HomeMy WebLinkAboutREVISION Application For Building PermitOFFICE USE ONLY:
DATE FILED: 1/6/2022 PERMIT # SLCQV2=,,,
REVISION FEE: RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
Z300. VIRGINIA AVENUE
FORT PIERCE; FL 34982-5652
(772) 462-1553
APPLICATION FOR BUILDING PERMIT REVISIONS
. PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
1950 Cortez Blvd, Fort Pierce, FL
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
#3 on floor plan changing product from casement to double hung attached new floor plan & window & door opening info
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CRC046091
BUSINESS NAME: Storm Tight Windows
QUALIFIERS NAME: Alphonse Campanelli
ADDRESS: 500 SW 12th AVE
CITY: Deerfield Beach STATE: FL
PHONE (DAYTIME): 561-420-0271
OWNER/BUILDER INFORMATION:
NAME: Shirley Goldberg
ADDRESS:1950 Cortez Blvd
CITY: Fort Pierce
PHONE (DAYTIME: 7725790714
STATE: FL
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
SLCCC: 9123109.
Revised 06130117
STATE:
FILE COPY
ST. LUCIE CO CERT. #:
frw
FAX:
ZIP: 33442
ZIP: 34982
ZIP:
- FAX:
Opening
I Size
(WxH)
1. 20-1103.04
11.0 x 49
(SLIDE - PIC - SLIDE)
2. 20-1103.09
52 x37
(HORIZONTAL SLIDER)
3. 20-1103.08
36 x37
(DOUBLE HUNG)
4. 20-1103.08
26 x37
(DOUBLE HUNG)
5. 20-1103.08
36 x37
(DOUBLE HUNG)
6. 20-1103.09 '
52 x37
(HORIZONTAL SLIDER)
7. 20-1103.07,
36 x37
(CASEMEN7)
B. 20-1103.07
36 x37
(CASEMEN7)
9. 20-1103.09
52 x37
(HORIZONTAL SLIDER)
10. 20-1103.09 ,
73 x 49
(HORIZONTAL SLIDER)
***REVISION***
Change product
opening # 3
MRH 121
59'
5uriilwied
�4undo 913ni •19
ZZOZ ®1 W
a3nr30.3a
FILE COPY
no
rn
Co
g
m
>d
J Ch
J
N LL
o
ww
U
}
O W
30"90"
W
Ua
J
U)
_
�o
NOT TO SCALE
oATe
Jan 03 2022
PAGE �E9LPIPTION:
Site Plan
1
WINDOW &. DOOR OPENING INFORMATION
A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
n r »: f t- ...e. 7- _ 1n0/ of lemct hnri7nntal rtim-inn nr do.0/ of the mean mnf heinht whichever is smaller. but not less than 4% of least horizontal dimension or 3 ft.
OPENING
LOCATION
NUMBER
(Location)
Corner Zone
or Interior
IS THIS A
WINDOW
OR DOOR
GLAZING
TYPE
PRODUCT
ACCEPTANCE
NUMBER
PRODUCT APPROVAL
APPROVED PRESSURE RATING
REQUIRED OPENING
DESIGN PRESSURE
MAXIMU
M
TESTED
SIZE
ROUGH
OPENING
DIMENSIONS
MULTIPLE
WINDOW
ARE
SHUTTERS
REQ Y/N
(+) PSF
(-) PSF
+ PSF
()
- PSF
( )
MULLION
REQ YIN/NA
1
Int
Window
7/8" Lami
20-1103.04
55
55
34.6
-37.8
111 x 63
110x49
No
No
2
Int
Window
7/8" Lami
20-1103.09
55
55
37.1
-40.3
74 x 63
5207
No
No
nOW
Int
Window
7/8" Lami
20-1103.08
55
55
37.8
-41.0
53 x 77
36x37
No
No
4
Int
Window
7/8" Lami
20-1103.08
55
55
37.8
-41.0 1
53 x 77
2607
No
No
5
Int
window
7/8" Lami
20-1103.08
55
55
37.8
-41.0
53 x 77
3607
No
No
6
Int
window
7/8" Lami
20-1103.09
55
55
37.1
-40.3
74 x 63
5207
No
No
7
Int
window
7/8" Lami
20-1103.07
55
55
37.8
-41.0
36 x 68
3607
No
No
8
Int
Window
7/8" Lami
20-1103.07
55
55
37.8
-41.0
36 x 68
3607
No
No
9
End
window
7/8" Lami
20-1103.09
55
55
37.1
-49.2
74 x 63
5207
No
No
10
Int
window
7/8" Lami
20-1103.09
55
55
35.6
-38.8
74 x 63
73x49
No
No