Loading...
HomeMy WebLinkAboutAluminum Single Hung WindowTHESE WINDOWS ARE RATED FOR LARGE & SMALL MISSILE IMPACT. SHUTTERS ARE NOT REQUIRED. SERIES 2500 ALUMINUM SINGLE HUNG WINDOW DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHART SHOWN ON SHEETS 2 & 2.1. APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WITH OTHER F.B.C. APPR'D WINDOWS USING F.B.C. APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. FALSE MUNTINS (SURFACE APPLIED) MAY BE USED 53 1/B• IDOW WIDTH 50 1/4' OPG. (FIXED) 14 3/8' MAX. HEAD/SILL I 5" MAX. TYp. I u ii D I I u II II M p II II tE ,� u u .n- w B D = � o o 3 n z II II = rg� � a II 11 li 11 M .�•, H A WINDOWS WITH SILL ANCHORS 48 3/4' SEE SHEET 2 O.L OPG. FOR CAPACITIES THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (BTH EDITION)/2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERUALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. DESIGN LOADS SHOWN ARE BASED ON 'ALLOWABLE STRESS DESIGN (ASD)'. MANUFACTURER'S LABEL SHALL BE LOCATED ON A READILY VISIBLE LOCATION IN ACCORDANCE WITH SECTION 1709.9.3 OF FLORIDA BUILDING CODE. LABELING TO COMPLY WITH SECTION 1709.9.2. 51' FALSE MUNTINS (SURFACE APPLIED) MAY BE USED \ WINDOWS WITHOUT SILL ANCHORS SEE SHEET 2.1 FOR CAPACITIES TYPICAL ELEVATION TESTED UNITS u u n n 3 ii l 48 3/4' D.L. OPG. 51' EAMINATED GLASS LARGE MISSILE IMPACT >n FL #21857 CONTRACTOR TO BE RESPONSIBLE FOR THE SELECTION. PURCHASE AND INSTALLATION OF THIS PRODUCT BASED ON THIS PRODUCT EVALUATION PROVIDED HE/SHE DOES NOT DEVIATE MOM THE CONDITIONS DETAILED ON THIS DOCUMENT. THIS PRODUCT EVALUATION DOCUMENT WELL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. SITE SPECIFIC PROJECTS SHALL BE PREPARED BY A FLORIDA REGISTERED ENGINEER OR ARCH"M WHICH WIN. BECOME THE ENW W OF RECORD (CO-R.) FOR THE PROJECT AND WHO WILL BE RESPONSIBLE FOR THE PROPER USE OF THE P.E.D. ENGINEER OF RECORD. ACTING AS A DELEGATED ENGINEER TO THE P.E.D. ENGINEER SHALL SUBMIT TO THIS LATTER THE SITE SPECIFIC DRAWINGS FOR RENEW. THIS P.E.O. SHALL BEAR THE DATE AND ORIGINAL. SAW. AND SIGNATURE OF THE PRDFESSIONAL ENGINEER OF RECORD THAT PREPARED IT. tip No. 81223 xY fi E tr RT (10 �v w F 2m ®°y`e mH 0 G'0 F cy mgg 0aoo W LLzy=� Growing no. W15-60 EQUAL LITES WINDOWS DESIGN LOAD CAPACITY - PSF WINDOWS WITH SILL ANCHORS WINDOW DIMS. GLASS TYPES A•• 'B' & 'D' MOTH HEIGHT EXT.(+) 1NT.(-) 19-1/8' 26-1/2' 37" 42' 48' 53-1/8' 26" (3) 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 19-1/8' 26-1/2' 37' 42' 48" 53-1/8' 38-3/8' (4) 70.0 90.0 70.0 90.0 70.0 9D.0 70.0 90.0 70.0 90.0 70.0 90.0 19-1/8• 26-1/2' 37' 42" 48" 53-1/8" 50-5/8' (4) 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 70.0 90.0 60.0 65.0 19-1/8' 26-1/2' 37• 42" 48" 53-1/8' 59" (5) 70.0 90.0 70.0 90.0 711 90.0 - 65.0 80.0 65.0 60.0 65.0 19-1/8' 26-1/2• 37" 42" 48" 53-1/8" 63' (6) 70.0 90.0 70.0 90.0 70.0 90.0 60.0 65.0 60.0 65.0 60.0 65.0 19-1/8' 26-1/2' 37" 42" 48' 53-1/8" 74-1/4' (6) 70.0 90.0 70.0 90.0 60.0 65.0 60.0 65.0 60.0 85.0 60.0 64.5 19-1/8' 26-1/2' 37' 42" 48' 51' 76" (6) 70.0 90.0 70.0 90.0 60.0 65.0 60.0 65.0 60.0 65.0 60.0 I65.0 NO. IN PARENTHESIS INDICATE NO. OF ANCHORS PER JAMB. NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219 1/8" ANN. GLASS .090' Interlayer Classlom Safety -Plus II By 'Polymer Extrusion Technology, Inc.' PET FLAP 1\ 1/8" ANN. GLASS .010" X 5/8' 11 EMBEDED IN SILICONE �u SILICONE i m GE 2800 to O 6 - FOAM TAPE AT 1/4 POINTS ON LITES 18 WIDER THAN 36" GLASS TYPE 'A' 1/8' ANN. GLASS 090' Interlayer Saflex Clear And Color Glass By 'Eastman Chemical Co.' PET FLAP 1/8' ANN. GLASS .010• X 5/8' EMBEDED � \ IN SILICONE SILICONE i m `GE 2800 5 N UNEQUAL I= (ORIEL TYPES) WINDOWS DESIGN LOAD CAPACITY - PSP WINDOWS WITH SILL ANCHORS WINDOW DIMS. GLASS TYPES 'A', 'B• & 'D' WIDTH HEIGHT EXT.(+) 1NT.(-) 19-1/8' 26-1/2• 1. 42' 48" 53-1/8' 50-5/8" (4) 70.0 90.0 70.0 90.0 70.0 90.0 60.0 05.0 60.0 65.0 60.0 65.0 19-1/8• 26-1/2' 37" 42• 48' 53-1/8' 59" (5) 70.0 90.0 70.0 90.0 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 19-1/8' 26-1/2• 37' 42" 48" 51" 63" (6) 70.0 90.0 70.0 90.0 60.0 65.0 60.0 65.0 60.0 65.0 60.0 65.0 19-1/8' 26-1/2' 37" 74-1/4' (6) 70.0 90.0 60.0 65.0 60.0 65.0 19-1/8 26-1/2 37' 76' (6) 70.0 90.0 60.0 65.0 60.0 65.0 • NO. IN PARENTHESIS INDICATE NO. OF ANCHORS PER JAMB. 1/8" HEAT STREN'D GLASS .090' Interoyer Saflex Clear And Color Glass By 'Eastman Chemical Co.' 1/8' HEAT STREWD GLASS SILICONE r GE 21100 DOWSIL f DOWSIL 18199 Z y n 0� qn N_ # W QCL Y6 a xri O ♦Y Q�O o7o i 0dN a U ;! a \ _ C�ia'�+ ci 00 0a0<$ -0 -W ♦'Y law M z In JBig Q(vumE� O J WINDOWS WITH g SILL ANCHORS U o 0 E: �yy1 c c J�J 6 o s2 W . 7 ``i3 aO 01 Q N F C- �1 Fyn m FOAM TAPE No. e1223 18 E AT 1/4 POINTS ON LITES AT 1/4 POINTS ON LITES - - o 18 WIDER THAN 36' WIDR THAN 36" �-a '' GLASS TYPE `B' GLASS TYPE 'D' Sealed: 10/13/2020 '� ' ��:� drawing no. GLAZING OPTIONS FL #21857 ///fffff�111111�1�\\ sheet 2 of 5 N Qo m N m al m al N m N N a! m N d) N N m rj m � C fMn o� ,No o�� o o� o 0 0 0 o 0 0 0 0 o m 0 o o 0 0 0�? N O O C C O N G O O O C O O O C O O O O O O iJ O m O O C C � •a N ODO I7z c06 5� 10 �o moM., oZ 00 D C)Azv v �n>� �Fmcn min 3 'Z (A Z v moo 00,0 K O �t�Wm o rn ts m c1 r� c m aJ EXTERIOR H n N 2 Oo3 O tjd me ? ��`•: n oZ s 30 Syr A N i 3/8' MIN. TYP. �_ c z N GLASS BITE 0 z b 12 O z EXTERIOR O m m z 2 D 2 O � OZ •[7 m t7 � i m ymy 0 O O A 2 000W = L7ylm� JQS� Io1nn 00.0Iz,1 �1yn1 3 N yA m 00 z a O 0 m N o z O 3/8• MIN. TYP. ^� GLASS BITE 1n CD w to �• H r o O � O p P•�� �_ rri 15-11/16• MIN. D.L.O. HT. ✓o IZ AT VENT �i�••.• ter. 1y�1111```�� a n dale: 08-22-15 revisions: SERIES 2500 ALUM SINGLE HUNG WINDOW (LM.I.) AL-FAROOQ CORPORATION infc escn Ionlo Windows & Dools, LLC ENGINEERS&PRODUCT DEVELOPMENT 9360SUNSETDRIVE, SURE 220 d/6/a AWPindows dt Doors MIAMI, FLORIDA 33173 (C.6.N. 3538)1543 N. Power6ne Road TEL(306) 29"100 FAX. (305) 262-G 713 o Pompon Beach, FI. 33069 0 c br Tel. 305) 887-2646 Fax. (-)1.COMP-ANL\W15-60AWP OH- zo • n\i 0\0 • N m r N m m N � � \ a� Z P �. o .. � [! Z a In ZdC o s D�r yX%m pT, O O qO� m O O a. N O O m m O D m N O D rn m O O g, m O m O O m O O O+ 0 0 O Rena N N 0 o U N b o N In o e N N o 0 lmll N 0 0 N N 0 0 +' to � a N U o 0 N N 0 o Oi W m o lm)1 N 0 0 W N�� 0 o v r? r �•i ,� y aa al I N•J °i O 0 o O o O J O) O) D o Ol Ol 0 0 V V 0 o Q, C, D o a, O1 o D J J o o N m o �l 0 0 v v 0 0 O y 0 o b o 0 0 o c o 0 0 0 0 0 0 0 0 o is 0 o c c o v� � N - m m N m m a m m m N m m m 0 H 0 0 0 0 i0 O O V O O •� J TYPICAL ANCHORS 1/4" TAPCONS SEE ELEV.` FOR SPACING na Qa' a EbGF- DIST. O " 4 1BY WOOD BUCK x � EDGE o d. DIST. R N —s O x TYPICAL ANCHORS 1/4" TAPOONS 1 SEE ELEVS. FOR SPACING TO LATCH ..� •yl�° 41 , 1 L °I I 1p rn III ° I LI, TYPICAL ANCHORS 1/4- TAPCONS USE WHEN REOUIRED SEE SHEET 2 FOR CAPACITIES SEE ELEV. FOR SPACING � I III EDGE 1D(ST`. TYPICAL ANCHORS #14 SMS WOOD BUCKS AND METAL STRUCTURE NOT BY 'AWP WINDOWS' SEE ELEVS. FOR SPACING MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM METAL AND TRANSFER THEM TO THE BUILDING STRUCTURE. rSTRUCTURE O F• h m TYPICAL ANCHORS: h � F SEE ELEV. FOR SPACING •1TW' 2 O 1/4' DIA. TAPCON BY (F-125 KSI, Fy-IGO KSI) 1/4' DIA. ULTRACON+ BY 'DEWALT' (Fu=ts4 KSI, Fy-i4s Ks) p o L� 0 ul ( u s INTO 28Y WOOD BUCKS OR WOOD STRUCTURES 1-1/2' MIN. PENETRATION INTO WOOD (HEAD/SILL/JAMBS) it o = a 0 ti y� THRU 1BY BUCKS INTO CONC. OR BLOCKS c & g 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) doQ 1-1/4" MIN. EMBED INTO BLOCKS (JAMBS) 0 a °- DIRECTLY INTO CONCRETE OR BLOCKS Q w = g 1-1/4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) ILZ= n r-----------_=_�____� r---------- 1 1-1/4' MIN. EMBED INTO BLOCKS (JAMBS) I F•B.C. APPROVED I I J 0 8 2 2 n! I1 MULLION & MULLION ANCHORS ; �114 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) II SEE SEPARATE APPROVAL a W m 2 0 U II it EDGE INTO METAL STRUCTURES (HEAD/SILL/JAMBS) DIST. (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) J '--- '--- - - STEEL• 1/8" THK. MIN. (Fy = 36 KSI MIN.) 30 (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) z �I12 SMS OR SELF DRILLING SCREWS (GRADE 2 CRS) INTO F.B.C. APPROVED MULLIONS o ! (3) THREADS MIN. TO EXTEND BEYOND METAL THICKNESS = m 4 ° @ TYPICAL ANCHORS ALUMINUM: 1/8" THK. MIN. (6063-T5 MIN.) (NO SHIMS) a 8 n a SEE ELEV. FOR#12 SPACING STEEL: 1/8" THK. MIN. (Fy = 36 KSI MIN.) (NO SHIMS) �+ o w (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) m TYPICAL DISTAN . a s m INTO CONCRETE AND BLOCKS = 2" MIN. QQ INTO WOOD STRUCTURE - 1" MIN. o Z o 'S� E INTO METAL STRUCTURE = 3/4" MIN. ' WOOD AT HEAD, SILL OR JAMBS SG - 0.55 MIN. 0 CONCRETE AT HEAD, SILL OR JAMBS Cc - 3000 PSI MIN. C-80 HOLLOW/FILLED BLOCK AT JAMBS Pm - 2000 PSI MIN. nrnTm SEALANTS: ALL JOINTS AND FRAME CONNECTIONS SEALED WITH SCHNEE MOREHEAD SEAM SEALER SM5555. `VEEPHOLES: W1 = 3/4" WEEP NOTCH AT EACH END / No.01223 \ ~ Sealed: 10/13/2020 %�' .. .. •����.��� W15-60 FL #21857 / TTT IL111\` sheet 3 of 5 aI+ u �I NI Z m 1 pbj Q ' Z. a a Q 2 2 p 1 IL 5 m �I Q Wq`m V �o TYPICAL ANCHORS p APPROVED MULLION SEE ELEV. FOR SPACING O a Q g SEE SEPARATE APPROVAL N N O Qwz w^ e $� I It Q W M S F I I O J 11 II ._. o L___J 1 3 I z 0 U 2 LL 1d o WINDOW WIDTH WINDOW WIDTH Z g m a M N 09 �4 TYPICAL ANCHORS SEE ELEV. FOR SPACING SEE SHEET 2 & 2.1 FOR CAPACITY o v O. 4'N ro TYPICAL ANCHORS off= °a 1/4' MAX. D 1/4" SHIM SEE ELEV. FOR SPACING I� SHIM MAX. SEE SHEET 2 & 2.1 FOR CAPACITY) a r VENT WIDTH O 13 D.L. G. KWOODCK OR 7 22 9 1/4- SHIM URE 10 MAX. METALSTRUCTURE _ _ - _ _ _ _ _ _ _ _ _ _ _ 1 0 21W8 PICAL ANCHORS °EXTERIOR ''' E ELEV. FOR SPACING 5 3 SEE SHEET 2 & 2.1 FOR CAPACITY m c D.L. OPG. ak� WOOD BUCKS WINDOW WIDTH �• , No.81223 ��()• 3T •(qs��ij Sealed:10/13/2020 FL #21857 �Y�` l'L'EAT / PART / REQD. DESCRIPTION MATERIAL MANF./SUPPLIER/REMARRS 1 YE-169 1 FRAME HEAD 6063-T6 - 2 YE-167 1 FRAME SILL 606S-T6 - 3 YE-102 2 FRAME JAMB 6063-Tfi - 4 YE-152 1 FIXED RAIL 6063-T6 5 YE-151 1 VENT TOP RAIL 6063-T6 6 YE-168 1 VENT BOTTOM RAIL 6063-T6 - 7 YE-92 2 VENT JAMB 6063-76 - 8 YB-4 AS RE00. GLAZING BEAD ALUMINUM ROLL FORMED 9 YH-516 2/ VENT SASH STOP RIGID VWri - f0 - 2/ VENT BLOCK &TACKLE BALANCE - - 11 YH-505 2/ VENT B4LAt10E CUP ALUMINUM - 12 YH-622 AS REQO. BULB W'STRIPPING VINYL SINGLE ROW 13 YH-4004 AS READ. FIN SEAL W'SIRIPPING .t87 X .250 WOOL ULTRAFAB 14 YH-504 2/ VENT SPRING LOADED VENT LATCHES NYLON/CELCON AT 11' FROM ENDS 14A YH-515 2/ VENT SWEEP LOCKS ZAMAI( AT I1" FROM ENDS 15 YF-1 B FRAME ASSEMBLY SCREWS (/10 X 3/4') CRS PLATED, PH SMS 16 YF-10 2/ VENT FIXED RAIL SCREWS (/B X 17 CRS CAD PUTED, PH SMS 17 YF-12 6/ VENT VENT ASSEMBLY SCREWS (/B X 1-1/4') CRS CAD PLATED, PH SMS 16 - AS REOD. SETTING BLOCKS EPOM DUROMETER 8035 SHORE A 19 YF-6 1/ CUP /10 X 1/4' PH SMS POINT B - - 20 YF-14 2/ LOCK SWEEP LOCK SCREWS (/B X 5/87 - ON SMS 21 YC-155P 2/ VENT SELF ADHESIVE PAD (.375" X .31' % .75') FOAM - 22 YN-519 2/ VENT BALANCE CAM PLASTIC - 23 YM-519 1 REINFORCING BM (.627 X .3127 STEEL HR093 24 - 2/ VENT SASH STOP (1' % 1-1/4' X I/167 ALUMINUM ON 74-t/4" HIGH ONLY rn v 2.220 I 055 889 1327 827 .860 FRAME HEAD -y .812 �1�.062 �I L 1.062 pi FIXED RAIL r-999V99991 1.187 I 055 III JII 1.625 —i 912 VENT TOP RAIL 3. VENT BOTTOM RAIL FRAME 1.1251 3/4' WEEP AT EACH SCREEN RETAIN 1.070 I •055 .812 .687 V- VENT SIDE RAIL .055 1.2512 2.104 .812 �1.179 -i IIFF----1.617 FRAME JAMB m1 / 7 toy"-U Z q N 0 hw Qa `46 05. a a N � paan� 0aoiz� a�Z� LLz$ m L1 Q w 17 J 3 3 � V � z o �$ z N �o"> O �, •p a o -01 C_ LZN L I 0 0 o �i3 am� Z N O 0 p M a E .. ��1y2 `�� ��: �1GENSF •• o i air No.61223 = a a Q '•, 8T Cf9� drawing no. Sealed: 10/13/2020 W15-60 FL #21857 ��i1�f11111111\\ sheet 5 of 5 ,