HomeMy WebLinkAbout6103 Fort Pierce Boulevard LBP DSS (1)SCALE: 1/8" = 1'
FRONT ELEVAT ION
SCALE: 1/8" = 1'
RIGHT SIDE ELEVAT ION
PROPOSED UTILITY STRUCTURE
6103 FORT PIERCE BOULEVARD
FORT PIERCE, SAINT LUCIE COUNTY, FLORIDA
NOTE: 12 GA FRAMING
NM
MKB
TB
10/8/2021
NTS
G21001
SHEET 1 OF 3
FIELD:
APPROVED:
SCALE:
CHECKED:
DRAWN:
PROJ. NO.:
DATE:
BECHTOL ENGINEERING
AND TESTING, inc.
Certificate of Authorization No. 00005492
REAR ELEVAT ION
SCALE: 1/8" = 1'SCALE: 1/8" = 1'
LEFT SIDE ELEVAT ION
FRONT WALL AND DOORS RECESSED 10'
SWINGING DOORROLL-UP DOOR ROLL-UP DOOR
ROLL-UP DOOR
PRODUCT CATEGORY
STRUCTURAL COMPONENTS
STRUCTURAL COMPONENTS
EXTERIOR DOORS
EXTERIOR DOORS
EXTERIOR DOORS
MANUFACTURERSUB CATEGORY
ROOF DECK
STRUCTURAL WALL
SWINGING
ROLL-UP
ROLL-UP
CAROLINA CARPORTS, INC.
26 Gauge AG Panel
CAROLINA CARPORTS, INC.
26 Gauge AG Panel
ELIXIR DOOR AND METAL COMPANY
Series 407
CAROLINA CARPORTS, INC.
Steel Roll-Up Sheet Door - 8' Max. Width
CAROLINA CARPORTS, INC.
Steel Roll-Up Sheet Door - 10' Max. W idth
APPROVED PRODUCTS LIST
APPROVAL
No. & DATE
FL6596.1-R6
12/15/20
FL6702.1-R6
12/15/20
FL17996.5-R2
02/28/20
FL16806.2-R5
12/16/20
FL16806.4-R5
12/16/20
METAL FRAMING AND SIDING PREFABRICATED BY
CAROLINA CARPORTS, INC.
P.O. BOX 1263
DOBSON, NORTH CAROLINA 27017
THESE ENGINEERING DRAWINGS ARE THE
PROPERTY OF BECHTOL ENGINEERING &
TESTING, INC. AND CAROLINA CARPORTS, INC.
THESE DRAWING MAY NOT BE REPRODUCED
WITHOUT THE WRITTEN CONSENT OF BECHTOL
ENGINEERING & TESTING, INC., AND CAROLINA
CARPORTS, INC.
THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS
HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL
ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF
SECTION 1609 OF THE FLORIDA BUILDING CODE, SEVENTH EDITION
(2020).
OCCUPANCY GROUP:
CONSTRUCTION TYPE:
RISK CATEGORY:
BUILDING ENCLOSURE TYPE:
WIND EXPOSURE CATEGORY:
ULTIMATE WIND SPEED (MPH):
NOMINAL DESIGN WIND SPEED (MPH):
MEAN ROOF HEIGHT (FEET):
ROOF ANGLE (DEGREES):
INTERNAL PRESSURE COEFFICIENT:
DESIGN PRESSURES (PSF):
ROOF:
ZONE 1:
ZONE 2e:
ZONE 2n:
ZONE 2r:
ZONE 3e:
ZONE 3r:
WALLS:
ZONE 4:
ZONE 5:
SWINGING DOOR:
ROLL-UP DOOR:
U
II-B
I
PARTIALLY
ENCLOSED
C
150
116
13.88
14.0
+0.55 / -0.55
+16.0 / -19.8
+16.0 / -19.8
+16.0 / -29.2
+16.0 / -29.2
+16.0 / -29.2
+16.0 / -44.3
+24.6 / -26.5
+24.6 / -27.6
+28.2 / -31.0
+26.4 / -31.0
THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND
CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL,
INGRESS/EGRESS, PROPERTY SET-BACKS, FINISH FLOOR ELEVAT ION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE
THE RESPONSIBILITY OF OTHERS.
THESE STRUCTURES ARE DESIGNED AS NON-HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY I) CAPABLE OF
SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY
ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS
LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CAROLINA CARPORTS, INC., WHICH EXERT ADDITIONAL LOADS ON THE
STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR
STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS.
ALL STEEL TUBING SHALL BE 50 KSI GALVA NIZED STEEL. ALL FASTENERS SHALL BE GALVA NIZED OR STAINLESS STEEL.
ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS.
ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 3/4" SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP
FRAMING CONNECTIONS SHALL BE WELDED.
CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE
MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6x6 - W1.4xW1.4 WELDED WIRE FABRIC
COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C111 6.
CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LDT 1/2" x 5" OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT 1252, OR SLEEVE
MODEL HSA 1260, OR EQUIVALENT.
POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS.
SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION
R318.1 OF THE FLORIDA BUILDING CODE SEVENTH EDITION (2020) - RESIDENTIAL, AND SECTION 1816.1 OF THE FLORIDA BUILDING
CODE SEVENTH EDITION (2020) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF
IS ASSUMED.
14 GA FRAMING: 2-1/2" x 2-1/2" TUBE STEEL (TS) WITH 2-1/4" x 2-1/4" TS NIPPLES.
12 GA FRAMING: 2-1/4" x 2-1/4" TS WITH 2" x 2" TS NIPPLES.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
GENERAL NOTES:
signed and sealed, and the signature must be verified on any electronic copies.
on the date indicated here. Printed copies of this document are not considered
This item has been digitally signed and sealed by Love B. Patel, P.E.
605 WEST NEW YORK AV ENUE
BECHTOL ENGINEERING AND TESTING, INC.
Love B. Patel, P.E., State of Florida, Professional Engineer, License No. 90753
Senior Engineer
Love B. Patel, P.E.
DELAND, FLORIDA 32720
26 GA. GALVA NIZED METAL ROOF PANELS
FASTENED TO PURLINS ACCORDING TO
MANUFACTURER'S INSTALLATION INSTRUCTIONS
24" 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 3/4" SDF's AT
EACH END (4 PER BRACE)
24'
TYPICAL INTERIOR RAFTER/POST FRAME SECTION
3
2
1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO
EACH RAFTER WITH (2) #12-14 x 3/4" SELF-DRILLING
FASTENER SPACED NOT MORE THAN 48" O.C.
LEFT SIDE RAFTER/POST FRAMING PLAN
SCALE: 1/8" = 1'
SCALE: 1/8" = 1'
3
1
26 GA. GALVANIZED METAL WALL PANELS
FASTENED TO POSTS ACCORDING TO
MANUFACTURER'S INSTALLATION INSTRUCTIONS
12
3
6"
5'
Maximum
3
3
NM
MKB
TB
NTS
SHEET 2 OF 3
FIELD:
APPROVED:
SCALE:
CHECKED:
DRAWN:
PROJ. NO.:
DATE:
BECHTOL ENGINEERING
AND TESTING, inc.
Certificate of Authorization No. 00005492
10'
REAR END WALL RAFTER/POST FRAMING PLAN
SCALE: 1/8" = 1'
RIGHT SIDE RAFTER/POST FRAMING PLAN
SCALE: 1/8" = 1'
10/8/2021
G21001
RECESSED FRONT WALL RAFTER/POST FRAMING PLAN
SCALE: 1/8" = 1'
1
3
5'
Maximum
5
3 3
8
3
7
2'9'
8'
6
3 3
4
FRONT WALL
30' ENCLOSED 10' OPEN
3'
2'
6'-8"
11
3
3
9
3
1
8'8'
3
5 8
3
6
3
8'
8'
4
3
3
7
5'
Maximum
8'
2'9'
30' ENCLOSED
5'
Maximum
10' OPEN
6"
FRONT WALL
3
3
10'23'40'
PROPOSED UTILITY STRUCTURE
6103 FORT PIERCE BOULEVARD
FORT PIERCE, SAINT LUCIE COUNTY, FLORIDA
signed and sealed, and the signature must be verified on any electronic copies.
on the date indicated here. Printed copies of this document are not considered
This item has been digitally signed and sealed by Love B. Patel, P.E.
605 WEST NEW YORK AV ENUE
BECHTOL ENGINEERING AND TESTING, INC.
Love B. Patel, P.E., State of Florida, Professional Engineer, License No. 90753
Senior Engineer
Love B. Patel, P.E.
DELAND, FLORIDA 32720
3
1
3
1
3
8
3
4
4'
10"
10
3
NM
MKB
TB
NTS
SHEET 3 OF 3
FIELD:
APPROVED:
SCALE:
CHECKED:
DRAWN:
PROJ. NO.:
DATE:
BECHTOL ENGINEERING
AND TESTING, inc.
Certificate of Authorization No. 00005492
10/8/2021
G21001
PROPOSED UTILITY STRUCTURE
6103 FORT PIERCE BOULEVARD
FORT PIERCE, SAINT LUCIE COUNTY, FLORIDA
signed and sealed, and the signature must be verified on any electronic copies.
on the date indicated here. Printed copies of this document are not considered
This item has been digitally signed and sealed by Love B. Patel, P.E.
605 WEST NEW YORK AV ENUE
BECHTOL ENGINEERING AND TESTING, INC.
Love B. Patel, P.E., State of Florida, Professional Engineer, License No. 90753
Senior Engineer
Love B. Patel, P.E.
DELAND, FLORIDA 32720
TS BASE RAIL
6" LONG TS NIPPLE
SECURE EACH WITH
(4) #12-14 x 3/4"
SELF-DRILLING FASTENERS
RAFTER POST/BASE
BASE RAIL CONNECTION DETAILRAFTER POST/DBL. HEADER DETAIL
12 GA TS POST
9 Not To Scale
RAFTER POST/HEADER DETAIL10Not To Scale 11 Not To Scale
12 GA DOUBLE TS HEADER
3/16"
DBL. HDR.
NIPPLE TO
BASE RAIL
3/16"NIPPLE TO
6" LONG TS NIPPLE
SECURE EACH WITH (4) #12-14 x 3/4"
SELF-DRILLING FASTENERS
3/16"NIPPLE TO
DBL. HDR.TS RAFTER POST
6" LONG TS NIPPLE
SECURE WITH (4) #12-14 x 3/4"
SELF-DRILLING FASTENERS1/8"
12 GA TS POST
NON-STRUCTURAL HEADER CONN. DETAIL
2"x2"x2" 16 GA ANGLE CLIP
SECURE TO POST (EACH SIDE)
AND RAFTER CHORD/RAIL WITH
(4) #12-14 x 3/4" SDF's, (2) ON
TOP OR BOTTOM, (2) ON SIDE
2"x2"x2" 16 GA ANGLE CLIP
SECURE TO POST AND
RAFTER WITH (4) #12-14 x 3/4"
SDF's, (2) ON BOTTOM,
(2) ON SIDE
OR
TS RAFTER
6" LONG TS NIPPLE
SECURE POST TO NIPPLE WITH
(4) #12-14 x 3/4" SDF's
BOX EAVE RAFTER/POST DETAIL
TS POST
(12 GA IF ROLL-UP DOOR FRAME)
TS WINDOW RAIL OR GIRT
FOR VERTICAL SIDING OPTION
2" x 2" x 2" 16 GA ANGLE CLIP
SECURE TO POST AND TOP OF
HEADER, OR BOTTOM OF WINDOW
RAIL/GIRT WITH (4) #12-14 x 3/4" SDF's
(2) ON TOP OR BOTTOM, (2) ON SIDE
TS NON-STRUCTURAL HEADER
(12 GA IF ROLL-UP DOOR FRAME)
RAIL, OR GIRT TO POST CONN. DETAIL
NON-STRUCTURAL HEADER, W INDOW
6 Not To Scale
2 Not To Scale
TS RAFTER POST
6"
24" 16 GA U-CHANNEL BRACE (5' TO 7' POST)
48" 16 GA U-CHANNEL BRACE (8' TO 14' POST)
BRACE ANGLE SHALL BE MIN. ±45°
RAFTER
NIPPLE TO 3/16"
END POST/RAFTER CONN. DETAIL
2"x4" 16 GA PLATE
SECURE TO EACH SIDE OF
POST/RAFTER CONNECTION
WITH (4) #12-14 x 3/4" SDF's,
(2) ON POST, (2) ON RAFTER
Not To Scale7
TS END POST
TS BASE/WINDOW RAIL OR
NON-STRUCTURAL HEADER
(12 GA IF ROLL-UP DOOR FRAME)
POST TO RAIL, TRUSS CHORD, OR
4 Not To Scale
TS TRUSSED RAFTER CHORD,
OR NON-STRUCTURAL HEADER
TS END POST OR DOOR/
WINDOW FRAME POST
2" MINIMUM4" MINIMUM
12"
MONOLITHIC CONC. FOOTING (2500 PSI MIN.)
REINFORCED WITH 2 #5's CONTINUOUS
CONCRETE BASE RAIL A NCHORAGE
Not To Scale1
12"
MINIMUM 2-1/2" EMBEDMENT
INSTALL 1/2" x MINIMUM 5" TAPCON REDHEAD LDT
ANCHOR OR 1/2" x MINIMUM 5-1/2" EXPANSION
ANCHOR THROUGH BASE RAIL WITHIN 6" OF EACH
RAFTER POSTS ALONG SIDES AND EVERY END
WALL POST ALONG END WALL SECTIONS
TS BASE RAIL
FRAMEOUT/ ROLL UP
POST / BASE RAIL CONN. DETAIL8Not To Scale
BASE RAIL
3/16"NIPPLE TO
6" LONG TS NIPPLE
SECURE EACH WITH (4) #12-14 x 3/4"
SELF-DRILLING FASTENERS
12 GA TS POST
TS CONTINUOUS BASE RAIL
POST/BASE RAIL CONN. DETAIL
Not To Scale3
NIPPLE TO
BASE RAIL
6" LONG TS NIPPLE
SECURE POST TO NIPPLE
WITH (4) #12-14 x 3/4" SDF's
TS RAFTER POST
3/16"
1-1/2" x 1-1/2" x 2" 16 GA CLIP
ANGLE SECURE TO
POST AND BASE RAIL
WITH (4) #12-14 x 3/4" SDF's,
(2) ON TOP, (2) ON SIDE
END POST/BASE RAIL CONN. 5 Not To Scale
TS CONTINUOUS BASE RAIL
TS RAFTER POST
6" LONG TS NIPPLE
SECURE POST TO NIPPLE
WITH (4) #12-14 x 3/4" SDF's