Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, 5513 Winter Garden Underlayment
BCIS Home Log In User Registration Hot Topics Submit Surcharge Slats & Facts Publications Contact Us BCIS Site Map Links Search dbpr Product Approval k,k USER: Public User Product Aooroval Menu > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence _ Ac Referenced Standard and Year (of Standard) FL10626-R22 Revision 2020 Approved GAF 1 Campus Drive Parisppany, NJ 07054 (300)_766-3411 mstieh@gaf.com Robert Nieminen Ireith@nemoetc.com William Broussard 1 Campus Drive Parsippany, NJ 07054 (800)766-3411 TechnicalQuestionsGAF@gaf.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC 12/31/2024 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL10626_R22_CQI_2021_0I_COI_NIEMINEN. pdf Standard ASTM D1970 ASTM D4533 (tear) ASTM D4798 (weathering) ASTM D4869 (water transmission) Year 2015 2015 2011 2016 https://vaww.floridabuilding.org/pr/nr_app_dtl.aspx?param-wGE...Y5V%2boQY9nVE2RUHVOxKjvNQ3GJL9eiWUj2ta%2bEA%3d%3d 1113/22, 10:30 AM Page 1 of 2 NEMO Ietc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 fo (203) 262-9245 ENGINEER EVALUATE TEST CONSULT GAF Evaluation Report 01506.04.08-1122 1Campus Drive FL10626-R22 Parsippany, NJ 07054 Date of Issuance: 04/25/2008 (800) 766-3411 Revision 22: 06/09/2021 SCOPE: This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 7' Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: GAF Roof Underlayments for use in FBC non-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOletc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert •;''F Nieminen, P.E. on 06/09/2021. This does not serve as an ......... electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC CN�""�"JNEMO etc® ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the following sections of the 7t' Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. IN 6' STANDARDS:2. 1 a : Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1507.1.1, 1507.2.4, 1507.2.9.2 / Material standard ASTM D1970 2015 R905.1.1, R905.2.8.2 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) 1507.1.1 / R905.1.1 1507.3.3, R905.3.3 1507.11.2 TAS 110 Tear Strength . . Tensile strength Liquid water transmission Material standard Material standard Material standard Accelerated Weathering ASTM D4533 2015 ASTM D5035 2011 ASTM D4869 2016 ASTM D6757 2016 FRSA/TRI, Sixth Edition 2018 ASTM D6164 2011 ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date ERD (TST 6049) ASTM D1623 & FRSA/TRI (Slippage) G34150.08.11 11/14/2011 ERD (TST 6049) ASTM D6164 (GA) G40630.01.14-2B 01/07/2014 ERD (TST 6049) ASTM D6164 (GA) G46160.09.14-3A 09/09/2014 ERD (TST 6049) ASTM D1970 (GA) GAF-SC13285.03.17-3 03/01/2017 ERD (TST 6049) ASTM D1970 (GA) GAF-SC13285.03.17-4 03/01/2017 ERD (TST 6049) ASTM D1970 (GA) GAF-SC13285.03.17-1 03/08/2017 ERD (TST6049) ASTM D1970 (IN) GAF-SC16440.12.17 12/31/2017 Intertek(TST 1558) ASTM D4869 (Dadra, India) F8549.02-106-18 11/08/2016 NEMO (TST 6049) Physical Properties (ON) 4q-GAF-I9-SSM8B-03.A 05/13/2019 NEMO (TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/2020 NEMO (TST 6049) ASTM D4798, TAS 103 4j-GAF-20-SSUDL-02.A 03/15/2021 NEMO (TST6049) ASTM D4798 4j-FTS-2I-SSUDL-02.A 06/09/2021 PRI (TST 5878) ASTM D1970 (IN) GAF-324-02-01 11/30/2011 PRI (TST 5878) ASTM D226 (OK) GAF-339-02-01 03/13/2012 PRI (TST 5878) ASTM D4798 (NC) GAF-349-02-01 07/03/2012 PRI (TST 5878) Wind Uplift GAF-434-02-01 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-03 09/16/2013 PRI (TST 5878) Wind Uplift GAF-434-02-04 09/16/2013 PRI (TST 5878) ASTM D4533 (various) GAF-818-02-01 12/05/2017 PRI (TST 5878) ASTM D1970 (AL) MSA-047-02-01 04/11/2018 PRI(TST 5878) ASTM D4533 (LA) GAF-826-02-01 06/4/2018 PRI (TST 5878) ASTM D4533 (Dadra, India) GAF-847-02-01 06/4/2018 PRI (TST 5878) ASTM D4533 (Dadra, India) GAF-914-02-01 04/10/2019 PRI (TST 5878) ASTM D4533, D5035 (VA) 376T0012 07/15/2019 PRI (TST 5878) ASTM D4533 (Umerkui Kilvani, India) 376T0018 07/31/2019 PRI (TST 5878) ASTM D4533 (Parzai, India) 376T0018 07/31/2019 NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate ofAuthorizotion #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: 06/09/2021 Page 2 of 9 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 NNEMO I etc. Entity Examination Reference Date PRI (TST 5878) ASTM D1970 (AR) 376T0032 10/22/2019 PRI (TST 5878) ASTM D226 (S-CA) 376T0054 02/18/2020 PRI (TST 5878) ASTM D4533 (Gujarat, India) 376T0058 02/18/2020 PRI (TST 5878) ASTM D5035 (various) 376T0103 09/11/2020 PRI (TST 5878) ASTM D4533, D5035 (Rajasthan, India) 376T0111 12/22/2020 PRI (TST 5878) ASTM D4533, D5035 (Gujarat, India) 376T0113 12/22/2020 UL (TST 1740) ASTM D6757 (TX) 02NK22569 06/04/2002 PRI (TST 5878) ASTM D5035 (Gujarat, India) 376T0146 03/11/2021 PRI (TST 5878) ASTM D4533, D5035 (Rajasthan, India) 376T0161 05/07/2021 UL (TST 1740) ASTM D6757 (NC) 10NK11990 05/18/2011 NEMO ETC Traceability FBC Cross -Listing 04/22/2020 NEMO Traceability FBC Cross -Listing 04/08/2021 UL, LLC (QUA 9625) Quality Control Service Confirmation 03/23/2021 UL, LLC (QUA 9625) Quality Control Service Confirmation (AL) 05/04/2020 UL, LLC (QUA 9625) Quality Control Florida BCIS Current •e� i o Product Material Standard Plant(s) GAF Extended Dry -In Membrane ASTM D1970 Langley, BC Canada Liberty— SBS Self -Adhering Base/Ply Mt. Vernon, IN Sheet �_ ASTM D1970 Savannah, GA StormGuard® Film -Surfaced Leak Barrier ASTM D1970 Mt. Vernon, IN Savannah, GA -- Arkadelphia, AR WeatherWatchO Mineral -Surfaced Leak ASTM D1970 Mt. Vernon, IN Barrier Savannah, GA Tuscaloosa, AL Deck -Armor'"' Premium Breathable Roof 1507.1.1.1(2&3, Exception) / Deck Protection R905.1.1.1(2&3, Exception) Dadra, India Dadra, India FeltBuster'"" Synthetic Roofing Felt 1507.1.1.1(2&3, Exception), Gujarat, India (formerlyFeltBuster—High-Traction Synthetic 1507.1.1.1(5) itR905.1.1.1(2&3, (CPP) Rajasthan, India Roofing Felt) Exception), R905.1.1.1(5) (MIP) Rajasthan, India Richmond, VA Spartanburg, SC Shingle -Mate' Roof Deck Protection ASTM D226, Type II (Table 1) Pryor, OK Shafter, CA StormSafe'" Anchor Sheet 1507.1.1.1(2&3, Exception) / North Bay, ON R905.1.1.1(2&3, Exception) Tiger PawTM Premium Roof Deck Dadra, India 1507.1.1.1(2&3, Exception) / Gujarat, India Protection (formerly Tiger Paw —Roof Deck R905.1.1.1(2&3, Exception) Parzai, India Protection) Umerkui Kilvani, India VersaShield" Fire -Resistant Roof Deck Protection ASTM D6757 Conover, NC Ruberoid® Mop Granule ASTM D6164 Savannah, GA FRSA/TRI09-18 RuberoidO Mop Granule FR ASTM D6164 Savannah, GA FRSA/TRI 09-18 NEMO ETC, LLC Evaluation Report 01506.04.08-1122 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: 06/09/2021 Page 3 of 9 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBC Section: 1507.2 1507.3 1507.4 and 1507.5 1507.7 1507.8 and 1507.9 Clay and Concrete Tile Metal Slate or Wood Underlayment Asphalt Slate-Type Mechanical Adhesive- Shingles panels Shingles Shingles Shingles Shakes Attach Set Yes Yes GAF Extended Dry -In Membrane Yes No No Yes Yes Yes (Joint strips, (joint strips, 1507.1.1.3 / 1507.1.1.31 R905.1.1.3) R905.1.1.3) Yes Yes Liberty'" SBS Self -Adhering Yes No No No No No(joint Base/Ply Sheet 15071..1.3/ 15071..13/ R905.1.1.3) R905.1.1.3) Yes Yes StormGuard® Film -Surfaced L`e-&— Yes NO NO Yes Yes Yes (joint Barrier 15071.13/ 1507.1.1.3/ -- R905.1.1.3) R905.1.1.3) Yes Yes WeatherWatch® Mineral -Surfaced Yes No No No No No Ooint strips, (joint Ceak Barrier 1507.1.13/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Deck -Armor'" Premium Breathable Yes No No Yes Yes Yes No NORoof Deck Protection FeltBuster- Synthetic Roofing Felt Yes No No No No No No No Shingle -Mate® Roof Deck Yes No No No No No No No Protection Tiger Paw- Premium Roof Deck Yes No No Yes Yes Yes No No Protection VersaShield® Fire -Resistant Roof Yes No No No No No No No Deck Protection Yes Yes Ruberoid" Mop Granule No (Cap Sheet in (Cap Sheet in No No No No No 2-ply system) 2-ply system) See 5.6.1 Yes Yes Ruberoid' Mop Granule FR No (Cap Sheet in (Cap Sheet in No No No No No -ply system) 2 2-ply system) See 5.6.1 NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization #32455 7"' EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: 06/09/2021 Page 4 of 9 ON N EMO I etc. 5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval Ruberoid® Mop Granule; Ruberoid° Mop Granule FR Dupont "Tile BondT" Roof Tile Adhesive" FL22525 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Primer Substrates GAF Extended Dry -In Membrane self -adhering None plywood Liberty— SBS Self -Adhering Base/Ply Sheet self -adhering (Optional) ASTM D41 plywood StormGuard® Film -Surfaced Leak Barrier Weather Watch` Mineral -Surfaced Leak Barrier Liberty"' SBS Self -Adhering Base/Ply Sheet self -adhering None ASTM D226 felt, Type II ormGuar t urfaced Leak Barrier Weather Watch* Mineral -Surfaced Leak Barrier LibertyM SBS Self -Adhering Base/Ply Sheet self -adhering ASTM D41 metal (flashing metal, valley metal, etc.) StormGuard" Film -Surfaced Leak Barrier Weather Watch® Mineral -Surfaced Leak Barrier Ruberoid® Mop Granule hot asphalt ASTM D41 structural concrete Ruberoid® Mop Granule FR Ruberoid' Mop Granule hot asphalt None GAFGLAS® #80 Ultima— Base Sheet or Ruberoid' 20 Smooth Ruberoid® Mop Granule FR 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1 (for Two -Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: 06/09/2021 Page 5 of 9 DEMO I ea #1 Maximum Design Pressure = -442.5 psf. Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction Base Sheet: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #2 Maximum Design Pressure = -45 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS' #80 Ultima'" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid° Mop Granule FIR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. #3 Maximum Design Pressure = -75 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS' #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows in the field of the sheet. Cap Sheet: Ruberoid® Mop Granule or Ruberoid' Mop Granule FIR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. #4 Maximum Design Pressure = -97.5 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS' #80 UltimaT" Base Sheet or Ruberoid' 20 Smooth mechanically attached with 11 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field of the sheet. Cap Sheet: Ruberoid' Mop Granule or Ruberoid' Mop Granule FIR applied in full mopping of ASTM D312, Type IV hot asphalt at 20 to 25 Ibs/square. NEMO ETC, LLC Evaluation Report 01506.04.08-1122 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: 06/09/2021 Page 6 of 9 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Maximum Exposure Installation Type (days) Deck -Armor*"° Premium Breathable Roof Deck Protection, FeltBusterT Synthetic Roofing Felt, Shingle -Mate® Roof Deck Protection, StormSafeTm Anchor Sheet, Tiger PawTI Premium Roof Deck Protection, VersaShield® Fire -Resistant Roof Deck Mechanically attached 30 Protection, Liberty*"' SBS Self -Adhering Base/Ply Sheet, StormGuard® Film -Surfaced Leak Barrier and WeatherWatch® Mineral -Surfaced Leak Barrier GAF Extended Dry -In Membrane Mechanically attached 180 Ruberoid® Mop Granule and Ruberoid Mop Granule FIR Adhesive -set tile roofsystem 180 Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Staging Slope Ruberoid® Mop Granule Flat Max. 10-tile stack 4:12 Flat Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 5:12 Ruberoid® Mop Granule FR Flat or Lugged Max. 6-tile stack (4 over 2) 5:12 Lugged Max. 10-tile stack 4:12 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate (if applicable). 6.3 Deck -Armor TM Premium Breathable Roof Deck Protection or Tiger PawTI Premium Roof Deck Protection: 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.4 FeltBusterTM Synthetic Roofing Felt: 6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL10626-R22 GAF Roof Underlayments Revision 22: 06/09/2021 Page 7 of 9 NMEMO i etc. 6.5 StormSafe' Anchor Sheet: 6.5.1 StormSafeT" Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. 6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception) or 1507.1.1.1(3, Exception) or FBC Residential R905.1.1.1(2, Exception) or R905.1.1.1(3, Exception) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5.3 One the same day, install LibertyTM SBS Self -Adhering Base/Ply; StormGuard® Film -Surfaced Leak Barrier or WeatherWatch® Mineral -Surfaced Leak Barrier over the StormSafeT' Anchor Sheet. 6.6 Shingle -Mate® Roof Deck Protection: 6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.7 VersaShield® Fire -Resistant Roof Deck Protection: 6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D6757) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.8 GAF Extended Dry -In Membrane, LibertyTM' SBS Self -Adhering Base/Ply Sheet, StormGuard® Film -Surfaced Leak Barrier or WeatherWatch® Mineral -Surfaced Leak Barrier: 6.8.1 Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. 6.8.2 Back -nailing is required. Back -nailing shall consist of Approved cap nails spaced 18-inch o.c., encapsulated within min. 4-inch side laps. 6.8.3 When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.8.4 GAF Extended Dry -In Membrane, Liberty'"" SBS Self -Adhering Base/Ply Sheet, StormGuard® Film -Surfaced Leak Barrier or WeatherWatch® Mineral -Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6.9 Ruberoid® Mop Granule; Ruberoid® Mop Granule FR: 6.9.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. 6.9.2 Refer to Section 5.8 herein for attachment limitations. 6.9.3 Refer to Table 4 for tile staging limitations. NEMO ETC, LLC Evaluation Report 01506.04.08-R22 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION e L a 0626 GAF Roof Underlayments Revision 22: 06/09/2021 Page 8 of 9 As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL, LLC. — QUA9625; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION GAF Roof Underlayments Evaluation Report 01506.04.08-1122 FL10626-R22 Revision 22: 06/09/2021 Page 9 of 9