HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 5701 Shannon Drive 1650 LHG - E
Builder Name: WADE JOURNEY
Street: 5701 SHANNON DRIVE
Permit Office: ST LUCIE
City, State, Zip: FL,
Permit Number:
Owner: WADE JOURNEY
Jurisdiction: 661000
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type01456.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1164.00 ft2
b. Frame - Wood, Adjacent
R=13.0 292.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1650.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1650.00 ft2
6. Conditioned floor area above grade (ft2) 1650
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(126.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 330
a. U-Factor: Dbl, U=0.35 126.00 ft2
SHGC: SHGC=0.29
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
22.2 SEER:14.50
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.290
a. Electric Heat Pump
22.2 HSPF:8.20
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1650.0 sqft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 1650.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.076 Total Proposed Modified Loads: 48.11
PASS
Total Baseline Loads: 49.63
1 hereby certify that the plans and specifications covered by
Review of the plans and
-1JE S7,91cp
this calculation are in compliance with the Florida Energy
specifications covered by this
��
�y
Code.
calculation indicates compliance
Florida Energy Code.
yki �iq �'%' '_ '
{O
aG'�
with the
««,'�; °°.•,��„
PREPARED BY: u-�
DATE: 2/1/2021
Before construction is completed
this building will be inspected for
compliance with Section 553.908
* n
-
I hereby certify that this build' as designed, is in compliance
the Florida Energy de.
Florida Statutes.
COIF
with
WE'T��
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE COPY
2/1/2021 2:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
5701 Shannon Drive 1650 LH Bedrooms: 4
User Conditioned Area: 1650
WADE JOURNEY Total Stories: 1
1 Worst Case: No
WADE JOURNEY Rotate Angle: 315
ST LUCIE Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 5701 SHANNON DRIV
County: St. Lucie
City, State, Zip:
FL,
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_AIRPORT 45 90
70 75 369 69 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1650 13200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1650 13200 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 145.5 ft 0
1650 ft2 ---- 0.29 0 0.71
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1739 ft2 274 ft2 Dark
N 0.4 N 0.4 No 0 18.43
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1650 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1650 ft2 0.1 Wood
2/1/2021 2:50 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar Below
1
NE=>N Exterior Concrete Block - Int Insul Main
4.1 52 6 8
0 420.0 ft2
0
0 0.4
0
2
SE=>E Exterior Concrete Block - Int Insul Main
4.1 18 0 8
0 144.0 ft2
0
0 0.4
0
3
SW=>S Exterior Concrete Block - Int Insul Main
4.1 36 " 6 8
0 292.0 ft2
0
0 0.4
0
4
NW=>W Exterior Concrete Block - Int Insul Main
4.1 38 6 8
0 308.0 ft2
0
0 0.4
0
_ 5
=>W Garage Frame - Wood Main
13 36 6 8
0 292.0 ft2
0
0.25 0.4
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>E Insulated Main
None
.4 3
6 8
20 ft2
2 NW=>W Wood Main
None
.46 2
8
6 8
17.8 W
3 =>W Wood Main
None
.46 2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 315 degrees).
Wall
Overhang
V
# Omt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation Int Shade
Screening
1 ne=>N 1 Vinyl Low-E Double Yes
0.35 0.29 N
30.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
2 se=>E 2 Vinyl Low-E Double Yes
0.35 0.29 N
30.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
3 sw=>S 3 Vinyl Low-E Double Yes
0.35 0.29 N
30.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
4 nw=>W 4 Vinyl Low-E Double Yes
0.35 0.29 N
6.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
5 NW=>W 4 Vinyl Low-E Double Yes
0.35 0.29 N
30.0 ft2 1 ft 0 in
1 ft 0 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 403 ft2 403 ft2
45.5 ft
8 ft
1
INFILTRATION
#
Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1540 84.49 158.62 .1372
7
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.2
22.2 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit/ Split
Sing[ SEER: 14.522.2 kBtu/hr 666 cfm
0.75 1
sys#1
2/1/2021 2:50 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
. EF Cap
Use
SetPnt
Conservation
1 Electric
None
Main
0.92 50 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model# Area
Volume
FEF
None None
ft2
DUCTS
— Supply --
V
--- Return --
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 330 ft2
Main
82.5 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[ ] Jan [[ ]] Feb
[
Mar
Apr
May [X] Jun [X] Jul
Au
Se
Oct
Nov
Dec
HeatinJan [X] Feb
Mar
Apr f
May [ ] Jun [ ] Jul
Auf
rj
SeP
Oct
Nov
H
HDec
Ventin [ ] Jan [ ] Feb
X Mar
[X] A r [
Ma [ ] Jun [ ] Jul
Aug
[ Se
[X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
116— Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
2/1/2021 2:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4