Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FLAT ROOF CT - SBS - FL2533_R26_II - Killday
NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 1 of 75 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 5-6 1B Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-7 1C Wood New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 8 1D Wood New, Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 9-10 1E Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 11-13 1F Wood New, Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13-16 1G Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-18 1H Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 18 2A Steel or Structural concrete New, Reroof (Tear-Off) or Recover B-1 Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 19-22 2B Steel or Structural concrete New, Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 22-26 2C Steel or Structural concrete New, Reroof (Tear-Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 27-29 3A Structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 30-39 3B Structural concrete New or Reroof (Tear-Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 40 3C Structural concrete New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 40 4A LWIC / steel New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42 4B LWIC / structural concrete New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 43-49 4C LWIC / structural concrete New, Reroof (Tear-Off) A-1 Bonded Vapor Barrier, Bonded Insulation, Bonded Roof Cover 50-51 4D LWIC / steel New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52-54 4E LWIC / steel or struct. conc. New or Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 55-59 4F LWIC / steel Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 60 4G LWIC / steel Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 60 5A Cementitious wood fiber New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 61-62 5B Cementitious wood fiber New or Reroof (Tear-Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 63 5C Cementitious wood fiber Reroof (Tear-Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 64 5D Cementitious wood fiber New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 64 6A Existing gypsum Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 65-67 6B Existing gypsum Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 68 6C Existing gypsum Reroof (Tear-Off) C-1 Mech. Attached Insulation, Bonded Roof Cover 69 6D Existing gypsum Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 69 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 70-75 7B Various Recover F Non-Insulated, Bonded Roof Cover 75 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 2 of 75 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: FlintFast #14 Fastener with FlintFast 3” Insulation Plates, Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3, OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plates. Minimum ¾-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: FlintFast #12 or #14 Fastener with FlintFast 3” Insulation Plates, Dekfast DF-#12-PH3 or DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3, OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate or Trufast #12 DP or Trufast #14 HD with Trufast 3” Metal Insulation Plates or. Minimum ¾-inch steel penetration and engage the top flute of the steel deck. ➢ Structural Concrete: FlintFast #14 Fastener with FlintFast 3” Insulation Plates, Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 or Dekfast PLT-R-3, OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate or Trufast #14 HD or Trufast Fluted Concrete Nail with Trufast 3” Metal Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer’s published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B, C or D, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non-wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application, the ribbons/beads shall expand as noted in the manufacturer’s published instructions. ➢ hot asphalt: Full coverage at 25-30 lbs/square ➢ “FlintFast QS Insulation Adhesive” (FlintFast QS): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. Note: HB Fuller “Millennium One Step Foamable Adhesive” may be used wherever FlintFast QS is listed. ➢ “FlintFast LV Insulation Adhesive” (FlintFast LV): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. Note: HB Fuller “Millennium PG-1 Pump Grade Adhesive” may be used wherever FlintFast LV is listed. ➢ Dupont “INSTA STIK Quik Set Commercial Roofing Adhesive” (Insta Stik QS): Continuous 0.75 to 1 inch wide ribbons, 12-inch o.c. ➢ ICP Adhesives and Sealants “Polyset Board-Max”: Continuous 3-inch ribbons, 12-inch o.c. ➢ ICP Adhesives and Sealants “Polyset CR-20”: Continuous 2.5 to 3-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 Adhesive Fastener (OB500): Continuous 0.75-inch wide ribbons, 12-inch o.c. (PaceCart, SpotShot or Canister) ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, boards shall be staggered from layer-to-layer. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to ‘increase’ the MDP listings in the tables, rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: ➢ FlintFast QS: MDP -157.5 psf (Min. 1.0-inch) ➢ FlintFast LV: MDP -157.5 psf (Min. 1.0-inch) ➢ Insta Stik QS: MDP -120.0 psf (Min. 1.0-inch) ➢ Polyset CR-20: MDP -117.5 psf (Min. 1.0-inch) ➢ OB500: MDP -45.0 psf (Min. 0.5-inch Multi-Max FA3) ➢ OB500: MDP -187.5 psf (Min. 0.5-inch ISO 95+ GL) ➢ OB500: MDP -315.0 psf (Min. 0.5-inch ENRGY 3) ➢ OB500: MDP -487.5 psf (Min. 0.5-inch ACFoam II) 8. For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 3 of 75 9. For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type D, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14. Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For “pre-existent” LWIC references, listings were established through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15. Unless otherwise noted, refer to the following references for bonded applications. MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-CA1 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Karnak No. 81 Cold Process Modified Bitumen Adhesive Brush Grade at 1 gal/square Note: Base ply cures overnight prior to application of the ply or cap ply. Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar BP-CA2 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Henry #903 Adhesive at 1.5 gal/square. SBS-CA2 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar BP-CA3 Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 HB Fuller “Millennium Hurricane Force Membrane Adhesive”, beads spaced 6-inch o.c. SBS-CA3 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 4 of 75 MEMBRANE / ADHESIVE COMBINATIONS REFERENCE LAYER MATERIAL APPLICATION SBS-CA4 Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base FlintBond Brush or Tropical Roofing Products #216 Modified Bitumen Adhesive at 1 to 1.5 gal/square. Note: Base ply cures overnight prior to application of the ply or cap ply. Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar BP-AA Base Ply: Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 hot asphalt at 20-40 lbs/square Ply: One or more Flintglas Ply 4, Flintglas Premium Ply 6 SBS-AA Base Ply: Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base hot asphalt at 20-40 lbs/square Ply: One or more Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Cap Ply: Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar SBS-TA Base Ply: Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T torch-applied Ply: One or more Flintlastic Ultra Poly SMS Base Sheet, Flintlastic Base 20 T Cap Ply: Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar APP-TA Base Ply: One or more Flintlastic APP Base T, Flintlastic STA, Flintlastic STA Plus torch-applied Cap Ply: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar SBS-SA-H Base Ply: Black Diamond Base Sheet, Flintlastic Ultra Glass SA self-adhering (activated by overlying membrane) SBS-SA Base Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply self-adhering Ply: Flintlastic SA PlyBase, Flintlastic SA Mid Ply Cap Ply: Flintlastic SA Cap, Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap FR, Flintlastic SA Cap FR CoolStar 16. Vapor barrier options for use over structural concrete deck followed by adhesive-applied insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A applies: VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION PER TABLE 3A, (The lesser of the MDP listings below vs. those in Table 3A applies) OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE ATTACH VB-1. FlintPrime QD, Karnak #108 or ASTM D41 Flintlastic SA PlyBase Self-adhering OB500, 12-inch o.c. -82.5 VB-2. None All Weather/Empire Base Sheet, 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, max. 6-inch o.c. FlintFast QS or FlintFast LV, 12-inch o.c. -82.5 VB-3. None Flintlastic Ultra Poly SMS Base Sheet, 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, max. 6-inch o.c. FlintFast QS or FlintFast LV, 12-inch o.c. -82.5 VB-4. FlintPrime QD, Karnak #108 or ASTM D41 primer Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering FlintFast QS or FlintFast LV, 12-inch o.c. -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 5 of 75 VAPOR BARRIER OPTIONS, STRUCTURAL CONCRETE DECK, ADHERED INSULATION PER TABLE 3A, (The lesser of the MDP listings below vs. those in Table 3A applies) OPTION # PRIMER VAPOR BARRIER INSULATION ADHESIVE MDP (PSF) TYPE ATTACH VB-5. FlintPrime QD, Karnak #108 or ASTM D41 primer Black Diamond Base Sheet, Flintlastic Ultra Glass SA or Flintlastic SA Cap Self-adhering FlintFast QS or FlintFast LV, 6-inch o.c. -315.0 VB-6. ASTM D41 or Karnak #108 Asphalt Primer Flintlastic GTA Torch-applied FlintFast QS or FlintFast LV, 12-inch o.c. -420.0 VB-7. FlintPrime QD, Karnak #108 or ASTM D41 primer Flintlastic Base 20 T or Flintlastic FR Cap 30 T Torch-applied FlintFast QS or FlintFast LV, 12-inch o.c. -495.0 17. ”MDP” = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-1 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H-Shield FlintFast QS or FlintFast LV (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. FlintFast QS or FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -60.0 W-2 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H-Shield FlintFast QS or FlintFast LV, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. FlintFast QS or FlintFast LV, 6- inch o.c. FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -97.5 HYBRID SYSTEMS: W-3 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H-Shield FlintFast QS or FlintFast LV (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. FlintFast QS or FlintFast LV None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 W-4 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H-Shield FlintFast QS or FlintFast LV, 6- inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. FlintFast QS or FlintFast LV, 6- inch o.c. None SBS-SA-H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -97.5 CONVENTIONAL SYSTEMS: W-5 Min. 15/32-inch APA rated CDX plywood, 24-inch span Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H-Shield FlintFast QS or FlintFast LV Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board FlintFast QS or FlintFast LV None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 6 of 75 TABLE 1A: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-6 Min. 15/32-inch APA rated CDX plywood, 24-inch span, blocked 48-inch o.c. Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H-Shield FlintFast QS or FlintFast LV, 6- inch o.c. Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board. FlintFast QS or FlintFast LV, 6- inch o.c. None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -97.5 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-7 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH or Multi-Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA - 45.0* W-8 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH or Multi-Max FA3 hot asphalt full coverage or FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max or Polyset CR-20, 4-inch o.c. Min. 0.25- inch DensDeck hot asphalt full coverage or FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max or Polyset CR-20, 6-inch o.c. FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -52.5 W-9 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH or Multi-Max FA3 hot asphalt full coverage or FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max or Polyset CR-20, 4-inch o.c. Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt full coverage or FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max or Polyset CR-20, 6-inch o.c. FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: W-10 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH or Multi-Max FA3 hot asphalt None N/A None SBS-SA-H (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA - 45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 7 of 75 TABLE 1B: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Sys. No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-11 Min. 19/32- inch plywood at max. 24- inch Glasbase Base Sheet, Flintglas Premium Ply 6 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH or Multi-Max FA3 hot asphalt None N/A None SBS-SA-H (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 CONVENTIONAL SYSTEMS: W-12 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20, Poly SMS, Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. in 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH or Multi-Max FA3 hot asphalt Min. 0.25- inch DensDeck hot asphalt ASTM D41 or Karnak #108 Asphalt Primer BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA - 45.0* W-13 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH or Multi-Max FA3 hot asphalt full coverage or FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max or Polyset CR-20, 4-inch o.c. Min. 0.25- inch DensDeck hot asphalt full coverage or FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max or Polyset CR-20, 6-inch o.c. ASTM D41 or Karnak #108 Asphalt Primer BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 W-14 Min. 19/32- inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Poly SMS or Ultra Poly SMS 32 ga., 1-5/8- inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. in 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH or Multi-Max FA3 hot asphalt full coverage or FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max or Polyset CR-20, 4-inch o.c. Min. 0.25- inch SECUROCK Gypsum- Fiber Roof Board hot asphalt full coverage or FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max or Polyset CR-20, 6-inch o.c. None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 8 of 75 TABLE 1C: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS: W-15 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH. FlintFast #12 or #14 with FlintFast 3” Insulation Plates 1 per 1.3 ft2 Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH. hot asphalt, FlintFast QS, FlintFast LV, Insta Stik QS, OB500 SBS-SA-H (Optional) APP-TA APP-TA -67.5 CONVENTIONAL SYSTEMS: W-16 Min. 23/32-inch plywood, 24-inch span Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 2.0 ft2 Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* W-17 Min. 23/32-inch plywood, 24-inch span Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 2.0 ft2 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* W-18 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH. FlintFast #12 or #14 with FlintFast 3” Insulation Plates 1 per 1.3 ft2 Optional additional layer(s) of base insulation followed by Min. 0.25-inch SECUROCK Gypsum-Fiber Roof board hot asphalt, FlintFast QS, FlintFast LV, Insta Stik QS, OB500 APP-TA (Optional) APP-TA APP-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 9 of 75 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: W-19 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 3.2 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -30.0* W-20 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.3 ft2 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -45.0 W-21 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-22 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH, Multi-Max FA3 FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -45.0* W-23 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -52.5 W-24 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH, Multi-Max FA3 Note 2 1 per 1.45 ft2 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -60.0 HYBRID SYSTEMS: W-25 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -30.0* W-26 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 10 of 75 TABLE 1D: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply W-27 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) BP- AA or SBS-AA SBS-AA -52.5 W-28 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Note 2 1 per 1.45 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -60.0 W-29 Min. 15/32-inch plywood, 24-inch span (Optional) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -75.0 W-30 Min. 19/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -82.5 CONVENTIONAL SYSTEMS: W-31 Min. 23/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.0 ft2 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -45.0* W-32 Min. 15/32-inch plywood, 24-inch span (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -45.0* W-33 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None APP-TA (Optional) APP- TA APP-TA -60.0 W-34 Min. 19/32-inch plywood, 24-inch span (Optional for Concrete or Recover) Min. 2-inch ACFoam II, FlintBoard, H-Shield or ENRGY 3, loose laid. Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -60.0 W-35 Min. 15/32-inch plywood, 24-inch span (Optional for Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None APP-TA (Optional) APP- TA APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 11 of 75 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-36 Min. 19/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows Prime stress plates with Karnak #108 (Optional) SBS-SA SBS-SA -82.5* W-37 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows Prime stress plates with Karnak #108 (Optional) SBS-SA SBS-SA -97.5* W-38 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic SA NailBase FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Prime stress plates with Karnak #108 (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-39 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows Prime stress plates with Karnak #108 SBS-SA-H SBS-AA, SBS-TA or APP-TA -97.5 W-40 Min. 19/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA, SBS-TA or APP-TA -105.0 W-41 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows Prime stress plates with Karnak #108 SBS-SA-H SBS-AA, SBS-TA or APP-TA -127.5 CONVENTIONAL SYSTEMS: W-42 Min. 23/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0* W-43 Min. 23/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 12-inch o.c. at 4-inch lap and 24-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 12 of 75 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply W-44 Min. 23/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* W-45 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -97.5 W-46 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None APP-TA APP-TA -97.5 W-47 Min. 15/32-inch plywood, 24-inch span One or more layers, any thickness or combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. at three (3) equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP_TA -97.5 W-48 Min. 19/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 W-49 Min. 19/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T Dekfast DF-#14-PH3 with PLT-H- 2-7/8 or OMG #14 HD with OMG 3 in. Round Metal Plate 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 W-50 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -127.5 W-51 Min. 15/32-inch plywood, 24-inch span Min. 1.5-inch, One or more layers, any combination Prelim. Attach Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 13 of 75 TABLE 1E: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply W-52 Min. 15/32-inch plywood, 24-inch span Min. 1-inch, One or more layers, any combination Loose- laid Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-53 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 9-inch o.c. at min. 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows ASTM D41 primer at plates (Optional) SBS-SA SBS-SA -45.0* W-54 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -52.5 W-55 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -52.5 W-56 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB, 24- inch span Flintlastic SA NailBase Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows ASTM D41 primer at plates (Optional) Flintlastic SA Mid Ply, self- adhering SBS-SA -52.5 W-57 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at min. 2-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -60.0 W-58 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Simplex MAXX Cap 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows ASTM D41 primer at plates (Optional) SBS-SA SBS-SA -67.5 W-59 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 W-60 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase Cap nails: 1-inch diameter, 0.032-inch thick metal cap with 0.120" shank diameter, annular ring shank nails 7-inch o.c. at min. 4-inch laps and 7-inch o.c. in five (5), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 14 of 75 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-61 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at min. 2-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) SBS-SA SBS-SA -105.0 HYBRID SYSTEMS: W-62 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None SBS-SA-H SBS-AA, SBS- TA or APP-TA -45.0* W-63 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA, SBS- TA or APP-TA -52.5 W-64 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA, SBS- TA or APP-TA -52.5 W-65 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA, SBS- TA or APP-TA -60.0 W-66 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA, SBS- TA or APP-TA -82.5 W-67 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None SBS-SA-H SBS-AA, SBS- TA or APP-TA -105.0 CONVENTIONAL SYSTEMS: W-68 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 9-inch o.c. at 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* W-69 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* W-70 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 15 of 75 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-71 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Min. 1-inch long, 12 ga. Simplex Metal Cap Nails 6-inch o.c. at 3-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 W-72 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 W-73 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 W-74 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -52.5 W-75 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 8-inch o.c. at 4-inch lap and 8-inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -60.0 W-76 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Cap nails: 1-inch diameter, 0.032-inch thick metal cap with 0.120-inch shank diameter, annular ring shank nails. 6-inch o.c. at 4-inch lap and 6-inch o.c. at five (5) equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -67.5 W-77 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 6-inch o.c. at 4-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -82.5 W-78 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -90.0 W-79 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -90.0 W-80 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet 32 ga., 1-5/8-inch dia. tin caps with 11 ga. annular ring shank nails 4-inch o.c. at 3-inch lap and 4-inch o.c. in four (4), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 16 of 75 TABLE 1F: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-81 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) BP- AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -105.0 W-82 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows None (Optional) APP-TA APP-TA -105.0 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: W-83 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB, 24-inch span Flintlastic SA NailBase Trufast Versa Fasteners & Plates, two (2) screws per plate at 180° from each other* 9-inch o.c. at min. 3-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows ASTM D41 primer at plates (Optional) Flintlastic SA Mid Ply, self- adhering SBS-SA -60.0* Note: *For re-roof (tear-off) or recover applications, field withdrawal resistance testing (Note 11) shall yield minimum 109 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 1” penetration through OSB sheathing. W-84 Min. 19/32-inch plywood, 24-inch span Flintlastic SA NailBase Note 2 8-inch o.c. at min. 3-inch lap and 8-inch o.c. in two (2), equally spaced, staggered center rows Prime stress plates with Karnak #108 (Optional) SBS-SA SBS-SA -82.5* W-85 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in three (3), equally spaced, staggered center rows Prime stress plates with Karnak #108 (Optional) SBS-SA SBS-SA -97.5* W-86 Min. 15/32-inch plywood, 24-inch span Flintlastic SA NailBase FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at min. 2-inch lap and 6-inch o.c. in four (4), equally spaced, staggered center rows Prime stress plates with Karnak #108 (Optional) SBS-SA SBS-SA -127.5* HYBRID SYSTEMS: W-87 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows Prime stress plates with Karnak #108 SBS-SA-H SBS-AA, SBS- TA or APP-TA -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 17 of 75 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-88 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None SBS-SA-H SBS-AA, SBS- TA or APP-TA -105.0 W-89 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows Prime stress plates with Karnak #108 SBS-SA-H SBS-AA, SBS- TA or APP-TA -127.5 CONVENTIONAL SYSTEMS: W-90 Min. 23/32-inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -30.0* W-91 Min. 23/32-inch plywood, 24-inch span Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 12-inch o.c. at 4-inch lap and 24- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* W-92 Min. 23/32-inch plywood, 24-inch span Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* W-93 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -97.5 W-94 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in three (3), equally spaced, staggered center rows. None APP-TA APP-TA -97.5 W-95 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. at three (3) equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA or SBS-TA SBS-AA or SBS-TA -97.5 W-96 Min. 19/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -105.0 W-97 Min. 19/32-inch plywood, 24-inch span Flintlastic APP Base T Dekfast DF-#14-PH3 with PLT-H-2-7/8 or OMG #14 HD with OMG 3 in. Round Metal Plate 7-inch o.c. at 3-inch lap and 7- inch o.c. in three (3), equally spaced, staggered center rows None APP-TA APP-TA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 18 of 75 TABLE 1G: WOOD DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners Attach Base Ply Cap Ply W-98 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate, OMG #14 HD with OMG 3 in. Round Metal Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows None (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -127.5 W-99 Min. 15/32-inch plywood, 24-inch span Flintlastic APP Base T OMG #14 HD with OMG 3 in. Round Metal Plates 6-inch o.c. at 4-inch lap and 6- inch o.c. in four (4), equally spaced, staggered center rows. None APP-TA APP-TA -127.5 COLD-APPLIED SYSTEMS: W-100 Min. 15/32-inch plywood, 24-inch span Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #12 or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP or #14 HD with Trufast 3” Metal Insulation Plate 8-inch o.c. at 4-inch lap and 8- inch o.c. in three (3), equally spaced, staggered center rows None (Optional) SBS-CA1 SBS-CA1 -52.5 TABLE 1H: WOOD DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply W-101 APA rated, min. 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing, 24-inch span FlintPrime QD, Karnak #108 or ASTM D41 primer Flintlastic SA Mid Ply, self-adhering (Optional) SBS-SA SBS-SA -90.0 W-102 Min. 15/32-inch plywood, 24-inch span FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -112.5 W-103 Min. 15/32-inch plywood, 24-inch span FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -127.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 19 of 75 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: S-1 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 4.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max, Polyset CR-20 SBS-SA (Optional) SBS-SA SBS-SA -37.5* S-2 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max, Polyset CR-20 SBS-SA (Optional) SBS-SA SBS-SA -45.0* HYBRID SYSTEMS: S-3 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 1.45 ft2 Additional layer(s) base insulation hot asphalt, FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max, Polyset CR-20 Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -37.5 S-4 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 1.45 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max, Polyset CR-20 Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -52.5 S-5 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH. FlintFast #12 or #14 with FlintFast 3” Insulation Plates 1 per 1.45 ft2 Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield or FlintBoard ISOH. hot asphalt, FlintFast QS, FlintFast LV, Insta Stik QS, OB500 SBS-SA-H (Optional) APP- TA APP-TA -67.5 S-6 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS, FlintFast LV, Insta Stik QS, OB500 SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 20 of 75 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-7 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -90.0* CONVENTIONAL SYSTEMS: S-8 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 4.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max, Polyset CR-20 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -37.5* S-9 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-10 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch DensDeck or DensDeck Prime hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-11 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max, Polyset CR-20 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-12 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 3.2 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous). hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 21 of 75 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-13 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 3.2 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch DensDeck or DensDeck Prime hot asphalt BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-14 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, Multi-Max FA3 Note 2 1 per 1.3 ft2 Min. 0.75-inch FescoBoard (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 S-15 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH Note 2 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt, FlintFast QS, Insta Stik QS, OB500, Polyset Board-Max, Polyset CR-20 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 S-16 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, Multi-Max FA3 Note 2 1 per 1.3 ft2 Min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -67.5 S-17 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS, FlintFast LV, Insta Stik QS, OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -75.0 S-18 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -90.0* COLD-APPLIED SYSTEMS: S-19 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H- Shield CG or FlintBoard Iso ColdH OB500 or Polyset CR-20 SBS-CA1 None SBS-CA1 -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 22 of 75 TABLE 2A: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE B-1: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply S-20 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS, FlintFast QS, FlintFast LV, OB500, Polyset Board-Max or Polyset CR-20 SBS-CA1 None SBS-CA1 -45.0* S-21 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 2-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 Optional min. 1.5-inch additional layer(s) base insulation, followed by min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS, FlintFast QS, FlintFast LV, OB500, Polyset Board-Max or Polyset CR-20 SBS-CA4 None SBS-CA4 -45.0* S-22 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS, FlintFast LV, Insta Stik QS, OB500 SBS-CA1 None SBS-CA1 -75.0 S-23 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch ENRGY 3 FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 Min. 0.5-inch SECUROCK Gypsum-Fiber Roof Board OB500, 4-inch o.c. SBS-CA1 None SBS-CA1 -90.0* TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: S-24 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Note 2 1 per 3.2 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -30.0* S-25 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -37.5* S-26 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum- Fiber Roof Board Note 2 1 per 2.7 ft2 None SBS-SA (Optional) SBS- SA SBS-SA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 23 of 75 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-27 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck Note 2 1 per 1.3 ft2 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -45.0 S-28 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 ASTM D41 or Karnak #108 Asphalt Primer SBS-SA (Optional) SBS- SA SBS-SA -67.5 S-29 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 ASTM D41 or Karnak #108 Asphalt Primer SBS-SA (Optional) SBS- SA SBS-SA -82.5 S-30 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO, FlintBoard H ISO, ACFoam II or H-Shield FlintFast #15 (steel only) or FlintFast #14 (concrete only) with FlintFast 3 in. Insulation Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 ASTM D41 or Karnak #108 Asphalt Primer SBS-SA (Optional) SBS- SA SBS-SA -97.5 HYBRID SYSTEMS: S-31 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck, DensDeck Prime Note 2 1 per 2.0 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0* S-32 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -37.5* S-33 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-SA- H (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-34 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.8 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -67.5 S-35 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield or FlintBoard ISOH. FlintFast #12 (steel only) or FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 24 of 75 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-36 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.6 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -82.5 S-37 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -82.5 S-38 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi-Max FA3 Note 2 1 per 1.3 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -82.5 S-39 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch FlintBoard ISO, FlintBoard H ISO, ACFoam II or H-Shield FlintFast #15 (steel only) or FlintFast #14 (concrete only) with FlintFast 3 in. Insulation Plate or Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None SBS-SA- H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -97.5 S-40 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None SBS-SA- H (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -135.0 CONVENTIONAL SYSTEMS: S-41 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.7 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -30.0* S-42 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -37.5* S-43 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -37.5* S-44 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Note 2 1 per 4.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 25 of 75 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-45 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation, min. 0.75-inch FescoBoard (homogeneous) Note 2 1 per 2.0 ft2 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-46 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime Note 2 1 per 2.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* S-47 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch, One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None APP-TA (Optional) APP- TA APP-TA -60.0 S-48 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 2-inch ACFoam II, FlintBoard, H- Shield or ENRGY 3, loose laid. Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board Note 2 1 per 1.8 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 S-49 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -82.5 S-50 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch ACFoam II, FlintBoard, H- Shield Min. 0.5-inch DensDeck Prime FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -112.5 S-51 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA, SBS-TA or APP- TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -135.0 S-52 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch ACFoam II, FlintBoard, H- Shield Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.3 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -157.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 26 of 75 TABLE 2B: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners Attach Base Ply Ply Cap Ply S-53 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch ACFoam II, FlintBoard, H- Shield Min. 0.5-inch DensDeck Prime FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -157.5 S-54 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional for Concrete or Recover) Min. 1.5-inch ACFoam II, FlintBoard, H- Shield Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.0 ft2 None BP-AA, SBS-AA (Optional) BP- AA, SBS-AA SBS-AA -172.5 COLD-APPLIED SYSTEMS: S-55 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA1 None SBS-CA1 -37.5* S-56 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA4 None SBS-CA4 -37.5* S-57 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.0 ft2 None SBS-CA1 None SBS-CA1 -45.0* S-58 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA1 None SBS-CA1 -45.0* S-59 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 3/8-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 2.7 ft2 None SBS-CA4 None SBS-CA4 -45.0* S-60 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete (Optional) One or more layers, any combination, loose laid Min. 0.5-inch SECUROCK Gypsum- Fiber Roof Board FlintFast #12 (steel only) or #14 with FlintFast 3 in. Insulation Plate or Trufast #12 DP (steel only) or #14 HD with Trufast 3” Metal Insulation Plate 1 per 1.45 ft2 None SBS-CA1 None SBS-CA1 -82.5* NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 27 of 75 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: S-61 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 9-inch o.c. at min. 2-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -45.0* S-62 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 2-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -52.5* S-63 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase Note 2 12-inch o.c. at min. 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) SBS- SA SBS-SA -60.0* S-64 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic SA NailBase (laid parallel to deck flutes) Note 2 8-inch o.c. at min. 4-inch lap and 8- inch o.c. in two (2), equally spaced, staggered center rows, ASTM D41 primer at plates (Optional) SBS- SA SBS-SA -82.5* CONVENTIONAL SYSTEMS: S-65 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -30.0* S-66 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 12-inch o.c. at 4-inch lap and 24- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -45.0* S-67 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 36- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -45.0* S-68 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 18-inch o.c. at 4-inch lap and 18- inch o.c. in one (1) staggered center row BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -45.0* S-69 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Dekfast DF-#14-PH3 with PLT-R-2-4B 12-inch o.c. within the min. 4-inch wide, heat-welded side lap SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* S-70 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet Note 2 12-inch o.c. at 3-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -52.5 S-71 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2” Barbed Metal Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 28 of 75 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply S-72 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Barbed Metal Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -60.0 S-73 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 12-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -67.5 S-74 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet OMG #14 HD with OMG Flat Bottom Plates (AccuTrac) 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -67.5 S-75 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Base 20 Note 2 6-inch o.c. at 4-inch lap and 6-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP- TA SBS-AA, SBS- TA or APP-TA -67.5 S-76 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attach Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 6-inch o.c. at three (3) equally spaced, staggered center rows (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -97.5 S-77 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 6-inch o.c. within the min. 4-inch wide, heat-welded side lap (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -112.5 S-78 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-TA or APP- TA SBS-TA or APP-TA -112.5 S-79 Min. 22 ga., type B, Grade 80 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Note 2 12-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-AA SBS-AA or SBS-TA -120.0 S-80 Min. 22 ga., type B, 40 ksi steel or min. 2,500 psi structrual concrete Min. 2-inch, One or more layers, any combination Prelim. Attached Flintlastic Ultra Poly SMS Base Sheet Trufast #15 EHD (steel only) or Trufast #14 HD (concrete only) with Trufast 2.4” Scoop Seam Plate 6-inch o.c. within the min. 4-inch wide, heat-welded side laps and 6- inch o.c. in one (1) center row, stripped-in with 6-inch side strips of torch-applied Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet. (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -165.0 COLD-APPLIED SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 29 of 75 TABLE 2C: STEEL OR STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Attach Type Fasteners Attach Base Ply Cap Ply S-81 Min. 22 ga., type B, Grade 33 steel or min. 2,500 psi structrual concrete Min. 1.5-inch, One or more layers, any combination Prelim. Attached Glasbase Base Sheet, All Weather/Empire Base Sheet, Flintlastic Base 20 Note 2 6-inch o.c. at 4-inch lap and 12- inch o.c. in two (2), equally spaced, staggered center rows SBS-CA1 SBS-CA1 -45.0* S-82 Min. 22 ga., type B, Grade 40 steel or min. 2,500 psi structrual concrete Min. 1-inch, One or more layers, any combination Loose-laid Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet FlintFast #14 with FlintFast 3 in. Insulation Plate or Trufast #14 HD with Trufast 3” Metal Insulation Plate 6-inch o.c. at 4-inch lap and 12- inch o.c. in three (3), equally spaced, staggered center rows (Optional) SBS- CA1 SBS-CA1 -75.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 30 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: C-1. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-2. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, Multi- Max FA3 hot asphalt Min. 0.25-inch DensDeck hot asphalt FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -192.5 C-3. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -97.5 C-4. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-5. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, Multi- Max FA3 FlintFast QS or FlintFast LV Min. 0.25-inch DensDeck FlintFast QS or FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -192.5 C-6. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV, 6- inch o.c. ASTM D41 or Karnak #108 Asphalt Primer SBS-SA (Optional) SBS- SA SBS-SA -315.0 C-7. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV, 6- inch o.c. FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -315.0 C-8. Structural concrete (Optional) ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch Multi-Max FA Insta Stik QS Min. 0.25-inch DensDeck Insta Stik QS FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 31 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-9. Structural concrete (Optional) ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ENRGY 3 Insta Stik QS Min. 0.25-inch DensDeck Insta Stik QS FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -112.5 C-10. Structural concrete (Optional) ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II or FlintBoard Insta Stik QS Min. 0.25-inch DensDeck Insta Stik QS FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -120.0 C-11. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH Insta Stik QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-12. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -120.0 C-13. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -150.0 C-14. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-15. Structural concrete None Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra- Max Polyset Board- Max or Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max or Polyset CR-20 None SBS-SA (Optional) SBS- SA SBS-SA -172.5 C-16. Structural concrete None Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra- Max Polyset Board- Max or Polyset CR-20 Min. 0.25-inch DensDeck Polyset Board- Max or Polyset CR-20 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS- SA SBS-SA -192.5 HYBRID SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 32 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-17. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH hot asphalt (Optional) Additional layer(s) base insulation hot asphalt None Flintlastic Ultra Glass SA (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -322.5 C-18. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH hot asphalt (Optional) Additional layer(s) base insulation hot asphalt None Black Diamond Base Sheet (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -375.0 C-19. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -97.5 C-20. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS (Optional) Additional layer(s) base insulation FlintFast QS None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -232.5 C-21. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -217.5 C-22. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -195.0 C-23. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast LV (Optional) Additional layer(s) base insulation FlintFast LV None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -270.0 C-24. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast LV None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -217.5 C-25. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast LV None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -195.0 C-26. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch ACFoam- HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV, 6- inch o.c. None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -315.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 33 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-27. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Insta Stik QS (Optional) Additional layer(s) base insulation Insta Stik QS None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -135.0 C-28. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Insta Stik QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -217.5 C-29. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -195.0 C-30. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 (Optional) Additional layer(s) base insulation OB500 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -135.0 C-31. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -217.5 C-32. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -195.0 C-33. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max or Polyset CR-20 (Optional) Additional layer(s) base insulation Polyset Board- Max or Polyset CR-20 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -270.0 C-34. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max or Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max or Polyset CR-20 None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -217.5 C-35. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max or Polyset CR-20 None N/A None SBS-SA-H (Optional) SBS- AA, SBS-TA, APP- TA SBS-AA, SBS-TA, APP-TA -195.0 CONVENTIONAL SYSTEMS: C-36. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II or FlintBoard ISO. hot asphalt Min. 0.25-inch DensDeck, DensDeck Prime hot asphalt None SBS-TA (Optional) SBS- TA SBS-TA -180.0 C-37. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer (Optional) Min. 1.5-inch ACFoam II or FlintBoard ISO. hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 34 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-38. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer (Optional) Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-39. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None APP-TA (Optional) APP- TA APP-TA -252.5 C-40. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH hot asphalt Min. 0.5-inch Structodek High Density Fiberboard hot asphalt None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -227.0 C-41. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer (Optional) Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -232.5 C-42. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH hot asphalt Min. 0.25-inch DensDeck hot asphalt None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 C-43. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II or FlintBoard ISO hot asphalt Min. 0.75-inch FescoBoard (homogeneous) hot asphalt None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -412.0 C-44. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 1.5-inch ACFoam II or FlintBoard ISO hot asphalt Min. 0.5-inch DuraBoard (homogeneous) hot asphalt None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -430.0 C-45. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer 0.5-inch Structodek High Density Fiberboard or min. 0.75- inch Fesco Board (homogeneous) hot asphalt None N/A None BP-AA (Optional) BP-AA or SBS-AA SBS-AA -437.5 C-46. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board hot asphalt None N/A None SBS-TA (Optional) SBS- AA or SBS-TA SBS-AA or SBS-TA -302.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 35 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-47. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None N/A None Flintlastic Ultra Poly SMS Base Sheet, torched (Optional) Flintlastic Ultra Poly SMS Base Sheet, torched SBS-TA -487.5 C-48. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board hot asphalt None N/A None BP-AA (Optional) BP-AA or SBS-AA SBS-AA -537.5 C-49. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast QS Min. 0.5-inch Structodek High Density Fiberboard FlintFast QS None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -127.5 C-50. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast LV Min. 0.5-inch Structodek High Density Fiberboard FlintFast LV None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 C-51. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast QS Min. 0.25-inch DensDeck FlintFast QS None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -232.5 C-52. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast LV Min. 0.25-inch DensDeck FlintFast LV None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 C-53. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast LV Min. 0.25-inch DensDeck Prime FlintFast LV None BP-AA, SBS- AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-54. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast LV Min. 0.25-inch DensDeck Prime FlintFast LV None SBS-TA (Optional) SBS- TA SBS-TA -302.5 C-55. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-56. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -232.5 C-57. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None APP-TA (Optional) APP- TA APP-TA -252.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 36 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-58. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None BP-AA, SBS- AA or SBS- TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-59. Structural concrete None 0.5-inch Structodek High Density Fiberboard FlintFast LV None N/A None BP-AA, SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-60. Structural concrete None Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast LV None N/A None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-61. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV, 6- inch o.c. None SBS-AA or SBS-TA (Optional) SBS- AA or SBS-TA SBS-AA or SBS-TA -315.0 C-62. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV, 6- inch o.c. None Flintlastic STA or Flintlastic STA Plus (Optional) APP- TA APP-TA -315.0 C-63. Structural concrete None Min. 1.5-inch ACFoam II or FlintBoard ISO. Insta Stik QS Min. 0.25-inch DensDeck Insta Stik QS None SBS-TA (Optional) SBS- TA SBS-TA -112.5 C-64. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Insta Stik QS Min. 0.25-inch DensDeck Prime Insta Stik QS None BP-AA, SBS- AA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-65. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Insta Stik QS Min. 0.25-inch DensDeck Prime Insta Stik QS None SBS-TA (Optional) SBS- TA SBS-TA -302.5 C-66. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH Insta Stik QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-67. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH Insta Stik QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS None SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -232.5 C-68. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Insta Stik QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS None APP-TA (Optional) APP- TA APP-TA -252.5 C-69. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Insta Stik QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS None BP-AA, SBS- AA or SBS- TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 37 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-70. Structural concrete None 0.5-inch Structodek High Density Fiberboard Insta Stik QS None N/A None BP-AA, SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-71. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Insta Stik QS None N/A None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-72. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 C-73. Structural concrete None Min. 1.5-inch ACFoam II or FlintBoard ISO. OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -150.0 C-74. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch DensDeck Prime OB500 None BP-AA, SBS- AA or SBS- TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-75. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-76. Structural concrete None Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -232.5 C-77. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None APP-TA (Optional) APP- TA APP-TA -252.5 C-78. Structural concrete None Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS- AA or SBS- TA (Optional) BP- AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -297.5 C-79. Structural concrete None 0.5-inch Structodek High Density Fiberboard OB500 None N/A None BP-AA, SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-80. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None N/A None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 38 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-81. Structural concrete None Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra- Max Polyset Board- Max or Polyset CR-20 Min. 0.5-inch Structodek High Density Fiberboard Polyset CR-20 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 C-82. Structural concrete None Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H, min. 1.3- inch ACFoam III, FlintBoard ISO Cold or min. 1.5-inch Multi-Max FA3, Ultra-Max Polyset Board- Max or Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max or Polyset CR-20 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -225.0 C-83. Structural concrete None Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra- Max Polyset Board- Max or Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max or Polyset CR-20 None SBS-TA or APP-TA (Optional) SBS- TA or APP-TA SBS-TA or APP-TA -232.5 C-84. Structural concrete None Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra- Max Polyset Board- Max or Polyset CR-20 Min. 0.25-inch DensDeck Polyset Board- Max or Polyset CR-20 None BP-AA or SBS-AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -240.0 C-85. Structural concrete None 0.5-inch Structodek High Density Fiberboard Polyset Board- Max or Polyset CR-20 None N/A None BP-AA, SBS- AA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 C-86. Structural concrete None Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max or Polyset CR-20 None N/A None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 COLD-APPLIED SYSTEMS: C-87. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch DEXcell FA Glass Mat Roof Board FlintFast QS or FlintFast LV None Flintlastic Poly SMS Base Sheet in Karnak #81 (Optional) Flintlastic Poly SMS Base Sheet in Karnak #81 SBS-CA1 -90.0 C-88. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV None SBS-CA1 None SBS-CA1 -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 39 of 75 TABLE 3A: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER SEE NOTE 16 FOR VAPOR BARRIER OPTIONS Sys. No. Deck (Note 1) Primer Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply C-89. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV None SBS-CA4 None SBS-CA4 -97.5 C-90. Structural concrete None Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None SBS-CA1 None SBS-CA1 -105.0 C-91. Structural concrete None Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None SBS-CA4 None SBS-CA4 -105.0 C-92. Structural concrete None (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.25-inch DEXcell FA Glass Mat Roof Board FlintFast QS or FlintFast LV, 6- inch o.c. None Flintlastic Poly SMS Base Sheet in Karnak #81 (Optional) Flintlastic Poly SMS Base Sheet in Karnak #81 SBS-CA1 -112.5 C-93. Structural concrete None (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH OB500 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H- Shield CG or FlintBoard Iso ColdH OB500 None SBS-CA1 None SBS-CA1 -82.5 C-94. Structural concrete None Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0 C-95. Structural concrete None Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0 C-96. Structural concrete None (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH Polyset Board- Max or Polyset CR-20 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H- Shield CG or FlintBoard Iso ColdH Polyset Board- Max or Polyset CR-20 None SBS-CA1 None SBS-CA1 -82.5 C-97. Structural concrete None Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max or Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max or Polyset CR-20 None SBS-CA1 None SBS-CA1 -105.0 C-98. Structural concrete None Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max or Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max or Polyset CR-20 None SBS-CA4 None SBS-CA4 -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 40 of 75 TABLE 3B: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-3: BONDED TEMP ROOF, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Primer Temp Roof Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply COLD-APPLIED SYSTEMS: C-99. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 Flintlastic SA PlyBase, self- adhered (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH OB500 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH OB500 SBS-CA1 None SBS-CA1 -82.5 C-100. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 Flintlastic SA PlyBase, self- adhered Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA1 None SBS-CA1 -82.5 C-101. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 Flintlastic SA PlyBase, self- adhered Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-CA4 None SBS-CA4 -82.5 TABLE 3C: STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: C-102. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 SBS-SA (Optional) SBS-SA SBS-SA -630.0 HYBRID SYSTEMS: C-103. Structural concrete Karnak #108 Asphalt Primer Flintlastic Ultra Glass SA (Optional) SBS-AA SBS-AA -135.0 C-104. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 SBS-SA-H (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -150.0 C-105. Structural concrete Karnak #108 Asphalt Primer Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA SBS-TA, APP-TA -322.5 C-106. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 SBS-SA-H (Optional) BP-AA, SBS-AA SBS-AA -240.0 C-107. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 BP-AA, SBS-AA SBS-SA-H SBS-AA, SBS-TA, APP-TA -635.0 CONVENTIONAL SYSTEMS: C-108. Structural concrete Karnak #108 Asphalt Primer APP-TA (Optional) APP-TA APP-TA -420.0 C-109. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 SBS-TA (Optional) SBS-TA SBS-TA -542.5 C-110. Structural concrete FlintPrime QD, Karnak #108 or ASTM D41 BP-AA, SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -635.0 COLD-APPLIED SYSTEMS: C-111. Structural concrete ASTM D41 or Karnak #108 Asphalt Primer SBS-CA1 (Optional) SBS-CA1 SBS-CA1 -262.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 41 of 75 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap Ply CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-1 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast QS Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board FlintFast QS SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-2 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast LV Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board FlintFast LV SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-3 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-4 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset Board- Max Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset Board- Max SBS-SA (Optional) SBS- SA SBS-SA -52.5 LWC-5 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset CR-20 SBS-SA (Optional) SBS- SA SBS-SA -52.5 HYBRID SYSTEMS: LWC-6 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast QS, FlintFast LV, OB500, Polyset Board-Max, Polyset CR-20 (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS, FlintFast LV, OB500, Polyset Board-Max, Polyset CR-20 SBS-SA-H (Optional) SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 CONVENTIONAL SYSTEMS: LWC-7 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast QS Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board FlintFast QS BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 42 of 75 TABLE 4A: LIGHTWEIGHT CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach Type Attach Base Ply Ply Cap Ply LWC-8 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast LV Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board FlintFast LV BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 LWC-9 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 LWC-10 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset Board- Max Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset Board- Max BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 LWC-11 Min. 22 ga., Type BV, Grade 33 steel, 6 ft span Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset CR-20 BP-AA or SBS-AA, SBS- TA or APP-TA (Optional) BP- AA, SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP-TA -52.5 ELASTIZELL (FL4994): COLD APPLIED SYSTEMS: LWC-12 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. Min. 1.5-inch H-Shield CG, FlintBoard ISO Cold H OB500, 6-inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP- CA3 or SBS-CA3 SBS-CA3 -60.0 LWC-13 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span Min. 350 psi, min 2-inch Range II Elastizell with Zell- Crete Fibers. When walkable, attach LWC with FlintFast #14 and FlintFast 3” Round Plates at 1 per 8 ft2 through to the structural deck. Min. 1.5-inch H-Shield CG, FlintBoard ISO Cold H OB500, 6-inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. BP-CA3 or SBS-CA3 (Optional) BP- CA3 or SBS-CA3 SBS-CA3 -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 43 of 75 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-14 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast QS Min. 0.25-inch DensDeck FlintFast QS FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -90.0 LWC-15 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS None SBS-SA (Optional) SBS-SA SBS-SA -90.0 LWC-16 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-17 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast QS Min. 0.25-inch DensDeck FlintFast QS FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-18 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS ASTM D41 or Karnak #108 Asphalt Primer SBS-SA (Optional) SBS-SA SBS-SA -217.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 44 of 75 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-19 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast LV None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-20 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast LV None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-21 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast LV Min. 0.25-inch DensDeck FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-22 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast LV Min. 0.25-inch DensDeck FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -192.5 LWC-23 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast LV ASTM D41 or Karnak #108 Asphalt Primer SBS-SA (Optional) SBS-SA SBS-SA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 45 of 75 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-24 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast LV ASTM D41 or Karnak #108 Asphalt Primer SBS-SA (Optional) SBS-SA SBS-SA -232.5 LWC-25 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-26 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5- inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-27 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-28 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5- inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -180.0 HYBRID SYSTEMS: LWC-29 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 46 of 75 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-30 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast QS (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 LWC-31 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast LV (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast LV None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -232.5 LWC-32 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, H- Shield, FlintBoard ISOH FlintFast LV (Optional) Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast LV None SBS-SA-H (Optional) SBS-AA, SBS- TA, APP-TA SBS-AA, SBS-TA, APP-TA -240.0 LWC-33 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H OB500 (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -215.0 LWC-34 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset Board-Max or Polyset CR-20 (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max or Polyset CR-20 None SBS-SA-H (Optional) SBS-AA, SBS- TA or APP-TA SBS-AA, SBS-TA or APP- TA -215.0 CONVENTIONAL SYSTEMS: LWC-35 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast QS Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 47 of 75 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-36 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast QS Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -217.5 LWC-37 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast LV Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast LV None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -240.0 LWC-38 Structural concrete Min. 300 psi, min. 2-inch thick Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture; treated with Celcore PVA Curing Compound and surfaced with Celcore Sanded Bonding Surface (SBS) One or more layer(s), min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO ColdH FlintFast LV Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast LV None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -232.5 LWC-39 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -215.0 LWC-40 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset Board-Max Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -215.0 LWC-41 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5- inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.5-inch Structodek High Density Fiberboard Polyset CR-20 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 48 of 75 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-42 Structural concrete Min. 200 psi, min. 2-inch Celcore Cellular Concrete Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5- inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset CR-20 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 LWC-43 Structural concrete Min. 300 psi Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -215.0 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-44 Structural concrete Min. 200 psi, min. 2- inch Elastizell Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -150.0 LWC-45 Structural concrete Min. 200 psi, min. 2- inch Elastizell Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-46 Structural concrete Min. 200 psi, min. 2- inch Elastizell Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5- inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 LWC-47 Structural concrete Min. 200 psi, min. 2- inch Elastizell Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5- inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -180.0 CONVENTIONAL SYSTEMS: LWC-48 Structural concrete Min. 200 psi, min. 2- inch Elastizell Min. 1.5-inch ACFoam II or FlintBoard ISO. OB500 Min. 0.25-inch DensDeck or DensDeck Prime OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -150.0 LWC-49 Structural concrete Min. 200 psi, min. 2- inch Elastizell Min. 1.5-inch ACFoam II or FlintBoard ISO. OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-TA (Optional) SBS-TA SBS-TA -180.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 49 of 75 TABLE 4B: LIGHTWEIGHT CONCRETE OVER STRUCTURAL CONCRETE DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Base Insulation Layer Coverboard Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Primer Base Ply Ply Cap Ply LWC-50 Structural concrete Min. 200 psi, min. 2- inch Elastizell Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -225.0 LWC-51 Structural concrete Min. 200 psi, min. 2- inch Elastizell Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5- inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.5-inch Structodek High Density Fiberboard Polyset CR-20 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 LWC-52 Structural concrete Min. 200 psi, min. 2- inch Elastizell Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5- inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board or DensDeck or DensDeck Prime Polyset CR-20 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -180.0 COLD APPLIED SYSTEMS: LWC-53 Structural concrete Min. 350 psi, min 2- inch Elastizell with Zell-Crete Fibers. Min. 1.5-inch H-Shield CG OB500, 6-inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. None BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 LWC-54 Structural concrete Min. 350 psi, min 2-inch Range II Elastizell with Zell-Crete Fibers. When walkable, attach LWC with FlintFast #14 and FlintFast 3” Round Plates at 1 per 8 ft2 through to the structural deck. Min. 1.5-inch H-Shield CG OB500, 6-inch o.c. (Optional) Additional layers of base insulation OB500, 6-inch o.c. None BP-CA3 or SBS-CA3 (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 50 of 75 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Vapor Barrier Base Insulation Layer Coverboard Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6&7) Type Attach (Notes 6&7) Base Ply Ply Cap Ply PRE-EXISTENT CELLULAR LWC: SELF-ADHERING SYSTEMS: LWC-55 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch thick, existing (> 28 days old) cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-in. ACFoam II, FlintBoard ISO, H- Shield or FlintBoard H ISO FlintFast QS or FlintFast LV (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-56 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch thick, existing (> 28 days old) cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-in. ACFoam II, FlintBoard ISO, H- Shield or FlintBoard H ISO FlintFast QS or FlintFast LV 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV (Optional) ASTM D41 or Karnak #108 Asphalt Primer SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 CONVENTIONAL SYSTEMS: LWC-57 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch thick, existing (> 28 days old) cellular lightweight concrete, Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-in. ACFoam II, FlintBoard ISO, H- Shield or FlintBoard H ISO FlintFast QS or FlintFast LV 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV (Optional) ASTM D41 or Karnak #108 Asphalt Primer SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-58 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-in. ACFoam II, FlintBoard ISO, H- Shield or FlintBoard H ISO FlintFast QS or FlintFast LV (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 51 of 75 TABLE 4C: LIGHTWEIGHT INSULATING CONCRETE OVER STRUCTURAL CONCRETE DECKS - NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: LWC TO DECK, BONDED VAPOR BARRIER, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) LWIC (Note 14) Vapor Barrier Base Insulation Layer Coverboard Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6&7) Type Attach (Notes 6&7) Base Ply Ply Cap Ply LWC-59 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-in. ACFoam II, FlintBoard ISO, H- Shield or FlintBoard H ISO FlintFast QS or FlintFast LV (Optional) 0.5- in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-60 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-in. ACFoam II, FlintBoard ISO, H- Shield or FlintBoard H ISO FlintFast QS or FlintFast LV 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV (Optional) ASTM D41 or Karnak #108 Asphalt Primer SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 LWC-61 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-in. ACFoam II, FlintBoard ISO, H- Shield or FlintBoard H ISO FlintFast QS or FlintFast LV 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV (Optional) ASTM D41 or Karnak #108 Asphalt Primer SBS-SA-H (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 CONVENTIONAL SYSTEMS: LWC-62 Structural Concrete Min. 420 psi, min. 2-inch Elastizell All Weather/Empire Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-in. ACFoam II, FlintBoard ISO, H- Shield or FlintBoard H ISO FlintFast QS or FlintFast LV 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV (Optional) ASTM D41 or Karnak #108 Asphalt Primer SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 LWC-63 Structural Concrete Min. 420 psi, min. 2-inch Elastizell Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c., 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” One or more layers, min. 2-in. ACFoam II, FlintBoard ISO, H- Shield or FlintBoard H ISO FlintFast QS or FlintFast LV 0.5-in. DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV (Optional) ASTM D41 or Karnak #108 Asphalt Primer SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 52 of 75 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply PRE-EXISTENT CELLULAR LWC: CONVENTIONAL SYSTEMS: CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-64 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" FlintBoard ISO or FlintBoard ISO-T (Optional) Min. 0.25- inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface shall be primed with FlintPrime QD, Karnak #108 or ASTM D41 primer. hot asphalt SBA-SA (Optional) SBS-SA SBS-SA -60.0 HYBRID SYSTEMS: LWC-65 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" FlintBoard ISO or FlintBoard ISO-T (Optional) Min. 0.125-inch STURDY- DEK Asphaltic Cover Board or min. 0.25- inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with ASTM D41 or Karnak #108 Asphalt Primer. hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -60.0 CONVENTIONAL SYSTEMS: LWC-66 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" FlintBoard ISO or FlintBoard ISO-T Min. 0.125-inch STURDY-DEK Asphaltic Cover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board, min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch Fesco Board (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 53 of 75 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply LWC-67 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2-inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" FlintBoard ISO or FlintBoard ISO-T Min. 0.125-inch STURDY-DEK Asphaltic Cover Board or min. 0.25- inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with ASTM D41 or Karnak #108 Asphalt Primer. hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -60.0 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-68 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" FlintBoard ISO or FlintBoard ISO-T (Optional) Min. 0.25- inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface shall be primed with FlintPrime QD, Karnak #108 or ASTM D41 primer. hot asphalt SBA-SA (Optional) SBS-SA SBS-SA -67.5 HYBRID SYSTEMS: LWC-69 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" FlintBoard ISO or FlintBoard ISO-T (Optional) Min. 0.125-inch STURDY- DEK Asphaltic Cover Board or min. 0.25- inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with ASTM D41 or Karnak #108 Asphalt Primer. hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -67.5 CONVENTIONAL SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 54 of 75 TABLE 4D: LIGHTWEIGHT CONCRETE OVER STEEL DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Anchor Sheet Insulation Roof Cover (Note 15) MDP (psf) Deck Treatment Type Surface Treatment Type Fasteners Attach Base Top Attach Base Ply Ply Cap Ply LWC-70 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" FlintBoard ISO or FlintBoard ISO-T Min. 0.125-inch STURDY-DEK Asphaltic Cover Board, min. 0.25-inch DensDeck Prime or SECUROCK Gypsum- Fiber Roof Board, min. 0.5-inch Structodek High Density Fiberboard Roof Insulation or min. 0.75-inch Fesco Board (homogeneous) hot asphalt BP-AA or SBS-AA (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP- TA -67.5 LWC-71 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2-inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM- 90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows Min. 1.5" FlintBoard ISO or FlintBoard ISO-T Min. 0.125-inch STURDY-DEK Asphaltic Cover Board or min. 0.25- inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. Top surface may be optionally primed with ASTM D41 or Karnak #108 Asphalt Primer. hot asphalt SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP- TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 55 of 75 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply PRE-EXISTENT CELLULAR LWIC: SELF-ADHERING SYSTEMS: LWC-72 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic SA NailBase Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 7-inch o.c. at the min. 2-inch lap and 7- inch o.c. in two (2), equally spaced, staggered center rows, Prime stress plates with ASTM D41 primer SBS-SA SBS-SA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 73 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-73 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic SA NailBase Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the min. 2-inch lap and 9- inch o.c. in two (2), equally spaced, staggered center rows, Prime stress plates with ASTM D41 primer SBS-SA SBS-SA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 93 lbf when tested per ANSI/SPRI FX-1 or TAS 105 HYBRID SYSTEMS: LWC-74 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS- TA or APP- TA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-75 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min. 3- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS- TA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-76 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS- TA or APP- TA -75.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105 CONVENTIONAL SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 56 of 75 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-77 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP- TA -60.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 88 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-78 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS- TA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 77 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-79 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min. 3- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Base 20, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP- TA -67.5 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 97 lbf when tested per ANSI/SPRI FX-1 or TAS 105 LWC-80 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min. 2- inch pre-existent cellular lightweight insulating concrete. None Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet Trufast Twin Loc- Nail Assembled Fastener (min. 1.8”) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP- TA -75.0 Note: To qualify the LWIC under this assembly, a 1.8-inch Trufast Twin Loc-Nail Assembled Fastener shall achieve an average withdrawal of 110 lbf when tested per ANSI/SPRI FX-1 or TAS 105 CELCORE (FL2037): SELF-ADHERING SYSTEMS: LWC-81 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound Flintlastic SA NailBase Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA -45.0 HYBRID SYSTEMS: LWC-82 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS- TA or APP- TA -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 57 of 75 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply CONVENTIONAL SYSTEMS: LWC-83 Min. 22 ga., type BV, Grade 40 steel, 6 ft span Celcore S-1 Deck Preparation Min. 470 psi, min. 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture Celcore PVA Curing Compound All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP- TA -45.0 LWC-84 Min. 22 ga., type B steel at max. 5 ft spans structural concrete None Min. 300 psi, min 2- inch Celcore MF Cellular Concrete with Celcore HS Rheology Modifying Admixture. Celcore PVA Curing Compound All Weather/Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 9-inch o.c. at 4-inch laps and 12-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA or SBS-TA SBS-AA or SBS-TA -60.0 LWC-85 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min 2- inch Celcore Cellular Concrete. Celcore PVA Curing Compound Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS- TA or APP- TA -75.0 CONCRECEL (FL5584 & FL10500): CONVENTIONAL SYSTEMS: LWC-86 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete Concrecel Bonding Agent Min. 300 psi, min 2¼- inch Concrecel Concrete. Concrecel Curing Compound Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 3-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA, SBS- TA or APP- TA -52.5 ELASTIZELL (FL4994): SELF-ADHERING SYSTEMS: LWC-87 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None Flintlastic SA NailBase Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA SBS-SA -45.0 HYBRID SYSTEMS: LWC-88 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½- inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS- TA or APP- TA -30.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 58 of 75 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-89 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet or Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS- TA or APP- TA -45.0 LWC-90 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows SBS-SA-H SBS-AA, SBS- TA or APP- TA -45.0 CONVENTIONAL SYSTEMS: LWC-91 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7½-inch o.c. at the 4-inch lap and 7½- inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP- TA -30.0 LWC-92 Min. 26 ga. steel at max 5 ft spans or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Flintlastic APP Base T Trufast FM-90 Base Sheet Fasteners 7½-inch o.c. at the 4-inch lap and 7½- inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -30.0 LWC-93 Min. 22 ga., type BV, Grade 40 steel, 6 ft span None Min. 490 psi, min. 2- inch Elastizell with Zell-Crete Fibers None All Weather/Empire Base Sheet, Glasbase Base Sheet or Flintlastic Base 20 Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the min. 4-inch side laps and 7-inch o.c. at two, equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP- TA -45.0 LWC-94 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners or Trufast Twin Loc-Nail Assembled Fasteners (1.8 inch) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP- TA -45.0 LWC-95 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 200 psi, min 2- inch Elastizell. None Flintlastic APP Base T Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) APP-TA APP-TA -45.0 COLD APPLIED SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 59 of 75 TABLE 4E: LIGHTWEIGHT CONCRETE DECKS OVER STEEL OR STRUCTURAL CONCRETE DECK – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Deck Treatment LWC Surface Treatment Type Fasteners Attach Base Ply Cap Ply LWC-96 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Flintlastic Base 20, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA2 or SBS-CA2 SBS-CA2 -45.0 LWC-97 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Glasbase Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -52.5 LWC-98 Structural concrete None Min. 350 psi, min 2- inch Range II Elastizell with Zell-Crete Fibers. None Glasbase Base Sheet, Flintlastic Poly SMS Base Sheet Trufast FM-90 Base Sheet Fasteners 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-CA3 or SBS-CA3 SBS-CA3 -60.0 MEARLCRETE (FL13492): CONVENTIONAL SYSTEMS: LWC-99 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 250 psi, min 2- inch Mearlcrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA, SBS- TA or APP- TA -45.0 LWC-100 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 250 psi, min 2- inch Mearlcrete. None Flintlastic Poly SMS Base Sheet OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA, SBS- TA or APP- TA -52.5 LWC-101 Min. 22 ga., Type BV, Grade 33 steel, 5 ft span or structural concrete None Min. 300 psi, min 2- inch Mearlcrete. None Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet, Flintlastic Poly SMS Base Sheet OMG CR Base Ply Fasteners (1.7) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows (Optional) BP-AA or SBS-AA SBS-AA, SBS- TA or APP- TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 60 of 75 TABLE 4F: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE E: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Base Sheet Roof Cover (Note 15) MDP (psf) Type Surfacing Base Fasteners Spacing Base Ply Cap Ply PRE-EXISTENT CELLULAR LWC: LWC-102 Min. 22 ga., Type BV, Grade 40 steel Min. 470 psi, Min. 2-inch thick, existing (> 28 days old) cellular lightweight concrete For reroof (tear-off), repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet Trufast Versa Fasteners (min. 2.25”) & Plates, two (2) screws per plate at 180° from each other* 9-inch o.c. within the min. 5-inch wide, heat-welded side laps (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -75.0 Note: *Field withdrawal resistance testing (Note 11) shall yield minimum 322 lbf. Additional Versa-Fast Fasteners within each Versa-Fast Plate may be utilized to produce minimum withdrawal resistance. For recover installations, screws shall be of sufficient length for minimum 2.25” embedment into the existing LWC assembly. TABLE 4G: LIGHTWEIGHT CONCRETE DECKS – REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Note 1) Lightweight Concrete (Note 14) Roof Cover (Note 15) MDP (psf) Type Surfacing Base Ply Cap Ply PRE-EXISTENT CELLULAR LWC: LWC-103 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch thick, existing (> 28 days old) cellular lightweight concrete Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” SBS-CA1 or SBS-CA4 -75.0 LWC-104 Min. 22 ga., Type BV, Grade 40 steel Min. 400 psi, Min. 2- inch thick, existing (> 28 days old) cellular lightweight concrete Repair LWC spalls with Celcore SBS (Sanded Bonding Surface) Flintlastic Ultra Poly SMS Base Sheet applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, ribbons max. 6-inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS or Flintlastic GMS CoolStar, applied in HB Fuller “Millennium Hurricane Force Membrane Adhesive HS”, continuous ribbons maximum 6- inch o.c. 3-inch wide side laps and 6-inch wide end laps are hot-air-welded, torch-welded or sealed with HB Fuller “Millennium Hurricane Force Lap and Flashing Adhesive” -97.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 61 of 75 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: CWF-1. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H- Shield FlintFast QS (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. FlintFast QS FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -60.0 CWF-2. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H- Shield FlintFast QS, 6-inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. FlintFast QS, 6-inch o.c. FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -90.0 CWF-3. Existing Tectum (re- roof only) Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi- Max FA3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -45.0* CWF-4. Existing Tectum (re- roof only) Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi- Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -45.0* CWF-5. Tectum Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra- Max Polyset Board- Max or Polyset CR-20 Min. 0.25-inch DensDeck Polyset Board-Max or Polyset CR-20 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -52.5 CWF-6. Tectum Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra- Max Polyset Board- Max or Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board Polyset Board-Max or Polyset CR-20 None SBS-SA (Optional) SBS-SA SBS-SA -52.5 HYBRID SYSTEMS: CWF-7. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H- Shield FlintFast QS (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. FlintFast QS None SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -60.0 CWF-8. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H- Shield FlintFast QS, 6-inch o.c. (Optional) Additional layer(s) of base insulation and/or min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. FlintFast QS, 6-inch o.c. None SBS-SA-H (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -90.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 62 of 75 TABLE 5A: CEMENTITIOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1&12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply CONVENTIONAL SYSTEMS: CWF-9. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H- Shield FlintFast QS Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -60.0 CWF-10. Tectum Min. 1.5-inch FlintBoard ISO, ACFoam II, FlintBoard H ISO, H- Shield FlintFast QS, 6-inch o.c. Optional additional layers of base insulation, followed by min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board. FlintFast QS, 6-inch o.c. None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -90.0 CWF-11. Existing Tectum (re- roof only) Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi- Max FA3 OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* CWF-12. Existing Tectum (re- roof only) Min. 1.5-inch FlintBoard ISO, ACFoam II, ENRGY 3 or Multi- Max FA3 OB500 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board or DensDeck or DensDeck Prime OB500 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* CWF-13. Tectum Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H, min. 1.3- inch ACFoam III, FlintBoard ISO Cold or min. 1.5-inch Multi-Max FA3, Ultra-Max Polyset Board- Max or Polyset CR-20 Min. 0.5-inch Structodek High Density Fiberboard Polyset CR- 20 None BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 CWF-14. Tectum Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra- Max Polyset Board- Max or Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum- Fiber Roof Board or DensDeck or DensDeck Prime Polyset Board-Max or Polyset CR-20 None BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -52.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 63 of 75 TABLE 5B: CEMENTITIOUS WOOF FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply HYBRID SYSTEMS: CWF-15. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi- Max FA3 hot asphalt (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 CWF-16. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi- Max FA3 hot asphalt (Optional) Min. 0.25- inch SECUROCK Gypsum-Fiber Roof Board hot asphalt SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 CONVENTIONAL SYSTEMS: CWF-17. Existing Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi- Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -60.0 CWF-18. Existing Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi- Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 64 of 75 TABLE 5C: CEMENTITIOUS WOOD FIBER DECKS – REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply CWF-19. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* CWF-20. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 160 lbf) 1 per 1.8 ft2 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* CWF-21. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS-AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* CWF-22. Existing Tectum (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA, SBS-AA, SBS- TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -45.0* TABLE 5D: CEMENTITOUS WOOD FIBER DECKS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) OR REROOF SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: CWF-23. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CWF-24. Tectum Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: CWF-25. Existing Tectum (reroof only) All Weather/Empire Base Sheet Trufast Insuldeck Loc-Nail Base Sheet Fastener (Field W/D > 53 lbf) 9-inch o.c. at the 4-inch lap and 12-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -30.0* CWF-26. Existing Tectum (reroof only) All Weather/Empire Base Sheet Trufast Insuldeck Loc-Nail Base Sheet Fastener (Field W/D > 55 lbf) 7½-inch o.c. at the 4-inch lap and 7½-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA -45.0* CWF-27. Tectum Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -60.0 CWF-28. Tectum Glasbase Base Sheet, Flintlastic Base 20 or All Weather/Empire Base Sheet Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 77 lbf) 7-inch o.c. at the 4-inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 65 of 75 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: G-1. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, ENRGY 3, H- Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-2. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, Multi-Max FA3 FlintFast QS Min. 0.25-inch DensDeck primed with FlintPrime QD, Karnak #108 or ASTM D41 primer FlintFast QS SBS-SA (Optional) SBS-SA SBS-SA -192.5 G-3. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast LV SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-4. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch DensDeck primed with FlintPrime QD, Karnak #108 or ASTM D41 primer OB500 SBS-SA (Optional) SBS-SA SBS-SA -135.0 G-5. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-6. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset Board- Max Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-7. Existing sound gypsum or gypsum plank One or more layer(s), min. 1-inch H-Shield, FlintBoard ISOH, ENRGY 3, ISO 95+GL, min. 1.3-inch ACFoam III, FlintBoard ISO Cold or min. 1.5-inch ACFoam II, FlintBoard ISO, Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 SBS-SA (Optional) SBS-SA SBS-SA -172.5 G-8. Existing sound gypsum or gypsum plank min. 1-inch H-Shield, FlintBoard ISOH, ENRGY 3, ISO 95+GL, min. 1.3-inch ACFoam III, FlintBoard ISO Cold or min. 1.5-inch ACFoam II, FlintBoard ISO, Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch DensDeck primed with FlintPrime QD, Karnak #108 or ASTM D41 primer Polyset CR-20 SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 66 of 75 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-9. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast QS, FlintFast LV, OB500, Polyset Board-Max, Polyset CR-20 (Optional) Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS, FlintFast LV, OB500, Polyset Board-Max, Polyset CR-20 SBS-SA-H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 CONVENTIONAL SYSTEMS: G-10. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH FlintFast QS Min. 0.5-inch Structodek High Density Fiberboard FlintFast QS BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -127.5 G-11. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 G-12. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH FlintFast QS Min. 0.25-inch DensDeck FlintFast QS BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -232.5 G-13. Existing sound gypsum or gypsum plank Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH FlintFast QS Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -202.5 G-14. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast LV BP-AA or SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 G-15. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -120.0 G-16. Existing sound gypsum or gypsum plank Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -135.0 G-17. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 G-18. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset Board- Max Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 67 of 75 TABLE 6A: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply G-19. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch DensDeck or DensDeck Prime Polyset CR-20 SBS-TA (Optional) SBS-TA SBS-TA -180.0 G-20. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.5-inch Structodek High Density Fiberboard Polyset CR-20 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -180.0 G-21. Existing sound gypsum or gypsum plank One or more layer(s), min. 1.5-inch thick ACFoam II, FlintBoard ISO, ACFoam III, FlintBoard ISO Cold, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -187.5 G-22. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -225.0 G-23. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 SBS-TA or APP-TA (Optional) SBS-TA or APP-TA SBS-TA or APP-TA -232.5 G-24. Existing sound gypsum or gypsum plank Min. 1-inch ENRGY 3, H-Shield, FlintBoard ISOH, H-Shield CG, FlintBoard ISO Cold H or min. 1.5-inch Multi-Max FA3, Ultra-Max Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS- TA or APP-TA -240.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 68 of 75 TABLE 6B: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach Type Attach Base Ply Ply Cap Ply HYBRID SYSTEMS: G-25. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi- Max FA3 hot asphalt None N/A SBS-SA- H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 G-26. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi- Max FA3 hot asphalt None N/A SBS-SA- H (Optional) SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -60.0 CONVENTIONAL SYSTEMS: G-27. Existing sound gypsum or gypsum plank All Weather/Empire Base Sheet Trufast FM-75 or FM-90 Base Sheet Fastener or Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4- inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows (Optional) Min. 1.5- inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi- Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -45.0* G-28. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4- inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi- Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -60.0 G-29. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc- Nail Assembled Fastener (Field W/D > 69 lbf) 7-inch o.c. at the 4- inch lap and 7-inch o.c. in two (2), equally spaced, staggered center rows Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 or Multi- Max FA3 hot asphalt Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch Structodek High Density Fiberboard hot asphalt BP-AA or SBS-AA (Optional) BP-AA or SBS-AA SBS-AA, SBS-TA or APP-TA -60.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 69 of 75 TABLE 6C: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer(s) Top Insulation Layer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply G-30. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* G-31. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime OMG Polymer GypTec with 3” GypTec Plate (Field W/D > 160 lbf) 1 per 1.8 ft2 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* G-32. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.5-inch Structodek High Density Fiberboard Roof Insulation Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA or SBS- AA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* G-33. Existing sound gypsum or gypsum plank (Optional) One or more layers, any combination, loose laid Min. 0.25-inch DensDeck or DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board Trufast Twin Loc-Nail Assembled Fasteners (Field W/D > 180 lbf) 1 per 2.0 ft2 BP-AA, SBS- AA, SBS-TA or APP-TA (Optional) BP-AA, SBS-AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -45.0* TABLE 6D: GYPSUM DECKS – REROOF (TEAR-OFF) SYSTEM TYPE E-2: MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Cap Ply SELF-ADHERING SYSTEMS: G-34. Existing sound gypsum or gypsum plank Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 G-35. Existing sound gypsum or gypsum plank Flintlastic SA NailBase Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 88 lbf) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows SBS-SA SBS-SA -60.0 CONVENTIONAL SYSTEMS: G-36. Existing sound gypsum or gypsum plank All Weather/Empire Base Sheet Trufast FM-75 or FM-90 Base Sheet Fastener or Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 18-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA -45.0* G-37. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 80 lbf) 6-inch o.c. at the 4-inch lap and 10-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA, SBS- TA or APP-TA -60.0 G-38. Existing sound gypsum or gypsum plank Glasbase Base Sheet, Flintlastic Base 20, All Weather/Empire Base Sheet Trufast Twin Loc-Nail Assembled Fastener (Field W/D > 100 lbf) 9-inch o.c. at the 4-inch lap and 9-inch o.c. in two (2), equally spaced, staggered center rows BP-AA or SBS- AA SBS-AA, SBS- TA or APP-TA -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 70 of 75 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply SELF-ADHERING SYSTEMS: R-1 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH or Multi- Max FA3 hot asphalt Min. 0.25-inch DensDeck hot asphalt FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-2 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH or Multi- Max FA3 hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA (Optional) SBS-SA SBS-SA -105.0 R-3 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.5-inch ACFoam-HD Coverboard or H-Shield HD FlintFast QS or FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -97.5 R-4 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-5 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, Multi- Max FA3 FlintFast QS or FlintFast LV Min. 0.25-inch DensDeck FlintFast QS or FlintFast LV FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -192.5 R-6 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.5-inch ACFoam-HD Coverboard or H-Shield HD FlintFast QS or FlintFast LV, 6- inch o.c. FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -315.0 R-7 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV, 6- inch o.c. ASTM D41 or Karnak #108 Asphalt Primer SBS-SA (Optional) SBS-SA SBS-SA -315.0 R-8 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch DensDeck OB500 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -120.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 71 of 75 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-9 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA (Optional) SBS-SA SBS-SA -120.0 R-10 Existing fully-bonded smooth- or granule-surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-11 Existing fully-bonded smooth- or granule-surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max Min. 0.25-inch DensDeck Polyset Board- Max FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -192.5 R-12 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 None SBS-SA (Optional) SBS-SA SBS-SA -172.5 R-13 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20 FlintPrime QD, Karnak #108 or ASTM D41 primer SBS-SA (Optional) SBS-SA SBS-SA -192.5 HYBRID SYSTEMS: R-14 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH or Multi- Max FA3 hot asphalt Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board hot asphalt None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -105.0 R-15 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -97.5 R-16 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV (Optional) Additional layer(s) base insulation FlintFast QS or FlintFast LV None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 R-17 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -210.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 72 of 75 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-18 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board or min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV, 6- inch o.c. None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -315.0 R-19 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3 OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -120.0 R-20 Existing fully-bonded smooth- or granule-surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max (Optional) Additional layer(s) base insulation Polyset Board- Max None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 R-21 Existing fully-bonded smooth- or granule-surface asphalt BUR or granule-surface modified bitumen (Optional0 Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -195.0 R-22 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 (Optional) Additional layer(s) base insulation Polyset CR-20 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -222.5 R-23 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 None SBS-SA-H (Optional) SBS-AA, SBS-TA, APP-TA SBS-AA, SBS-TA, APP-TA -217.5 CONVENTIONAL SYSTEMS: R-24 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH or Multi- Max FA3 hot asphalt Min. 0.5-inch Structodek High Density Fiberboard, Min. 0.75-inch FescoBoard (homogeneous) or Min. 0.5- inch DuraBoard (homogeneous) hot asphalt None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 R-25 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH or Multi- Max FA3 hot asphalt 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board hot asphalt None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 73 of 75 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-26 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.5-inch Structodek High Density Fiberboard FlintFast QS or FlintFast LV None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -165.0 R-27 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch DensDeck FlintFast QS or FlintFast LV None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -210.0 R-28 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch DensDeck Prime FlintFast QS or FlintFast LV None BP-AA, SBS-AA, SBS-TA (Optional) BP-AA, SBS- AA or SBS- TA SBS-AA or SBS-TA -210.0 R-29 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 2-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -210.0 R-30 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV, 6- inch o.c. None SBS-AA or SBS-TA (Optional) SBS-AA or SBS-TA SBS-AA or SBS-TA -315.0 R-31 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV, 6- inch o.c. Min. 0.25-inch DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV, 6- inch o.c. None Flintlastic STA or Flintlastic STA Plus (Optional) APP-TA APP-TA -315.0 R-32 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH OB500 Min. 0.5-inch Structodek High Density Fiberboard OB500 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 R-33 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, ENRGY 3, H- Shield, FlintBoard ISOH OB500 Min. 0.25-inch DensDeck, DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board OB500 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -120.0 R-34 Existing fully-bonded smooth- or granule-surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max Min. 0.25-inch DensDeck Polyset Board- Max None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 74 of 75 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-35 Existing fully-bonded smooth- or granule-surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -195.0 R-36 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 Min. 0.5-inch Structodek High Density Fiberboard Polyset CR-20 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -180.0 R-37 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 Min. 0.25-inch DensDeck Polyset CR-20 None BP-AA or SBS-AA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -222.5 R-38 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 None BP-AA, SBS-AA, SBS-TA or APP-TA (Optional) BP-AA, SBS- AA, SBS-TA or APP-TA SBS-AA, SBS-TA or APP-TA -222.5 COLD-APPLIED SYSTEMS: R-39 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV None SBS-CA1 None SBS-CA1 -97.5 R-40 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 1.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.5-inch ACFoam-HD CoverBoard or H-Shield HD FlintFast QS or FlintFast LV None SBS-CA4 None SBS-CA4 -97.5 R-41 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None SBS-CA1 None SBS-CA1 -105.0 R-42 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH FlintFast QS or FlintFast LV Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board FlintFast QS or FlintFast LV None SBS-CA4 None SBS-CA4 -105.0 R-43 Existing fully bonded BUR or modified bitumen roof cover (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH OB500 None SBS-CA1 None SBS-CA1 -82.5 R-44 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA1 None SBS-CA1 -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 3520.03.04-R27 for FL2533-R26 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 27: 07/20/2021 ©2019 NEMO ETC, LLC CertainTeed Flintlastic® Modified Bitumen Roof Systems, (610) 893-5400 Appendix 1, Page 75 of 75 TABLE 7A: RECOVER APPLICATIONS SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Base Insulation Layer Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply R-45 Existing fully bonded, smooth- or granule-surface BUR or modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH OB500 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board OB500 None SBS-CA4 None SBS-CA4 -105.0 R-46 Existing fully-bonded smooth- or granule-surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max Min. 1.5-inch ACFoam III, FlintBoard Iso Cold Polyset Board- Max None SBS-CA1 None SBS-CA1 -82.5 R-47 Existing fully-bonded smooth- or granule-surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max None SBS-CA1 None SBS-CA1 -105.0 R-48 Existing fully-bonded smooth- or granule-surface asphalt BUR or granule-surface modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset Board- Max Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset Board- Max None SBS-CA4 None SBS-CA4 -105.0 R-49 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 Min. 1.5-inch ACFoam III, FlintBoard Iso Cold, H-Shield CG or FlintBoard Iso ColdH Polyset CR-20 None SBS-CA1 None SBS-CA1 -82.5 R-50 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 None SBS-CA1 None SBS-CA1 -105.0 R-51 Existing fully-bonded smooth- or granule-surface asphalt BUR or SBS modified bitumen or granule-surface APP modified bitumen (Optional) Min. 0.5-inch ACFoam II, FlintBoard ISO, H-Shield, FlintBoard ISOH Polyset CR-20 Min. 0.25-inch SECUROCK Gypsum-Fiber Roof Board Polyset CR-20 None SBS-CA4 None SBS-CA4 -105.0 TABLE 7B: RECOVER APPLICATIONS – NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Substrate (Notes 1 & 12) Primer Roof Cover (Note 15) MDP (psf) Base Ply Ply Cap Ply R-52 Existing fully bonded asphalt built-up roof (BUR) over structural concrete deck (Optional) ASTM D41 or Karnak #108 Asphalt Primer SBS-CA1 None SBS-CA1 -187.5