Loading...
HomeMy WebLinkAboutApproved E2.5—43 L2-45 i L2-35 I—millm i IG A IG i I! it 'I I� ------------------------------o- 'I Ln I� CV 0 N O z N H U Q L� C7 z J 0 0 I— w z I— D w 0 0 I I 0 1 N U z N w I— Q U 0 Cn N Q cD z w w z CD z w J Q z 0 Q U GPI E I I T E COMF'RE55OR5 20 (r —i—] 0 1 3 51 r------------------ I -------------------- -- -- -- L— —!I — — — — — — — — — — — — — — — — — — — — — — ! O O O O O O O ----------------- --------------------- ---------------------- ------ 0 COVERED AREA , 19 i i � O 2.1------------------------------------------------� O I I 2------------------------------------------------L---------------------- ----------------------�- 0 I I l o I I I I � LO DING I O I I I I I I I I I I 1--------------------------------------------- ---------------------- ----------------------r----- w ui w w z z i J Q Q I I I I I I I ! ! ! ! ! ! ! ! ! ! H J K L M A 1 e ELECTRICAL ROOM u I TENANCE 22 i T SHOP SEE E2.7 21 FOR DETAILS . I I — — A 5 C i 11 I 1 li I I I I _ _O_ � -- �, ----- \ I LUNDERGROUND SECONDARY SERVICE 26PO KVA 0 I E THAN 5F. Ca Cllj Cu Tank Chiller ALL OWNER SUPPLIED EQUIPMENT IS TO BE COMPLETELY WIRED AND DEMONSTRATED TO BE OPERATIONAL. CONNECT IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTION'S AND PROVIDE OVERCURRENT PROTECTION IN ACCORDANCE W/EQUIPMENT NAMEPLATE DATA. UTILITY CO. PADMOUNT TRANSFORMER C 0 1 cn N N w w w w z z i J U U I— I— Q Q i ! I ---------------!---------------- E 18 I 40 YARD COMPACTOR i CONTAINER ' ------ ------ ---------- ------ ---------- ! I ! I I ! ------ -------------- L---------------------- I I ------------------L----------------------------------------------- I I I ----------------� I ------ ----- ! I ! I I ! ---------------------- I I I I -- ---- ---- ! ! I LOAfDING raciia/y 3901 StLude131M. Ft Fierce FL 34946 Key F-'Ian: Issues:----- No.: Date: Description: A. 08/30/21 OWNER 155 U E B. 09/21/21 OWNER REV151ON5 C. 11/01/21 OWNER REV151ON5 D. 11/04/21 WALL TYPES UPDATED E. 11/15/21 FOUNDATION PERMIT Architect: DONADIO & Associates, Architects P.A. 2001 9th Avenue, Suite 308 Vero Beach, FL 32960 Te1.772.794.2929 Fax.772.562.8600 License No. AA0002238 p www.donadio-arch.com Consultant: KEYED ED X) ALL KEYED NOTES MAY NOT APPLY TO CURRENT DRAWING O CONNECT HAND DRYER. 120V, 12A MAX O INSTALL ELECTRICAL CONNECTIONS AND MOUNT COLUMN MOUNTED FAN AT 14' A.F.F. O FUTURE BIG ASS FAN (BAF). PROVIDE EMPTY CONDUIT TO FUTURE BIG ASS FAN. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED OVERHEAD DOORS IN ACCORDANCE WITH APPROVED SHOP DRAWINGS INCLUDING CONTROLS AND SAFETY INTERLOCKS. O PROVIDE COMPLETE CONNECTIONS REQUIRED FOR PREFAB OFFICE IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. O CORD DROP OVER WORK STATION. VERIFY EXACT LOCATION WITH OWNER/ARCHITECT. O CONNECT BOOTH LTS AND RECEPS. O CONNECT BRIDGE CRANE 200A BUSWAY IN ACCORDANCE WITH SUPPLIER APPROVED SHOP DRAWINGS. THERE IS A 480V CONNECTION (28 FLA MAX) AND A 120V CONTROL CONNECTION. PROVIDE COMPLETE WIRING CONNECTIONS INCLUDING CONTROLS AND SAFETY INTERLOCKS. O PROVIDE COMPLETE CONNECTION FOR HOISTS IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. 10 CONNECT BOOM IN ACCORDANCE WITH APPROVED SHOP DRAWINGS. 11 SUGGESTED LOCATION FOR CONTRACTOR SUPPLIED FUSED SAFETY SWITCHES FOR RESIN TANK EQUIPMENT. SEE E—OB NOTE THAT CLASS 1, DIVISION II AREA EXTENDS 3'-0" BEYOND RESIN TANK. MOUNT SWITCHES OUTSIDE OF CLASSIFIED ZONE. PROVIDE CONDUIT SEAL —OFFS ON LOAD SIDE CONDUIT RUNS. COORDINATE ALL WIRING WITH RESIN TANK SUPPLIER/INSTALLER. ELECT RI CAL - PARTIAL FIRST FLOOR PLAN N SCALE 1 /8" = 1'-0" �® u =mow FA . . . . . . N.T.S. 0a CARDtnAL EI cunEERinc; R550CIRTES IflC. 575 NW MERCANTILE PLACE SUITE 206 PORT ST. LUCIE FL 34986 T.561.746.6343 F.561.746.3602 info@CEAengineers.com PE# 78477 CA LIC. 31555 \\L ItA Joseph L Jose Digitally Larnmned rs Joseph L Lammers Date:2021.11.17��\ Gj �j `�� S Lamm rs 17:04:59-05'00� Q �' No, 78477 `�_ STATE ❑F c�c OR1"�P Drawing Title: ELECTKICAL - f AKTIAL FIF,5T FL00K FLAN Drn: Dwg. File: NL Chd: XREF File: DJL/JLL Project No.: Plot File: 2021-26 Sheet No.: Cert. No.: 12,456 Date Signed: E 2' Copyright ©2021, Ponadio & Associates, Architects, P.A.