HomeMy WebLinkAboutA2.33 R3 ENLARGED PLANCON5TKUCTION LEGEND
EXISTING NON -BEARING INTERIOR 5TUD WALL - NON -RATED
MTL. STUDS W/ GYPSUM WALLBOARD EACH SIDE.
EXISTING INTERIOR NON -SEARING STUD WALL TO DE REMOVED
NEW INTERIOR STUD WALL - NON -RATED - FULL HEIGHT
3 5/8", 25 GA. MTL. STUDS 016" O.C. W/ (1) LAYER 5/8"
GYPSUM WALLBOARD EACH SIDE & 3" SOUND ATTENUATION
DLANKETS FROM 5LAB TO 6" ABOVE THE CEILING.
NEW 2'X2' RECE55ED LED LIGHT FIXTURE
SEE KAMM ENGINEERING ELECTRICAL DRAWINGS FOR
SCHEDULE AND INFO.
NEW 2'X2' ACOUSTICAL CEILING TILE
SEE KAMM ENGINEERING DRAWINGS FOR DIFFUSER
LOCATIONS AND INFO.
OFFICE
0
ENTRANCE
0
OFFICE
0
OFFICE
0
OFFICE
0
OFFICE
0
NOTES
1. PROTECT AND MAINTAIN EXISTING RIGID FRAME STRUCTURE AND COLUMNS ADJACENT TO
STRUCTURE BEING DEMOLISHED.
2. PROTECT EXISTING 4" FLOOR DRAINS.
3. BRACE EXISTING FRAMING WALLS AND CEILING STRUCTURE TO REMAIN PRIOR TO DEMOLITION.
FIELD VERIFY WALL AND CEILING STRUCTURE TO REMAIN WILL 5E 5ELF-5UPPORTING ONCE
ADJACENT WALLS AND CEILING ARE REMOVED. NOTIFY ARCHITECT OF FINDINGS.
4. REMOVE AND DISPOSE OF ALL EXISTING ELECTRICAL CONDUITS, WIRING, LIGHT FIXTURES,
JUNCTION BOXES, ETC. SAFE OFF ALL ELECTRICAL CIRCUITS PRIOR TO ELECTRICAL DEMOLITION.
SEE ELECTRICAL DRAWINGS FOR MORE INFO.
5. REMOVE AND DISPOSE OF ALL EXISTING VENTILATION EQUIPMENT, DUCTWORK, LIGHT FIXTURES,
ELECTRICAL CONDUIT/WIRE, JUNCTION BOXES, ETC. SAFE OFF ALL ELECTRICAL CIRCUITS
ASSOCIATED WITH REMOVED VENTILATION EQUIPMENT, LIGHTING AND ELECTRICAL JUNCTION
13OXE5 PRIOR TO DEMOLITION OF THE ROOMS A5 SHOWN ON MEP ENGINEER'S PLAN.
6. CUT EXISTING FRAMING WALL AT LOCATIONS SHOWN ON FLOOR PLAN, NEAT AND CLEAN. PATCH
AND REPAIR REMAINING FRAMING WALL CORNERS, AS NEEDED, TO MAINTAIN STRUCTURAL
INTEGRITY AND FINISH.
7. REMOVE EXISTING 3-0 X 7-0 DOORS & FRAME.
8. PREPARE OPENING TO RECEIVE NEW 3-0 X 7-0 HOLLOW METAL DOOR & FRAME W/ 1 PUSH,1
PULL,1 KICK PLATE,1 CLOSURE & 1-1/2 55 HINGES.
9. PREPARE OPENING TO RECEIVE NEW 3-0 X 7-0 HOLLOW METAL DOOR & FRAME W/ 1 PA55AGE
LOCK5ET & 1-1/2 5D HINGES.
10.DEMO TOILET PARTITIONS AS SHOWN ON FLOOR PLAN.
11. DEMO EXISTING WALL FINISHES IN 5ATHROOMS AND REPLACE WITH LIKE KIND AS NECESSARY.
12.DEMO FLOOR TILE, REPLACE WITH LIKE KIND A5 NECESSARY.
13.PROVIDE NEW SOLID PHENOLIC CORE TOILET PARTITIONS.
14.THE FOLLOWING ACCESSORIES TO 5E PROVIDED ON EACH ADA STALL: (1) 42" & (1) 56" 1-1/2"o
GRAD 5AR5.
15.PROVIDE NEW 18"X20" 55 TRIM MIRRORS.
16.PROVIDE NEW HEADER, FINISHED BOTTOM AT 7-0" AFF.
MOTOR
PREP
0
NOTE: COORDINATE WITH KAMM ENGINEERING DRAWINGS AND SPECS.
03pKoFosEn Kcp
--
5CALE: 1/4" = 1'-0"
f roject:
KE N OVATI O N
FOK
CONTENDEK BOATS
5701 ENVIRONMENTAL DRIVE
ST. LUCIE COUNTY, FLORIDA
Key Fla ri
55ue5:
No.: Date: Description:
A. 12/17/21 PERMIT RESPONSE 3
D ONAD I O
& Associates, Architects P.A.
2001 9th Avenue, Suite 308
Vero Beach, FL 32960
Te1.772.794.2929
Fax.772.562.8600
www.donadio-arch.com
License No. AA0002238
Consultant:
Drawing Title:
ENLAKGED FLAN
KE5TKOOM5
Reference North
.�, owr 1
0:
• :s
�• /�QO�Iffii t
Drn: Drawing File:
MT
Chd: XREF File:
AJD
Project No.: Plot File:
2020-33
01 ADMIN15TI2ATIVE OFFICES -EXISTING &DEMO PLAN
5CALE: 1/4" =1'-0"
OZ p120p05ED TOILET CHANGES
5CALE: 1/4" = 1'-0"
04- EXISTING KESTKOOMS
5CALE: 1/4" = 1'-0"
Date
Sheet No.:
A2.33