Loading...
HomeMy WebLinkAboutApproved P0.AP0.APURSUIT BOATSNew ManufacturingFacility3901 St Lucie Blvd.Ft Pierce FL 34946Dwg. File:XREF File:Plot File:.Copyright C 2021, Donadio & Associates, Architects, P.A.Cert. No.:Date Signed:17,285Sheet No.:Project No.:Chd:MJB/BCSAR/MG2021-26Drn:.Architect:Drawing Title:D O N A D I OVero Beach, FL 32960License No. AA00022382001 9th Avenue, Suite 308& Associates, Architects P.A.Fax.772.562.8600Tel.772.794.2929Consultant:Key Plan:No.:Issues:Description:Date:Project:www.donadio-arch.com575 NW MERCANTILE PLACESUITE 206PORT ST. LUCIEFL 34986T.561.746.6343 F.561.746.3602info@CEAengineers.comPE# 78477 CA LIC. 31555A.08/30/21OWNER ISSUEB.C.09/21/21OWNER REVISIONSD.11/01/21OWNER REVISIONS11/04/21WALL TYPES UPDATEE.11/15/21FOUNDATION PERMITPLUMBING GENERAL NOTES,SYMBOLS, CODES & LEGENDSLEGEND AND ABBREVIATIONS:VENTTRAP PRIMERHOT WATERCOLD WATERCOLDHOTDIAMETERSINKWATER CLOSETLAVATORYTYPICAL FLOOR DRAINNOT TO SCALEBREAKER (HB W/ VB)3/4" HOSE BIBB WITH VACUUM VTPNTSCHECK VALVEBALL VALVE GATE VALVE PIPING UP WALL CLEAN OUT PIPING DOWN SANITARY VENT PIPING SANITARY WASTE PIPING CONDENSATE DRAIN PIPING DOMESTIC COLD WATER PIPING DOM. HOT WATER PIPING 105 D-F INDIRECT WASTE PIPINGWCOHWWCLFDSKØTYPCWHCINDIRECT WASTEVENT THROUGH ROOFIWVTRWASTEWSHOWERSHSHOWER HEAD AND MIXINGVALVESHOCK ABSORBERS "A"DESIGNATES SIZEAABOVE FINISHED FLOORAFFFIXTURE UNITSFUVALVE IN VERTICALVIVPIPE UNIONPLUMBING GENERAL NOTES:1.WASTE AND VENT PIPING PIPING SHALL BE DWV PVC, SLOPE HORIZONTAL WASTE PIPING AT 1/8" PER FOOT FOR PIPING 3"Ø AND LARGER, AND AT 1/4" PERFOOT FOR PIPING 2-1/2"Ø AND SMALLER, UNLESS OTHERWISE NOTED.2.CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES, PRIOR TO THE START OF CONSTRUCTION.3.CONTRACTOR SHALL VERIFY EXACT LOCATION OF ALL PIPING, SERVICES, UTILITIES AND EXISTING CONDITIONS IN FIELD, PRIOR TO THE START OFCONSTRUCTION.4.FOR ALL PIPING AGAINST BLOCK WALLS - INSTALL FURRED SPACE AS REQUIRED TO ACCEPT PIPING, CUTTING OF BLOCK NOT PERMITTED, UNLESSPERMITTED BY ARCHITECT IN WRITING.5.ALL AIR CONDITIONING CONDENSATE WASTES SHALL BE INSULATED WITH 1" THICK ARMAFLEX 25/50 PREFORMED PIPE INSULATION.6.INSTALL CLEANOUTS AS SHOWN, AND AS REQUIRED BY APPLICABLE CODES AND GOVERNING AUTHORITIES.7.CONTRACTOR SHALL VERIFY ALL OWNER FURNISHED EQUIPMENT (IF ANY) AND CONNECTIONS PRIOR TO START OF CONSTRUCTION.8.INSTALL SHUT-OFF VALVE AND UNION AT EACH PIECE OF EQUIPMENT.9.INSTALL INDIVIDUAL STOPS AT EACH FIXTURE.10.CONTRACTOR SHALL LOCATE ALL VALVES SO THAT THEY ARE COMPLETELY ACCESSIBLE.11.ALL FLUSH VALVES, FIXTURES STOPS, VALVES, ETC., ALL PLUMBING SHALL BE RIGIDLY SECURED (NO MOVEMENT WHEN OPERATED). INSTALL PERMANENTSTAMPED BRASS VALVE TAG.12.PROVIDE THE REQUIRED CLEARANCES AND SPACE FOR ALL PLUMBING FIXTURES. PLUMBING CONTRACTOR SHALL VERIFY AND COORDINATE PRIOR TOTHE START OF CONSTRUCTION.13.ALL PLUMBING TRADE ITEMS SHALL BE INDIVIDUALLY AND RIGIDLY SUPPORTED FROM STRUCTURE ABOVE INDEPENDENT OF ALL OTHER TRADES (DO NOTHANG PLUMBING TRADE ITEMS FROM ANOTHER TRADE).14.CONTRACTOR SHALL SUBMIT PLAN SHOWING ALL HOLES TO BE CORED IN STRUCTURE, DIMENSIONED ON 1/4" SCALE PLANS, TO ARCHITECT/ENGINEERFOR REVIEW, FOR ALL PIPING AND PENETRATIONS PRIOR TO START OF CONSTRUCTION.15.PHASING OF CONSTRUCTION SHALL BE DONE AS DIRECTED IN ARCHITECT'S CONSTRUCTION PHASING.16.DRAWINGS ARE BASED ON THE BEST AVAILABLE INFORMATION AT THE TIME OF DESIGN. CONTRACTOR SHALL VISIT AND THOROUGHLY INVESTIGATE SITE.ALLOWANCES SHALL BE MADE IN BID BY CONTRACTOR TO ALLOW FOR PLUMBING NOT AS SHOWN ON DRAWINGS AND FOR REMOVING OR RELOCATION OFPLUMBING SYSTEMS AS REQUIRED TO ACCOMPLISH INTENT OF DRAWINGS FOR A COMPLETE SYSTEM, DUE TO FIELD CONDITIONS DIFFERENT THANTHOSE SHOWN ON DESIGN DRAWINGS.17.DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FROM DRAWINGS, BUT FIT WORK TO ACTUAL CONDITIONS AND SPACE REQUIREMENTS.18.DRAWINGS ARE NOT INTENDED TO SHOW EVERY DETAIL OF WORK REQUIRED. CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS AS REQUIRED FORA COMPLETE AND ACCEPTABLE WORKING SYSTEM, WHETHER OR NOT SPECIFICALLY SHOWN ON DRAWINGS.19.ALL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY ANDPROPERLY OPERATIVE, AND IN COMPLIANCE WITH APPLICABLE CODES AND GOVERNING AUTHORITIES, AND SUBJECT TO ACCEPTANCE BYOWNER/ENGINEER.20.CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, FEES, INSPECTIONS AND TESTS.21.THE CONTRACTOR SHALL VISIT JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS PRIOR TO SUBMITTING BID.22.CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES TO AVOID INTERFERENCE DURING CONSTRUCTION.23.ALL REQUIRED INSURANCES SHALL BE PROVIDED AND MAINTAINED BY THE CONTRACTOR FOR THE PROTECTION AGAINST PUBLIC LIABILITY ANDPROPERTY DAMAGE, AND OTHER INSURANCES REQUIRED BY THE OWNER, FOR THE DURATION OF THE WORK.24.ALL MATERIALS AND WORK SHALL BE IN STRICT COMPLIANCE WITH APPLICABLE STATE AND LOCAL CODES, RULES, AND ORDINANCES.25.SUBMIT SHOP DRAWINGS FOR ALL FIXTURES, EQUIPMENT, AND MATERIALS.26.ALL MATERIALS SHALL BE NEW AND SHALL BE LISTED AND BEAR THE LABEL OF UNDERWRITERS LABORATORIES INC. WHERE APPLICABLE.27.DIELECTRIC COUPLINGS SHALL BE INSTALLED BETWEEN ALL DISSIMILAR METALS IN PIPING AND EQUIPMENT CONNECTIONS.28.ALL FIXTURES SHALL BE PROVIDED WITH INDIVIDUAL ACCESSIBLE STOPS. ALL EQUIPMENT SHALL HAVE INDIVIDUAL SHUT OFF VALVES.29.ALL WATER PIPING SHALL BE TYPE "L" COPPER ABOVE SLAB, TYPE "K" COPPER BELOW GRADE. ALL JOINTS SHALL BE MADE WITH LEAD FREE SOLDER.INSULATE HOT WATER PIPING ABOVE SLAB WITH 1" THICK FIBERGLASS PIPE INSULATION (R=4.0 MINIMUM) WITH STAY DRY JACKET, AND BELOW SLAB WITH2" THICK FOAMGLAS.30.INSTALL APPROVED AIR CHAMBERS OR PDI APPROVED SHOCK ARRESTORS AT EACH PLUMBING FIXTURE AND PIECE OF EQUIPMENT.31.THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINALACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED BY THE CONTRACTOR WITHOUT ADDITIONAL CHARGE, AND SHALL INCLUDEREPLACEMENT ND REPAIRS OF ANY OTHER TRADE WHICH MAY HAVE BEEN DAMAGED BY FAILURE OF PLUMBING TRADE WORK.32.CONDENSATE DRAIN PIPING SHALL BE DWV PVC. PIPING ABOVE GROUND SHALL BE INSULATED WITH 1" THICK ARMAFLEX 25/50 INSULATION, R=4.0INSTALLED.33.GENERAL NOTE: TEMPERATURE OF HOT WATER TO REST ROOMS SHALL NOT EXCEED 110°F, PER FLORIDA ENERGY CODE. CONTRACTOR SHALL VERIFYTEMPERATURE OF HOT WATER SYSTEM WITH OWNER. IF TEMPERATURE EXCEED 110°F, INSTALL TEMPERING VALVES AS REQUIRED, SUBJECT TO REVIEWBY ENGINEER.34.GENERAL NOTE: CONTRACTOR SHALL VERIFY EXISTING SYSTEMS, EXACT LOCATION, SERVICE, INVERT, SIZE, DIRECTION OF FLOW, ETC. PRIOR TO THESTART OF ANY OTHER CONSTRUCTION, AND MODIFY WORK SHOWN AS REQUIRED BY EXISTING CONDITIONS AND ACTUAL PIPE SIZES VERIFIED IN FIELDPRIOR TO ORDERING MATERIAL OR FIXTURES, SUBJECT TO REVIEW BY ENGINEER, TYPICAL THROUGHOUT JOB. LOCATIONS OF EXISTING SYSTEMS AREAPPROXIMATE.35.GENERAL NOTE: CONTRACTOR SHALL INCLUDE IN HIS BID THE FOLLOWING: RELOCATE, REWORK, REROUTE ALL PLUMBING SYSTEM PIPING ANDPLUMBING TRADE ITEMS AS REQUIRED BY NEW CONSTRUCTION AND AS REQUIRED THROUGHOUT THE JOB BY ALL TRADES.36.GENERAL NOTE: DO NOT INSTALL ANY PLUMBING PIPING OR SYSTEM COMPONENT IN THE SPACE ABOVE AN ELECTRICAL PANEL, TYPICAL THROUGHOUTJOB.37.GENERAL NOTE: NEW HVAC DUCTWORK SYSTEMS SHALL HAVE PRIORITY OVER PLUMBING SYSTEM. PLUMBING CONTRACTOR SHALL THOROUGHLYCOORDINATE PLUMBING SYSTEM WITH PROPOSED NEW WORK OF ALL TRADES, AND INCLUDE IN HIS BID THE COST OF RELOCATING AND REWORKINGNEW PLUMBING WORK, AS REQUIRED BY HVAC DUCTWORK. SPACE PERMITTING NEW HVAC DUCTWORK SHALL BE REROUTED AROUND PLUMBING PIPING.GENERAL CONTRACTOR SHALL COORDINATE ALL TRADES.38.CONTRACTOR SHALL INSTALL SWAY BRACING ON ALL PIPING AS REQUIRED BY THE FLORIDA PLUMBING CODE SECTION 308.6. ON EACH VALVE,COORDINATE WITH OWNER'S IDENTIFICATION SYSTEM.39.AIR CONDITIONING CONDENSATE TRAPS SHALL BE MADE UP OF UNIONS IN EACH SIDE OF TRAP, AND TRAP SHALL BE COMPLETELY REMOVABLE FORCLEANING. CONTRACTOR SHALL DEMONSTRATE TRAP REMOVAL PRIOR TO FINAL ACCEPTANCE.40.NO "SHOT-TYPE" FASTENERS WILL BE PERMITTED, USE LAG TYPE SCREW ANCHORS. SUBMIT FASTENER DETAILS TO STRUCTURAL ENGINEER FORREVIEW.41.CONTRACTOR SHALL SUBMIT ACCURATE "AS-BUILT" REPRODUCIBLE DRAWINGS TO THE ARCHITECT WITH ALL REVISIONS CLEARLY SHOWN. REVISE ALLFLOOR PLANS, NOTES, SCHEDULES, RISERS, ETC., USING THE SAME QUALITY OF DRAFTING AS ORIGINAL DOCUMENTS. PIPING, ETC., MUST BE SHOWN INACTUAL LOCATION INSTALLED NOT SCRATCHED ON DRAWING OR NOT JUST NOTED. "AS-BUILT" DRAWINGS ARE A REQUIREMENT OF THE CONTRACT, ANDJOB WILL BE CONSIDERED FINAL ONLY AFTER RECEIPT BY ARCHITECT, AND APPROVAL BY ENGINEER, OF "AS-BUILT" DRAWINGS. BACKGROUNDS FOR USEIN PREPARING "AS-BUILT" DRAWINGS WILL BE SUPPLIED BY ARCHITECT, AND PAID FOR BY CONTRACTOR. "AS-BUILT" DRAWINGS MUST BE SIGNED (NAMEAND TITLE TYPED BELOW SIGNATURE), DATED AND CERTIFIED BY CONTRACTOR AS BEING ACCURATE.42.FOR ANY EQUIPMENT FURNISHED BY OWNER OR OTHERS (IF ANY) , INSTALL ALL VALVING, WATER SUPPLIES, DRAINS, STRAINERS, ETC. VERIFY EXACTCONNECTION REQUIREMENTS PRIOR TO THE START OF CONSTRUCTION. PROVIDE AND INSTALL VACUUM BREAKERS ON ALL EQUIPMENT WITHOUT THEREQUIRED AIR GAP OR VACUUM BREAKER (HOSES, FILTERS, ETC.), AND UNION.43.INSULATION, FITTINGS COVERS, AND ALL FINISHES AND MATERIALS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKEDEVELOPED RATING OF 50.44.GENERAL NOTE: CONTRACTOR SHALL INCLUDE IN THERE BID ANY ITEM(S) SHOWN OR CALLED OUT ON THESE DRAWINGS EITHER SHOWN AS EXISTING ORNEW OR ANY ITEM NOT SHOWN OR CALLED OUT THAT IS REQUIRED TO COMPLETE WORK SHOWN. SHALL THERE BE A CONFLICT ON ANY ITEM FROMTHESE DRAWINGS AND ANOTHER TRADES REFERENCE TO AN ITEM OF THIS DISCIPLINE, THE CONTRACTOR IS RESPONSIBLE TO GET CLARIFICATION INWRITING SIGNED BY THE ENGINEER AND ARCHITECT PRIOR TO SUBMITTING BID AND INCLUDE SAID ITEM(S) IN THERE BID. IF A CONFLICT OR ITEM(S) NOTSHOWN THAT ARE REQUIRED TO COMPLETE WORK SHOWN IS FOUND AFTER BID HAS BEEN AWARDED CONTRACTOR IS RESPONSIBLE FOR THE MOREEXPENSIVE OPTION AT NO ADDITIONAL CHARGE TO THE OWNER. THE ARCHITECT AND ENGINEER SHALL INTERPRET ALL CONFLICTS. THE CONTRACTORBY BIDDING AGREES TO ABIDE BY THE ARCHITECTS AND ENGINEERS INTERPRETATION OF THE CONTRACT DOCUMENTS.ELECTRIC WATER COOLEREWCMOP SINKM.SKWCWATER CLOSET (PUBLIC AND STAFF, ACCESSIBLE, FLOOR MOUNTED): SIPHON JET, VITREOUS CHINA, 1-1/2" TOP SPUD, 16.5" HIGH,AMERICAN STANDARD #3465.001 "MADERA"; FLUSH VALVE: SLOAN EXPOSED MANUAL FLUSHOMETERS, MODEL#111-1.6-YO-DFB-TP (1.6 GPF) WITH B76A HANDLE, YK PIPE SUPPORT, F-72-A1 TRAP PRIMER ASSEMBLY (AS REQUIRED), ANDOFFSET TAIL PIECE (AS REQUIRED); ELONGATED OPEN FRONT SEAT WITHOUT COVER OLSONITE MODEL 95SSCT SELFSUSTAINING CHECK HINGE, SST POSTS. MOUNT ACCESSIBLE FIXTURE AT HEIGHT AND LOCATION PER ADA REQUIREMENTS OFTHE FBC, SEE ARCHITECTURAL ELEVATIONS.URURINAL (PUBLIC AND STAFF, ACCESSIBLE): VITREOUS CHINA WALL HUNG WASH OUT WITH INTEGRAL TRAP 1-1/4" TOP SPUD.AMERICAN STANDARD #6601.012 "LYNBROOK". FLUSH VALVE: SLOAN EXPOSED MANUAL FLUSHOMETER, ESCUTCHEON, INTEGRALSCREWDRIVER STOP, VACUUM BREAKER MODEL #180-1 (1 GPF) WITH DUAL FILTERED BY-PASS WITH CHROME PLATED FINISHMANUFACTURED BY SLOAN. FLOOR MOUNTED CARRIER: CAST IRON AND HEAVY DUTY STRUCTURAL STEEL FRAME WITHRECTANGULAR LEGS, LUGS FOR FLOOR AND WALL ATTACHMENT THREADED FIXTURE STUDS FOR FIXTURE HANGER BEARINGSTUDS, MANUFACTURED BY JOSAM. MOUNT ACCESSIBLE FIXTURE AT HEIGHT AND LOCATION PER ADA REQUIREMENTS OF THEFBC, SEE ARCHITECTURAL ELEVATIONS.LAVLAVATORY: (ACCESSIBLE, MANUAL FAUCET, WALL HUNG) VITREOUS CHINA WALL HUNG LAVATORY 20.5" WIDE BY 18.25" FRONT TOBACK, FAUCET HOLES 4" ON CENTER, RECTANGULAR BASIN FOR CONCEALED ARM SUPPORTS, FRONT OVERFLOW, MODEL0355.012 "LUCERNE" AS MANUFACTURED BY AMERICAN STANDARD. TRIM: CHROME PLATED FAUCET CHICAGO FAUCET MODELNO. 895-317ABCP WITH 3.5" SWING GOOSENECK SPOUT WITH VANDAL PROOF 0.5 GPM AERATOR, FLAT GRID STRAINER DRAINASSEMBLY, CHROME PLATED 17 GAUGE BRASS 1-1/4"Ø WITH CLEANOUT PLUG AND ARM PLATED ANGLE SUPPLIES WITH LOOSEKEY STOPS, WITH ESCUTCHEONS, FLOOR MOUNTED CARRIER FOR FIXTURE HANGER CONCEALED ARM SUPPORTS WITH HEAVYDUTY STRUCTURAL STEEL RECTANGULAR UPRIGHTS AS MANUFACTURED BY JOSAM, WITH INSULATED HOT WATER SUPPLY ANDWASTE WITH "HANDI-LAV-GUARD" AS MANUFACTURED BY TRUBRO INC. (WHITE). MOUNT FIXTURE TO WITHSTAND 300 POUNDVERTICAL FORCE ON FRONT EDGE OF FIXTURE. MOUNT AT HEIGHT AND LOCATION PER ADA REQUIREMENTS OF THE FBC, SEEARCHITECTURAL ELEVATIONS.G.LAVGROUP LAVATORY: (ACCESSIBLE, HAND PUSH BUTTON, WALL HUNG) HAND PUSH BUTTON OPERATED 5-60 SECOND ADJUSTABLETIMER SEMI CIRCULAR 3-STATION ADA COMPLIANT 14 GAGE 304 STAINLESS STEEL OFF FLOOR WASH FOUNTAIN. MANUFACTUREDBY ACORN ENGINEERING COMPANY MODEL 3423-ES-ADA-1-H-CB-ST-SPX, BOWL IS 38" WIDE, AND HAS AN INTEGRAL BACKSPLASHAND SPRAYHEAD. HEAVY-DUTY S-CLIPS SECURELY ANCHOR THE BACKSPLASH TO THE WALL. SPRAYHEAD IS 18 GAGE STAINLESSSTEEL 15" DIAMETER X 5-1/4" HIGH. SPRAY NOZZLES ARE VANDAL RESISTANT 0.5 GPM CONCENTRATED SPRAY AT EACH STATION.PROVIDE 1.5"Ø OD x 4" TAILPIECE. PROVIDE AN ASSE 1070 COMPLIANT TEMPERATURE/PRESSURE BALANCING MIXING VALVE WITHINTEGRAL CHECKS AND STRAINERS IN H & C SUPPLY AND FIELD SET WATER TEMPERATURE AT 105 DEGREES FAHRENHEIT.MOUNT FIXTURE TO WITHSTAND 300 POUND VERTICAL FORCE ON FRONT EDGE OF FIXTURE. MOUNT AT HEIGHT AND LOCATIONPER ADA REQUIREMENTS OF THE FBC, SEE ARCHITECTURAL ELEVATIONS.C.SKCOUNTER TOP HAND WASHING SINK (ACCESSIBLE, STAFF): SINGLE COMPARTMENT SINK, JUST MANUFACTURING MODELSLF-ADA-2125-A-GR, SINGLE COMPARTMENT, 21" FRONT TO BACK X 25" WIDE X 6.5" DEEP, 18 GAUGE 304 STAINLESS STEEL, SELFRIMMING, 3 HOLE, WITH CENTER REAR DRAIN LOCATION, WITH J-35 STRAINER WITH OFFSET DRAIN, AND 17 GAUGE P-TRAP WITHCLEANOUT PLUG, CHROME PLATED ANGLE SUPPLY STOP VALVES, CHROME PLATED ESCUTCHEONS, WITH JUSTMANUFACTURING MODEL JTR-51-W4 FAUCET WITH OPTIONAL 4" WRIST BLADES AND SWING SPOUT WITH 1.5 GPM RESTRICTINGAERATOR. MOUNT AT HEIGHT AND LOCATION PER ADA REQUIREMENTS OF THE FBC, SEE ARCHITECTURAL ELEVATIONS.SHSHOWER (ACCESSIBLE): SHOWER STALL BY OTHERS (SEE ARCHITECTURAL), THERMOSTATIC AND PRESSURE BALANCING SINGLECHROME PLATED LEVER VALVE, LEONARD MODEL SS-7600-100/31SA-D2L/501P(G)-44. SET TEMPERATURE AS PER FLORIDA STATEENERGY CODE REQUIREMENTS, WITH STRAINER AND INTEGRAL CHECK STOPS, ADJUSTABLE CHROME PLATED WALL/HANDSHOWER HEAD WITH FLEXIBLE HOSE AND BACKFLOW PREVENTER, 2.5 GPM ADJUSTABLE SPRAY SHOWER HEADS AND SELFTENSIONING SLIDE; WITH JOSAM 30002-S 2"Ø DRAIN WITH SQUARE NIKALOY TOP WITH SECURED GRATE AND FLASHING COLLAR,AND CHLORALOY SHOWER PAN. SHOWER STALL BY OTHERS (SEE ARCHITECTURAL DRAWINGS), COORDINATED BY PLUMBINGCONTRACTOR. MOUNT CONTROLS AND HAND SHOWER AT ACCESSIBLE HEIGHT AND LOCATION. FOR EXACT LAYOUT OF ALLSHOWER COMPONENTS TO COMPLY WITH ADA REQUIREMENTS OF THE FBC, SEE ARCHITECTURAL DRAWINGS.FDFLOOR DRAIN (FINISHED AREA): CAST IRON TWO PIECE BODY WITH DOUBLE DRAINAGE FLANGE, WEEP HOLES, REVERSIBLECLAMPING COLLAR AND 6"x6" SQUARE ADJUSTABLE NICKEL-BRONZE SECURED STRAINER SERIES 30003-6S-17-31-50MANUFACTURED BY JOSAM. PROVIDE 1/2" TRAP PRIMER RESEAL. PROVODE PRECISION PLUMBING PRODUCTS MODELPROU1-ULP500 TRAP PRIMER VALVE AT EACH FLOOR DRAIN. CHROME PLATED WHEN MOUNTED UNDER A LAV EXPOSED. DO NOTCONCEAL TRAP PRIMER VALVE, INSTALL IN ACCESSIBLE LOCATION.EWCELECTRIC WATER COOLER (HI-LO, ACCESSIBLE): TWO STATION, WALL MOUNTED, STAINLESS STEEL TOP AND BODY, ELEVATEDSOFT ANTI SQUIRT "FLEXI-GUARD" SAFETY BUBBLERS, AUTOMATIC STREAM REGULATORS, MODEL EZSTL8C MANUFACTURED BYELKAY, WITH JOSAM FLOOR MOUNTED CARRIER WITH HEAVY DUTY STRUCTURAL STEEL RECTANGULAR UPRIGHTS, 17 GAUGEBRASS P-TRAP WITH CLEAN OUT PLUG AND ARM, CHROME PLATED ANGLE SUPPLY WITH LOOSE KEY STOP, WITH CHROMEPLATED ESCUTCHEONS, 9.7 GPH, 370 WATTS, 115 VOLT 1 PHASE. MOUNT AT HEIGHT AND LOCATION PER ADA REQUIREMENTS OFTHE FBC, SEE ARCHITECTURAL ELEVATIONS.M.SKMOP SINK (FLOOR MOUNTED, CORNER): AMERICAN STANDARD MODEL 7741.000 "FLORWELL", 28"X28"X13, WITH NO. 7745.811REMOVABLE VINYL RIM GUARD, WITH 3" DRAIN WITH NO. 7721.038 FLAT GRID STRAINER, NO. 8344.112 FAUCET WITH TOP BRACE,INTEGRAL STOPS AND VACUUM BREAKER, IN POLISHED CHROME WITH POLISHED CHROME PLATED ESCUTCHEONS.S.SKSERVICE SINK (FLOOR/WALL MOUNTED): AMERICAN STANDARD MODEL 7695.008 "AKRON" SERVICE SINK ENAMELED CAST IRON,BOWL SIZE 19-7/8" WIDE X 16-3/8" FRONT TO BACK X 10-1/2" DEEP, WITH NO. 7798.030 3" P-TRAP DRAIN AND STRAINER, NO.8341.076 FAUCET WITH INTEGRAL STOPS AND VACUUM BREAKER, IN POLISHED CHROME WITH POLISHED CHROME PLATEDESCUTCHEONS.EW/ESCOMBINATION EMERGENCY EYE/FACE WASH/EMERGENCY SHOWER: HAWS CORPORATION MODEL 8300-8309 COMBINATIONSHOWER AND EYE/FACE WASH SHALL INCLUDE A STAINLESS STEEL 11" (27.9 CM) ROUND BOWL, AN AXION® MSR EYE/FACE WASHHEAD SHALL FEATURE INVERTED DIRECTIONAL LAMINAR FLOW WHICH ACHIEVES ZERO VERTICAL VELOCITY SUPPLIED BY ANINTEGRAL 3.7 GPM FLOW CONTROL. UNIT SHALL ALSO INCLUDE THE AXION MSR HYDRODYNAMIC DESIGNED ABS PLASTICSHOWERHEAD WITH 20 GPM FLOW CONTROL, CHROME-PLATED BRASS STAY-OPEN BALL VALVE EQUIPPED WITH STAINLESSSTEEL BALL AND STEM, AND CHROME-PLATED BRASS IN-LINE 50 X 50 MESH WATER STRAINER. UNIT SHALL ALSO INCLUDESCHEDULE 40 HOT-DIPPED GALVANIZED STEEL PIPE AND FITTINGS, POWDER-COATED CAST-IRON 9" (22.9 CM) DIAMETER FLOORFLANGE, SELF-ADHESIVE HIGH VISIBILITY SAFETY GREEN AND BRIGHT YELLOW STRIPES, UNIVERSAL SIGN, AND 1-1/4" NPTSUPPLY.HBCAST BRASS HOSE BIBB WITH 3/4" MALE NPT CONNECTION, CAST IRON HANDWHEEL, AND TAMPER-PROOF VACUUM BREAKER.WCO:WALL CLEANOUTS: LINE TYPE WITH CAST IRON BODY AND PLUG, AND ROUND STAINLESS STEEL ACCESS COVER SECURED WITHVANDAL PROOF SST SCREW, MODEL 58600 MANUFACTURED BY JOSAM.FCO:FLOOR CLEANOUTS: INTERIOR CAST IRON TWO PIECE BODY WITH DOUBLE DRAINAGE FLANGE, WEEP HOLES REVERSIBLECLAMPING COLLAR AND ADJUSTABLE NICKEL-BRONZE SQUARE TOP WITH SCORIATED COVER, MODEL 56020 MANUFACTURED BYJOSAM.GCO:GRADE CLEANOUT: EXTERIOR ROUND DUCTILE IRON ACCESS FRAME AND NON-SKID COVER: MODEL 56050-5 MANUFACTURED BYJOSAM PROVIDED 24"x24"x6" CONCRETE PAD WITH 6x6 - 10/10 WWF.A.GENERAL: COORDINATE SINK DIMENSIONS AND SPACE REQUIREMENTS WITH ARCHITECTURAL CABINETS, AND OBTAIN WRITTENAPPROVAL FROM CABINET FABRICATOR THAT SINKS WILL FIT INTO CABINETS, PRIOR TO ORDERING SINKS.B.GENERAL: INSTALL INDIVIDUAL SHUT OFF VALVES OR STOPS AT EACH FIXTURE AND PIECE OF EQUIPMENT. INSTALL SHOCKABSORBERS (PDI OR ASSE) IN AN ACCESSIBLE LOCATION AT EACH FIXTURE AND PIECE OF EQUIPMENT. INSTALL AUTOMATICTRAP PRIMER ON ALL FLOOR DRAINS. FIXTURES SHALL COMPLY WITH ADA AND STATE REQUIREMENTS FOR USE BYHANDICAPPED. WATER FLOW RATES AND CONSUMPTION OF ALL FIXTURES SHALL COMPLY WITH THE FLORIDA BUILDING CODE,TABLE 604.4 "MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS". WHERE FLOORMOUNTED CHAIR CARRIERS ARE SPECIFIED FOR LAVATORIES, CONTRACTOR SHALL MOUNT CARRIER AND FIXTURE (WITHADDITIONAL WALL STRUCTURAL SUPPORTS AS REQUIRED) TO WITHSTAND 300 POUND DOWNWARD VERTICAL FORCE AT FRONTEDGE OF FIXTURE, (CONTRACTOR SHALL COORDINATE REQUIRED CHASE REQUIREMENTS FOR FLOOR MOUNTED CARRIERSPRIOR TO THE START OF CONSTRUCTION), ALTERNATIVE FIXTURES MAY BE SUBMITTED BY CONTRACTOR AND APPROVED BYOWNER/ENGINEER PRIOR TO SUBMITTING BID.PLUMBING FIXTURE SCHEDULE:PLUMBING DRAWING LIST:P0.APLUMBING - GENERAL NOTES, SCHEDULES, CODES & LEGENDSP0.BPLUMBING - DETAILSP0.CPLUMBING - FIRE STOPPING DETAILSP0.DPLUMBING - SPECIFICATIONSP1.0PLUMBING - OVERALL FIRST FLOOR PLANP2.0PLUMBING - PARTIAL FIRST FLOOR PLANS & RISER DIAGRAMSP2.1PLUMBING - PARTIAL SECOND FLOOR PLANALL FIXTURES WHITEA.AMERICAN DISABILITIES ACT (CURRENT EDITION).FLORIDA BUILDING CODE - 7TH EDITION 2020 (WITH CURRENT REVISIONS & AMENDMENTS).FLORIDA ACCESSIBILITIES CODE FOR BUILDING CONSTRUCTIONH.ALL APPLICABLE CODES WITH LATEST REVISIONS.J.I.ASTM STANDARDS IN BUILDING CODES.U.L. BUILDING STANDARDSBUILDING MATERIALS DIRECTORYFIRE RESISTANCE DIRECTORYNFPA 101 - 2020 (FLORIDA FIRE PREVENTION CODE - 7TH EDITION WITH CURRENT REVISIONS).FLORIDA PLUMBING CODE - 7TH EDITION 2020 (WITH CURRENT REVISIONS & AMENDMENTS).F.G.C.B.BUILDING CODES TO FOLLOW:NFPA 90 - 2015.E.FLORIDA FUEL & GAS CODE - 7TH EDITION 2020 (WITH CURRENT REVISIONS & AMENDMENTS).D.Y:\Cardinal\Projects\21-08-15-00 Pursuit Product Development Center\Plumbing\21-08-15-00 Pursuit New Tooling Facility PLUMB-rev.dwg, P0.A, 11/17/2021 9:12:33 AM,Operator1