES:
REINF
REINFORCING
34.1.
GWB: MOISTURE RESISTANT GWB @ ALL WET AREAS, CEMENT BOARD INSIDE SHOWER COMPARTMENTS.
REQ
REQUIRED
USE 5/8" TYPE X GWB ON GARAGE CEILING IF CONDITIONED/HABITABLE AREAABOVE. GARAGE
RAN
RIGHT-OF-WAY
SEPARATION WALL TO HAVE A MINIMUM OF ONE 1/2" LAYER OF GWB ON THE GARAGE SIDE OF WALLAS
RTU
ROOF TOP UNIT
PER FBC R302.6. SEE DOOR GEN NOTE 26.6.
34.2.
-1 A. FOR EXTERIOR CEILINGS/SOFFITS S/SOP TM C1063 1 O E G FIT E MIN. 5/8" LATH PER FBC R703.7.1/AS SUS
EXTERIOR LA AS
S.
SIMPSON (MFR)
STUCCO ON RIBBED LATH. ATTACH TO BOTTOM OF WOOD FRAMING W! 11GA NAILS W/ 3!8" HEAD @ 6" OC
SBS
STYRENE BUTADIENE STYRENESEL
W/ 1-3/4" EMBED INTO WOOD. TYP TRANSITION FROM WOOD TO CONC (I.E. @ GABLE END) TO HAVE: A
SITE ELEVATION
VINYL CONTROL JOINT IN STUCCO.
SF
SQUARE FOOT
34.3.
EXTERIOR T&G WOOD CEILING. ATTACH 1x4 OR 1x6 BOARD W/ 2" 16GA FINISH NAIL EA RAFTER/JOIST/BC.
SF
SIMILAR
TO CHANGE ORIENTATION USE 2x4 FLAT PURLINS ATTACHED TO EA RAFTER/JOIST/BC W/ (2)16D NAIL..
SK
SINK
SOG
SLAB ON GRADE
SS
STAINLESS STEEL
STAG
STAGGERED
TBD
TO BE DETERMINED
TC
TOP CHORD
THE
TO MATCH EXISTING
TOB
TOP OF BEAM
TOB
TOP OF COLUMN
TOS
TOP OF SLAB
TP
TOP PLATE
TPO
THEROO PLASTIC OLEFIN
TYP
TYPICAL
UG
UNDER GROUND
UNO
UNLESS NOTED OTHERWISE
VB
VAPOR BARRIER
VERT
VERTICAL
VTR
VENT THRU ROOF
W/
WITH
WA
WASHER MACHINE
WP
WATERPROOF
WD
WOOD
WWF
WELDED WIRE FABRIC/MESH
# POUND OR NUMBER
QD
I`
0 T
E
O
E j
L =
a � T_
-
6 (U
N m c- _ CL
_ = OJNp N
Cc
.0 v � 0 C
- C W ,z) E -a
•=_ Q CL 5 It -
rn f,9 r V �
_ c 'N co
Im24)IMNC
�) v p _ c, OZ . n
0♦ , YI0
O �
CU LL
CK
U
U
w
cc
a
U
LL
U
w
a
a)
V)
x
F-
m
0
0
w
IL
0
J
>
ILl
0
0
a
0
w
J
WW
0
w
C.)
CV
F-
z
DO
0)
U
w
W
W
W 0
CY)
o
z
V
-J
v
'mot
Z
LL
U.]W
a
W �
[L
z
in
a J
I.
m
z
IIIIIIIIIIIIIIIIIIIIIIII
0
w
W Q
0
o
W LL
0�
W
Z
� i
4_J
(1)
w
IL
0
J
Z V
E
w
x
- Z
U)
3:
M
a-
w
a
W
w
J,
x
D)
0
W
W
I-
z
o
0
Z
IIIa
U
0
z
r
z
w
2
w
0
I
<
0
to
z
a
vi
z
2
In
w
d0
W
0
J
<
0
F_
Z
W
O
W
Q
0
0
general notes
8/27/21
SHEET
GN-1
%P•. ...0
o. ' NCtS P. UFez '."9
:• QZ 6` .
.:( -*- �.
_ _ AR97108 :,
)A
� =LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that zhDo not stand on trusses until they are braced per BCSf &properly nailed to straps and hangers ! !
should be read and given special attention to all WITH CRANE OPERATOR ADVANCE FOR A SPREADER BAR OF 41' -
ersons installing trusses. &ARRANG O O R I 46 I N LENGTH!!
SPACING NOTE
All trusses are to be set 2'-0" on 61-08-00__ _
center except as noted.
5-04-00 3-08-00 10-08-00 3-08-00 38-04-00
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE A.- 11
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY. u Jti
c I
i o
4s
o 1\1��
o
p R 1
�kr
GR S XJU
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Sp n or less
60 degrees
or less
er Bar
to
Tag line E� 112 span —� Tag line —'�21 p n. ��►
approx. U2 of Span.
REFER TO BCSI REFER TO BCSI
Truss must be set this way if crane is used. Truss must be set this way if crane is used.
Truss is an example, your truss may not match. Truss is an example, your truss may not match.
Insist crane operator sets truss this way. Insist crane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
are installed. I
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
WARNING
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
REPRESENTS THE LEFT SIDE OF
EACH TRUSS DRAWING
�r ~TF?IISS
SEAT PLATES BY CHAMBERS TRUSS
IL, REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN
CARRYING
TRUSS
HANGER ID
112-10d
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
N
GR2
THD26
x1 1/2
18-16d
*Please refer to Standard Engineering package for general instuction on installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1 /2"
Hatch Legend
WALL HEIGHT V-411
l
5-00-00
5-00-00
GR3
Al
I-
61-08-00
2-02-08
1
C�Z�L
A
5-00-00
'. HIP CARRIER LOCATED AS DIMENSIONED ON LAYOUT
FABRICATION
TRUSSES CANNOT BE STARTED
AGREEMENT
UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The undersigned acknowledges and agrees:
CORNDER JACKS
1. Trusses will be made in strict accordance wi
this truss placement diagram layout, which is the sole authority for
ARE NOT BEVELED. ''
SEE STANDARD
determining successful fabrication of the trusses.
I ENGINEERING. pY
2. All dimensions in this layout have been verifie
I by the undersigned.
3. Unless written notice is provided by certi
ed mail to Chambers Truss within ten (10) days of delivery the
undersigned agrees that no backcharges will be al
owed. In the event such written notice is furnished Chambers Truss
;shall have three (3) business days in which to begi
repairs required, or to substitute other trusses, at Chambers option.
After 10 days of delivery remedy will be according
Florida statute 558.
4. The undersigned acknowledges receipt of "BCSI'
summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyer's respon
ibility to make the job site suitable for delivery. Chambers Truss has
i
the sole authority to determine the suitability of the
job site or a portion of the job site for delivery. Chambers Truss will I
be responsible for dump delivery only. The buyer i
responsible for additional delivery expenses if Chambers Truss has
to redeliver because job site is not prepared for
elivery or buyer is not prepared for delivery of trusses. Buyer Is
24" O.C. THRIJ
CORNER JACKS `
ONLY 24"
responsible to Chambers Truss for towing costs clui
: 6. Price as shown in paragraph 7 below is subj
to site conditions.
t to change if any changes are made in this layout. A $50 per hour
CORNER DETAIL
fee for revisions may be charged by Chambers Tru
s.
7. This is a PURCHASE ORDER to Chambers
Fruss of the sum agreed to, or if no agreement a reasonable price. I
Invoice will be made on delivery and paid within terms
of net on delivery. Invoice may be made at scheduled date of
OVERHANGS NOT SHOWN FOR CLARITY
delivery if buyer cannot accept delivery of fabri
ailed trusses. The undersigned agrees to pay Chambers Truss;
UNSUPPORTED JACK CONNECTION DETAIL
MT816 strap (or equal) over Top Chord and under Bottom Chord with 110d x 1.5"
nails: 7 nails in Carrier Jack: 7 in Hip Carrier
Double straps for 5 Jacks
HIP CARRIER
CARRIED JACK f
5'
IUM CANTILEVER
Trusses beginning "JU" and
other unsupported truss should
be installed tigis way.
PLUMB CUT END 12
2X4 TOP CHORD
WALL HEIGHT 9'-4" 4 r-
END DETAIL: TYPICAL
reasonable a#tomeys fee for collections In event of payment not timely made. 1-1/2 /o per month service charge will be
added for all sums not paid within terms.
8, Signature or initials anywhere on this sheet ocristitutes agreement to all terms herein.
9. In consideration of Chambers Truss extendin credit for this material the undersigned unconditionally guarantees
payment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
'undersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the
recipient.
i 10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
herein, the parties agree that the sole venue for an such action will be Saint Lucie County, Florida.
11. Design responsibilities are per mNational Standard And Recommended Guidelines On Responsibilities For
Construction Using Metal Plate Connected Wood Tr isses ANSI/TPI/WTCA 4 - 2002m
12, Warranty is per Chambers Truss Warranty aft iched.
E'
DATED
t
,SIGNED
FOR TITLE
A spreader bar may be requir d per "BCSI" to prevent injury 8L damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do o can result in roof collapse. i
i
Temporary and permanent bracingare q ired and can save life and property '
and is the responsibility of the truss erector. I
Study the contents of the inforination packet included on delivery before '
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
I
Do not set bunks or stack o plywood, roofing material or any other
concentrated loads or trusses, this can cause collapse.
I
DO NOT INS T LL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBE S TRUSS INC
i
3105
can er venue
Fort Pier , Florida 34982.6423
00-551.5932
Fort Pierce 77 465.2012 Fax 772.465.8711
Vero Beach 772.5 -2012 Stuart 772-286.3302
Web Site: HAMBERSTRUSS.COM
Email: MAIL CHAMBERSTRUSS.COM ?
LOADING/DESIGN CRITERIA REDUCIBLE i
DESIGN CRITERIA
PER CODE SUCH AS SBC 1604.5.1
County ST
LUCIE i
Building Department ST
LUCIE CO.
Wind Design Criteria AS
E 7-16
Wind Design Method MV
FRS(Directional)/C-C hybrid Wind ASCE 7-16
Roofing Material Shi
igle or Shake
Loading in PSF Roof
R.D.L. Floor
Top Chord Live 20
0
Top Chord Dead 10
4.2 0
Bottom Chord Live *10-N
on Conccurent 0
Bottom Chord Dead 10
3 0
Total Load 50
7.2 0
Duration Factor 1.25
0
Wind Speed 160rr
ph
Top Chord C.B. Shea
ing by builder
Bottom Chord C.B. Shea
hing by builder
Highest Mean Height 15,
Building Type Encic
sed
Building Category II: N
n Restrictive
Exposure Category C>O
en Terrain with scattered obstructions
Miles from Ocean 5
Conforms to Florida Building Code 202
i
R.D.L.=Restraining Dead Load C.B.=
ontinuous Bracing i
Verify DESIGN CRITERIA shown ab
ve with the
building department and your engin
r.
Design Criteria is the responsibility cf
the
Building Designer and/or Engineer o
Record
Chambers Truss Inc. DrawingName:
77419
SCALE: 1 /4" _ 1 r_Oir
151 total trusses, 45 unique designs
Designer: RAC Review
d by:
Date: 04/13/21 Revised
0�5f 17/21
FOR
LORI ANN WINN
DESCRIPTION:
i
WINN
Page 1 of 1 CUSTOMER INITIALS
EACH PAGE
77419