Loading...
HomeMy WebLinkAboutProduct Approval ( Siding )SCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Fads I Pul Contact Us I SCIS Site Map I Product Approval 1 USER: Public User Product Approval Menu > Product or Application Search > Application Us[ > Application Detail FL 3 Appllcatlon Type Code Version Applicatlon Status Comments Archived Product Manufacturer Addtess/Phone/Emall Authorlud Signature Technical Representative Address/Phone/Emall Quality Assurance Representative Address/Phone/Emall Category Subcategory Compliance Method Florida Englneer or Architect Name who developed the Evaluation Report Florida Ucense Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equlvalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved FL27502-R1 Revision 2020 Approved Elite Structures Inc. Elite Structures Inc po box 207 Adel, GA 31620 (229)896-7569 Janasht@elite-structures.com Jason Nash Janash@elite-structures.com Panel Wails Siding Evaluation Report from a Florida Registered Architect or a Ucensed Florida Professional Engineer r, Evaluation Report - Hardcopy Recelved Lucas A. TUmer PE-58201 Intertek Testing Services NA, Inc. - QA Entity 12/31/2023 Scott Walters, PE Validation Cheddist - Hardcopy Received EL27502Ji1 MI FvalRepgrt-IltcEBRYValLpdt Standard ASTM E1592 Yeat 2012 Method 1 Option D 02/09/2021 02/12/2021 02/22/2021 04/13/2021 FL* Model, Number or Name Description 27502.1 26 Ga. PBR Wall Panel 26 Ga. Non -Structural PER Wall Panel Llmitp of Use Installation InstruWons Approved for use In XVNL• No FL27502 R3 II Etlte-PBR.os Approved for use outside NVHZ. Yes Verified By: Lucas A. Turner PE R58201 Impact Resistant- No Created by Independent Third Party: Yes Design Pressure[ N/A Evaluation Reports other: Please see evaluation report and Installation Instructions for additional details FL27502 RI AE Evaliteport-Elite-PBR-Wall.pdf Back NSxL v` cantact-us:: 26DLBIaItSf<re nnad.Tallahassee-EI.32349P1ume: 8Sn487-1a29 The State of Florida Is an AA/EEO employer. Ca :: Edxacv�:_r•renumt :: Accesslbillt S tement :: Re(und.5tatement Under Florida law, emall addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an mall address which can be made available to the public. To determine 8 you are a licensee under Chapter 455, F.S., please dick hem. Product Approval Accepts: ®®®E4E Credit Card Safe URNER ENGINEERING & CONSULTING. INC. 2428 Old Natchez Trace Trail Camden, TN 38320 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report — Elite PBR Wall February 9, 2021 Product Description: PBR 26-Ga. 80ksi Steel Through -Fastened Non -Structural Wall Panel with AZ55 Galvalume Coating, Applied Over Purlins/Girts Manufacturer: Elite Structures Inc., 401 Old Quitman Rd., Adel, GA 31620 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61G20-3.005 (4). This product complies with the requirements of the 71h Edition (2020) Florida Building Code generally and section 1403.3 specifically, for use outside the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 2428 Old Natchez Trace Trl, Camden, TN 2) Approval drawing Elite-PBR, signed and sealed by Lucas A. Turner, RE 3) Test Report I1936.04-55044, from Intertek / Architectural Testing; Lithia Springs, GA a. Testing Performed: ASTM E1592-05(12) 4) Supplemental Calcs. to support Elite-PBR, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document Elite-PBR, with 7"-5"-7" pattern at panel ends and 12" o.c. across panel width into 16 Ga. 50ksi steel min. purlin/girt supports, by others. Structural supports and sheathing shall be designed by others to resist the applied loads. Through -panel fasteners into 16 Ga. steel supports shall be #12x1-1/4" Steelbinder drill point tip with integral EPDM gasket or approved equivalent. Overlap ribs shall be joined with #140/8" Steelbinder drill point tip with integral EPDM gasket or approved equivalent at 20" o.c. lengthwise. Limitations of Use: This product: • May be used up to 36" panel widths as indicated in Elite-PBR • Was structurally tested to -120 psf load; with factor of safety and panel/anchor analysis this results in an allowable Design Pressure of -60 psf at 48" support spacing • Is non -impact and may only be used over Approved walls in windbome debris regions • Was not tested for water infiltration resistance; weatherproofing of wall assembly is by others • May not be used in the High Velocity Hurricane Zone Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Elite Structures Inc. or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. ZZ .o No. 58209 A * 2/9/2021 t %�4° STATE OF •�►�� Lucas A. Turner P.E. i71�pOAT4,0 p!N,.,� `��� FL PE #58201 In A l ltI� PBR 26 GA, 80KSI STEEL NON-STRUCTURAL OVER 16 GA. 50 KSI MIN, PURLINS/GIRTS SCREW -DOWN PANEL FASTENER SPACING @ INTERMEDIATE SUPPORTS 3'-0' 12-14 x 1 1/4 STEELBINDER DRILLER W/WASHER OR APPROVED EQUIVALENT :n M SCREW -DOWN PANEL FASTENER SPACING @ PANEL ENDS 3'-0' 12-14 x l 1/4 STEELBINDER DRILLER W/WASHER OR APPROVED EQUIVALENT #14-14 x 7/8' STEELBINDER DRILLER W/WASHER OR APPROVED EQUIVALENT AT 20' MAX. O.C. 1/2' X 3/32' TAPE SEALER PIGTAIL TO ENDLAP SIDELAP 1/2' X 3/32' TAPE SEALER CONTINUOUS AT ENDLAP