Loading...
HomeMy WebLinkAboutCreekside Lot 8Duct Leakage Test Report Prescriptive or Performance Method Permit # Job Information Builder: DR HORTON Community: CREEKSIDE Lot: 8 Address: 3319 HOMESTEAD DRIVE Unit: City: FORT PIERCE State: FL zip: 34945 Duct Leakage Test Results Presciptive Method 0 Performance Method System 1 System 2 System 3 Sum of any additional systems Total of all systems 40 Total of all systems PASS Testing Company cfm25 prescriptive Method cfm25 (total) To qualify as "substantially leak free" Qn must be less than or equal to 0.04 cfm25 if air handier unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to 0.03. This testing method meets the cfm25 requirements in accordance with Section R403.2.2 cfm25 25 1916 = 0.02 Qn Total Conditioned Square Footage FAIL 0 Performance Method cfm25 (Out or Total) To qualify as "substantially leak free" Qn must not be greater than the proposed duct leakage Qn specified on Form R405-2014 Leakage Type selected Qn specified on Form on Form R405-2014 R405-2014 (Energy Calc) (Energy Calc) Company Name: SUN SEAL LLC Phone: 321-412-0035 l hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 01 /07/2022 Signature of Tester: Printed Name of Tester: DANIEL MURPHY License/Certification # 5066440 Issuing Authority BPI Envelope Leakage Test Report (Blower Door Test) R405.4.2.1 Compliance [Permit # Job Information Builder: DR HORTON Community: CREEKSIDE Lot: 8 Address: 3319 HOMESTEAD DRIVE Unit: City: FORT PIERCE State: FL Zip: 34945 Air Leakage Test Results Passing results must be 7 ACH(SQ) or less 1190 x 60 - 16477.6 = 4.3 Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans ode software calculated , ,'` PASS FAIL Q Field measured and calculated ! When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. i Certification of Test Results R402.4.a.2 Testing. T he building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of au penetrations or the ouiiai Testing Company Company Name: SUN SEAL LLC Phone: 321-412-0035 J hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 01 /07/2022 "r Signature of Tester: Printed Name of Tester: DANIEL MURPHY License/Certification # 5066440 Issuing Authority