HomeMy WebLinkAboutBuilding PlansCOND. UNIT SLAB _U.#3 W/P GFCI TON SERVICE OUTLET WAREHOUSE #3 r_______---. f UNITS MUST COMPLY WITH AUXILIARY AND SECONDARY DRAIN SYSTEMS IN ADDITION TO THE REQUIREMENTS OF SECTION 307.2.1. REFER TO F.B.C.M. 2020 CHAPTER 3, SECTION 307.2.3 FRESH AIR: THE A/C UNIT MUST BE EQUIPPED WITH AN EASILY ACCESSIBLE AUTOMATIC SHUTOFF DAMPER WHEN THE UNIT IS NOT IN USE. 21 P CFI 24, X 2- ---A— WAY_ I I i I I i I I I I I I I I I I NOTE: T-STAY LOCATION SHALL COMPLY WITH 2O20 F.B.C. -ACCESSIBILITY CODE 308.2 -FORWARD &SIDE REACH. 15 CFM I 4X24 WAY----L.---- ---- I I I I I I ! I o I CONDENSATE DRAINS TO DISCHARGE IN APPROVED AREAS AS PER SECTION 307 OF THE 2020 F.B.C.M COND.. 'UNIT SLAB COND. UNIT SLAB W/P GFCI C.UM_N77 2 ItaIT-g-u- 1 SERVICE OUTLET 2 F---\ / II 2.5TON SERVICE/OUTLET I I I N112X12 4 WAY--------------------�---- 5„ I I I I I I I e I I � I T-- fAUT 24-2IW0 CFM I--- — — -- XH.FANX s 1 X 12 24 19" 4 4 WA____ REN THRU I WAL I ! I I -----I ' I I I _____ FM I ----- ----- ------- J------- ---- ---- I I I I I I I I I I I I I I I I I I I I I I I I ----� -------------_F-----------------7 ---------T --®— I ! 4 CFM I I I I I I I I 1 4 X "4 24: X 24 g" i 24 X 24 g" WA ----- j ___4 WAY ---_ I 4 WAY ° I I B I I e I I I I I I I I I I MOTORIZED ACCESSIBLE OUTSIDE ,DAMPER I I I I --- _--- ---I _ _ _ _ I I F ICE 4 I—— 12 I I q2 !SO FT f-1 i� ---t---------- I ----- ----I--------- — 1�----------H---- I I I I' I I' MOTORIZED & ACCESSIBLE OUTSIDE AIR DAMPER CONDENSATE DRAINS TO DISCHARGE IN APPROVED AREAS AS PER SECTION 307 OF' THE 2020 F.B.C.M. r-__________________________— I I UNITS MUST COMPLY WITH AUXILIARY AND ':SECONDARY DRAIN SYSTEMS IN ADDITION TO THE REQUIREMENTS OF SECTION 307.2.1. REFER TO F.B.C.M. 2020 CHAPTER 3, SECTION 307.2.3 FRESH AIR: THE A/C UNIT MUST BE EQUIPPED WITH AN EASILY ACCESSIBLE AUTOMATIC SHUTOFF DAMPER WHEN THE UNIT IS NOT IN USE. EN jSUPPLY DIFFUSERS ®—RETURN AIR DIFFUSER (D—T—STAT. SD SMOKE DETECTOR TEST STAnoN TS AUDIBLE & VISUAL ALARM IQ_ RETURN AIR DIFF )TER OPPOSED BLADE 104MPER ®� SUPPLY DIFFUSER OPPOSED BLADE DAMPER PERFORATED STAINLESS —STEEL (S.S) GRILIJ:S F/b —FIRE DAMPER IN (DUCT F::]]—BALANCE DAMPED IN SUPPLY —BALANCE DAMPER, O/A f WITH FIRE/SMOKENI?AIM EREFk SUPPLY TRUNK RETURN TRUNK NORTH ARROW i 61 CFM 12 X 12 ° 4 WAY — — — — — — — —------- ------------r---- NAREHOU5Ea #1 5" I-iC BATS 2 -- T ---- T— i AT 70 CFM I --- — =— 215 CrM _._. XH.FAN 1� X 12 d g"I 24 X 124 ._ � 4 AMA RETUR° N THRUIWAL ! I I I ----- ---- -----------..- _ _ ---- I I I I tl I I I I I ! I I I I ! I f I I 1 i I I I 24: X 24 g" ; 24 X 24 --- 4— AY ---- --- �— 4 WA -- ° ! I ! 6 I I 1 i I I I I i p i I I I UNITS MUST COMPLY WITH AUXILIARY AND SECONDARY DRAIN SYSTEMS IN ADDITION TO THE REQUIREMENTS OF SECTION 307.2.1. REFER TO F.B.C.M 2020 CHAPTER 3, SECTION 307.2-3 TTF 3 ) UNITS PLAN SCALE: 114u—= Io-0n FRESH AIR: THE A/C UNIT MUST BE EQUIPPED WITH AN EASILY ACCESSIBLE AUTOMATIC SHUTOFF DAMPER WHEN THE UNIT IS NOT IN USE. MOTORIZED & ACCESSIBLE OUTSIDE AIR DAMPER cn U LL_ ^ Lij r Q 0 � � O cf) O (o _ 9 L CDCD � I L(� Q 0—.4 J n— ® W O r U U W Q) v N0 a) c- ULi � @) �co Q i N 00 r <L_ L LLJ z W W CD _.J LIJ' ' I r�� ll J fur L� Q W W W �r D W � ry Q a Q 0 LL_ NJ STAN I LD: PRELIM: PRELIM 2: CONST ROCS: 07 20 2021 BLDG DEPT: BLDG DEPT: BLDG DEPT. AS—BUILTS: SCALE: 1 /4" : V--0" SHEET REVIEtIfED "' ^^hit CODE ■ , NC�E FILE OCC i It, d b-1/ Z_ RM CLIP 1" 14 E ETAL 3/4 1 /8" ;21 GENERAL HVAC NOTES ARE IN COMPLIANCE WITH 2O20 F.B.C.M. AND F.B.C.EC [CET COMMERCIAL 1❑ AN AIR DISTRIBUTION SYSTEM SHALL BE DESIGNED AND INSTALLED TO TO SUPPLY THE REOUREO DISTRIBUTION OF AIR. E INSTALLATION OF AN AIR DISTRIBUTION SYSTEM SHALL NOT AFFECT THE FIRE PROTECTION REQUIREMENTS SPECIFIED N THE F.B.C.B. 2020. DUCTS SHALL BE CONSTRUCTED. BRACED, REINFORCED AND INSTALLED TO PROVIDE STRUCTURAL STRENGTH AND DURABILITY. REFER TO THE F.B.C.UM. CHAPTER S. SECTION 603 - DUCT CONSTRUCTION & INSTALLATION. A LEVEL WNORIONG SPACE NOT LESS THAN 30 INCHES DEEP AND 30 INCHES 1110E SHALL BE PROVIDED N FRONT OF THE CONTROL SIDE TO SERVICE THE APPUANCF- REFER TO F.B.GM. 202D CHAPTER 3. SECTION WEI - ACCESS & SERVICE ® ALL DUCT SYSTEMS INSTALLED N 'NON-CON01TIONED" AREAS SHALL BE CONSTRUCTED WITH APPROVED MATERIAL AND OF A VALUE OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED NTH GLASS FAB ✓E MASTIC 'OR" APPROVED TAPES THAT EXTEND NOT LESS THAN 1 INCH AND LABELED N ACCORDANCE WITH THE UL-181A. PART 1 FOR DUCT BOARD OR UL 1818. PART 1 FOR FLEiL ALL THRU-WALL, FLOOR ML CEILING PENETRATIONS INTO THE DUCT SECTION SHALL CONTAIN A BRANCH DUCT FABRICATED OF RIGID FIBROUS GLASS DUCT BOARD OR RIGID METAL AND IS SEALED TO BOTH DUCT SECTION AND GRILLE SIDE WALL SURFACE. THE BRANCH DUCT SHALL BE FABRICATED AND ATTACHED N AQCUMANCE WITH 2O20 F.B.C.M. CHAPTER 6. SECTION 503 AND 604 RESPECTIVE TO THE DUCT TAPE USED. 3. All DUCT TRUNK 90 DEGREE TURNS OR TEES, SHALL HAVE TURNING VANES. 3 PIECE OR 46 DEGREE TURNS CAN BE N PLACE OF 90 DECREE TURNS AND 00 NOT NEED TURNING VANES. . EQUIPMENT AND APPUANCES INSTAII O AT GRADE LEVEL SHALL BE SUPPORTED ON A LEVEL_ CONCRETE SLAB OR ER APPROVED MATERIAL. EXTENDING NOT LESS THAN 3 INCHES (75MM) ABOVE ADJOINING GRADE OR SHALL BE SUSPENDED NOT LESS THAN 6 INCHES (152MM) ABOVE ADJOINING GLADE SUCH S "MT SHALL BE IN ACCORDANCE THE MANUFACIIJIE INSTAUJLTIONI INSTRUCTIONS. AS PER 2020 F.B.C.M. CHAPTER 3, SECTION 304,10 EACH ZONE SHALL BE PROVIDED WITH THERMOSTATIC SETBACK CONTROLS THAT ARE CONTROLLED BY EITHER TIME CK OR A PR06RAMMABLF CONTROL SYSTEM. AS PER 202D F.Mt[E0 0403.2.4.1 AND C403.2.4.2 CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT A WRITTEN BALANCE REPORT BE PROVIDED TO DOER OR GNATED REPRESENTATIVE. AIR DISTRIBUTION SYSTEMS SMALL BE TESTED, ADJUSTED, AND BALANCED BY A LICENSED gNETR OF THIS STATE DR A THIRD PARTY COMPANY HOLDING A CURRENT TEST & BALANCE CERTIFICATION. AIR BALANCING, SECTION 4013.1.5 - THE VENTILATION AIR DISTRIBUTION SYSTEM SHALL BE PROVIDED WITH MEANS lll��q ADJUST THE SYSTEM To ACHIEVE 140T LESS THAN THE MINIMUM VENTILATION AIRFLOW RATE AS REQUIRED BY SECTIONS 403.3 AND 403.3.1.2. VEN flLATION SYSTEMS SHALL BE BALANCED BY AN APPROVED METHOD. SUCH BALANCING SHALL VERIFY THAT THE VENTILATION SYSTEM IS CAPABLE OF SUPPLYING AND EXHAUSTING THE AIRFLOW RATES REQUIRED BY MCTIDNS 403.3 AND 403.3.1.2 SMOKE DETECTORS APPROVED FOR AIR DUCT USE SHALL BE INSTALLED ON THE SUPPLY SIDE OF AIR -HANDLING SYSTEMS AS REQUIRED BY NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR CONDITIONING AND VENTILATING SYSTEMS. SMOKE DETECTORS LISTED FOR USE IN AIR DISTRIBUTION SYSTEMS SHALL BE LOCATED DOWNSTREAM OF THE AIR FILTERS AND AHEAD OF ANY BRANCH CONNECTIONS IN THE AIR SUPPLY SYSTEMS HAVING A CAPACITY GREATER THAN 2000 CFM. THE DUCT SMOKE DETECTDRS SHALL EIE CONNECTED TO A FIRE ALAIN SYSTEM WHERE A FIRE ALARM SYSTEM IS REQURED BY THE TLARIDA FIRE PREVENTION COOS. THE ACTUATION OF A DUCT SMOKE DETECTOR SHALL ACTIVATE A VISIBLE AND AUDIBLE SUPERVISORY SIGNAL AT A CDNSTANTLY ATTENDED LOCATION. IN FACILITIES THAT ARE REQUIRED TO BE MONITORED BY A SUPERVISING STATION, DUCT SMOKE DETECTORS SHALL REPORT ONLY AS A SUP VISORY SIGNAL. NOT AS A FIRE NAM. REFER TO F.B.C.M. CHAPTER 8. SECTION 608.2.1 THROUGH 608.4.1. WHERE MULTIPLE AIR -HANDLING SYSTEMS SHARE A COMMON SUPPLY WITH A COMBINED DESIGN CAPACITY GREATER THAN 2000 CFM. EACH SUPPLY MR SYSTEM SHALL BE PROVIDED WITH SMOKE DETECTORS IN ACCORDANCE WITH SECTION 606.2.1. SMOKE DETECTORS REQUIRED BY THIS SECTION SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 72 THE REQUIRED SMOKE DETECTORS SHALL BE INSTALLED TO MONITOR THE ENTIRE AIRFLOW CONVEYED BY THE SYSTEM. SMOKE DETECTORS SHALL NOT BE REQUIRED FOR FAN UNITS WHOSE SOLE FUNCTION IS TO REMOVE AIR FROM THE INSIDE OF THE BUILDING TO THE OUTSIDE OF THE BUILDING. ACCESS SHALL BE PROVIDED TO SMOKE DETECTORS FOR INSPECTION AND MAINTENANCE. REFER TO RELC.M. 2D20 606.3 - INSTALLATION 9. FIRE DAMPERS, SMOKE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND CEILING RADIATION DAMPERS LOCATED WITHIN AIR DSTMBU71CN AND SMOKE CONTROL SYSTEMS SHALL BE INSTALLED N ACCORDANCE WITH THE REQUIREMENTS OF THIS SECTION. AND THE MANUFACTURER'S INSTRUCTIONS AND LISTING. REFER TO F.B.C.M. 2020 CHAPTER 607.2 - INSTALLATION DAMPERS SHALL BE LISTED AND LABELED IN AC3COWANCE WITH THE STANDARDS N THE SECTION. FIRE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF UL 555. ONLY FIRE DAMPERS AND CEILING RADIATION DAMPERS LIBELED FOR USE IN DYNAMIC SYSTEMS SHALL BE INSTALLED IN HEATING, VENTILATING AND AIR-CONDITIONING SYSTEMS DESIGNED TO OPERATE WITH FANS ON DURING A FIRE. SMOKE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF UL 5551 COMBINATION FIWIMOKE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF BOTH UL 555 AND UL 5555. CEILING RADIATION DAMPERS SHANLIL COMPLY WITH THE REQUIREMENTS IF UL 555C OR SHALL BE TESTED AS PART A FIRE -RESISTANCE -RATED FLOOR CEILING OR ROOF WLING ASSEMBLY IN ACCORDANCE WITH ASTM E119 OR UL 263. OMP CORRIDOR DAMPERS SHALL COMPLY WITH REQUIREMIEINTS 0� BOTH UL 555 AND iUL 555S. CORRIDOR DAMPERS SHALL. DEMONSTRATE ACCEPTABLE a-DSURE PERFORMANCE WHEN SUBJECTED TO 150 FEET PER MINUTE (0.78 MPS) VELOCITY ACROSS THE FACE OF THE DAMPER USING THE UL 565 FIRE EXPOSURE TEST. REFER TO F.B.C.M. 2020 CHAPTER 5 SECTION 607.3.1 - DAMPER TESTING ALL DAMPERS LOCATED AT CEILING OR WALL PENETRATIONS MUST HAVE AN ACCESS DOOR TO RESET DAMPER UNLESS THE DAMPER IS IN THE DIFFUSER. THAN IT CAN BE RESET THROUGH THE DIFFUSER. WHERE A SMOKE DAMPER IS INSTALLED WITHIN A DUCT. A SMOKE DETECTOR SHALL BE INSTALLED INSIDE THE DUCT OR OUTSIDE THE DUCT WITH SAMPLING TUBES PROTRUDING INTO THE DUCT. THE DETECTOR OR TUBES WITHIN THE DUCT SHALL BE WITHIN 5 FEET OF THE DAMPER. AIR OUTLETS AND INLETS SHALL. NOT BE LOCATED BETWEEN THE DETECTOR OR TUBES AND THE DAMPER. F.ELC.M 2020 607.3.3.2 DAMPER ACTUATION SHALL BE IN ACCORDANCE WITH SECTIONS 607.3.3.1 THROUGH 607,13.4 AS APPLICABLE. CORRIDOR DAMPER ACTUATION SHALL 13E IN ACCORDANCE WITH SECTIONS 607.3.;L7 AND 607.3.3.2 ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO F.B.C.M. ZD20 CHAPTER S. 1. FRESH AR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT OUTLET, OR ITARY SEWER VENT OUTLET. ALL OUTDOOR INTAKES AND EXHAUSTS SHALL HAVE AUTOMATIC OR GRAVITY DAMPERS T CASE WHEN VENTILATION IS NOT OPERATING. F.B.GM. 2020. SECTION 401:1• HZJ ALL EXHAUST DUCTS. SHALL BE CONSTRUCTED OF METAL AND COMPLY WITH F.B.CJM. 2020 CHAPTER S. SECTION 501.5 ffM CONDENSATE FROM ALL ODOUNG COILS AND EVAPORATORS SHALL BE CONVEYED FROM THE DRAIN PAN OUTLET TO AN ROVED PLACE OF DISPOSAL, SUCH PIPING SHALL MAINTAIN A MINIMUM HORIZONTAL SLOPE IN THE DIRECTION OF DISCHARGE OF NOT LESS THAN ONE -EIGHTH UNIT VERTICAL IN 12 UNITS HORIZONTAL (I -PERCENT SLOP). CONDENSATE SHALL NOT DISCHARGE INTO ANY STREET, ALLEY OR OTHER AREA AS TO CAUSE A NUISANCE. IN ADDITION TO THE REQUIREMENTS OF SECTION 307.2.1, WHERE DAMAGE TO ANY BUILDING COMPONENTS COULD OCCUR AS A RESULT OF OVERFLOW FROM THE EQUIPMENT PRIMARY CONDENSATE REMOVAL SYSTEM, AN AUXILIARY PROTECTION METHOD SHALL BE PROVIDED FOR EACH COCUNG COIL OR FUEL -FIRED APPLIANCE THAT PRODUCES CONDENSATE. REFER TO F.B.C.M 20M CHAPTER 3. SECTION 3I 7.2.3 #1 THRU #4. CONDENSATE DRAIN SYSTEMS SHALL BIE DESIGNED, CONSTRUCTED AND INSTALLED N ACCORDANCE WITH F.B.0 M. 2017 CHAPTER 3, SECTIONS 307.2-1 THROUGH 307.2 b CONDENSATE WASTE AND DRAIN LINE SIZE SHALL BE NOT LESS THAN 3/4" INTERNAL DIAMETER AND SHALL NOT DECREASE IN SIZE FROM THE DRAIN PAN CONNECTION TO THE PLACE OF CONDENSATE DISPOSAL.. WFIERE THE DRAM PIPES FROM ONE UNIT ARE MANIFOLDS) TOGETHER FOR CONDENSATE DRAINAGE, THE PIPE OR TUBING SHALL BE SIZED IN ACCORDANCE WTH F.B.C.M. 2020 CHAPTER 3, TABLE 307.2.2 ALL HORIZONTAL PRIMARY DRAIN LINES WITHIN UNCONDITIONED AREAS SHALL BE INSULATED DUCTLESS MINI -SPLIT EQUIPMENT THAT PRODUCES CONDENSATE SHALL BE PROVIDED WITH AN INLINE CHECK VALVE LOCATED IN THE DRAIN LINE OR A TRAMP. REFER TO F.B.CM. 2020 CHAPTER 3. SECTION 307.2.4.1 CONDENSATE PUMPS LOCATED N UNINHABITABLE SPACES. SUCH AS ATTICS AND CRAWL SPACES, SHALL BE CONNECTED TO THE APPLIANCE OR EQUIPMENT SERVED SUCH THAT WHEN THE PUMP FAILS, THE APPLIANCE OR EQUIPMENT WILL BE ENNENTED FORM OPERATING. PUMPS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURERS' INSTRUCTIONS. PAJ BATHROOMS CDNTMNNG BATHTUBS, SHOtlA:RS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE MECHANICALLY VENTILATED. "EXCEPTION' RESIDENTIAL BATHROOMS HAVING NO LESS THAN 4 PERCENT OF FLOOR SPACE. F.B.C.M. ZD20 CHAPTER 4, SECTION 402.2 E-51 ALL AIR DISTRIBUTION cOMRCNENT3 WILL BE INSTALLED IN ACCORDANCE TO 202D F.B.C.M. AND F.E.C.C:. M IF HVAC EQUIPMENT O-DI R THAN SPECIFIED BY DESIGNER IS SUBSTITUTED, IT'S CAPABILITIES OF BTU REMOVAL BE EQUAL TO THE EQUIPMENT SPECIFIED BY THE HVAC DESIGNER. DA THE HVAC DESIGNER WILL, NOT BE IRESPONSIBLE FOR ANY SYSTEM NOT INSTALLED ACCORDING TO PLANS. � 14 GAUGE ----GALVANIZED 6" STEEL "NOTE: 4 CLIPS PER CONDENSING UNIT". 6 EACH 3/16" X 3/8" SHEET METAL SCREWS IN THE SLOTTED HOLES ON RM CLIP 1 EACH 1/4" X 3 1/4" LONG TAPCON CONCRETE SCREW THROUGH RM CLIP INTO CONCRETE SLAB RM CLIPS ARE G-90 RATED FOR CORRISION/WIND RESISTANCE, 2020 ASCE 10-16, 170 MPH WINDS CONDENSING UNIT MOUNTING DETAIL SEE GENERAL HVAC NOTES: RES. ][IJRU-WALL RETURN AIR HANDLING UNIT N.T.S. CONDITION AREA ATTIC OR UNCONDITIONED AREA ALL SUPPLY AND RETURNS MUST BE MIN. R-6, 1 1/2" FIBERGLASS DUCT OR FLEX IN ATTIC OR UNCOND. SPACE IN CONDITION SPACE MIN. R-4, 1 INCH. Cv=1:31r%1n P•PAI I Z] Z>SUPPLY DIFFUSERS E]-RET RN AIR DIFFUSER To- T-STAT, SUI SMOKE DETECTOR TEST STATION TS AUDIBLE & MSUAL ALARM RETURN .AIR DIFFUSER OPPOSED BLADE DAMPER SUPPLY DIFFUSERS OPPOSED BLADE DAMPER Dm PERFORATE STAINLESS STEEL (S.S) GRILLES F,;;-FIRE DAMPER IN DUCT I; ]-BALANCE DAMPER IN SUPPLY ----BALANCE DAMPER O/A WITH FIRE/SMOKENDAMPEREIR SUPPLY TRUNK - RETURN TRUNK BATHROOM EXHAUST FAN SCHEDULE FAN# MFG EXHAUST FAN TYPE CFM VOLTS PART# DUCT DIA. 1 BROAN CEILING EXHAUST FAN 70 120 XB80L 4 INCHES 2 BROAN CEILING EXHAUST FAN 70 120 XB80L 4 INCHES 3 BROAN CEILING EXHAUST FAN 70 120 X880L 4 INCHES 4 BROAN CEILING EXHAUST FAN 70 120 XB80L 4 INCHES 5 BROAN CEILING EXHAUST FAN 70 120 XB80L 4 INCHES 6 BROAN CEILING EXHAUST FAN 70 120 XB80L 4 INCHES 7 BROAN CEILING EXHAUST FAN 70 120 XB80L 4 INCHES 8 BROAN CEILING EXHAUST FAN 70 120 XB80L 4 INCHES CEILING EXHAUST FAN DETAIL 2020 F.B.C.M. 501.3 ROOF CURB ��Z' ROOF CAP ROOF CEILING/ROOF FLASHINGMIN. EXH. DUCT F., L EXHAUST FAN WALL CAP FLOOR W/ BACKDRAFT CEILING FAN ABOVE DAMPER - 7 rOR ROOF CEILING P� EXHAUST GRILLE DUCT EIAIHI3QQM EXHAUST FAN DETAIL - SIDEWALL DISCHARGE N.T.S. H .1�. A. C.EQUIPMENT SCHEDULE NOTE: ELECTRIC REQUIREMENT FOR EQUIPMENT TO BE FIELD VERIFIED BY ELECTICTIAN/MECHANICAL CONTRACTOR, A/C MFG- ,, OR EXISTING MODEL NO. EQUAL OR EXISTING SENSIBLE LATENT TOTAL-BTUH COOLING/HEATING SEER VOLTAGE RLAm M.C.A. I MOCP CFM 0/AI CFM O/A LINE UNIT WEIGHT 1 CARRIER #9193304 AHU: FB4CNF030L00 COND: CA14NA0300OG 20868 7332 2.5 TON 28200 17060 BTU/h 14 208/230 1 /60 18.1/20 _ 31.2/33.5 35/35 762 130 6" 122# 13.5 17.6 25 111 # 2 CARRIER #9192749 AHU: FB4CNF024LOO COND: CA14NA0240OG 16872 5928 2 TONS 22800 17060 BTU / h 14 208/230 1 /60 36.2/40 53.8/58.5 60/60 706 130 6" 117# 12.8 -- 16.8 25 110# 3 CARRIER # 9192749 AHU: FB4CNF024L00 COND: CA14NA02400C 16872 5928 2 TONS 22800 17060 BTU/h 14 208/230 / 1 /60 36.2/40 53.8/58.5 60/60 706 130 6" 117# 12.8 - 1.8 25 110# 4 CARRIER #9192749 AHU: FB4CNF024LOO COND: CA14NA02400G 16872 5928 2 TONS 22800 17060 BTU/h 14 208 230 / 1 /60 36.2/40 53.8/58.5 60/60 706 131^I 6" 117# 12.8 16.8 25 110# 5 CARRIER # 9192749 AHU: F134CNF024L00 COND: CA14NA0240OG 16872 5928 2 TONS 22800 17060 BTU h / 14 208 / 230 1 /60 36.2/40 53.8/58.5 60/60 706 130 6" 117# 12.8 16.88 25 110# 6 CARRIER #9192749 AHU: FB4CNF024LOO COND: CA14NA0240OG 16872 5928 2 TONS 22800 17060 BTU/h 14 208/230 1/60 36.2/40 53.8/'561.5 60/60 706 130 6PP 117# 12.8 16.8 25 110# 7 CARRIER #9192749 AHU: FB4CNF024LOO COND: CA14NA0240OG 16872 5928 2 TONS 22800 17060 BTU/h 14 208/230 1 60 36.2/40 53.8/58.5 60/160 706 130 6"/ 117# .. 128 168 25 110# 8 CARRIER #9192749 AHU: FB4CNFO24L00 COND: CA14NA0240OG 16872 5928 2 TONS 22800 17060 BTU/h 14 208/230 1 /60 36.2/40 53.8/58.5 60/60 706 130 6" 117# 12.8 16.8 25 11 O# AHU #01 - OUTSIDE AIR SCHEDULE j SPACE I OCCUPANTS CFM'S OPEN OFFICE SPACE .06 CFM X 437 SQ.FT. = 26 5 CFM X 3 OCC. = 15 CFM CFM 41 OUTSIDE AIR ADDITIONAL FRESH AIR NEEDED 89 TOTAL +130 AHU #02 - OUTSIDE AIR SCHEDULE SPACE OCCUPANTS CFM'S OPEN OFFICE SPACE .06 CFM X 437 SQ.FT. = 26 CFM 5 CFM X 3 OCC. = 15 CFM 41 OUTSIDE AIR ADDITIONAL FRESH AIR NEEDED 89 TOTAL +130 AHU #03 - OUTSIDE AIR SCHEDULE SPACE OCCUPANTS CFM'S OPEN OFFICE SPACE .06 CFM X 437 SQ,FT. = 26 CFM 5 CFM X 3 OCC. = 15 CFM 41 OUTSIDE AIR ADDIT10NAL FRESH AIR NEEDED 89 TOTAL +130 AHU #04 - OUTSIDE AIR SCHEDULE SPACE OCCUPANTS CFM'S OPEN OFFICE SPACE .06 CFM X 437 SQ.FT. = 26 CFM 5 CFM X 3 OCC. = 15 CFM 41 OUTSIDE AIR ADDITIONAL FRESH AIR NEEDED 89 TOTAL +130 AHU #03 - OUTSIDE AIR SCHEDULE SPACE OCCUPANTS I CFM'S OPEN OFFICE SPACE .06 CFM X 437 SQ.FT. = 26 CFM 5 CFM X 3 OCC. = 15 CFM 41 OUTSIDE AIR ADDITIONAL FRESH AIR NEEDED 89 TOTAL +130 AHU #06 - OUTSIDE AIR SCHEDULE - SPACE OCCUPANTS CFM'S OPEN OFFICE SPACE .06 CFM X 437 SQ.FT. = 26 CFM 5 CFM X 3 OCC, = 15 CFM 41 OUTSIDE AIR ADDITIONAL FRESH AIR NEEDED 89 1'OTAL +130 AHU #07 - OUTSIDE AIR SCHEDULE SPACE OCCUPANTS CFM'S OPEN OFFICE SPACE .06 CFM X 437 SQ.FT. = 26 CFM 5 CFM X 3 OCC. = 15 CFM 41 OUTSIDE AIR ADDITIONAL FRESH AIR NEEDED 89 TOTAL +130 AHU #08 - OUTSIDE AIR SCHEDULE SPACE OCCUPANTS CFM'S OPEN OFFICE SPACE .06 CFM X 437 SQ.FT. = 26 CFM 5 CFM X 3 OCC. = 15 CFM 41 OUTSIDE AIR ADDITIONAL FRESH AIR NEEDED 89 TOTAL +130 Paul Charet OUTSIDE AIR A'ti PER 2020 F.B.C.M. CHAPTER 4, SECTION 403.3 BALANCE AIR SCHEDULE POS / NEG SPACE CFM'S POSITIVE-AHU #01 OPEN OFFICE' SPACE -.A +130 POSITIVE-AHU #02 OPEN OFFICE SPACE +130 POSITIVE-AHU #03 OPEN OFFICE SPACE +130 POSITIVE-AHU #04 OPEN OFFICE SPACE +130 POSITIVE-AHU #05 OPEN OFFI11_,E SPACE +130 POSITIVE-AHU #06 OPEN OFFIIs'e SPACE +130 POSITIVE-AHU #07 OPEN OFFIIAIm SPACE +130 POSITIVE-AHU #08�OPEN OFFICE SP:ACI'-. +130 NEGATIVE BATHRCIOM EEXHAUST FANS -560 TOTAL BUILDING PRESSURE +480 NOTE: BUILDING PRESSURE I --'OR EACH BAY SHALL BE +60 CFM's i DUCTS MUST BE IN COMPUANCE WITH CHAPTER 0. 2020 F.&C.M. SECTIONS 003 1.4 604 uppan a IL MAX or Im"Qv[ P COLLAR BaiNN R-L I IfY FM Wa WON! RNI➢ P6R NTW Lm /� �-y ert FAx N ATTIC OR Iw aNlllaiR TACT w ATIW , uMO� ui g no IMII m aunn 1.5 NNI WE 000 .;.Nper tNaN aBNVAanr mAL WFUM i ai Bb [vm YAM& Na PM= Fin Mw TMT a N � \Nl " cmff= TFm BT mm me Lm TBMR P N` Nara NZ am" LNOI wvA NMLL ran T1 NNT wow --I AL ow- NT. ALL m= 716ML R ffi®N ACC M= 8N LL IM MWAL Na- off.All NOT aINALL W UallD AM LAaGID AS OIAaa O Ail CLAN SWL BE A IT OF Ma NFAAIM N UNME NN WAS FRESH AIR INTAKES SHALL BE LOCATED NOT LESS THAN 10 FEET FROM ANY GREASE VENT OR SANITARY SEWER VENT OUTLET - REFER TO HVAC NOT #11 NOTE: T-STAT LOCATION SHALL COMPLY WITH 2O20 F.B.C. - ACCESSIBILITY CODE 308.2 - FORWARD do SIDE REACH. IN,_INE SUPPLY BRANCH SUPPLY TRUNK i SUPPLY BRANCHES PERPENDICULAR NOTE: ,k---AIR FLOW SUPPLY TRUNK MUST .- NOTE: EXTEND A MIN OF 1' \ ALL SUPPLY & RETURN BEYOND LAST SUPPLY BRANCH BRANCHES MUST HAVE NOTE: \MANUAL AIR DAMPERS ALL. SUPPLY BRANCHES "MUST"' HAVE A MIN. OF 2FT. DISTANCE BETWEEN EACH COLLAR WHEN APPLICABLE, EXCEPT BRANCHES STRAIGHT PERPENDICULAR ACROSS FROM 'EACH OTHER. REVIEWED FOR CODE - ,oftro KIC / �,, , 7, PROJECT A 43461221 C THIS HVAC SYSTEM AS DESIGNED IS IN COMPLIANCE WITH 2O20 F.B.C.M. AND THE 2020 F.B.C.EC (CE1 COMMERCIAL EFFICIENT ENERGY SERVICES, INC. ROY ABOOD STATE OF FLORIDA RATER TIP.O.ES. OXS 1316TOOT AL CAM A3 FL. 32702 PHONE - 352-069-9040 FAX - 352-669-7526 VITWO- AR 0016279 hare e • V J 0 0 Z LL_ Lij _ qt 0 0 U o J F-P-I ® V) 0 _ Ln U z Ln d..e Q a_ LI_I w Fry LLB _ ~ Q) ~ U DO -H j Ld � C3 U N (� F d- < N N � 0 Qo C[ < N 00 LLJ G I,] W L- LL_) cf/ < Li LLJ Lj a 0- Q O 0 J 0 N CIS 0 L - N PRELIM: PRELIM 2: PRELIM FINAL: CONST DOGS: 07/20/2021 BUILTS: SCALE: 1 L4" : 1'- SHEET CQ)6q-6t06 ELECTRICAL SNBOLS if DUPLEX RECEPTACLE AT 12" A.F.F. SWITCH SINGLE POLE Y TELEVISION JACK PREWIRED SMOKE DETECTOR rE ELECTRICAL METER OB DUPLEXRECEPTACLE IAT BASE *3 SWITC44 T44REE WAY DEDICATED RECEPT. AT 12" A.F-1�220 V) EDJ SWITCH DISCONNECT BREAKER PANEL OC DUPLEX RECEPTACLE AT 5" ABV. COUNTER t4 SWITCH FOUR WAY T HVAC THERMC r-E)TAT PADDLE FAN W/ OR W/O LIGHT EXHAUST FAN (D DUPLEXRECEPTACLE FLUSH IN FLOOR R SWITCH RHEOSTAT Q INTERCOM AT 60" A.F.F. LED 2 X 4 LIGHT FIXTURE EXHAUST /LIGHT FAN 061 DUPLEXRECEPTACLE GROUND FAULT $D SWITCH DIMMER TELEPHONE OUTLET AT 12" A.F.F_ LED LIGHT FIXTURE CLG. MNTED. :)Fq LV DOOR RELEASE TTff DUPLEXRECEPTACLE TOP REG. SWITCHED SWITCH KEYED TELEPHONES OUTLET FLUSH IN FLOOR LED LIGHT FIXTURE WALL. NNT D. VOLUME CONTROL 11 ifWP DUPLEXRECEPTACLE WATERPROOF T SECURITY KEYPAD SPEAKER IN CLG. r > 4 11 LED HI HAT CLG. MOUNTED QUADRUPLEX RECEPTICAL Our- DUPLEXRECEPTACLE UNDER COUNTER ❑JUNCTION BOX SECURII-Y LIGHTS HI HAT VAPOR PROOF LED LIGHT - MNTD. UNDER CAB. PUSH BUTTON DOOR BELL J_ TYPE. (1) SQUARE D 0 EQUAL SERVICE: 120/208V, 1 -PH, 3W, MOUNTING: SURFACE POLES: 24 HOUSE PANEL MAIN BUS: 100 NEUTRAL: 100 FEEDER SIZE 1.5" MAINS: 3#3 1 #6 A.I.C. 22K SERIES KVA TRIP POLE CON- DUIT WIRE REMARKS CKT NO. CKT NO. REMARKS WIRE CON- DUIT TRIP POLE KVA 1.5 20-1 1/2 12 PARKING LOT LTG 1 A 2 PARKING LOT LTG 12 1/2 20-1 1.5 1.5 20-1 1/2" 12 GFI OUTLETS 3 B 4 SIGN 3#6 1#10 1" 30-2 1.5 1.5 20-1 1/2 12 SECURITY LTG 5 C 6 7 A 8 IRRIGATION PUMP 12 1/2 20-1 1.5 9 13 10 11 C 12 13 A 14 15 B 16 17 C 18 19 A 20 1 21 B 22 23 C 24 41 C 42 4.5 J2IAL_r&NNEQIED_LQAD 9 DEMANDLOAD_VA FIRST 1 OK 10.0 0 125% KVA 11-25 46.8 AMPS 4.5 TYPE: (8) SQUARE D 0 EQUAL MAIN BUS: 200 SERVICE: 120/208V, 3-PH, 4W, NEUTRAL: 200 MOUNTING: SURFACE FEEDER SIZE 2" PANEL UNITS 1-8 MAINS: M.L.O. POLES: 42 A.I.C. 22K SERIES KVA TRIP 7��'P P. POLE CON- CON - WIRE REMARKS CKT-1 NO. CKT. NO. REMARKS WIRE CON- DUIT TRIP POLE KVA 5.0 60-3 3/4 8 A/C #1A CU 1 1 A 2 A/C #1A AHU 8 3/4 30-3 5.0 3 8 4 1.0 20-1 1/2 12 OFFICE OUTLETS 7 A 8 WATER HEATER 12 3/4 20-21 4.2 1.5 20-1 1/2 12 WAREHOUSE LIGHTS 9 B 10 1.5 20-1 1/2 12 WAREHOUSE OUTLETS 11 C 12 WAREHOUSE 220 10 V4 20-2 2.0 1.5 20-1 1/2" 12 GF1 OUTLETS 13 A 14 1.5 20-1 1/2" 12 BATH LTG/FAN 15 B 16 BATH GR 12 1/2 20-1 1.0 1.5 20-1 1/2* 12 WF 17 C 18 EMERGANCY LTG 12 1/2 20-1 1.0 1.0 20-1 1/2 12 OFFICE OUTLETS 19 A 20 ALARM 12 11/2 20-1 1.0 1.5 20-1 1/2 - 12 WAREHOUSE EXHAUST 21 B 22 EXTERIOR LTG 12 11/2 20-1 1.0 1.0 20-1 1/2 12 OFFICE LTG 23 C 24 25 A 26 27 B 28 29 C 30 31 A 32 33 B 34 35 C 3C 37 A 38 39 B 41) 42 15.5 31.5 16.0 DEMANDLOADAYA FIRST 1OK 10.0 0 1005E 10.0 AC 5.0 )0 100% 5.0 BALANCE 14.5 )0 65% 9.42 24.42 101 TOTAL AMPS & SIMPLEX CONVENIENCE RECEPTACLE WT44 GROUND DUPLEX CONVENIENCE RECEPTACLE WTH GROUND DENOTES HEIGHT A.F.F., IF OTHER THAN STD.) GFI/GFCI DENOTES GROUND FAULT CIRCUIT INTERRUPTER) (WP DENOTES WEATHER PROOF) DUPLEX CONVENIENCE RECEPTACLE WT14 GROUND PROVIDE SEPARATE SURGE PROTECTED CIRCUIT QUADRUPLEX CONVENIENCE RECEPTACLE WT14 GROUND SWITCHED DUPLEX CONVENIENCE RECEPTACLE WITH GROUND, SWITCHED BOTH SIDES SWITCHED DUPLEX CONVENIENCE RECEPTACLE WITH GROUND, SWITCHED ONE SIDE 220 RECEPTACLE W/ ISOLATED GROUND MOUNTED AT STANDARD (36") HEIGHT Fj] FLOOR MOUNTED IN OUTLET, PHONE OUTLET, RECEPTACLE INFORMATION MANAGEMENT OUTLET(DATA/TELr:COMMUNIr-ATIONS/ COMMUNICATIONS/TELEPHONE), PROVIDE 4x4 BOX, FACEPLATE, 3/4" CONDUIT TO MDF, IDF, OR ATTIC (SEE SPECS) 4 PULL STRING $ SINGLE POLE SWITCH AT STANDARD HEIGHT D $ DINNER SWITCH W/ BUILT-IN OFF -ON SWITCH 3 $ THREE HAY SWITCH AT STANDARD HEIGHT FM--d MOTION SENSOR TELEPHONE OUTLET, PROVIDE 44 BOX, FACEPLATE, 314" CONDUIT TO ATTIC, * PULL STRING TO TBB. LED 441 BAY TYPE LIGHTING TBS BY OWNER LED HIGH HATS 7V 580 SMOKE/CARBON MONOXIDE COMBO EXHAUST FAN LIFE". SAFETY EQUIPMENT FDCTLIRE RrFrrICN 7 )"LL YkX)NT'ED BATTERY MP EKED EMERGENCY LIQW FIXTURE Arr;4 DOUBLE L"T5 lXC IIW-L OR CMILIW IMITED EMERGENCY EMT SIGN FACE SH" WITH DIRMTKNAL ARROW FIRE MMW4JI5HER ICI FEC FIRE. E)MNr.UIWM AND CABIWT 4 RUNS 3" COND TYP BAY 1-8 4-350 CU 12-15-21 4 RUNS 4" COND NIPPLES W/ Main disc: 4-350 CU 1200A, 3 pole 1-#2 Cu GIRD 41 KEY TAP (2) 12" X 12" X 15" 120/208v fused GUTTER NEMA 3R W/ NEUTRAL BAR & �IJI '2/1 1 L #6 GIRD BAR 15T CON �4 1� #3/D 200,000 AIC #6 4 METER 2' COMI. 2­-P 250V (1) 1200A 250V 5 JAWS 0 0 METER slow blow fuses 1-1 OU SE 2-P250V E METER 02/0 2" c 4) (4) 3" Meyers R� #6 --XISTG 1 Hubs 100 1.5" COND. � r A OOA 2/RCN I). rr 1120 20� 40 120/ 40 2 .3 P 200 AhP250V SLOW BLOW FUSES 2 EACH PANEL #4 TO CW PIPE BUILDG TO CW PIPE BUILD� 3/4" X10' GIRD RD 3/4- X10' GIRD RD I -FGROUND r 3/0 IN 3/4"C TO 2-3/4" X10' GRID RD TO CWP AND BUILDING STEEL FAULT CURRENT SUMMARY EST. AVAILABLE FAULT CURRENT AT FPL XFMR TO BE INSTALLED IS 41,700 A 3 PH SYMMETRICAL REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCI (i/z- z-- 49zilo �*_A LIC SE A 00 y Paul Char ate:,,..202 1®1 .......... 0:00:50 -05' MARK HUNLEY A.I.A. LICENSE AR 0099784 0 < 0 z LL_ Li ot� < 0 3: U Q-1 0 _J _j E-1 0 0 Q0 L0 CD Q0 Ln Ljj E 0 > 0 < -C Ld c I-_ cc U Li Ir) cc E­4 ry < In W N 0_ 0 CD < < 00 < 121� Li z __j I I I LL] 0 > < LL1 U u In, < Lj LLJ LLJ a_ r-- 0 < 0 0 0 STARTED: J !SPRELIM: IM. PRELIM 2: PRELIM FINAL: CONST DOCS: BLDG DEPT: 12-15-21 BLDG DEPT: BLDG DEPT: AS-BUILTS: CHECKED: SCALE: 1/4'* V-D" SHEET E