Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Revision 1-14-2022
i OFFICE USE ONLY: (Q DATE FILED: PERMIT # in p., 0 / `�5 REVISION FEE: RECEIPT # 10 s n PLANNING.& DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 JAN 1 4 2022 (772) 462-1553 St. Lu - Per tiy sm mittin APPLICATION FOR BUILDING PERMIT REVISIONS J PROJECT INFORMATION 41V sr c0/0 u ' .0? LOCATION/SITE penv. 0U� ADDRESS: DETAILED DESCRIPTION OF PROJECT REVISIONS: Ae-C-Drrc f woC CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: PHONE (DAYTIME): OWNER/BUILDER INFORMATION: NAME: 12 ADDRESS: CITY: Ja PHONE (DA ARCHITECT/ENGINEER INFORMATION: NAME MHARA � I'r C ADDRE S: CITY: STATE: _ PHONE (DAYTIME): b SLCCC: 9123109 Revised 06130/17 ST. LUCIE CO CERT. #: FAX: ZIP: ZIP: FORM R405-2020 FLORIDA ENERGY EFFICIENCY, CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GARCIA RESIDENCE Builder Name: ✓9� Street: LINWOOD AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: ,o�G Owner: MANUEL AND MARIA GARCIA Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2) 0� O 1. New construction or existing New (From Plans) 10. Wall Typ02689.5 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block- Int Insul, Exterior R=4.1 2489.50 ft2 b. Frame - Wood, Adjacent R=11.0 200.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Types (2675.0 sgft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2675.00 ft2 6. Conditioned floor area above grade (ft2) 2675 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(406.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret Attic, AH: LAUNDRY R ft2 RM 6 150 a. U-Factor: Sgl, U=0.29 406.00 ft2 SHGC: SHGC=0.22 b. U-Factor. N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 40.0 SEER:15.50 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 5.224 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.220 a. Electric Strip Heat 27.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2675.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2676.00 ft2 b. Conservation features b. N/A R= ftz None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.152 Total Proposed Modified Loads: 82.66 PASS Total Baseline Loads: 86.57 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this tiD Code. calculation indicates compliancefii,��''J with the Florida Energy Code. PREPARED Y: DATE: - Before construction is completed this building will be inspected for _i Q compliance with Section 553.908 • I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. WE'�� c OWNER/AGEN BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). A - Proposed On of 0.080 exceeds the performance method default limit of 0.08 and therqfo� dpes gel r j9 d ct testing. R405 .2.3 ��ir i i� 1/13/2022 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 P:r)PKn Ran-_gngn INPUT SI1MMARY CHECKLIST REPORT PROJECT Title: GARCIA RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type:' User Conditioned Area: 2675 Lot # Owner Name: MANUEL AND MARIA GARCI Total Stories: 1 Block/Subdi%ision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 01 Street: LINWOOD AVENUE Permit Office: ST LUCIE COUNTY Crass Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, New/E)asting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2675 27684.5 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 KITCHEN/DINING 510 5100 Yes 0 1 Yes Yes Yes 2 LIVING RM 523 6015 No 0 1 Yes Yes Yes 3 DEN 168 1680 No 0 1 Yes Yes Yes 4 BEDROOM 4 186 1860 No 0 1 1 Yes Yes Yes 5 CLST 4 22 220 No 0 1 Yes Yes Yes 6 BEDROOM 3 144 1440 No 0 1 1 Yes Yes Yes 7 WIC 3 49 490 No 0 1 Yes Yes Yes 8 BATH 3 63 630 No 0 1 No Yes Yes 9 HALLWAY 68 680 No 0 1 No Yes Yes 10 FOYER 100 1150 No 0 1 Yes Yes Yes 11 STORAGE 30 300 No 0 1 No Yes Yes 12 BATH 2 40 400 No 0 1 No Yes Yes 13 WIC 2 30 300 No 0 1 Yes Yes Yes 14 BEDROOM 2 138 1380 No 0 1 1 Yes Yes Yes 15 LAUNDRY RM 64 640 No 0 1 Yes Yes Yes 16 HALL 18 180 No 0 1 No Yes Yes 17 M BATH 145 1450 No 0 1 Yes Yes Yes 18 M TOILET 30 300 No 0 1 No Yes Yes 19 M W IC 2 42 420 No 0 1 No Yes Yes 20 M WIC 1 48 480 No 0 1 Yes Yes Yes 21 MASTER BEDROO 257 2570 No 0 1 1 Yes Yes Yes 1/13/2022 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 1=nRnn Ran-R_gngn INPUT SLIMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation KITCHEN/DININ 60 ft 510 ft' ___ 1 0 0 2 Slab -On -Grade Edge Insulation LIVING RM 23 ft 523 ft' ___ 1 0 0 3 Slab -On -Grade Edge Insulation DEN 12 ft 168 f? ___ 1 0 0 4 Slab -On -Grade Edge Insulation BEDROOM 4 27 ft 186 ft' ___ 1 0 0 5 Slab -On -Grade Edge Insulation CLST 4 2 ft 22 ft' __ 1 0 0 6 Slab -On -Grade Edge Insulation BEDROOM 3 24 ft 144 ft' 1 0 0 7 Slab -On -Grade Edge Insulation WIC 3 6 ft 49 ft' ___ 1 0 0 8 Slab -On -Grade Edge Insulation BATH 3 1 ft 63 ft' ___ 1 0 0 9 Slab -On -Grade Edge Insulation HALLWAY 1 ft 68 ft' ___ 1 0 0 10SIab-On-Grade Edge Insulation FOYER loft 100 ftF ___ 1 0 0 11SIab-On-Grade Edge Insulation STORAGE 1 ft 30 ft' ___ 1 0 0 12SIab-On-Grade Edge Insulation BATH 2 1 ft 40 ft' ___ 1 0 0 13SIab-On-Grade Edge Insulation WIC 2 5 ft 30 ft' ___ 1 0 0 14SIab-On-Grade Edge Insulation BEDROOM 2 11 ft 138 ft' ___ 1 6 0 15SIab-On-Grade Edge Insulation LAUNDRY RM 4 ft 64 ft' ___ 1 0 0 16SIab-On-Grade Edge Insulation HALL 1 ft 18 ft' ___ 1 0 0 17SIab-On-Grade Edge Insulation M BATH 9 ft 145 ft' ___ 1 .0 0 18SIab-On-Grade Edge Insulation M TOILET 1 ft 30 ft' ___ 1 0 0 19SIab-On-Grade Edge Insulation M W IC 2 1 ft 42 ft' ___ 1 0 0 20SIab-On-Grade Edge Insulation M WIC 1 8 ft 48 ft' ___ 1 0 0 21SIab-On-Grade Edge Insulation MASTER BEDRO 43 ft 257 f? ___ 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 2991 ft' 0 ft' Light N 0.3 No 0.9 No 20 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2675 ftz N N 1 /13/2022 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPU I SUMMAKY UHLILMLlS I KLI'UK I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) KITCHEN/DININ 0 Blown 510ft2 0.1 Wood 2 Under Attic (Unvented) LIVING RM 0 Blown 523 ftz 0.1 Wood 3 Under Attic (Unvented) DEN 0 Blown 168 ft2 0.1 Wood 4 Under Attic (Unvented) BEDROOM 4 0 Blown 186 ftz 0.1 Wood 5 Under Attic (Unvented) CLST 4 0 Blown 22 ftz 0.1 Wood 6 Under Attic (Unvented) BEDROOM 3 0 Blown 144 ftz 0.1 Wood 7 Under Attic (Unvented) WIC 3 0 Blown 49 ftz 0.1 Wood 8 Under Attic (Unvented) BATH 3 0 Blown 63 ftz 0.1 Wood 9 Under Attic (Unvented) HALLWAY 0 Blown 68 ftz 0.1 Wood 10 Under Attic (Unvented) FOYER 0 Blown 100 ft2 0.1 Wood 11 Under Attic (Unvented) STORAGE 0 Blown 30 ftz 0.1 Wood 12 Under Attic (Unvented) BATH 2 0 Blown 40 ftz 0.1 Wood 13 Under Attic (Unvented) WIC 2 0 Blown 30 ftz 0.1 Wood 14 Under Attic (Unvented) BEDROOM 2 0 Blown 138 ftz 0.1 Wood 15 Under Attic (Unvented) LAUNDRY RM 0 Blown 64 ftz 0.1 Wood 16 Under Attic (Unvented) HALL 0 Blown 18 ftz 0.1 Wood 17 Under Attic (Unvented) M BATH 0 Blown 145 ftz 0.1 Wood 18 Under Attic (Unvented) M TOILET 0 Blown 30 ftz 0.1 Wood 19 Under Attic (Unvented) M W IC 2 0 Blown 42 ft2 0.1 Wood 20 Under Attic (Unvented) M W IC 1 0 Blown 48 ftz 0.1 Wood 21 Under Attic (Unvented) MASTER BEDRO 0 Blown 257 ftz 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it r)rnt Space In Wall lype _ 1 N Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 15 0 10 0 150.0 ftz 0 0 0.3 0 _ 2 E Exterior Concrete Block- Int InsuKITCHEN/DI 4.1 11 0 10 0 110.0 ftz 0 0 0.3 0 _ 3 W Exterior Concrete Block - Int InsuKITCHEN/DI 4.1 34 0 10 0 340.0 ftz 0 0 0.3 0 _ 4 N Exterior Concrete Block - Int Insul LIVING RM 4.1 23 0 11 6 264.5 ftz 0 0 0.3 0 _ 5 W Exterior Concrete Block - Int Insul DEN 4.1 12 0 10 0 120.0 ftz 0 0 0.3 0 _ 6 S Exterior Concrete Block - Int InsuBEDROOM 4 4.1 11 0 10 0 110.0 ftz 0 0 0.3 0 _ 7 W Exterior Concrete Block - Int InsuBEDROOM 4 4.1 16 0 10 0 160.0 ftz 0 0 0.3 0 _ 8 S Exterior Concrete Block- Int Insul CLST 4 4.1 2 0 10 0 20.0 ftz 0 0 0.3 0 _ 9 E Exterior Concrete Block - Int InsuBEDROOM'3" 4.1 12 0 10 0 120.0 ftz 0 0 0.3 0 _ 10 S Exterior Concrete Block - Int InsuBEDROOM 3 4.1 12 0 10 0 120.0 ftz 0 0 0.3 0 _ 11 E Exterior Concrete Block- Int Insul WIC 3 4.1 6 0 10 0 60.0 ftz 0 0 0.3 0 _ 12 S Exterior Concrete Block- Int Insul FOYER 4.1 10 0 11 6 115.0 ftz 0 0 0.3 0 _ 13 E Exterior Concrete Block- Int Insul WIC 2 4.1 5 0 10 0 50.0 ftz 0 0 0.3 0 _ 14 E Exterior Concrete Block- Int InsuBEDROOM 2 4.1 11 0 10 0 110.0 ftz 0 0 0.3 0 _ 15 S Garage Frame - Wood BEDROOM 2 11 12 0 10 0 120.0 ftz 0 0.1 0.3 0 _ 16 W Exterior Concrete Block - Int InsuLAUNDRY R 4.1 4 0 10 0 40.0 ftz 0 0 0.3 0 _ 17 S Garage Frame - Wood LAUNDRY R 11 8 0 10 0 80.0 ftz 0 0.1 0.3 0 _ 18 E Exterior Concrete Block - Int Insul M BATH 4.1 9 0 10 0 90.0 ftz 0 0 0.3 0 19 E Exterior Concrete Block- Int Insul M W IC 1 4.1 8 0 10 0 80.0 ftz 0 0 0.3 0 1/13/2022 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 20 N Exterior Concrete Block - Int InsuMASTER BE 4.1 17 0 10 0 170.0 ft2 0 0 0.3 0 21 E Exterior Concrete Block - Int InsuMASTER BE 4.1 15 0 10 0 150.0 ft2 0 0 0.3 0 22 W Exterior Concrete Block - Int InsuMASTER BE 4.1 11 0 10 0 11 0.0ft2 0 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated LAUNDRY R None .23 2 8 7 8 20A ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.29 0.22 Y 30.0 ft2 1 ft 6 in 1 ft 4 in None None 2 W 3 Vinyl Low-E Single Yes 0.29 0.22 Y 40.0 ft2 1 ft 6 in 1 ft 4 in None None 3 N 4 Vinyl Low-E Single Yes 0.29 0.22 Y 96.0 ft2 13 ft 6 in 1 ft 4 in None None 4 W 5 Vinyl Low-E Single Yes 0.29 0.22 Y 20.0 ft2 1 ft 6 in 1 ft 4 in None None 5 S 6 Vinyl Low-E Single Yes 0.29 0.22 Y 30.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 6 W 7 Vinyl Low-E Single Yes 0.29 0.22 Y 20.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 7 S 10 Vinyl Low-E Single Yes 0.29 0.22 Y 30.0 ft2 1 ft 6 in 1 ft 4 in None None 8 S 12 Vinyl Low-E Single Yes 0.29 0.22 Y 40.0 ft2 10 ft 6 in 1 ft 4 in None None 9 E 14 Vinyl Low-E Single Yes 0.29 0.22 Y 20.0 ft2 1 ft 6 in 1 ft 4 in None None 10 E 18 Vinyl Low-E Single Yes 0.29 0.22 Y 20.0 ft2 1 ft 6 in 1 ft 4 in None None 11 N 20 Vinyl Low-E Single Yes 0.29 0.22 Y 30.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 12 E 21 Vinyl Low-E Single Yes 0.29 0.22 Y 115.0 ft2 1 ft 6 in 1 ft 4 in None None 13 E 21 Vinyl Low-E Single Yes 0.29 0.22 Y 15.0 ft2 1 ft 6 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 20 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000329 2307.1 126.57 237.63 .1 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Black Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 1 /13/2022 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY 'CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 15.5 40 kBtulhr 1200 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply --- --- Return -- Air CFM 25 CFM25 HVAC # v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Proposed Qn LAUNDRY -- cfm 214.0 cfm 0.08 0.50 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb HeatinJan Feb Mar Mar Apr E Apr May Jun Jul f May Jun 4 Jul [X] AugX] ] Au[ Se ] Sep ] Oct [ ] Nov [ ]Oct [X] Nov [ Dec [X] Dec VentingJan Feb Mar [X] Apr [ May Jun [ Jul E ] Aug [ ] Se [X] Oct [Xj Nov [ j Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 DINING RM Default(8lbslsq.ft. ft2 ft 0.3 WET BAR Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8lbs/sq.ft. ft2 ft 0.3 POWDER RM Default(8 Ibslsq.ft. ft2 ft 0.3 PANTRY Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT RM Default(8 Ibs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibslsq.ft. ft2 ft 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 ft 0.3 M W IC 2 Default(8lbs/sq.ft. ft2 ft 0.3 M WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH 1113/2022 3:27 PM EnergyGauge@) USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN Default(8 Ibs/sq.ft. ft2 ft 0.3 DEN CLST Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 Ibs/s .ft. ft2 ft 0.3 CLST 2 1 /13/2022 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: GARCIA RESIDENCE Builder Name: Street: LINWOOD AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Y U Owner: MANUEL AND MARIA GARCIA Jurisdiction: ST LUCIE COUNTY w x Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface, thermal envelope shall be air tight and IC rated. Plumbing and wiring. Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Diates and walls or ceilings. W. In addition, inspection of log walls shall be in accordance with the provisions of ICC-4UU. 1/13/2022 3:28 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX` = 95 The lower the EnergyPerformance Index, the more efficient the home. LINWOOD AVENUE, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 2489.50 ftz b. Frame - Wood, Adjacent R=11.0 200.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftz 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2675.00 ftz 6. Conditioned floor area (ftz) 2675 b. N/A R= ftz c. N/A R= ftz 7. Windows" Description Area 12. Ducts, location & insulation level R ftz a. U-Factor: Sgl, U=0.29 406.00 ftz a. Sup: Attic, Ret: Attic, AH: LAUNDRY RM 6 150 SHGC: SHGC=0.22 b. U-Factor: N/A ftz SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 40.0 SEER:15.50 SHGC: d. U-Factor: N/A ftz 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 5.224 ft. Area Weighted Average SHGC: 0.220 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ftz a. Electric EF: 0.98 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2675.00 ftz Credits (Performance method) None b. N/A R= ftz c. N/A R= ftz I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. ill312022 3:27 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 -�- wrightsofte, Project Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM For. MAN UELAN D MARIAGARCIA LINWOOD AVENUE, FORT PIERCE, FL Notes: Design Information Job: Date: JAN. 13, 2022 By: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 29703 Btuh Ducts 7310 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 37013 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 2675 2675 Volume (W) 27685 27685 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 148 74 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Airflow factor Static pressure Space thermostat 100 EFF 12.1 kW 41123 Btuh 28 OF 1333 cfm 0.036 cfm/Btuh 1.00 in H2O Sensible Cooling Equipment Load Sizing Structure 20423 Btuh Ducts 10412 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 29293 Btuh Latent Cooling Equipment Load Sizing Structure 4084 Btuh Ducts 2840 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6924 Btuh Equipment Total Load (Sen+Lat) 36218 Btuh Req. total capacity at 0.70 SHR 3.5 ton Cooling Equipment Summary Make Allied Air Enterprises Trade ALLIED Cond 4AC16L42P-50,51 Coil BCE5E42M AHRI ref 204588602 Efficiency 12.5 EER, 15.5 SEER Sensible cooling 28000 Btuh Latent cooling 12000 Btuh Total cooling 40000 Btuh Actual air flow 1333 cfm Air flow factor 0.043 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.82 copyls Calculations approved byACCA to meet all requirements of Manual J %1hFad j -+- wrightsoft® ��+� �••a.+.«..+�++--+<•�•• Right -Suite® Universal 2021 21.0.02 RSU08101 ...Ightsoft WACIGARCIA RESIDENCE- LINWOOD AVE-rup Calc = MJB Front Door faces: S 2022-Jan-13 15:23:17 Page 1 -�- wrightsoft, Right-JO Worksheet Job: Entire House Date: JAN. 13, 2022 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House KITCHENIDINING 2 Exposed wall 244.0 ft 60.0 ft 3 Room height 10.3 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 2675.0 ft' 15.0 x 34.0 ft 510.0 fN Ty Construction number U-value (Bluhlft'--°F) Or HTM (Btuh/fN) Area (ft') or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Grass N/P/S Heat Cool Gross NIP/S Heat Cool 6 13A4ocs 2 glazing, cir low-e 2: glazing, cir low-e 0143 0.290 0.290 n n n' 4.60 8.12 8:112 2.16: 8.96 8.95 585 30 ', 96 426 0 0 -1716 244 7,80 938 269 860 166 30 0 120 0 0 480 244 A 263 269. 0 11 2 glazing„cir lowce. - + 13A4ocs 0.290 0.143 ,n a 8.12' 4.00 5.60 2.19 .. 30 770 0 700 244 2803 _ 168 1532 _ 0 110 0 110 0 440 _ 0 241 2 glazing, cir low-e 2 glazing, clr low-e 0.290 0.290 a a 8.12 8.12 25.49 25.49 15 40 0 0 122 325 382 1020 0 0 0 0 0 0 0 0 --G �-G 2 glazing, cir low-e 13A-flocs' 2,glazing, cir lower 0.290 0.143 0.290 a 's s 8.12 4.00 8.12 14.65 219''' 8.96 15 365 30 0 265 30 122 '1060 244 220 570 ,. 269: 00 0 0 0 0 0 0 0 0 6 0 ------"..G yl 2 glazing, cir lower 2 glazing, cir low-e 13A-4ocs 0.290 0.290 0.143 `s s . w 8.12, ' 8.12 4.00 8.96 5.69 2.19 40 30 770 40 •30 690 326 2,",,- 2763 360 168 1510 0 _ . 0 340 6 0 300 0 .0 1201 0 0 656 2 glazing, cir low-e 2 glazing, cir low-e, 0.290 0.290 w w 8.12 8.12 25.49 14.65 60 20 0 0 487 162 1529 293 40 0 0 0 325 0 1020 0 G "16X19-0md D.408 : - 1.59, . 1.37 2675 2675: 4241' 3660 _510 510 , 809 698 F .. 22A-tph _ .- 1.358 - _ 38.02 0.00 _ 2675 244 ...- 9278 . 0 510 . 60 2281 0 6 c) AED excursion 0 229 Envelope loss/gain 25159 13756 5781 3375 12 a) Infiltration 4544 1217 1095 293 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 5450 800 Subtotal (lines 6 to 13) 29703 20423 6876 4468 Less external load 0 0 0 0 Less transfer D 0 0 0 Redistribution 0 D 3 2 14 Subtotal 29703 20423 6878 4471 15 Duct loads 25% 51% 7310 10412 25% 51% 1693 2279 Total room load 37013 30835 8571 6750 Air required (cfm) 1333 1333 309 292 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -F�F• WWI-10'itsoft- 2022-Jah-1315:23:17 Right-SuiteV Universal 2021 21.0.02 RSU08101 Page 1 ...ightsoft HVACIGARCIA RESIDENCE- LINWOOD AVE,rup Calc = MJ5 Front Door faces: S wrightsoft' Right-J® Worksheet Job: Entire House Date: JAN. 13, 2022 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LIVING RM DEN 2 Exposed wall 23.0 ft 12.0 ft 3 Room height 11.5 ft heat/cool 10.0 ft heat/coal 4 5 Room dimensions Room area 1.0 x 523.0 ft 523.0 ft2 14.0 x 12.0 ft 168.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/tt'--°F) (Stuh/ft2) or perimeter (ft) (Etuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Grass N/P/S Heat Cool 6 13A-4ocs 2glazing, cir iow-e 2 glazing, cir low-e 6.143 0.290 0.290 n n n 4.00 8.12 8.12 2.19 896' 8.96 265 0 96, 166 0 0 M 0 780 369 0 860 0 0 0 0 0 0 0 0 0 6 0 0 2 glazing, cir lower ._ 0.290 n 8.12 5.60 0 0 0 0 0 0 0 0 11 VI/ 13A4ocs 0.143 a 4.00 2.19 0 0 0 _ 0 0 0 0 0 I! r_ 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.290 0.290 0.290 a a a 8.12 8.12 8.12 25.49 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ---G �---G V}l 2 glazing; clr9ow-e 2 glazing, 0.143 0.290 s s 4.12 8.12 2.96 ' 8.96 . 0 0. 0 0 0 D 0 0 0 0 0 0 0 0 0 0 LFF-�-GG . 2 glazing, clr low a 2 glazing, cir low- _ 0.290 0.290 s s 8.12 8.12 8.96 5.60 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.143 w 4.00 2.19 0 0 0 0 120 100 400 219 TA13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 0.290 0.290 w w 8.12 8.12 25.49 14:65 0 (1 0 0 0 0 0 0 20 0 0 0 162 0 510 D C' 16X19-amd 0.408 - 1.59 1.37 523 523 829 716 168 168 266 230 F 22A-tph 1.358 - 313.02 0.00 523 23 875 0 168 12 456 0 6 c) AED excursion -225 185 Envelope loss/gain 3158 1720 1285 1144 12 a) Infiltration 483 129 219 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2500 200 Subtotal (lines 6 to 13) 3641 4349 1594 1403 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 8 6 33 27 14 Subtotal 3648 4355 1538 1430 15 Duct loads 25% 51 o 898 2220 25% 51% 378 729 Total room load 4546 6576 1916 2159 Air required (cfm) 164 284 69 93 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fla- wrighitsoTt^ 2022-Jan-1315:23:17 C.4�A Right -Suite® Universal 2021 21.0.02 RSU08101 Page 2 ...Ightsoft HVAC%GARCIA RESIDENCE- LINWOOD AVE.rup Caic = MJB Front Door faces: 8 -�- wrightsoft, Right-JO Worksheet Job. Entire House Date: JAN. 13, 2022 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 4 CLST 4 2 Exposed wall 27.0 ft 2.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 186.0 ft 2.0 x 11.0 ft 5 Room area 186.0 ft' 22.0 W Ty Construction Llvalue Or HTM Area (ft') Load Area (ft') Load number (Btuhtftk*F) (Btuh/ft') or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 Vll 13A-4ocs 2 glazing, cir low-e 2 glazing, clrlow-e 0.143 0.290 0.290 n n in 4.00 8.12 8.12 2.19 8.96 8.95 0 0 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 l�{CG^ 11 2 glazing, clr low-e, 13A-4ocs 0.290 0.143 n a 8.12 4.00 5.60 2.19 , 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Q 0 G 2 glazing, cir low-e 2 glazing, dr low-e 2 glazing, dr low-e 13A-4ocs 2 glazing, cir low-e . 0.290 0.290 0.290 0.143 0.290 a a a s s 8.12 8.12 8.12 4.00 8.12 25.49 25.49 14.65 2.19 8.96 0 0 0 , 110 0 0 0 0 80 0 0 0 0 326 0 0 0 0 175 0 0 0 0 20 0 0 0 0 20 0 0 0 0 80 0 0 0 0 44 0 2 glazing,, clr low-e 2 glazing; cir low-e 13A-4ocs 0.290 0.290 0.143 s s w 8.12 8.12 4.00 8.96 5.69 2.19 ` 0 30 160 0 30 140 0 244 561 0 168 306 0 0 0 6 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 0.290 0.290 w w 8.12 8.12 25.49 14.65 0 20 0 0 0 162 0 293 0 0 0 0 0 0 0 0 C 16X19-omd 0.408 - 1.59 1.37 _ 186 186 295 254 22 22 35 30 F 22A-tph 1.358 - 38.02 _ 0.00 186 27 1027 0 22 2 76 0 6 c)AED excursion 87 -4 Envelope loss/gain 2608 1284 191 70 12 a) Infiltration 493 132 37 10 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3101 1416 228 80 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 134 51 -228 -80 14 Subtotal 3235 1467 0 0 15 Duct loads 25% 51% 796 748 25% 51% 0 0 -T Total room load 4031 2215 0 0 Air required (cfm) 1 1 145 96 101 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C -Opt- wr9ghtsoft- 2022-Jan-1315:23:17 Awk- -^-� Right-Suite'S Universal 2021 21.0.02 RSUD8101 Page 3 ...ightsoft HVAC%GARCtA RESIDENCE- LINWOOD AVE.rup Calc = MJ8 Front Door faces: 8 -�- wrightsoft• Right-M Worksheet Job: Entire House Date: JAN. 13, 2022 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 WIC 3 2 Exposed wall 24.0 ft 6.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 12.0 x 12.0 ft 144.0 ft' 7.0 x 7.0 ft 49.0 ft' Ty Construction U value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'--°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 Vjt' 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 04143 0.290 0.290 n n n 4.00 8.12 8.12 2.19 8.96 8A6 0 0- 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 1��-�1C, Vh13A4ocs 2 glazing, cir low-e . 0.290 0.143 n. a 8.12 4.00 5.60 2.19 0 120 0 120 A 480 0. 263 0,. 60 0 60 0 240 0 131 2 glazing, cir low-e 2 glazing, cir low-e 0.290 0.290 a a 8.12 8.12 25.49 25.49 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, olr low-e 0.290 a 8.12 14.65 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, clrlow-e D. 143, 0.290 s s 4.06 8.12 ' 2.19 8.96 ' 120 30 90 30 360 244 197 269 0 0 0 0 0 0 0 0 " 2 glazing, cir low-e 2.glazing,cirlow-e 0.290 0.290 s s_ 8.12 8.12 8.96 5.60 0 0 0 0: 0 _ 0 0 0 0 0 0 0 0 _ 0 0 0 13A4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, dr taw-e 2 glazing, cir low-e 0.290 0.290 w w 8.12 8.12 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 - 1.59 1.37. 144 144 228 . _ 197 49 49 78 67. IF 22A-tph 1.358 - 313.02 0.00 144 24 913 „ 0 49 _ 6 228 0 5 c)AED excursion -81 -11 Envelope loss/gain 2225 845 546 187 12 a) Infiltration 438 117 110 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 600 0 Subtotal (lines 6 to 13) 2663 1562 656 216 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 117 47 18 15 14 Subtotal 2780 1609 674 231 15 Duct loads 25% 51% 684 820 25% 51% 166 118 Total room load 3465 2429 839 349 Air required (cfm) 125 105 30 15 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. -O.F wrllghtsofte 2022-Ian-1315:23:17 ^ ^- Right -Suite® Universal 2021 21.0.02 RSU08101 Page 4 ...ightsoft HVACIGARCIA RESIDENCE- LINWOOD AVE.rup Caic = MJ8 Front Door faces: S -f - wrightsoft' Right-M) Worksheet Job: Entire House Date: JAN.13, 2022 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 3 HALLWAY 2 E)posed wall 0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 1.0 x 68.0 ft 68.0 ft' Ty Construction U-value Or HTM Area (ftj Load Area (ft2) Load number (Btuhtft'VF) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1f1! 13A oos 2 glazing, cir low-e 2 glazing, cir low-e 0.19 0.290 0.290 n n n 4.00 8,12 8.12 , 8:96 8.96 8.95 0 0 0 0 0 0 0 0 0 0' 0• 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e _ 13A4ocs 0:290 0.143 n a 8.12 4.00 5.60 2.19 . 0 0 0 0 0 0 .. 0 0 0 0 0 0 0: 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 0.290 0.290 0.290 a a a 8.12 8.12 &12 25.49 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A 4ocs 2 glazing, clr low-e 0.143 0.290 s s 4.00 8.12 2.19 8.96 - 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, clr loW-e 13A-4ocs 0.290 0.290 0.143 s s.- w 8.12 8.12 4.00 8.96 5.60 Z19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, cir low- 0.290 0.290 w w 8.12 8.12 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C' 16X19-0md 0.408 - 1.59 1.37 63 63 100 86 68 68 log 93 F 22A tph 1.358 .- 38.02 _ OAM .. 63 0 0 0 _ 68 0 0 0 6 c) AED excursion -4 -5 Envelope loss/gain 100 82 108 88 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 100 82 108 B8 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 23 19 -108 -88 14 Subtotal 123 101 0 0 15 Duct loads 25% 51% 30 51 25% 51% 0 0 Total room load T7153 152 T77� 0 Air required (cfm) 6 7 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -�- wrlghtsof :- 2022-IanA3 15:23:17 A Right-SuiteO Universal 2021 21.0.02 RSU08101 Page 5 ...ightsoft HVAC\GARCIA RESIDENCE- LINWOOD AVE,rup Calc = MJB Front Door faces: S -F�- wrightsok Right-J® Worksheet Job: Entire House Date: JAN.13, 2022 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER STORAGE 2 Exposed wall 10.0 ft 0 ft 3 Room height 11.5 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 10.0 ft 100.0 fta 6.0 x 5.0 ft 30.0 It, Ty Construction U-value Or HTM Area (ft-) Load Area (fta) Load number (Btuh/ft1VF) (Btuh/fN) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 2 glazing, cirlow-e 2 glazing, cir low-e 0.143 0.290 0.290 n n n 4.00 812 8.12 2.19 8.96 8.95 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e cs 0.290 0.290 n a 8.12 4.12 5.60 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0' 0 2 glazing, cir low-e 2 glazing, 2 glazing, dr low-e 2 glazing, cir low-e 0.290 0.290 0.290 a a a 8.12 8.12 8.12 5.19 25.49 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, clr low-e 0.143 0.290 s s 4.00 8.12 2.19 8.96 115 0 75 0 299 0 164 0 0 0 0 0 0 0 0 0 ���----GGG 2 glazing, clrlow-e 2 glazing, clriow-e 13A-4ocs 0.290 0.290 0.143 s s w 8.12 8.12 4.00 8.96 5.60 2.19 40 0 0 40 0 0 326 0_ 0 360 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 16X19-Omd 0.290 0.290 D.408 w w - 8.12 8.12 1.59 25.49 14.65 1.37 0 0 100 0 0 100 0 0 159 0 0 137 0 0 30 0 0 , 30 0 0 48 0 0 41 C' ; F 22A-tph 1.358 , - 38.02 DAM 100 10 380 0 30 . 0 _ 0 0 6 c) AED excursion -25 -2 Envelope loss/gain 1165 636 48 39 12 a) Infiltration 210 56 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1375 692 48 39 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 4 10 8 14 Subtotal 1379 696 57 47 15 Duct loads 25% 51% 339 355 25% 51% 14 24 Total room load 1719 1051 71 71 Air required (cfm) 62 45 3 3 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wriat tsoft^ 2022-Jan-1315:23:17 ^ - ^ Right -Suite® Universal 2021 21.0.02 RSUD8101 Page 6 ...ightsoft HVAC%GARCIA RESIDENCE- LINWOOD AVE.rup Caic = MJB Front Door faces: 8 -+ wrightsoft° Right-J® Worksheet Job: Entire House Date: JAN. 13, 2022 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@%aOL.COM 1 Room name BATH 2 WIC 2 2 E)q3osed wall 0 ft 5.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 8.0 x 5.0 ft 40.0 ft' 6.0 x 5.0 ft 30.0 ft' Ty Construction U-value Or HTM Area (ft-) Load Area (ftj Load number (Btuhlft''F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vh 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.1436 0.290 0.290 n n 4.00 8.12 8.12 2.16 8.96 8.95 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e 13A flocs 0.290 0.143 n a 8.12 4.00 5.60 2.19 0 0 0 0 0 0 0. 0 0 50 0 50 0 200 0 109 2 glazing, cir low-e 2 glazing, cir low-e 0.290 0.290 a a 8.12 8.12 25.49 25.49 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.290 a 8.12 14.65 0 0 0 0 0 0 0 0 V� 2 glazing, clr low-e 2glazing, 0.290 0:290 s s 4.&12 8.12 8.96 8.96 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 0.290 D.290 s s 8.12 8.12 8.96 5.60 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 13A4ocs 0.143 w 4.00 Z19 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e D.290 0.290 w w_ 8.12 8.12 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 - 1.59 1.37 40 40 63 55 30 30 ,_ 48 41 F 22A-tph 1.358 - 38.02 0.00 40 0 0 0 30 5 190 0 6 c)AED excursion 3 -9 Envelope loss/gain 63 521 438 142 12 a) Infiltration 0 0 91 24 b) Room ventilatlon 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other a 0 Subtotal (lines 6 to 13) 63 52 5291 166 Less extemal load 0 0 0 0 Less transfer 0 0 0 0'i Redistribution 0 0 0 0 14 Subtotal 63 52 529 166i 15 Duct loads 25% 51% 16 27 25% 51% 130 85 Total room load T79 797- 659 251 Air required (cfm) 3 3 24 11 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A wrigFi tsol`t� 2022-Jan-13 15:23:17 Right-Suite9 Universal 2021 21.0.02 RSU08101 Page 7 ightsoft HVACIGARCIA RESIDENCE- LINWOOD AVE.rup Calc = MJ8 Front Door faces: 8 -�- wrightsoft, Right-.10 Worksheet Job: Entire House Date: JAN. 13, 2022 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 LAUNDRYRM 2 Exposed wall 11.0 ft 4.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 138.0 ft 138.0 ft° 8.0 x 8.0 ft 64.0 ft' TY Construction LIvalue Or HTM Area (ft2) Load Area (ft-) Load number (Btuh/fN-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Coal Grass N/P/S Heat Cool Grass N/P/S Heat Cool 6 13A-4ocs 2 glazing, olr low-e 0.143 0.290 n n 4.00 8.12 2.19 8.96 ' 6 0 0 0 D 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.290 ,. n 8.12 8.95 0, 0 0 D 0 0 0 0 11 2 glazing, cir law=e, 13A4ocs 0.290 0.143 n a 8.12 4.00 5.60 2.19 0 110 0 90 0_ 360 0 197 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 13A-4as 2 glazing, cir low-e 0.290 0.290 0.290 0.143 0.290 a a a s s 8.12 8.12 8.12 4.00 8.12 25.49 25.49 14.65 2.19 ' 8.96 0 20 0 0 0 0 0 0 0 0 0 162 0 0 0 0 510 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ��- . 2 glazing, Or low-e 2 glazing, clr low-e 0.290 0.290 s s 8.12 8.112 . 8.96 5.60 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.143 w 4.00 2.19 0 0 0 0 40 40 160 88 Ti13A4ocs 2 glazing, cir tow-e 2 glazing, clr low-e. 0.290 0.290 w w 8.12 8.12 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X1.9-0md 0.408 - 1.59 1.37 138 138 219 189 64 64 101 88 F , 22A-tph 1.358 - 38A2 0.00 _ 139 11 418 0 64 4 152 0 6 c)AED excursion -11 -34 Enwlope loss/gain 1160 885 414 141 12 a) Infiltration 201 54 73 20 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 500 500 Subtotal (lines 6 to 13) 1361 1439 487 660 Less erdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 5 4 10 8 14 Subtotal 1365 1443 496 668 15 Duct loads 25% 51% 336 735 25% 51% 122 341 Total room load 1701 2178 618 1009 Air required (cfm) 61 94 22 44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t wrY-gF�t .c ft- 2022-Jan-13 15:23:17 Right -Suite© Universal 2021 21.0.02 RSU08101 Page 8 ...ightsoft HVACIGARCIA RESIDENCE- LINWOOD AVE. rup Calc = MJ8 Front Door faces: 8 -- wrightsoft• Right-J® Worksheet Job: Entire House Date: JAN• 13, 2022 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name HALL M BATH 2 Exposed wall 0 ft 9.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 3.0 ft 18.0 ft' 1.0 x 145.0 ft 145.0 ft' Ty Construction number U-value (Btuh/ft'-°F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Grass N/P/S Heat Cool Gross NIP/S Heat Cool 6 13Adocs e 2 glazing, clr low- 2 glazing, cir low- 0.290 D:290 0.290 n ' n n 4.00 8.12 8.12 .95 88.96 8.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, cir low- _ 13A-4ocs 0.290 0.143 n a 8.12 4.00 5:60 2.19 . 0 0 0 0 0._ 0 0 0 0 90 0 70 0 280 0 153 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.290 0.290 0.290 a a a 8.12 8.12 8.12 25.49 25.49 14.65 0 0 0 0 0 0 0 0 D 0 0 0 0 20 0 0 0 0 0 162 0 0 510 0 13A-4ocs' 2 glazing, cir low-e 0.143 0.290 s s 4.00 1112 2.19 8.96 , 0 0 0 0 0 0 0 0 .0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing; cir low-e._ 13A4ocs 0.290 0.290 0.143 s s w 8.12 8.12 4.00 8.96 5.60 Z19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 0.290 0.290 w w 8.12 8.12 25.49 14.65 0 0 0 0 0 0_ 0 0 0 0 0 0 0 0 0 0 C 16X19-Dmd 0.408 - 1.59 1.37 18 18 29 25 145 145 _ 230 198 F 22A-tph 1.358 , - 38.02 , D.00 18 0 0 0 145 9 342 0 6 c) AED excursion -1 16 Envelope loss/gain 29 23 1015 877 12 a) Infiltration 0 0 164 44 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 29 23 11791 921 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -29 -23 0 0 14 Subtotal 0 0 1179 921 15 Duct loads 25% 51% 0 0 25% 51% 290 470 Total room load -7 0 0 1469 1391 Air required (cfm) 0 1 531 60 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrlgFstsofta Right -Suited Universal 2021 21.0.02 RSU08101 2022 Jan-13 15:23:17Page 9 ...ightsoft HVACIGARCIA RESIDENCE- LINWOOD AVE. rup Calc = MJ8 Front Door faces: S -�+ wrightsoft` Right-J® Worksheet Job: Entire House Date: JAN.13, 2022 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M TOILET M WIC 2 2 Exposed wall 0 ft 0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 6.0 ft 30.0 W 7.0 x 6.0 ft 42.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Stuh/ft'--'F) (Btu/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Grass N/P/S Heat Cool Gross N/P/S Heat Cool 6 G 13A-flocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.290 0.290 n n n 4.00. 8.12 8.12 2.19 8.96 8.96 0 0 0 0 0 0 0 0 0 0' 0 0' 0 0 0 0 0 0 0 0 0 0 0 0 -- (L __GG 11 2 glazing, cir lower _ 13A-4ocs 0.290 0.143 n a 8.12 4.00 5.60 2.19 .._ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 0.290 0.290 0.290 a a a 8.12 8.12 8.12 25.49 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Vh 2 glazing, cir lower 2 glazing, 0.290 0:29D s s � 8.12 8.12 2.96 8.96 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.290 s 8.12 8.96 0 0 0 0 0 0 0 0 2 glazing, clr low-e _ 13A4ocs 0.290 0.143 . s w 11.12 4.00 5.60 2.19 0 0 0 0 0- 0 _ 0, 0 0- 0 0 0 .0 0 0 0 2 glazing, cir low-e 2 glazing, clr low-e 0.290 0.290 w w 8.12 8.12 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 _ - 1.59 1.37 30 30 48. 41 42 42 67 57 F _ 2M-tph 1.358 38.02 0.00 30 0 0 _ 0 42 0 0 0 6 c)AED excursion -2 -3 Envelope loss/gain 48 39 67 55 12 a) Infiftration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 48 39 67 55 Less eMemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 39 67 55 15 Duct loads 25% 51% 12 20 25% 51% 16 28 Total room load 59 59 83 82 Air required (cfm) 2 3 3 4 Calculations approved by_ ACCA to meet all requirements of Manual J 8th Ed. -F - wrYghtsoft- 2022-Jan-13 15:23:17 Right -Suite® Universal 2021 21.0.02 RSUOB101 Page 10 ...ightsoft HVACIGARCIA RESIDENCE- LINWOOD AVE, rup Calc = MJB Front Door faces: S - wrightsoft' Right-JO Worksheet Job: Entire House Date: JAN. 13, 2022 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M W IC 1 MASTER BEDROOM 2 Exposed wall 8.0 ft 43.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 8.0 ft 48.0 fN 1.0 x 257.0 ft 257.0 ft' Ty Construction U value Or HTM Area (ft') Load Area (ft-) Load number (Btuh/ft'-°F) (Stuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat C001 Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)1 13A-4ocs 2 glazing, dr low- 2 glazing, c1r low-e 0.143' 0,290 0.290 n n n 4.00 8.12 8.12 ' 2.16 8:96 8.96 0 0 0 0 0 0, 6 0 0 0' 0 0 170 0 0 140 0 0 561 0 0 306 0 0 114--_--_GGG 2 glazing;. clr low-e 0.290: n 8.12 5.60 , 0 - 0 0 0, 30 0 244 168 11 13A-4ocs 0.143 a 4.00 2.19 80 80 320 175 ISO 120 480 263 2 glazing, clr low-e 2 glazing, clr low-e 0.290 0.290 a a 8.12 8.12 25.49 25.49 0 0 0 0 0 0 0 0 15 0 0 0 122 0 382 0 2 glazing, cir low-e 0.290 a 8.12 14.65 0 0 0 0 15 0 122 220 13A-4ocs 2 glazing, cir low-e 0.143 0.290 s. s 4:00 8.12 2.19 .8.96 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cit low- 0.290 s 8.12 8.96 0 0 0 0' 0 0 0 0 2 glazing, clr low-e 0.290 s, 8.12 6.60 0 0 0 0 0 0. _ R 0 13A4ocs 0.143 w 4.00 Z19 0 0 0 0 110 110 440 241 2 glazing, cir low-e 2 glazing, clr low-e 0.290 0.29.0 w w 8.12 8.12 25.49 14.65 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X19-Omd 0.408 - 1.59 1.37 48 48 76 66 257 _ 257 _ 407 352 F 22A-tph_ 1.358 - 38.02 _ 0.00 48 8 _ 304 0 257 43 1635 0 6 c)AED excursion -16 -83 Envelope loss/gain 701 224 4011 1848 12 a) Infiltration 146 39 785 210 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 50 300 Subtotal (lines 6 to 13) 847 314 4796 2358 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 847 314 4796 2358 15 Duct loads 25% 51% 208 160 25% 51% 1180 1202 Total room load 1055 473 5976 3561 Air required (cfm) 38 20 215 164 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoTt� 2022-Jan-13 15:23:17 RightSuiteD Universal 2021 21.0.02 RSU08101 Page 11 ...ightsoft HVACIGARCIA RESIDENCE- LINWOOD AVE.rup Calc = MJB Front Door faces: S Duct System Summary Job: wrightsoft y Date: JAN. 13, 2022 Entire House By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone_ 772-466-6799 Fax 772rt66-6796 Email: QUICKCALCS@AOL.COM For. MANUEL AND MARIAGARCIA LINWOOD AVENUE, FORT PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1333 cfm Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1333 cfm 188 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 C 79 3 3 1.000 4.0 Ox 0 VIFx 12.8 115.0 st2 BATH 3 c 152 6 7 1.000 4.0 Ox 0 V[Fx 27.7 115.0 st3 BEDROOM 2 c 2178 61 94 1.000 7.0 Ox 0 V[Fx 14.2 115.0 st2 BEDROOM 3 h 3465 125 105 1.000 7.0 Ox 0 VIFx 27.1 115.0 st3 BEDROOM 4 h 4031 145 96 1.000 7.0 Ox0 VIFx 34.0 115.0 st3 DEN C 2159 69 93 1.000 7.0 Ox 0 V[Fx 30.5 115.0 st3 FOYER h 1719 62 45 1.000 6.0 Ox 0 V[Fx 16.4 115.0 st1 KITCHEN/DINING h 4286 154 146 1.000 8.0 Ox 0 V[Fx 46.6 135.0 st4 KITCHENIDINING-A h 4286 154 146 1.000 8.0 Ox 0 VIFx 47.6 135.0 st4 LAUNDRY RM C 1009 22 44 1.000 6.0 Ox 0 V[Fx 24.1 115.0 st1 LIVINGRM C 3288 82 142 1.000 8.0 Ox0 VIFx 21.3 115.0 st1 LIVING RM-A C 3288 82 142 1.000 8.0 Ox0 VIFx 53.2 135.0 sty M BATH C 1391 53 60 1.000 6.0 Ox 0 VIFx 18.3 115.0 st2 M TOILET c 59 2 3 1.000 4.0 Ox 0 VIFx 42.2 135.0 st5 M WiC 1 h 1055 38 20 1.000 5.0 Ox 0 V[Fx 35.8 135.0 st5 M WIC 2 C 82 3 4 1.000 4.0 Ox 0 VIFx 39.4 135.0 st5 MASTER BEDROOM h 5976 215 154 1.000 8.0 Ox 0 VIFx 35.4 135.0 st5 STORAGE c 71 3 3 1.000 4.0 Ox 0 VIFx 18.2 115.0 SO WIC 2 h 659 24 11 1.000 4.0 Ox 0 VIFx 13.7 115.0 st2 WIC 3 h 839 30 15 1.000 4.0 Ox0 VIFx 26.2 115.0 st3 ,` -f�l- wrightsoft- ,.� r ..�.. Right-Suitettt Universal 2021 21.0.02 RStJ09101 +C+A ...ightsoft HVAGIGARCIA RESIDENCE- LINWOOD AVE.rup Calc = MJ6 Front Door faces: S 2022-Jan43 15:23:23 Page 1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 375 316 1.000 687 10.0 0 x 0 VinlFix st4 Peak AVF 309 292 1.000 566 10.0 0 x 0 VinlFlx st1 st5 Peak AVF 340 323 1.000 624 10.0 0 x 0 VirllFlx st2 st1 Peak AVF 477 526 1.000 670 12.0 0 x 0 VinlFlx st2 Peak AVF 481 491 1.000 626 12.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1333 1333 0 0 0 0 Ox 0 VIFx wrightsoft® 2022,1an-13 15:23:23 �� �•��...,.•�....,�..., Right-Sufte® Universal 2021 21,0.02 RSU08101 Page 2 ...ightsoft WACIGARCIA RESIDENCE- LINWOOD AVE,rup Calc = MJB Front Door faces: S III 18'0" 1' SLDG DR tj Cu 15 120 S-I1/ �,---------------------------------- ---� 4 18'6 i I --- i Arch IT 00 ' O 4' L� jK01 OO 232' i O � I t a In M 16' 3„ 4,6„ W ADO 5 I � I i� N L--------------- --"'— -------- ------ -- i! 36 3" 10 DR ## SIZE i W x H ROUGH OP QUANTITY REMARKS D1 D1 2- 3 0 X7 8 X1 3/4 6,0'x18' 6'3"X7'11" 6'2" xc0" 1 1 EXTERI❑R TRANSOM DR w/TRANS❑M D2 2'8"X7'8"X1 3/8" 34 "x93" 9 INTERIOR DR 6 PANEL D3 2'6"X7'8"Xl 3/8" 32'x93' 7 INTERI❑R DR 6 PANEL. D4 2'8"X7'8"X1 3/8" 34'x93' 1. GA. DR,-1 HR FIRERATED D5 3'0"X7'8"X1 3/4" 3'2' 7'11' 1 XL D6 12'0°X8,0„ 12'0"Xg'0" 1 12' SLIDING DR is 3 Pantry' „ Ref 20'2" 5,8„ 6„ _— I - Stor ge Vld.l. Arch _ Arch__ "d 1 m _ _ 6 I j l II'A�J DEN N 10' r 0 FLAT CLC�-�-- 12 , 2„� Ri i ! I �4� lo ui �'�4' rid i I o f i IT 3 13 6 2 —q 4 —,— - w - ! 11,0„ -- -- 8EDRO M iG � 9,0„ ti j 9 10'0" FLAI CLG9A( �,2 3 SIZE WxH ROUGH OP ROUGH OP QUANTITY REMARKS MANUF.. MODEL POURED SILLS [PRECAST SILLS WI 52x 62 52�4x63 5 MIN 5 SF ❑PENING W2 72x 62 1_ I2�'i.x63 q W3 36 x 62 36�4x63 4 W1 52x 62 52:4x63 1 BATH. WIN. OBSCURE --- IN / ,�' -- 110'10`�O EEC EIRE ���� t���Ne�tt� �V(tq �� E®�OC}M �� FRON ENTRY �� EGRESS WIND❑WS IN SLEEPING ROOM 1- MUST HAVE A MINIMUM CLEAR ❑PENING 10'0' FLAT CLG 1� HEIGHT OF 24" & A MIN NET CLEAR 15'2,; �-`-,'� WIDTH OF 20", NET CLEAR OPENING BEDROOM _ 30 AREA SHALL A MIN ❑F . 5 SsQ. ET, 10'0" FLAT G ON GROUND FLOOR 5.7 SQ, FT, ABOVE 13' O" ATTIC ,G i GROUND LEVEL MAX SILL HEIGHT 44' ..� -ACCESS ABOVE FFE R'--�i n,�„