Loading...
HomeMy WebLinkAboutA6.10 R0 Schedulesd00K 5CHEDUL_E cfl z O DOOR 51ZE DOOR FLAME o _j w Dz .-. Z w V- Q z w w Q o Dz Q : m Z O w m O Q w H Q c= >L LU LLI Q � Q w 1— 11 DETAILS (SEE REMARKS) n m z Q o Q WIDTH X HEIGHT THICKNESS FIRST FLOOR 101 16-0" X 20'-0" - D ST - F - - - 53 J3 - H3 - - - STEEL ROLL-UF DOOR 101 102 3'-0" X 7'-0" 1 3/4" A HM - F A HM F 52 J2 - H2 ADA - 02 102 103 3'-0" X 7'-0" 1 3/4" A HM - F A HM F 52 J2 - H2 ADA - 02 103 104 (2) 3'-0" X 7-0" 1 3/4" A HM - F B HM F 52 J2 - H2 - - 01 104 105 3'-0" X 7-0" 1 3/4" A HM F A HM F 52 J2 H2 ADA 02 105 106 3'-0" X 7-0" 1 3/4" A HM F A HM F 52 J2 H2 ADA 02 106 107 3'-0" X 7-0" 1 3/4" A HM F A HM F 52 J2 H2 ADA 02 107 201 3'-0" X 7-0" 1 3/4" C HM - F A HM F 51 11 - H1 - 03 201 202 3'-0" X 7-0" 1 3/4" C HM - F A HM F 52 J2 - H2 - 02 INSULATED DOOR 202 203 203 LVK = FULLY LOUVERED HCW = HOLLOW COKE WOOD WD = WOOD GYF = GYF5UM BOAKD AN = ANODIZED RG = RATED GLASS K = KYNAR (FIRELITE FLU5) G5 = GALVANIZED STEEL 5CW = SOLID CORE WOOD MTL = METAL MRB = M015TURE KE51TANT GYF. FL = FLA5TIC LAMINATE. F = FACTORY FIN15H FG = 1`I13ERGLA55 WD = WOOD TF = TEMFEKED IG = GREY TINTED, IMPACT BV = BIRCH VENEER F = FAINT KE515TANT GLA55 Hardware Group No. 1 For use on Door #(s): 104 Provide each PR door(s) with the following: QTY DESCRIPTION CATALOG NUMBER 6 EA HINGE 5661HW 4.5 X 4.5 NRP 2 EA SURFACE BOLT SB360 12" T 1 EA STOREROOM LOCK T581 P6 DAN 2 EA SURFACE CLOSER SC71A SS 2 EA KICK PLATE 8400 10" X 1" LDW B-CS 1 EA RAIN DRIP 11A 1 EA GASKETING 8144SBK PSA 2 EA DOOR SWEEP 539AA 1 EA THRESHOLD 566A METAL Z ASTRAGAL BY DOOR MANUFACTURER Hardware Group No. 2 For use on Door #(s): 102 103 105 202 106 Provide each SGL door(s) with the following: QTY DESCRIPTION CATALOG NUMBER 3 EA HINGE 513131 HW 4.5 X 4.5 NRP 1 EA PANIC HARDWARE HH-25-R-L-NL-DANE-299F 1 EA MORTISE CYLINDER C987-6CCA 1 EA SFIC CORE C606 1 EA SURFACE CLOSER SC71A SS 1 EA KICK PLATE 8400 10" X 2" LDW B-CS 1 EA RAIN DRIP 11A 1 EA GASKETING 8144SBK PSA 1 EA DOOR SWEEP 539AA 1 EA THRESHOLD 566A Hardware Group No. 3 For use on Door #(s): 201 Provide each SGL door(s) with the following: QTY DESCRIPTION CATALOG NUMBER 3 EA HINGE 56131 HW 4.5 X 4.5 1 EA PANIC HARDWARE 25-R-L-DANE 1 EA MORTISE CYLINDER C987-6CCA 1 EA SFIC CORE C606 1 EA SURFACE CLOSER SC71A REG OR PA AS REQ 1 EA KICK PLATE 8400 10" X 2" LDW B-CS 1 EA WALL STOP WS406/407CVX 3 EA SILENCER SR64 Hardware Group No. 4 For use on Door #(s): 101 Provide each RU door(s) with the following: QTY DESCRIPTION CATALOG NUMBER ALL HARDWARE BY DOOR MANUFACTURER 107 POOK FRAME POOK FRAME TYf E 'A' TYf E '13' FINISH MFR 630 IVE US2C IVE 626 FAL 689 FAL 630 IVE A ZER BK ZER AA ZER A ZER H3 HEAD DETAIL OVE DOC FINISH MFR 630 IVE 626 FAL 626/BL FAL K 626 FAL 689 FAL 630 IVE A ZER BK ZER AA ZER A ZER H1 HEAD DETAIL FINISH MFR 'DRYWALL ON 6" V. METAL 5TUD5 AND )USTICAL BATT5 J LATION 13LE 5TUD5 AT J AM B5. (TYP) WOOD FRAME LOW METAL DRYWALL ME SCALE: 3"=1'-O" FKE-ENGII BUILDING FKE-ENG. CLOSURE FRE-ENG. HEADERU SEALANT FA5TENEF H.M. D00P H2 HEAD DETAIL BLDG. MANUF. SEALANT H.M. DOOR FRAME 652 IVE 626 FAL 626/BL FAL SEALANT K DOUBLE 5TUD5 AT ROLL -UP DOOR — 626 FAL ALL JAM55.(TYF) DOOR GUIDES — 689 FAL F.E. BLDG. Z-GIRT H.M. POOK FRAME SEE SHEET 5-5 630 IVE 5UBFRAME ni FOR ATTACHMENT = 630 IVE / // HOLLOW METAL GRY IVE DRYWALL FRAME H.M. DOOR, SEE SCHEDULE FINISH MFR J JAMP DETAIL 51 51LL DETAIL SCALE: 3"=1'-O" AF RE5HOLD SCALE: 3"=1'-0" F.E. BLDG. SUB -JAI FKE-ENGINEEKED BUILDING WALL FAI FKE-ENGINEEKED I J2 JAMB DETAIL H.M. DOOR 1/2" MAX ADA COMPLIANT ALUM. THRESHOLD 52 51LL DETAIL 5EALANT 5ca le: 3"=1'-0" Scale: 3"=1'-D" J3 JAMP DETAIL IN5ULATEn n\/r:pi-lCAn rnii wc- nnnn DOOR BO" CONCRET GJJ SILL DETAIL MING AND BLOCKING TO RECEIVE DOOR :HANISM, DESIGNED TO MEET WIND LOADS CATED ON THE STRUCTURAL DRAWINGS > ROLL-UF DOOR LOADS. SEE STRUCTURAL WING5. IRT BY F.E. 13LDG. MANUF. -ENGINEERED BUILDING .L FANEL5 -ENG. BLDG. SURE -ENG. BLDG. PEK DRIP TRIM +20'-0" A.F.F. DOT. GIRT -ENG. BLDG. FINISHED DER TRIM OVER C-GIRT L-UF DOOR MANUF'5 DETAILS) 5c9le: 3"=1'-0" FRE-ENG. BLDG. TRIM FKE-ENGINEEKED BUILDING WALL FANEL5 C-JAMB & DOOR GUIDE 5UFFOKT DESIGNED TO MEET WIND LOADS INDICATED ON THE STRUCTURAL DRAWINGS AND KOLL-UP DOOR LOADS. SEE STRUCTURAL DRAWINGS 50a le: 3"=1'-0" ithony Digitally s g1 by Anthony JDonadio • Date: 202.( Donadio 13:07:34 - 4 project: KE N OVATI 0 N I=OK CONTENDEK BOATS 5701 ENVIRONMENTAL DRIVE ST. LUCIE COUNTY, FLORIDA Key Ilan 55Uco: No.: Date: Description: A. 05/11/21 REVIEW D. 05/25/21 REVIEW C. 06/25/21 PERMIT SET DONADIO & Associates, Architects P.A. 2001 9th Avenue, Suite 308 Vero Beach, FL 32960 Te1.772.794.2929 Fax.772.562.8600 W W W.donadio-arch.com License No. AA0002238 Consultant: Drawing Title: SCHEDULES & DETAILS Reference North �.... Drn: Drawing File: MT Chd: XREF File: e i *... s AJD Project No.: Plot File: 2020-53 •• Sheet No.: Date A 6.10