Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 5701 Shannon Drive 1650 LHG - E Builder Name: WADE JOURNEY Street: 5701 SHANNON DRIVE Permit Office: ST LUCIE City, State, Zip: FL, Permit Number: Owner: WADE JOURNEY Jurisdiction: 661000 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type01456.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1164.00 ft2 b. Frame - Wood, Adjacent R=13.0 292.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1650.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1650.00 ft2 6. Conditioned floor area above grade (ft2) 1650 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(126.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 330 a. U-Factor: Dbl, U=0.35 126.00 ft2 SHGC: SHGC=0.29 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 22.2 SEER:14.50 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.290 a. Electric Heat Pump 22.2 HSPF:8.20 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1650.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1650.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.076 Total Proposed Modified Loads: 48.11 PASS Total Baseline Loads: 49.63 1 hereby certify that the plans and specifications covered by Review of the plans and -1JE S7,91cp this calculation are in compliance with the Florida Energy specifications covered by this �� �y Code. calculation indicates compliance Florida Energy Code. yki �iq �'%' '_ ' {O aG'� with the ««,'�; °°.•,��„ PREPARED BY: u-� DATE: 2/1/2021 Before construction is completed this building will be inspected for compliance with Section 553.908 * n - I hereby certify that this build' as designed, is in compliance the Florida Energy de. Florida Statutes. COIF with WE'T�� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 2/1/2021 2:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: 5701 Shannon Drive 1650 LH Bedrooms: 4 User Conditioned Area: 1650 WADE JOURNEY Total Stories: 1 1 Worst Case: No WADE JOURNEY Rotate Angle: 315 ST LUCIE Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 5701 SHANNON DRIV County: St. Lucie City, State, Zip: FL, CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_AIRPORT 45 90 70 75 369 69 Medium BLOCKS Number Name Area Volume 1 Block1 1650 13200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1650 13200 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 145.5 ft 0 1650 ft2 ---- 0.29 0 0.71 ROOF V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1739 ft2 274 ft2 Dark N 0.4 N 0.4 No 0 18.43 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1650 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1650 ft2 0.1 Wood 2/1/2021 2:50 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>N Exterior Concrete Block - Int Insul Main 4.1 52 6 8 0 420.0 ft2 0 0 0.4 0 2 SE=>E Exterior Concrete Block - Int Insul Main 4.1 18 0 8 0 144.0 ft2 0 0 0.4 0 3 SW=>S Exterior Concrete Block - Int Insul Main 4.1 36 " 6 8 0 292.0 ft2 0 0 0.4 0 4 NW=>W Exterior Concrete Block - Int Insul Main 4.1 38 6 8 0 308.0 ft2 0 0 0.4 0 _ 5 =>W Garage Frame - Wood Main 13 36 6 8 0 292.0 ft2 0 0.25 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>E Insulated Main None .4 3 6 8 20 ft2 2 NW=>W Wood Main None .46 2 8 6 8 17.8 W 3 =>W Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 315 degrees). Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 ne=>N 1 Vinyl Low-E Double Yes 0.35 0.29 N 30.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 2 se=>E 2 Vinyl Low-E Double Yes 0.35 0.29 N 30.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 3 sw=>S 3 Vinyl Low-E Double Yes 0.35 0.29 N 30.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 nw=>W 4 Vinyl Low-E Double Yes 0.35 0.29 N 6.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 NW=>W 4 Vinyl Low-E Double Yes 0.35 0.29 N 30.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 403 ft2 403 ft2 45.5 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1540 84.49 158.62 .1372 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.2 22.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 14.522.2 kBtu/hr 666 cfm 0.75 1 sys#1 2/1/2021 2:50 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location . EF Cap Use SetPnt Conservation 1 Electric None Main 0.92 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model# Area Volume FEF None None ft2 DUCTS — Supply -- V --- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 330 ft2 Main 82.5 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[ ] Jan [[ ]] Feb [ Mar Apr May [X] Jun [X] Jul Au Se Oct Nov Dec HeatinJan [X] Feb Mar Apr f May [ ] Jun [ ] Jul Auf rj SeP Oct Nov H HDec Ventin [ ] Jan [ ] Feb X Mar [X] A r [ Ma [ ] Jun [ ] Jul Aug [ Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space 116— Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 2/1/2021 2:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4