Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL - ENGINEERINGMORTISE LOCKSET WITH OR WITHOUT DEADBOLT j--MAXIMUM UNIT WIDTH =40" Lo i m O i3 z 2 O A. L W 13 oo MAX. DLO WIDTH -'4" SEE NOTE 7. � x❑ I 36" MAXIMUM DOOR OPENING WIDTH OMERE WATER WHENEWATER DESIGN PRESSURE RATING, PSF INFILTRATION INFILTRATION 17 REQUIREMENT REQUIREMENT IS NEEDED ISN'T NEEDED 1 SEE SHEETS SEE SHEET6 ±75 175 RIM EXIT DEVICE [—MAXIMUM UNIT WIDTH =40" THREE-POINT LATCHING CYLINDRICAL LOCKSET 1/2" MIN. THROW SURFACE VERTICAL ROD CONCEALED VERTICAL ROD EXIT DEVICE LATCH EXIT DEVICE EXIT DEVICE �I MAXIMUM UNIT WIDTH —MWIDTHMUNIT 40" [—MAXIMUMUNIT 40" ---1 [—MAXIMUMUNIT 40" THREE-POINT LATCHING EXIT DEVICE '—MAXIMUM UNIT WIDTH =40" H r Z xU-' F Z ----- Z __—__ F 2 W Z LD w slEo EO�s• - Asx ~ z r —iT O W o a w o W❑ d o a O j OAi-i I Z O Ale A3 Of 1 tt A3 Ad~ ❑ 0 W D: T5 0 W ao' 13 Otn O O 13 o w J O N O o w otn 0 O 130 w oW ❑w 00 X ❑ X Q ❑ ❑ x 6 M I MAX. DLO xx x ��x Q j j j I MAX. DLO ] I WIDTH =24"- Q Q I WIDTH =24' SEE NO E 7. SEE NOTE 7. x Q 1 I I m MAX. DLO WIDTH = z4^ SEE NOTE ]. UM MAXIMUM DOOR OPENING WIDTH O DESIGN PRESSURE RATING. PSF INFILTRATION INFILTRATION 4l WHERE WATER WHERE WATER REQUIREMENT REQUIREMENT IS NEEDED ISNOTNEEDED 2 SEE SHEETS SEE SHEETfi ±75 ±75 RIM EXIT DEVICE MAXIMUM UNIT WIDTH =5 W O i z O-' W r MAX. DLO z Z __—__ n 3 WIDTH=34. _ W F F D:1 10 O 7. SEE NOTE 7. O Al _ W 13 Tx Z 00 a0 W 7 00 ❑ ❑ O MAX. DLO ❑ X M WIDTH = 24' SEEOTE 7. 1 36" MAXIMUM DOOR OPENING WIDTH O DESIGN PRESSURE RATING. PSF INFLTRATION INFILTRATION � REQUIREMENT REQUIREMENT IS NEEDED IS NOT NEEDED 3 SEE SHEETS SEE SHEET6 ±60 ±60 RIM EXIT DEVICE MAX. DLO WIDTH = 12' 1 ={A SEENOTE7. Ja c7 0 i w i T. O 0 z A O 13 K O ❑ 36" MAXIMUM DOOR OPENING WIDTH DESIGN PRESSURE RATING, PSF 0 WHERE WATER WHERE WATE INFILTRATION INFILTRATION Gi REQUIREMEHT REQUIREMENT IS NEE'ED IS NOT NEEDED 4 SEESHEETS SEE SHEET6 t60 ±60 RIM EXIT DEVICE Qw FZ �Zy O WIDTH =4" SEE NOTE 7. '—MAXIM MDOORJ l---MAXIM48" 48"UM DOOR --I 1^MAXIMUM DOOR �-I-�MAXIMUMDOOR—I OPENING WIDTH OPENING WIDTH OPENING WIDTH OPENING WIDTH l) DESIGN PRESSURE RATING, PSF 1 DESIGN RESS RERAT1NG,PSFI 1 O JOESIGNPRESSURE RATING, PSF Z WHERE WATER WHERE WATER Z WHERE WATER WHERE WATER Z WHERE WATER WHERE WATER Z WHERE WATER WHERE WATER TI INFILTRATION INFILTRATM)N Ti INFILTRATION INFILTRATION T1 INFILTRATION INFILTRATION w INFILTRATION INFILTRATION REQUIREMENT REQUIREMENT REQUIREMENT REQUIREMENT REQUIREMENT REQUIREMENT REQUIREMENT REQUIREMENT 7 6EESHEETDS SNEESHEETBDEEDE 6 SEE SHEEISNEEDET 'SEE SHEET 9 SEE SNEET5 ISEESXEET BD 9 SEESHEETNEEDED5 IEEE SHEET 6S NOT D ±60 ±60 ±50 1 ±50 ±75 ±100 175 ±100 COMPLIANCE STATEMENT: 1. THESE PRODUCTS HAVE BEEN TESTED TO HVHZ PROTOCOLS TAS 201, 202 & 203-94, ASTM PROTOCOLS E283-04, E330-02 AND E331-00, AND COMPLY WITH CURRENT EDITION FLORIDA BUILDING CODE. NOTES: 1. INTERIOR VIEWS ARE SHOWN FOR ALL ELEVATIONS OF OUTSWING DOOR 2. SEE TABLE 1 ON SHEET 2 FOR GLAZING SIZE, HARDWARE APPLICATIONS AND LIMITATIONS 3. SEE SHEET 3 AND 16 FOR HINGE REQUIREMENTS 4. SEE SHEET 4 FOR ANCHORING TYPES AND LIMITATIONS AND SHEET 5 & 6 FOR SILL WEATHERING INSTALLATION 5. SEE SHEET 5 TABLES 3.1 AND 3.2 FOR WATER RATED THRESHOLD AND WEATHERSTRIPPING INSTALLATION AND LIMITATIONS 6. SEE SHEET 6 TABLES 4.1 AND 4.2 FOR NON WATER RATED THRESHOLD AND WEATHERSTRIPPING INSTALLATION AND LIMITATIONS 7. SEE SHEET 9 FOR GLAZING OPTIONS AND DETAILS 8. DLO - DAYLIGHT OPENING SIZE, SAME AS EXPOSED GLASS. SEE SHEETS 1, 2,8 AND 9 FOR LIMITATIONS 9. ALL CONFIGURATIONS MEET LARGE AND SMALL MISSILE IMPACT REQUIREMENTS- LARGE MISSILE IMPACT (50 F/S) 2 iz Aso W X0W MAX. DLO WIDTH = 24' SEE NOTE 7. R E V I S I❑ N S DESCRIPTION DATE APPROVED APPROVAL DWG YMF 05/20/07 REVISED DWG YMF 01/04/10 REVISED NAME JPD 04/09/10 REVISED DWG JPD 11/01/13 REVISED DWG JPD 02/01/15 REVISED DWG JPD 06/30/15 ENGINEER CHANGE LMS 12/01/16 REVISED DWG JPD 07/18/18 LOCK UPDATE YC 11/26/19 CYLINDRICAL LOCKSET 1/2" MIN. THROW LATCH [__�MAXIMUM DOOR J '`MAXIMUM DOOR+' r OPENING WIDTH OPENING WIDTH 1j O DESIGN PRESSURE RATING, PSF O WHERE WATER WHERE WATER I INFILTRATION INFILTRATION D DESIGN PRESSURE RATING, PSF O wx[aE wwTER WHERE WATER r INFILTRATION INFILTRATION 2 Z � 5 REQUIREMENT REQUIREMENT IS NEEDED IS NOT NEEDED S SEE SHEETS SEE SHEET6 � REQUIREMENT REQUIREMENT IS NEEDED IS NOT NEEDED 6 SEE SHEETS SEE SHEET6 Z W O ±50 ±50 ±60 ±60 0 EXIT ALARM EXIT ALARM MORTISE LOCKSET WITH OR WITHOUT g� WIDTH=34025" LOCK MAX. DLO LOCK DEADBOLT � � SEE NOTE 7. 6-w WIDTH =1r r� Tr SEE NOTE 7. _ OPENING WIDTH QDESIGN PRESSURE RATIND, PSF 2 WHERE WATER WHERE WATER INFILTRATION INFILTRATION 41 REQUIREMENT REQUIREMENT IS NEEDED IS NOT NEEOEO 0; SEE SHEET SEE SXEETB Z w O i O Quo F Z F wLl w w r 5-11 48" MAXIMUM DOOR c7 ~O OPENING WIDTH MAX. DLO O 2 ZIoIDESKINPRESSURE RATING, PSI _ _ _ _ _ MAX. DLO WIDTH=34.11" SEE NOTE 7. WIDTH=4" S­NOTF 7. 0 O ❑ TT- O W Z WHEREWATER WHEREWATEF ❑ to w INFILTRATION INFILTRATION TT- 61 NES NEEDED SNOTN MEET IS NEEDED IS NOT NEEDE[ � 2 SEE SHEET6 SEE SHEET6 ±50..±50 `TT 48" MAXIMUM DOOR OPENING WIDTH (� DESIGN PRESSURE RATING, PSF Z WHERE WATER INFILTRATION WHERE WATER INFILTRATION G1 REQUIREMENT REQUIREMENT 16 ISNEEDED SEE SHEET ISNOTNEEDED SE —Es HEET6 ±55 ±55 Ti 48" -MAXIMUM DOOR OPENING WIDTH DESIGN PRESSURE RATING NHEREWATER WHEREIN INFILTRATION I INFILTR4 zM SJOAKOF V: z BEND RADIUS SCHLAGE LOCK COMPANY, LLC Digitally signed by Hermes F Norero 11819 N. PENNSYLVANIA STREET Reason: I am approving this document CARMEL, IN 46032 Date: 2019.12.16 17:35:55 -05'00' -�- THIRD ANGLE PROJECTION TITLE: STEELCRAFT H SERIES SINGLE OUTSWING GLAZED COMMERCIAL STEEL DOORS WITH AND WITHOUT PANIC EXIT DEVICES SWN DATE YMF 05/E0/07 GLASS OUTSWING DOORS AND HARDWARE CONFIGURATIONS COMMERCIAL DOOR OPENING SINGLE GLASS DOORS. -CKED 'ROVED SIZE FLAT DWG N0. REV IRGS07 ❑ �. APPVL JPD 11/15/07 SCALE' NTS I AUT❑CAD ISHEET 1 of 16 Maximum Dealgn Pressure, Maximum Door Maximum DLO St.., Door PSF Opening Size, In. In. (NOTE 3) Locking Hartlware Descrip0on Comments Configuretion positive Nsgati— Width Height Width Height Hard mil fe Model/SaHss Strike Models Brand VLV9400, AD -MD, Function with deadbolt. 3/4" min. throw latch 8 CO -MD 1" min*throw bolt ULV9000, AD -MD, Function wlo deadbolt, CO -MD 10-072 SCNage 3/4" —,. throw latch 1 75 75 36 84 24 64 Modise Lock LE-MS, LE -MS, LEB-MS Function with or w/o deadbolt, W4" min. LEB-MB th latch & 1" row min. LE-M D, LE -MD throw h,it (if applicable) Function with or w/o M/MA ANSI Falcon deadbolt, 3/4" in. throw latch & 1" min. throw bolt (if applicable) D, ND, NDE, NDEB, AD-CY, COCY 1P025 1/2" min throw latch SCNage 2 71 75 36 64 24 84 Cylintlncal Lock qLX ANSI 1/2" min throw latch (13-24], 14 28) T ANSI Falcon 1/2" min throw latch 981992] & 981992]-F 299-F,499-F Top, W4L, Bottom Von Dupdn 9 60 60 36 B4 24 64 Surtace Vertical Rod Exit Device F-25-V 8 25-V 3788 Top, 2130130 Bottom Falcon .1).7-1 & HH98/994] 338 Tep, 304E or 385A Bottom Von Dupdn HH981994] deNces have a 23 4" hackeet Concealed 33/3547A -F & HH33/354]A Tap, 338 S.W. 304E or 385A Von Dupdn HH33/354]A devices have a 2-3/4" backset 4 60 60 3s eA 24 64 Vertical Rod Exit Device F-25-C 418& Tep' Falcon 2130 Bottom Three-point 299-F,493FTop/Middle, 5 50 50 48 96 34.25 74.1 Latching Device 9W/ 57 & 9WW57-F 3041-, Bottom Von Dupdn 6 60 60 36 84 24 64 Threa-Pain[ 8 98/996]-F 299-F,499-F Tnp/Middie, Von Dupdn Latching Device 3.!- 304E Bottom 9S199 & 98/99 F 299-F,499-F Von Dupdn ] fi0 60 36 84 24 64 Rim Exit DeNce W-F 268/468 Von Dupdn 9W99 & 9&W-F 299-F,499-F Von Dupdn 8 50 50 48 96 34.25 74.5 Rim Exit DeNce W-F 26W468 Von Dupnn 9 12 12 75/ 75/ 96 3 33 Rim Exit DeNce XP98/99 & XP98/99-F 909/954 Von Dupdn gA SEE NOTE 2. SEE NOTE 2. 4 25 5 20 10 55 55 48 96 12 12 Exit Alarm Lock 28]0 Guard-X 281 Von Dupdn 3 33 10A 4 25 5 20 ULV8400, D, Function with deadbolt, ,in. throw latch & CO -MD 1" min. throw bolt ULV9W0, AD -MS, Function w/o deadbolt, CO -MS 10-072 Schlep. 3/4" min. throw latch LE -MS, LEB-MS Function with or w/o deadbolt, ,l4 min. 11 50 50 48 96 34.25 74.5 Modise Lock LE-MB, LEB-MB [hmw latch & 1" min. LE-M D. LE -MD throw bolt (if applicable) M/MA ANSI Falcon Function with or w/o deadbolt, " " min. throw latch & 1" min. throw bolt (if applicable) D, ND, NDE, NDEB, AD-CY,CO-CV 1P025 ur min throw latch 12 50 50 48 96 34.25 74.5 Cyiinddcal Lock SCNage 1/(1 min throw latch qLX ANSI (13-24], 1zi.t T ANSI Falcon 1/2" min throw latch TABLE 1. NOTES: 1. SEE SHEETS 10, 11 & 12 FOR LOCKING HARDWARE. 2. DOOR CONFIGURATIONS 9 AND 9AARE RATED FOR MAXIMUM DESIGN PRESSURE UP TO ±75 PSF WITH ZERO INT'L THRESHOLD 12A OR FOR DOOR OPENINGS UP TO 3'-0" X 7'-0" WITH NGP THRESHOLD 12B AND ±50 PSF FOR DOOR OPENINGS UP TO 4'-0" X 8'-0" WITH NGP THRESHOLD 12B WHEN WATER INFILTRATION REQUIREMENT IS NEEDED. SEE SHEET 5 2.1 DOOR CONFIGURATIONS 9 AND 9A ARE RATED FOR A MAXIMUM DESIGN PRESSURE UP TO ±75PSF WITH ZERO INT'L THRESHOLD OPTIONS AND UP TO ±100 PSF WITH NGP THRESHOLD OPTIONS WHEN WATER INFILTRATION REQUIREMENT IS NOT NEEDED. SEE SHEET 6 3. DLO - DAYLIGHT OPENING, SAME AS EXPOSED GLASS. SEE SHEETS 1, 2,8 & 9 FOR GLAZING TYPES, DETAILS AND LIMITATIONS. LTR DESCRIPTION DATE APPROVED A APPROVAL DWG YMF 05/20/07 G REVISED DWG YMF 01/04/10 H REVISED NAME JPD 04/09/10 J REVISED DWG JPD 11/01/13 K REVISED DWG JPD 02/01/15 L REVISED DWG JPD 06/30/15 M ENGINEER CHANGE LMS 12/01/16 N REVISED DWG JPD 07/18/18 0 LOCK UPDATE YC 11/26/19 MM SJAX OF r: BEND RA➢IUS SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 -�- THIRD ANGLE PROJECTION TITLE: STEELCRAFT H SERIES SINGLE OUTSWING GLAZED COMMERCIAL STEEL DO WITHOUT PANIC EXIT DEVICES SWN DATE YMF 9v211/07 GLASS OUTSWING DOORS AND HARDWARE CONFIGURATIONS DOOR OPENING SINGLE GLASS DOORS. -CKED ICOMMERCIAL I G. AlPVL RGS07 Io JPD 111-1.7 SCALE' NTS I AUT❑CAD ISHEET 2 Df 16 NOTES: p 1 SEE SHTS 5 & 6 EXTERIOR 1. ANCHOR REQUIREMENTS: 1�SEE SHTS 5 & 61/a' x SEE SHEET 4 FOR APPROVED ANCHORS AND INSTALLATION. / TAPI 2. HINGE REQUIREMENTS: 4.5" STD WT. MIN. / 1/4" X 1-3/4" ;ta x wSOE FOR DOOR OPENING UP TO 90" HIGH - MIN (3) HINGES TAPCON FOR DOOR OPENING OVER 90" - 96' HIGH - MIN (4) HINGES OR 1.25" MIN. E.D. STD LOCATIONS: 9.75" FROM RABBET IN HEAD TO CL OF TOP HINGE #14 X 1-3/4" WOOD (SG-.55) 10,38" FROM FLOOR TO CL OF BOTTOM HINGE, EQUALLY SPACED WOOD SORE E.D. 2.5" E.D. CONCRETE IN BETWEEN. HINGE LOCATIONS MAY VARY, MAX SPACING DO NOT EXCEED 35.5" FOR 3 HINGES. SEE SHEET i6 FOR APPROVED CONTINUOUS HINGE MODELS. 1.25 MIN. (3 KSI MIN.) 3. SEE SHEETS 1, 2, 3 & 7 FOR AVAILABLE STANDARD OPENING SIZES AND SPECIFICATIONS. EMBEDMENT DETAIL 'TH' SIDEVIEW ( )- 4. HARDWARE INSTALLATION AS PER MANUFACTURER'S INSTRUCTIONS. TYPICAL SILL DETAIL 5. 4" FACE FRAME HEAD IS AVAILABLE. SEE SHEET 4. WOOD OR CONCRETE SILL 6. APPLY CAULK TO FULL LENGTH OF SILL AND ENTIRE PERIMETER OF FRAME. SEE SHEETS 5 & 6 E.D.= EDGE DISTANCE 7. WEATHERSTRIPPING: - WHEN WATER INFILTRATION IS REQUIRED INSTALL PER SHEET 5. (ZERO INTL 566 VS NGP 950) - WHEN WATER INFILTRATION IS NOT REQUIRED - INSTALL PER SHEET 6. (ZERO INTL 566, 65 & 568 VS NGP 950) 8. SEE SHEET 13 FOR HORIZONTAL CROSS -SECTIONS, SEE SHEET 14 FOR VERTICAL CROSS -SECTIONS. 9. INSTALL REINFORCEMENT CHANNELS AROUND EACH UTE-CUTOUT. 10. ELECTRICAL INSTALLATION AND FIRE RATINGS ARE UNDER SEPARATE APPROVAL AND MUST BE REVIEWED BY CORRESPONDING AUTHORITY. 11. OPTIONAL POWER TRANSFERS, AND/OR "SIGNAL SWITCH" MAY BE USED AS ALLOWED BY CODE AND IT DOES NOT EFFECT THE MECHANICAL PROPERTIES OF EXIT DEVICE AND/OR INHIBIT EGRESS. TO BE REVIEWED BY BUILDING OFFICIAL CL OF__.. 12. TYPICAL SILL INSTALLATION SHALL BE ANCHORED PER OVERHEAD AND SIDEVIEW VIEW TH DETAILS ON THIS SHEET. i ANCHOR 13. DAYLIGHT OPENING (DLO) IS THE SAME AS EXPOSED GLASS. SEE SHEETS 1, 2, 8 AND 9 FOR LIMITATIONS & GLAZING I SEE NOTE TYPES. = 14.WHEN USING CONTINUOUS HINGE THE MINIMUM DISTANCE FROM DOOR EDGE TO EXPOSED GLASS IS 6-1/4" AT STILES c0 AND 7-1/2" AT MIDRAILS. O INSTALL p _ N LEFT (ABLE 2. CO H JAMB 4 1 1 LAMINATED GLASS WITH SENTRYGLAS SUPERLITE II -XL BY SAFTI WITH SEN' 7 NOTE 2. HINGE REINFORCEMENT DOOR ASTM P 8 GE REINF FRAME AS 9 NOTE 2. 4.5" X 4.5" BUTT HINGES SEE SHT OPTIONAL CONTINUOUS HINGE SEE S 10 1 CORE MATERIAL (SHEET 15): D HONE) B&FP( 11 1 LOCKING HARDWARE - SEE SHEET 2 12 1 THRESHOLD SILL W BUMPER GASKET 12A) 566 ZERO SEE SHT. 5 WATER R, 12B 950 NGP SEE SHT. 5 WATER R 12C) 65 ZERO SEE SHT. 6 NON WAT 12D 568 ZERO SEE SHT. 6 NON WAT 13 1 NOTE 1. IJAMB ANCHOR ASTM A924 14 SEE SHEET 6 14A PS074 DOOR SEAL STEELCRAFT 14 1 1 117 14 144 14 1 15 1 FAS-SEAL DOOR SWEEP SEE SHEETS END CHANNEL ASTM A924 14 GA - 17 AS NEEDED CAULK - BUM RUBBER OR SILICON 18 AS NEEDED GLAZING HOLDING DOOR TRIM 1 DEZIGNER TRIM 2 STEEL OVERLAPPNG TRIM 3 STEEL OVERLAPPING TRIM 4) HIGH SECURITY VISION FRAME SG VL 19 NOTE 9. CUTOUT REINFORCEMENT CHANNEL 1 20 1 DOOR SLAB 16 OR 14 GA 21 1 21A 188S DOOR SEAL BY ZERO INT 21B PS074 DOOR SEAL BY STEELCF 22 2 202N DOOR SEAL BY NGP 23 1 23A 139 DOOR SWEEP BY ZERO INT 23B 328 DOOR SWEEP BY ZERO IN: 23C 20ON DOOR SWEEP BY ZERO II 24 3 24A 475 ADJUSTABLE SEAL BY ZEF 1 124B 170N ADJUSTABLE SEAL BY N( 25 1 25A 142 RAIN DRIP BY ZERO INT'L 25B 11 RAIN DRIP BY ZERO INTL 25C 116A RAIN DRIP BY NGP 26 1 ITOP CAP GALV. A60 ASTM A924 SIZE, MAX. (n O II 0p II r TO RIGHT iAX. 'Do " SEE ELEVATION SHT.1 ONLj AX. 100 35.406" X 75.656" MAX w On Q O r w W Q v K xLL m ¢ Q : 11 SEE ABLE 1 ON SHT.2 6* MIN. CUTOUT f n / .5 X 93.44 MAX, MAX. 20 1.23 X 9.19 MIN. 1.5" X 9.19" MIN. 8 12: 24 MS PER HINGE MAX. 95 5.0"XO.5"X48"MAX. MAX. 20' .032" MIN. STL 34.25" X 74.5" EXPOSED GLASS MAX. SILICONE SEE SHEET 5 MAX. 20' TPE SEE SHEET 5 TPE SEE SHEET 5 MAX. 84" OR 96" SEE SHEET 5 MAX. 36" OR 48" MAX. 84" OR 96" FOR JAMB TPE SEE SHEET 5 MAX. 36° OR 48' FOR HEAD MAX. 40" OR 52" FOR HEAD SEE SHEET 5 MAX. 36" OR 48" FOR DOOR .020" MIN. STL 0.5" X 1.76" X 36" OR 48" MAX. FRAME WIDTH = 40" OR 52" MAX. DOOR WIDTH = 36" OR 48" (SEE TABLE 1 ON SHT.2) 7.5" MIN. TO CUTOUT 4 PER TABA ON SHT.2 12" MIN. TO CUTOUT 1.7s• MM LTR DESCRIPTION DATE APPROVED in.7s- MAX. JAMB MAX. FRAME A APPROVAL DWG YMF 05/20/07 INTERIOR I G REVISED DWG YMF 01/04/10 H REVISED NAME JPD 04/09/10 �EXTEMRIOR' J REVISED DWG JPD 11/01/13 6.50' MAXOWR K REVISED DWG JPD 02/01/15 MEyn L REVISED DWG JPD 06/30/15 TYPICAL SILL INSTALLATION DETAIL M ENGINEER CHANGE LMS 12/01/16 OR 52' MAX N REVISED DWG JPD 07/18/18 O LOCK UPDATE YC 11/26/19 4.00" MAX. SEE NOTE 5. OO DOOR HINGE REINFORCEMENT 'o e 07 --A - e 9.750 - CL OF HINGE DOOR HINGE O REINFORCEMENT 8 EXT FRAME HINGE E ! REINFORCEMENT (SEE NOTE 3.) &----HINGE DETAIL'L' HINGE SEE HINGE OPTIONS 3 SHEET 16 CL OF HINGE eQ ®7 cA. FRAME HINGE REINFORCEMENT IL E! O - CL OF HINGE �2KLOCNNELCINNNEL 6"ToIN. CUTOUT _ OUTSWING SINGLE GLASS DOOR (EXERIOR VIEW) BEND RADIUS TO SUIT DOOR HEIGHT CL OF HINGE 10.375 3.5" MIN. `IIIIIiII!/!! E..S N 7 7 ' 10 S A OF SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 YMF 105/20/07 I H-SERIES SINGLE GLASS DOORS (OUTSWING) =CKED 'ROVED SIZE I FLAT DWG NO. IRGS07 APPLL JPD 11/15/07 SCALE: NTS I AUTOCAD 0 3 01 16 OR TO ❑A WNUANCHOR HTECi)OGROOD FRAME JAMB ( ISMI .: © WOOD STUD ANCHOR © STEEL STUD ANCHOR AND BLOCK WALL 00.375" WITH 2' MIN. 6" 8" p2 10" EMBEDMENT POWERS POWER D3 MAX. D3 MAX. 11 MAX. BOLT, POWERS LOK BOLT AS, HILD HLC-F SLEEVE ANCHOR, SIMPSON STRONG T- T DE SLEEVE -ALL 17.6" O.C. 21" O.C. 24" O.C. OR MAX. MAX. 3/8" LAG BOLT INTO (2) 2X MAX. WOOD SILL :SG-.55) 4' X8, i4' 4'X 8'17.6"D.C. x OPENING TD OPENING MAX. z 14' X 8' 21.O.C. 24" O.C. a + aPENING MAX. MAX. 17.6' O.C. 4o F3 CF MAX. F -I- 21' O.C. 3.25' MIN. _• 17.6' O.C. MAX. 0 24" O.C. MAX. WIN. 2-1 /2' MA11X. V LmGE DIS. JAMB BASE ANCHOR T I (WELDED OR ADJUSTABLE) 17.6" O.C. 21AX �AO.C. REFER TO SILL INSTALLATION Mt J_ REFER TO SILL DETAIL 'TH. INSTALLATION 1.625' FRAME i0 E FILLED 6" DETAIL 'TH' MIN E.O. 6- HIM. PSI GROUT MASONRY MAX (2) X 0.AN SOR MAX. MIN EMBER -I T-ANCHOR �-6' MIN. EMHED. /8 X 1-3/4" 0.6 PER ANCHOR (4) TOTAL PER 0.375' MIN. 0.89" EMBEDMENT ANCHOR E.D. 2.5' MIN. E.D. OnaF T:� TWO 2X4AED. 0.375' MIN. 3 WOOD E.D. 2JMIN. SG=0.5REINF. BAR SHIM SPACE f EXT. EXT. EXT.XT 1/4" MAX. SHIM 4" MIN. MASONRY BLOCK WALLS *WOOSPACING THRU *STEEL STUD WALLS. SEE NOTE 1. CIVIL (C-90) 2000PS1 SEE NOTE 1. OUTER HOLE GROUT FILL 175 8' MIN L SPOTWELDED Al�,_WIRE ANCHOR 03/16" (2)PLACES 5/8'1 BRIGHT BASIC WIRE 5,5' Q Q Q 5, Fy MIN_' KSi 5.19" x 9.56" �- WOOD STUD OR Fy MIN.-3e KSI UNIVERSAL WIRE MASONRY ANCHOR MASONRY T-ANCHOR UNIVERSAL ANCHOR Fy MIN. A KSI ANCHOR FMltlm MIN.-58 KSI 8 GA STEEL (0.048) STEEL STUD ANCHOR WELD -IN OR LOCK-N Fy MIN: 36 KSI Fy MIN.-38 KSI (LOCK -IN OR WELD -IN) WELD-N OR LOCK -IN ❑E EXISTING MASONRY ANCHOR (EMA) 11.75• WITH LAG BOLT INTO WOOD STUD B. WALL 11.7s MAX. 11.75' POURED CONCRETE MAX. MAX. H1D3 FMAX F TILT UP WALL I I T- tas' o.cAtAx. to.s' o.cAtAx. tas' o.cAt�Ax. e- tas• o.cAIAX �- tas" o.uLIAX tas' o. ta5' O.CJAAX tas• o.aM�Ax. EXISTING MASONRY ANCHOR (EMA) INTO CONCRETE WALL OR CUMU FHD1 OR HD2 fun% 21" O.C. MAX. 4' X8' 21. OPENING MAX. 21" 0. MAX. 21" O.C. MAX. . , REFER TO SILL JINSTAL ATION DETAIL 'TH' 6" MAX. 2' MIN. EMBEDMENT 3.125" IM N. EDGE DIST NCE O 3.125 MIN. EDGE O DISTANCE- T MIN 200GPM GROUT DUED (0-20) GMU BLOCI( WALL 1/45 MA% am FRAME JAMB DETAIL HD2 T0• INTERIOR' MAX 4' X 8' C OPENING C 24" D.C.; 1/4- X 1-3/4" OR I I I EXTERIOR _ _ MAX.TAPCON I #14 X 1-3/4" MAX. + WOOD SCREW DETAIL'TH' o x I AS REQUIRED SILL INSTALLATION 24' O.C. o. - SINGLE OUTSWING DOOR MAX. ALSO SEE SHEETS 5 & 6 w o 24" O.C. EXTERIOR w 4' X 8' MAX. REFER TO SILL J REFER TO SILL MAXIMUM INSTALLATION 16 0 INSTALLATION DETAIL 'TH' 1s 1 t of 'TH' OPDOOR ENING 16 3" MAX. 3" MIN. MIN. 1.623' EMBEDMEN MIN. E.D. MASONRY 8.5' EMBEDMENT-1 WRE 'VilHgt I.5' MIN. -I 1/4"X7-3/4" TA. IN E.D. E.D. O DISTANCE • " •' ' .5' EDGE OR #14X1-3/4" WS •DISTANCE125" MIN. EMBEDMENT 1.25" MIN. EDGE DISTANCE �v'!• 64• 4 01• E.D. EDGE DISTANCE INTO WOOD SILL (SG-.55) Do� ' EHHEOMENTRETE SILL , DETAIL'TH' 2.5" MIN. EDGE DISTANCE EXT. SILL INSTALLATION SIDE VIEW INTO CONC LAG BOLT gNyGLE OUTSWING DOOR EXTERIOR 3/13" DIA. W/3" MIN. MIN. 2700Psi POURED NOTES: (3 KSI MIN.) EMBEDMENT TWO 2X4 CONCRETE WALL 1.(-)WOOD OR (")STEEL STRUCTURAL MEMBERS OF WOOD SHIM SPACE WOOD AND STEEL -STUD WALLS MUST BE DESIGNED TO CARRY AT D 1 /4" MAX. WOOD STUD WALLS MIN. SG-0.55 11' HIM -LEAST 312 //FT. LOAD FOR ASSEMBLIES RATED 075 TYP. SEE NOTE 1. 1.75- ELo PSF,AND 416p/FT. FOR ASSEMBLES RATED 0100 PSF, (P) ELDED WHICH SHOULD BE VERIFIED BY THE APPROPRIATE OFFICIAL C v MINIW .sIzE 2.NUMEER OF ANCHORS FOR VARIOUS OPENING HEIGHTS IS S ✓.L JI WIRE ANCHOR 03/16" LIMITED BY MAXIMUM DISTANCE BETWEEN ANCHORS, SHOWN q TI[77'`jlUll BRIGHT BASIC WIRE 5.5' Q Q Q 1.75, ON THIS SHEET. 5.19' X 9.56" 3.SEAL ALL JOINTS WHERE FRAME MEETS WALL WITH BUM MASONRY T-ANCHOR WIRE ANCHOR MASONRY 8 GA STEEL (O.G48') RUBBER OR SILICONE CAULK E NMI, MIN.-58 KSI T-ANCHOR Fy MIN. 36 KSI 4.INSTALL THRESHOLD INTO BEAD OF BUM RUBBER OR LOCK -IN EMA-U ANCHOR WELD -IN Fy MIN.=36 KSI SILICONE CAULK FULL LENGTH OF SILL LTR DESCRIPTION DATE APPROVED G REVISED DWG YMF 01/04/10 H REVISED NAME JPD 04/09/10 J REVISED DWG JPD 11/01/13 K REVISED DWG JPD 02/01/15 L REVISED DWG JPD 06/30/15 M ENGINEER CHANGE LMS 12/01/16 N REVISED DWG JPD 07/18/18 ❑ LOCK UPDATE YC 11/26/19 2" MIN. EMBEDMENT 4 3.12511 MIN. EDGE .IS' NC' 3.125 IN. EDGE DISTANCE ON. 3000PM CONCRETE Y WITH 2 MIN. EMBEDMENT IS POWER BOLT, IS LOK BOLT AS, 1LO-FRH SLEEVE ANCH OR HD1 - FRAME HEAD SECTION 2 I 2' FACE W = WITHOUT w 6 GROUT � EXTERIOR 0 1.75' ie"col7miii"' CONCRETE LINTEL SHOWN MAY VARY PER FRAME HEAD WALL FILLED W/2000 CONSTRUCTION. PSI GROUT ~ " '• 2' OR 4' FACE GROUT FILLED w x 1 EXTERIOR LL WOOD STUD LINTEL SHOW 1 1 D STEEL STUD MAY ALSO BEJ1.75' Z" FACE- WITHOUT GROUT 175' CONSTRUCTION HD2 - FRAME HEAD 111// ! w x u- F_XTE 'O $ /{ OF a• � � i T Q 112R • • �/ HD3 - FRAME HEAD SECTION 348�yEA HS D.8` f L 93DR1 FBPE CER �HB N NO. 29 BEND RA➢IUS SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 -�- THIRD ANGLE PROJECTION TITLE: STEELCRAFT H SERIES SINGLE OUTSWING GLAZED WITHOUT PANIC EXIT DEVICES COMMERCIAL STEEL DOORS WITH ANC AWN DATE YMF 0/2V07 FRAME ANCHOR DETAILS & INSTALLATION CONDITIONS. =CKED 'ROVED SIZE FLAT DWG NO. IRCS07 REV -, APPVL SCALE' NTS I AUT❑CAD I ISHEET 4 Of 16 JPD 10/1147 TABLE 3.1 WATER RATED PERIMETER SEAL ZERO INT'L 566 THRESHOLD GASKETING SYSTEM REQUIREMENTS FOR WATER INFILTRATION - MAXIMUM DESIGN PRESSURE RATING 75PSF - MAXIMUM DOOR SIZE 4'-0" X 8'-0" (SEE ELEVATIONS, SHEET 1) E - ZERO INT'L THRESHOLD 566 TABLE 3.2 WATER RATED PERIMETER SE) )PRENE (full lengm)1 r 0.125 I ITEM MODEL No./ 0.25 EXT I F NUMBER DESCRIPTION MFG. �aT 050 12B 1950 THRESHOLD NGP I 5.00 FT 15 1 FAS-SEAL SWEEP STEE 9ZERO INT'L 566 SERIES THRESHOLD 16 END CHANNEL $TEE MAX. DESIGN PRESSURE Ib 75 PSF L I-- 0.88' I-�sao `mxso•sNs 0.39" ra�D Do •, cTamc•.P�D 25 ZERO 142 24A ZERO 475 RAIN DRIP ADJUSTABLE SEAL 0.z^ I 1.00, D•-4 � � I- 0.07' C) ZERO I683 ZERO 139 ZERO 328 25A 1A DOOR SEAL 3 DOOR SWEEP 23B OOR SWEEF 421A TOP OF DOOR 0.06' sl- Ln95 26 FRAME HEAD 16 1.38" 0.06]" ,688" 0,6i 2qq 0.024 I 1.66^ I- 1.316 -{ 0.59" H211' ZER011 16 DOOR 26 DOOR TOP CAP oxui note END CHANNEL EXTERIOR k INTERIOR �I( 256 236 0.50' CLE 0.ODR CLEARANCE E.D. 1/4-XI-3/4- TAPCON / 1.25' IN. EDGE DISTANCE OR /14 WOOD SCREW-� INTO WOOD SILL (SG-.55) 1.25" MIN. EMBEDMENT 2.5- MIN. EDGE DISTANCE INTO CONCRETE SILL (3 KSI MIN.) BOTTOM OF DOOR WEATHERSTRIPPING AND SILL INSTALLATION 47.625 3.91 -I I_AX. -1 3.91 11.25 17.3 --L I125 SEEN 1 RIGID SECDON SEE NOTE 2 F -r 0.5D -ilixlBLE VV sECR. 1.25 (NOTE 3) FAS-SEAL DOOR SWEEP 22 1202N DOOR SEAL I NGP 23C 120ON DOOR SWEEP NGP 24B 1170N ADJUSTABLE SEAL NGP 25C 116A RAIN DRIP I NGP REQUIREMENTS FOR WATER INFILTRATION - MAXIMUM DESIGN PRESSURE RATING 75PSF FOF MAXIMUM DOOR SIZE OF 3'-O" X 7'-O" MAXIMUM DESIGN PRESSURE 50 PSF FOR MAXIMUM DOOR SIZE OF 4'-0" X 8'-0" (SEE ELEVATIONS, SHEET 1) 21B 26 TOP OF DOOR FRAME HEAD 16 24B EXTERIOR INTERIOR I 8 SEE / 6 0.375' FLOOR EMBEDMENT CLEARANCE E.D E.D. EXT. INT. EXT. INT. I/4-X7-3/4"TAPCON 1'25- MIN. EDGE DISTANCE 1ODOR SILL (SG- - WOOD SCREW ZS- MIINN. EDGE DISTANCE) 1.25" MIN. EMBEDMENT INTO CONCRETE SILL (3 KSI MIN.) TYPICAL THRESHOLD SET INTO TYPICAL THRESHOLD SET INTO BOTTOM OF DOOR WEATHERSTRIPPING BEAD OF CAULK SEE NOTE 6 BEAD OF CAULK SEE NOTE 6 AND SILL INSTALLATION APPLIED 000R SEu AREA OF HIN o�ooRSEAL 24 To THE SOFFIT 24 REOTO KEAD DOOR SEAL A PLIED TO HEAD qN0 PMBS AHEAD ANO JAMBS HILIAGAINST of s CLOSED DOOR 21 21 AMB2 e SEE SHEET 3 FOR HINGE REINFORCEMENT STRIKE JAMB EXTERIOR STRIKE JAMB HINGE JAMB o.Z t200N 5' LIMPER (full length) r Q,078 r 0.25 EXT a�jT� 0 r 5,00 I_7 NATIONAL GUARD 950 SERIES THRESHOLD MAX. DESIGN PRESSURE +I- 50 PSF 4'0"X6'O" MAX. 12B MAX. DESIGN PRESSURE+/- 75 PSF 3'0"x7'0' MAX. SEE SHEET Na 6 x51W 1.0' PHSMS 50" No. 8 x 5/6' PRISMS NGP i6 NGP 17ON 25C RAIN DRIP 24B ADJUSTABLE SEAL FLEXIBLE 40° Nu SEMI -RIGID 1.W" L 0.024r50" PHSMS 0.625" PS'O" 21 STEEAO NGP 20IN DOORRS SEALL 22 DOOR SEAL 1.719 0.06]' .688' 7 OA2 0.62 86" 1-- 1,316 -I DOOR 126 DOORTOPCAP ENO CHANNEL 47.625 3.91 -I MAX. -{ 3.91 L- 17.3 --L SEE NOTE 1 1125 1125 RME SECTION NOTE 2. I\IffE,I�1-�1yyl�r 0,50 �-�W�1 1• SECTION) FASSEAL DOOR SWEEP LTR DESCRIPTION DATE APPROVED A APPROVAL DWG YMF 05/20/07 G REVISED DWG YMF 01/04/10 H REVISED NAME JPD 04/09/10 J REVISED DWG JPD 11/01/13 K REVISED DWG JPD 02/01/15 L REVISED DWG JPD 06/30/15 M ENGINEER CHANGE LMS 12/01/16 N REVISED DWG JPD 07/18/18 0 LOCK UPDATE YC 11/26/l9 NOTES: 1. SLOT LOCATIONS MAY VARY WITH DIFFERENT DOOR WIDTH. 2. DOOR SWEEP RIGID SECTION IS MADE OF PRO -FAX #PD-199 POLYPROPYLENE HOMOPOLYMER. 3. DOOR SWEEP FLEXIBLE SECTION IS MADE OF SANTOPRENE #101-73 4. FAS-SEAL DOOR SWEEP (15), AND THRESHOLD (12A OR 12B AS REQUIRED) ARE REQUIRED FOR ALL INSTALLATIONS. 5. SEAL ALL JOINTS WHERE FRAME MEETS WALL WITH BUTYL RUBBER OR SILICONE CAULK 6. INSTALL THRESHOLD INTO BEAD OF BUTYL RUBBER OR SILICONE CAULK FULL LENGTH OF SILL BEND RA➢IUS `11111I11l/// I� 10 S A OF Doo _E TO THE SOOFFIT 000R SEAL AREA OF HINGE 22 APPIEDeo HEAD JAMBS AHD JAM S CLOSED DOOR 21B SEE SHEET 3 FOR HINGE REINFORCEMENT EXTERIOR HINGE JAMB SCHLAGE LUCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 THIRD ANGLE PROJECTION TITLE. STEELCRAFT H SERIES SINGLE DUTSWING GLAZED COMMERCIAL STEEL DOORS WI1 AND WITHOUT PANIC EXIT DEVICES SINGLE GLAZED DOUR PERIMETER SEAL HARDWARE APPROVED WHERE WATER INFILTRATION IS REQUIRED DRAWN YMF DATE OS/20/07 CHECKED APPROVED SIZE FLAT DWG N0. R I R G S 0 7 ENG. APPVL JPD 1 11/0) SCALE' NTS I AUT❑CAD I rIEET 5Gf 16 C TABLE 4.1 NON WATER RATED PERIMETER SEAL H/ ZERO INT'L 566 AND 568 THRESHOLD GASKETING SYSTEM REQUIREMENTS WHEN WATER INFILTRATION IS NOT REQUIRED. MAXIMUM DESIGN PRESSURE RATING 75 PSF ZERO INT'L 65 THRESHOLD GASKETING SYSTEM REQUIREMENTS WHEN WATER INFILTRATION IS NOT REQUIRED. MAXIMUM DESIGN PRESSURE RATING 70 PSF MAXIMUM DOOR SIZE 4'-0" X 8'.0" (SEE ELEVATIONS, SHEET 1) 14 TOP OFDOOR FRAME HEAD 16 EXTERIOR 0— FLEXI NEOPRENE (full IeNt:h}-� r D,125 ) �o.2s EXT \rl�l �� � Aso T15,00 !_T ZERO INT'L 566 SERIES THRESHOLD 12 MAXIMUM DESIGN PRESSURE +/.75 PSF (SEE SHEETI) SILICONE (fulll p r 0,25 EXT I � EX 1 050 TI 5.00 ZERO INT'L 65 SERIES THRESHOLD 12C MAXIMUM DEISGN PRESSURE +1- 70 PSF (SEE SHEET 1) 1EOPRENE(Mill lenglM1}-1 r0, 125 ) r 0.13 EXT \ I Imo_ 0 r! 6.0V I_T ZERO INT'L 568 SERIES THRESHOLD 12D MAXIMUM DESIGN PRESSURE+1.75PSF (SEE SHEET1) BLE, p a. �f D .9 .Ti .50'�- Aw 14A PS•074 STEELCRAFT 1 QB ZERO 188S DOORSEAL 14C ZE- 111S DOOR SEAL DOORSEAL D.44" ZERO 81445 ZERO 61503 DOOR 14D DOOR SEAL 14E DOORSEAL 16 END CHANNEL 47.625 MAX. a91 17.3 F 1125 1, SEE NOTE 1 FASSEAL DOOR SWEEP al'i TABLE 4.2 NON WATER RATED PERIMETEI ITEM MODEL No./ NUMBER DESCRIPTION MFG. 12B 950THRESHOLD NGP 14A PS074 DOOR SFAI I STIFF REQUIREMENTS WHEN WATER INFILTRATION IS NOT REQUIRED - MAXIMUM DESIGN PRESSURE 100 PSF FOR MAXIMUM DOOR SIZE OF 4'-0" X 8'-0" (SEE ELEVATIONS, SHEET1) i6 'g3g CAUL g SEE 17 15 12 CAULK SEE EXT. INT. EXT. INT. NOTE 6 17 NOTE 6 0.375' FLOOR EMBEDMEN CLEARANCE E.D. E.D. TYPICAL THRESHOLD SET INTO TYPICAL THRESHOLD SET INTO 1/4"X1-3/4" TAPCON 1.25' MIN. EDGE DISTMJCE BEAD OF CAULK SEE NOTE 6 BEAD OF CAULK SEE NOTE 6 OR /14 WOOD SCRE INTO WOOD SILL (SG—I!5) 15' .25' MIN. EMBEDMENT 2.MIN. EDGE DISTANCE INTO CONCRETE SLL (3 KS MIN.) BOTTOM OF DOOR WEATHERSTRIPPING AND SILL INSTALLATION Doors SEAL o TO HEAD APPLIED TO HEAD ANDLJAMBS AND JAMBS 4 14 SEE SHEET 3 FOR HNOE RONFORCDAENT STRIKE JAMB EXTERIOR 14A TOP OF DOOR FRAME HEAD 16 EXTERIOR 0.375' FLOOR j E_D. E.D. CLEARANCE 1/4"X7-3/4"TAPCO INTO"NVOD ES LPL (SG_. OR /14 WOOD SCREW 2,5" MIN. EDGE DISTANCE 1.25" MIN. EMBEDMENT INTO CONCRETE SILL (3 KSI MIN.) BOTTOM OF DOOR WEATHERSTRIPPING AND SILL INSTALLATION SILICONE, VINYL OR NEOPRENE L LTR DESCRIPTION DATE APPROVED BUMPER (full length) F0.078 I A APPROVAL DWG YMF 05/20/07 ��0.25 Exr�� � uS0 G REVISED DWG YMF 01/04/I0 r! 5.00 (� H REVISED NAME JPD 04/09/10 NATIONAL GUARD 950 SERIES THRESHOLD J REVISED DWG JPD 11/01/13 126 MAXIMUM DESIGN PRESSURE+/. 100 PSF (SEE SHEET I) K REVISED DWG JPD 02/01/15 FLEXIBLE � _ o.osr L REVISED DWG JPD 12/ 0/15 1/16 SEMI -RIGID 40 .s3s^ M ENGINEER CHANGE LMS l2/01/16 0.02jI---O.N REVISED DWG JPD 07/18/18 0 LOCK UPDATE YC 11/26/19 PS-074 aSTEELCRAFT O DOOR 14 DOORSEAL 16 END CHANNEL 47411 N.. a9t_ va j-17.3 IT ILES 3.91 Noa r BEC L23 9 _L FASSEAL DOOR SWEEP `III11111!/// �� O NOTES: .. , 1. SLOT LOCATIONS MAY VARY WITH DIFFERENT DOOR WIDTH. •'�•• E•. • �O ( 2. DOOR SWEEP RIGID SECTION IS MADE OF PRO -FAX #PD-199 POLYPROPYLENE = -; • �.� `s 6 HOMOPOLYMER. N 7 7 3. DOOR SWEEP FLEXIBLE SECTION IS MADE OF SANTOPRENE #101-73 4. FAS-SEAL DOOR SWEEP (15), DOOR SEAL (14A, 14B, 14C, 14D, 14E) AND THRESHOLD (12A, 12B, 12C, 12D) AS APPLICABLE, ARE REQUIRED FOR ALL INSTALLATIONS. S A OF 5. SEAL ALL JOINTS WHERE FRAME MEETS WALL WITH BUTYL RUBBER OR SILICONE �T 4c, ' CAULK 6. INSTALL THRESHOLD INTO BEAD OF BUTYL RUBBER OR SILICONE CAULK FULL .AgEp•" 37 unn cD LENGTH OF SILL /// c N ppoap4 Fw�tuy. TYM4o. zesn HEND RA➢IUS DOOR SEAL DOOR SEAL APPLIED TO HEAD APPLIED TO HEAD AND JAMBS AND JAMBS 14A 14A SEE SHEET 3 FOR HINGE �70 RDNFORCEMENT STRIKE JAMB EXTERIOR HINGE JAMB SCHLAGE LUCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 YMF 0512V11 SINGLE GLAZED DOOR PERIMETER SEAL HARDWARE =CKED APPROVED WHERE WATER INFILTRATION IS NOT REQUIRED 'ROVED SIZE I FLAT DWG NO. IRGS07 REV S. APPVL JPD l0/11/0] SCALE' NTS AUT❑CAD HEET 6-f 16 BENT TABS �T0 SECURE ASSEMBLY Q 2 'KD' "KNOCKED -DOWN" ASSEMBLY a \ e HEAD ANCHOR TOP OF JAMB HEAD NOTCHED AND BOLTED ON TOP OF JAMBS TYPICAL FRAME PROFILE DOUBLE RABBET C 1 4" MAX. OPTIONAL FOR HEAD SECTION 2" MIN. r 0.625" MIN. DOOR SIDE' TVA EXTERIOR 1.938' 5.75' MIN. 0.625" I VARIES 5.75" JAMB MIN. T 1.938" DOOR SIDE EXTERIOR 2"TYP TYPICAL FRAME PROFILE DOUBLE RABBET 'SUA' SET-UP AND ARC -WELDED ASSEMBLY CLI P ) TO HEAD JAMB HEAD NOTCHED AND BOLTED BETWEEN JAMBS WELDED WELDED r HEAD NOTCHED HEAD SITS ON TOP AND BUTTED BETWEEN JAMBS OF NOTCHED JAMBS #8 X 5/8 TRUSS HEAD SMS NOTES: 1. DOOR CONSTRUCTION 1.1. MINIMUM DOOR THICKNESS - 1 3/4" 1.2. DOOR SIZE MAY VARY, SUBJECTED TO COMPLIANCE WITH FLORIDA BUILDING CODE AND PRODUCT AVAILABILITY FROM MANUFACTURER (SEE SHEET 2 FOR AVAILABLE HARDWARE) 2. FRAME CONSTRUCTION 2.1. MINIMUM JAMB DEPTH - 5 3/4", STOP HEIGHT - 5/8" 2.2. FRAMES AVAILABLE AS FLUSH (F-SERIES) AND MULT-USE (MU -SERIES) (SEE TABLE 6) 3. FOR DOOR AND FRAME MATERIAL SPECIFICATIONS REFERENCE SEE TABLE 7. LTR DESCRIPTION DATE APPROVED A APPROVAL DWG YMF 05/20/07 G REVISED DWG YMF 01/04/10 H REVISED NAME JPO 04/09/10 J REVISED DWG JPD 11/01/13 K REVISED DWG JPD 02/01/15 L REVISED DWG JPD 06/30/15 M ENGINEER CHANGE LMS 12/01/16 N REVISED DWG JPD 07/18/18 0 LOCK UPDATE YC 11/26/19 TABLE 5. AVAILABLE STEELCRAFT DOOR CONFIGURATIONS CORE MATERIAL MAXIMUM OPENING SIZE SKIN MATERIAL PER SHT.15 WIDTH I HEIGHT DESCR. GA. MIN. THK HONEYCOMB POLYSTYRENE POLYURETHANE VARIES CRS 16/.053" (POLYISOCYANURATE) SEE SHT 2 TABLE 1 GALV 14/.067" TEMPERATURE RISE STEEL STIFFENED HONEYCOMB VARIES STAINLESS 16/.053" POLYSTYRENE POLYURETHANE SEE SHT 2 TABLE 1 STEEL .053" MU' SE" SERIES TABLE 6. AVAILABLE STEELCRAFT FRAME CONFIGURATIONS EMBLY bUA - OPTIONAL FRAME SERIES JAMB DEPTH MAXIMUM OPENING SIZE TABLE 7. STEEL MECHANICAL PROPERTIES MATERIAL ASTM REF. YIELD KSi TENSILE KSi CRS A366 MIN. 41.5 MIN. 52.4 HRS A1011 GALV: A60 A924 SS:304,316 A240 MIN. 41.5 MIN. 73.2 `11111 I I I"II * N .7 7 'o S A OF FBPE CERT!OV A WRRAmW NO. 295781 BEND RADIUS SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET Klk\_-EEEj_ CARMEL, IN 46032 THIRD ANGLE PROJECTION TITLE: STEELCRAFT H SERIES SINGLE OUTSWING GLAZED COMMERCIAL STEEL DOORS WITH AND 4WN DATE WITHOUT PANIC EXIT DEVICES YMF 05/20/07 FRAME PROFILE, CORNER DETAILS AND DOOR FRAME -CKED MATERIAL, AND SIZE OPTIONS. 'ROVED SIZE FLAT DWG NO. REV IRGS07 0 ;. APPVL JPD 11/15/07 SCALE` NTS ��AUTOCAD SHEET 7 of 16 8 1/8• MIN TO EXPOSED GLASS MAX. MAX, DLO DOOR HEIGHT HEIGHT 64" OR 74.5" 84" OR 96" MAX. DOOR WIDTH 36"OR 48" 6 3/4" TYP. EXPTO OSE GLASS 8 1/s- M. TO EXPOSED GLASS 6 3/4- TYP. MIN ED GLASS EXPOS r 8 1/8• MN TO EXPOSED GLASS 7.5' MIN. TO E%POSED GLASS 6 3/4" TYP. E%POSm — MINTGLA65 r 8 1/8• MIN TO EXPOSED GLASS 7.5' MIN. GLASS SED 7. EXPOSED GLASS 6 3/4" TP. E%P MIN GLASS MAX. DLO WIDTH 24"OR 34.25 // �/ R —i R R // I SEEj%T 9 SE� T. 9 M t2 a� / Mlry ES 1z 3/C MIN 10 12 EXPOSED EXPOSED GLASS 12 31 D IN 70 E%POSED l J_ FG-LITE FG2-LITE FULLY GLAZED HORIZONTAL MID -RAIL 6 3/4' Mlro 6 3/4• 6 3/4' EXPOSED MIN, TO GLASS EXPOSED GLASS IN. TO � E%POSED GU55 p I I-T. I-1� BIN. TO r I EXPOSED GLASS MAX. GLAZING II DLO & 12" X 12" MAX. GLAZING DLO 3" X 33" V VISION LITE 6' MIN. 8.825' TP. EXPOSED CLASS EXPOSED GLASS L 5 3/8' 5 3/8' MIN. TO D �/ MIN. TO EXPOSED GLASS 4 EXPOSE] GLASS EXPOSED GLASS on E4 TL 6 3/4' FG3-LITE 2 HORIZONTAL MID G-LITE -RAILS HALF GLASS 6 3/4' MIN, TO EXPOSED GLASS 8 1/8- MIN. TO LNL LONG NARROW LITE 6 3/4' MIN. TO EXPOSED GLASS 8 1/8" MIN. TO EXPOSED GLASS I EXPOSED GLASS I MAX. DAYLIGHT OPENING FOR CONFIGURATION 9 AND 10 IS 144 SQUARE INCHES 12" X 12" MAX.'V' VISION LITE MAX. GLAZING MAX. GLAZING MAXIMUM DAYLIGHT OPENING FOR DLO DLO CONFIGURATION 9A AND 10A IS 4" X 25" 5" X 20" 100 SQUARE INCHES DLO WX33" 'NT W. X 25"'N4' 5' X 20"'N5' SEE TABLE 1 SHEET 2 DLO= DAY LIGHT OPENING N3 N4 6' MIN. o EXPOSED GLASS EMBOSSED PANEL DOORS 00 NS m s E2 G9 SHOW SURFACE APPLIED MUNTINS (FALSE DIVIDERS) ", . " ASSEMBLY MUNTIN ARRANGEMENT SURFACE MOUNTED MAYVARY TO THE GLASS 6 3/4' MIN. TO EXPOSED GLASS N NARROW LITE R E V I S I❑ N S DESCRIPTION DATE APPROVED APPROVAL DWG YMF 05/20/07 REVISED DWG YMF 01/04/10 REVISED NAME JPD 04/09/10 REVISED DWG JPD 11/01/13 REVISED DWG JPD 02/01/15 REVISED DWG JPD 06/30/15 ENGINEER CHANGE LMS 12/01/16 REVISED DWG JPD 07/18/18 LOCK UPDATE YC 11/26/19 1. DOOR CONSTRUCTION 2. MINIMUM DOOR THICKNESS - 1 3/4" 3. ALL GLASS LITE TYPES SHOWN ON THIS SHEET ARE AVAILABLE FOR ALL DOOR CONFIGURATIONS SHOWN ON SHEET 1 AND TABLE 1 SHEET 2 EXCEPT FOR CONFIGURATIONS 9, 9A, 10 AND 10A. SEE NOTE 4. 4. DOOR CONFIGURATIONS 9 AND 10 AVAILABLE WITH V VISION LITE AND 9A AND 10A IS AVAILABLE WITH N3, N4 AND N5 TYPE LITE. (SEE TABLE 1 SHEET 2) 5. MAXIMUM GLAZING DLO HEIGHT AND WIDTH AS PER SHEETS 1, 2, AND 8. 6. GLAZING OPENING DLO SIZE WILL CHANGE IN PROPORTION WITH DOOR SIZE.(SEE TABLE 1 SHEET 2 FOR LIMITATIONS) 7. DOOR SIZE MAY VARY, SUBJECTED TO COMPLIANCE WITH FLORIDA BUILDING CODE AND PRODUCT AVAILABILITY FROM MANUFACTURER. 8. GLASS LITES NOT LIMITED TO THOSE SHOWN, PROVIDED DIMENSIONS SHOWN ARE MAINTAINED. (SEE TABLE 1 SHEET 2 ) 9. DOORS WITH MULTIPLE GLASS LITES ARE NOT LIMITED TO THE DESIGNS SHOWN, PROVIDED THE DIMENSIONS SHOWN ARE MAINTAINED.(SEE TABLE 1 SHEET 2 FOR LIMITATIONS) 10. WHEN USING A CONTINUOUS HINGE THE MINIMUM DISTANCE FROM THE EDGE OF THE DOOR TO EXPOSED GLASS IS 6-1/4" AT STILES AND 7-1/2" AT MID RAILS. 11. DLO = DAYLIGHT OPENING (SEE TABLE 1 SHEET 2 FOR LIMITATIONS) 12. VERIFY GLAZING OPTION ON SHEET 9 IS AVAILABLE FOR GLASS LIT&9"fttlW&fSIZE. 1 SlAXOF 1: Z BEND RA➢IUS SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET Klk\ —EEE3- CARMEL, IN 46032 THIRD ANGLE PROJECTION TITLE; STEELCRAFT H SERIES SINGLE OUTSWING GLAZED COMMERCIAL STEEL DOORS WITH AND AWN DATE WITHOUT PANIC EXIT DEVICES YMF 0/20/07 GLASS DOOR CONFIGURATIONS. =CKED 'ROVED SIZE FLAT DWG N0. REV IRGS07 3. APPVL JPD 11/15/07 SCALE' N T S I AUT❑CAD SHEET8 of 16 GLAZING TYPE 1 GLAZING DETAIL'D' DEZIGNER TRIM OPTION DEZIGNER THIN RETAINER 0 GLAZING TYPE 1 1/2' U"AH 1/4OR 1/2 LEXAN GLAZING DETAIL'E' RMNATE BY SABIC IVE PUAcs) (POLYCARBONATE BY SABIC INNOVAIIYE Pl_N ICS) STEEL TRIM OPTION GLAZING ADHESIVE //66 18 X 1.25• ZING ADHESIVE SKAREX 222 UV SELF TAPPING SM: AnEX 222 UV OR 295 UV 1/8. THICK % 3/V 10. OC MAX 295 UV e' THICK X 5/8' E BEAD W1DE BEAD GLAZING BEAD (INTERIOR SIDE STEEL TRIM ADHESIVE-S:AUNT (EXTERIOR SIDE) S//KARE%-552 THICK X 1/2" D YhDE BEAD 10" OC MAX. 2.5" MAX. D 0 FI O.H.S M. SCREWS O.H M. hR ��CC m• oc uA% ^ Mu STEEL TRIM CORNER DETAIL LAMINATED GLASS DETAILS SentryGlas 0.090" �C 1/4- HEAT Interlayer SENTRYGLAS ` INT STRENGTHEN INTERLAYER GLA55 0.09" 0.25" T EXT 0.25" % �EN � a� 0.25' 1/4' HEAT 1D0.2L15' `1/4-STREH EAT DENT y GLASS aAxi INNMESCGEL p P5• GEL CONSTRUCTION DETAIL 'H' 1-1/16" SUPERLITE II -XL- CONSTRUCTION DETAILV BY SAFTI 9/16" HS LAMINATED GLASS WITH WITH SENTRYGI INTERLAYER SENTRYGLAS INTERLAYER 0.156" A N M N O 100 0 -VARIES- DEZIGNER TRIM 18 PROFILE MATERIAL: 24 GA A40 STEEL STEEL TRIM 18-2 MATERIAL: 20GA A40 STEEL GLAZING TYPE 2 GLAZING TYPE 2 GLAZING DETAIL'K' GLAZING DETAIL T' LAMINATED GLASS LAMINATED GLASS 9/16• HS LAMINATED GLAZING ADHESIVE GLASS NTH SENiRYGLAS SIKAFLEX 552 1/16' THICK X 5/8' DEZIGNER INTERLAYER DETAIL V TRIM M1DE BEAD GLAZING ADHESVE RETAINER SIKARE% 552 1/18' THICK X 5/8' STEEL TRIM MIP HIDE BEM (EXTERIOR) ADHESIVE -SEALANT SIKAFLEX-552 1/16- THICK X 1/2" WIDE BEM 9 DEZIGNER TRIM GLAZING TYPE 3 .41 NTUMESCENT 1/4- TEMPERED MASS 1-13/16' NOM. SUPERLITE III - S1R MR.. GLA2No- rnHE9 E BY Dow caNRw EXTERIOR THRU BOLT _ STEEL MAX. 12' OC 1/a' TUIPFTen G55 GL �SDIIR�Y�d�A9 IN1ERlA1FR 0.090' jE- 51RUCNRAL GIAZND H-SERIES® DGOR BY STEELCRAFT SECURITYVISION FRAME SG-10 BY ANEMOSTAT 9/16- HS LAMINATED MASS NTH SFNTRYMAS INTERLAYER DETAIL V GLAZING BEM GNTERIOR) /8-18 X 1.25 MIF TAPPING MIS 10' OC MAX TABLE 8. STEEL TRIM GLAZING TYPE 3 GLAZING DETAIL'G' 1" STEEL TRIM OPTION 1-1/16" NOM.. SUPERUTE II-*�H(I,N= ZING BEAD SEE DETAILIOR SIDE) 1.25• GLAZING ADHESIV (SEE TABLE SMS MAX �( / I 1- STEEL TRI (EXTERIOR SIDE 10" OC MAX 2.5MAX. EXTERI / I 0.563" BITE ® H-SE D BY SIEEECR \9pwBB SC 0D.H.SM. 10" OC MAX OR VLF-S10 BY AIR LOUVERS 1" STEEL TRIM N 50" L I-1.75"-I I" STEEL TRIM 18-3 MATERIAL: 20 GAGE A40 STEEL 80-82' 'vT n COUNTERSUNK HOLES FOR /j6 OHSMS U-375" GLAZING BEAD FOR STEEL OVERLAPPING TRIMS 20 GAGE A40 STL I FOR 1-13116" GLASS I CORNER DETAIL No. 8 x 32 Thru-Bolt 12" MAX. OC (Factory Provided) O O tV 1.00" 0.375"� HIGH SECURITY 18-4 METAL VISION FRAME MATERIAL: 12 GAGE OR 10 GAGE ANEMOSTAT SG-10 AND AIR LOUVERS VLF-S1O LTR DESCRIPTION DATE APPROVED A APPROVAL DWG YMF 05/20/07 G REVISED DWG YMF 01/04/10 H REVISED NAME JPD 04/09/10 J REVISED DWG JPD 11/01/13 K REVISED DWG JPD 02/01/15 L REVISED DWG JPD 06/30/15 M ENGINEER CHANGE LMS 12/01/16 N REVISED DWG JPD 07/18/18 0 LOCK UPDATE YC 11/26/19 GLAZING TYPES AND METHODS GLAZING TRIM TYPE SEALANT GLAZING ADHESIVE TYPE MATERIAL -ADHESIVE LEXAN BY SABIC DEZIGNER 1/2" SIKAFLEX 222UV 1 INNOVATIVE PLASTICS OR 1/4" SIKAFLEX 552 OR 295UV STEEL TRIM 1/4" OR 1/2" 1/16" X 5/8" DETAILS V & 'E' BEAD 1" STEEL TRIM 9/16" HS DEZIGNER 1/2" LAMINATED GLASS STEEL TRIM 2 WITH SENTRYGLAS INTERLAYER SIKAFLEX 552 SIKAFLEX 552 OR DOW CORNING DETAILS 995/975/983 'J', 'K' & 'L' 1" STEEL TRIM 1/16" X 5/8" BEAD 3 SUPERLITE II-XLT" BY SAFTI WITH SENTRYGLAS INTERLAYER DETAILS 'H', 'F' & VOR 1" STEEL TRIM (DETAIL 'G') NONE SIKAFLEX 552 OR DOW CORNING 995/975/983 1/16" X 5/8" BEAD SECURITY VISION FRAME SG-10 BY ANEMOSTAT VLF-S70 BY AIR LOUVERS NONE (DETAIL 'F') NOTES. �: v\'YO i 1. SEE SHT.1 FOR ELEVATIONS, SHT.2 FOR SIZES AND SHT.7 FOR DOOR & FRAME N MATERIAL SPECIFICATIONS. 2. SSEE TEMSHT. 4 FOR ANCHOR REQUIREMENTS, WALL CONSTRUCTION AND ANCHORING S A OF 3. SEE SHT. 7 FOR AVAILABLE OPENING SIZES, JAMB DEPTHS AND SPECIFICATIONS �� Q © • •• �/�� 4. APPROVED HARDWARE TO BE INSTALLED PER MANUFACTURER'S INSTALLATION 'Seq INSTRUCTIONS. 5. VERIFY GLAZING MATERIAL IS AVAILABLE IN SIZE REQUIERED. E. IA�pAA���.IA FBPE CER7!OP H L 330B,d• 110N NO. 29578 BEND RADIUS SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 --EEE3- THIRD ANGLE PROJECTION TITLE: STEELCRAFT H SERIES SINGLE OUTSWING GLAZED COMMERCIAL STEEL WITHOUT PANIC EXIT DEVICES GLASS TRIM OPTIONS. DOOR WITH AND DRAWN YMF DATE 05/20/07 I ;. APPVL RGS07 10 JPD 11/15/137 "': NTS I AUTOCAD ISHEET 9 of 16 4X #425 SEX BOLTS (4) X #325 SEXBOLTS (MOUNTED DEVICE THRU BOLTED WITH ON OPPOSITE DOOR FACE) FASTEN #10-24 MACHINE SCREWS TOP AND BOTTOM LATCHES TO DOOR (MOUNTED WITH (7) #1/4-20 MS) UX, LATCH (STAIN LESS TSTEEL) RIKE 299F/499F TOP STRIKE 0 MOUNTED WITH (STEEL) MOUNTED WITH (3) #10-24 SMS (3) #10-24 SMS Fu=120,000 PSI Fu MIN.=120 KS! CROSSBAR LATCH BOLT CENTERCASE TOP LATCH --- VON DUPRIN 88-F RIM DEVICE, USED IN CONFIGURATIONS: 7 & 8 MECHANISM CASE TOP ROD CENTERCASE 4X #425 SEX BOLTS DEVICE CENTERCASE (DEVICE THRU BOLTED WITH THRUBOLTED TO MECHANISM CASE #10-24 MACHINE SCREWS) EXTERIOR TRIM Op AUX. LATCH n PUSHBAR (NOT SHOWN) WITH (4) 310-24 MS 299-F (499-F) 4 STRIKE o m BOTTOM ROD L TOUCHBAR (STAINLESS STEEL) MOUNTED WITH (3) #10-24 SMS 299E STRIKE BOTTOM LATCH Fu=120,000 PSI LATCH CENTERCASET 304L BOTTOM e STRIKE (STEEL) GROUTED INTO FLOOR VON DUPRIN 98/99 & 98/99-F RIM DEVICE VON DUPRIN 98/9927 & 98/9927-F SURFACE VERTICAL ROD EXIT DEVICE USED IN CONFIGURATIOS: 7 & 8 USED IN DOOR CONFIGURATION 3 (SEE SHTA ) 12 GA MID RAIL REINFORCING A18�� CHANNEL CUTOUTEINFORCING CHANNEL DOOR WIDTH-12 VARIEF.5'�1,66' �l M NOTES: 1. ELECTRICAL FUNCTIONS/INSTALLATION AND FIRE RATINGS ARE NOT PART OF THIS APPROVAL, TO BE REVIEWED AND APPROVED BY BUILDING OFFICIAL 2. EXIT HARDWARE OPTIONS: FOR 98/99 & XP98/99 SERIES - OPTIONS E, RX, LX, SS, EL, GEL, CX, F, ALK, CD, PN; (OPTIONS MAY VARY PER SERIES) TRIM: ALL APPLICABLE TRIMS AVAILABLE. FOR 88-F SERIES - OPTION E; TRIM: ALL APPLICABLE TRIMS AVAILABLE. PIN MODEL OFFERED. LTR DESCRIPTION DATE APPROVED A APPROVAL DWG YMF 05/20/07 G REVISED DWG YMF 0I/04/10 H REVISED NAME JPD 04/09/10 J REVISED DWG JPD 11/01/13 K REVISED DWG JPD 02/01/15 L REVISED DWG JPD 06/30/15 M ENGINEER CHANGE LMS 12/01/16 N REVISED DWG JPD 07/18/18 0 LOCK UPDATE YC II/26/l9 GLAZING MATERIAL SEE TABLE 8 ON SHEET 9, SEE SHEETS 1, 2, 3 AND 8 FOR INFORMATION ON DAYLIGHT OPENING, GLASS TYPES AND SIZE \ LIMITATIONS DEZIGNER (4) X #325 SEXBOLTS (MOUNTED ON OPPOSITE DOOR FACE) FASTEN TOP AND BOTTOM LATCHES TO DOOR 299F/499F TOP STRIKE (STEEL) (MOUNTED WITH (7) #1/4-20 MS) MOUNTED WITH (3) #10-24 SMS Fu MIN.=120 KSi Tl-- TOP LATCH MECHANISM CASE TOP ROD CENTERCASE `y AUX. LATCH n 299-F (499-F) PUSHBAR STRIKE o �. MOUNTED WITH #10-24 SMS 299F STRIKE BOTTOM ROD Fu=120,000 PSI LATCH BOLT BOTTOM LATCH HENO RADIUS 304L BOTTOM STRIKE (STEEL) GROUTED INTO FLOOR � Twmn Aura c VON DUPRIN 98/9957 & 98/9957-F THREE POINT EXIT DEVICE USED IN DOOR CONFIGURATIONS 5 & 6 (SEE SHT.1) CH YMF K JPD 7.5" MIN 6' MIN. EXTERIOR SIDE STEEL TRIM (OPTIONAL) SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 SECTION R-R HORIZONTAL MID -RAIL 12 GAGE MID RAIL REINFORCING CHANNEL 20 18 GA CUTOUT REINFORCING CHANNEL #6-18 X 1 1/4 OHSMS _.N I11IIlf/i. _ 5 M07 EXIT HARDWARE FOR GLASS SINGLE DOORS CUATE AGATE IRGS07 SIZE FLAT DWG N0. E.ATE 11/15/07 SCALES N T S I A U T ❑CAD SH OF 10-f 16 C #10-24 MS 338 TOP STRIKE �"'" ,pn,�� 3788 TOP STRIKE MOUNTED WITH r- Fu MI SMS MN:.=120 KSI 1.55 TOP ROD MECHANISM CASE TOP LATCH �2 qy TOP LATCH 338 STRIKE TOP ROD CENTERCASE MECHANISM CASE CENTERCASE 4DEVICE CENTERCASE THRUBOLTED TO EXTERIOR TRIM (NOT SHOWN) WITH (4) #10-24 MS PUSHBAR �1a..i, �FEATURES BOTTOM ROD D II MECHANISM CASE BOTTOM LATCH 35 SERIES FEATURES SMOOTH MECHANISM CASE rLL 385A OR 304E BOTTOM STRIKE (STEEL) VON DUPRIN SERIES 33/3547A—F & HH33/3547 CONCEALED VERTICAL ROD EXIT DEVICE WITH 2-3/4" BACKSET USED IN COMFIGURATION 4 #10-24 MS 338 TOP STRIKE 55 - TOP LATCH 338 STRIKE TOP ROD MECHANISM CASE CENTERCASE DEVICE CENTERCASE THRUBOLTED TO EXTERIOR TRIM 711HBA��l(NOT SHOWN) WITH (4) #10-24 MS BOTTOM ROD pp � BOTTOM LATCH 385A OR 304E �N BOTTOM STRIKE (STEEL) GROUTED INTO FLOOR ffi VON DUPRIN 98/9947—F & HH98/9947 CONCEALED VERTICAL ROD EXIT DEVICE WITH 2-3/4" BACKSET USED IN CONFIGURATION 4 TOUCHBAR 825 - 2.250 BOTTOM ROD 3788 STRIKE BOTTOM LATCH 2130 BOTTOM STRIKE GROUTED INTO FLOOR FALCON F-25-V & 25-V, SURFACE VERTICAL ROD EXIT DEVICE USED IN DOOR CONFIGURATION 3 (SEE SHTA) 4188 TOP STRIKE �Q` OUNTED WITH TOP ROD — )#10-24 MS TOP LATCH CENTERCASE TOUCHBAR ITTOM ROD NOTES: R E V I S 1. INSTALLATION AND FIRE RATINGS ARE NOT PART OF THIS APPROVAL, TO BE REVIEWED AND APPROVED BY BUILDING OFFICIAL LTR DESCRIPTION A APPROVAL DWG YMF 2. EXIT HARDWARE OPTIONS: FOR 98199 & XP98/99 SERIES - OPTIONS E, RX, LX, SS, EL, G REVISED DWG YMF OEL, CX, F, ALK, CD, PN (OPTIONS MAY VARY PER SERIES) TRIMS: ALL APPLICABLE TRIMS AVAILABLE. PN MODEL OFFERED. H REVISED NAME JPD J REVISED DWG JPD FOR 33/35-F SERIES - OPTIONS RX, LX, EL, CIEL, SS, E, CX, F, ALK, CD, PN, LID TRIM: ALL APPLICABLE TRIMS AVAILABLE. K REVISED DWG JPD L REVISED DWG JPD FOR 2670 GUARD-X TRIM: ALL APPLICABLE TRIMS AVAILABLE. M ENGINEER CHANGE LMS F-25-C & (F)25V SERIES - OPTIONS AE, DM, LM, KOR, MEL, EA, FSA, FSE, CD, RX, LD TRIMS: ALL APPLICABLE TRIM AVAILABLE IN REVISED DWG JPD 0 LOCK UPDATE YC 1/4-20 STEEL MACHINE SCREWS 267 STRIKE 4 PLACES SEX BOLTS 4 PLACES ME �.- AGgN�Y E 1/4-20 STEEL WI -� MACHINE SCREWS IL SOUND ONLY 4 PLACES DATE I APPROVED VON DUPRIN SERIES 2670 GAURD-X USED IN CONFIGURATIONS: 10 & 10A MIN. 3T 247, 14-028) BOTTOM BOLT 4188 STRIKE GUIDE 2130 BOTTOM ® STRIKE GROUTED ��INTO FLOOR 1J FALCON F-25-C, CONCEALED VERTICAL ROD EXIT DEVICE USED IN DOOR CONFIGURATION 4 (SEE SHT.1) 4X #425 SEX BOLTS (DEVICE THRU BOLTED WITH MECHANISM CASE `#10-24 MACHINE SCREWS) OQ AUX. LATCH 909/954 q STRIKE TOUCHBAR MOUNTED WITH V _(3) #10-24 MS Fu=120,000 PSI LATCH BOLT VON DUPRIN XP98/99 & XP98/99— USED IN CONFIGURATIONS 9 & 9A #B-32 MS #12-24 MS Fu m1n=120,000 PSI SCHLAGE ALX-SERIES CYLINDRICAL LOCKSET USED IN DOOR CONFIGURATIONS 2 & 12 (SEE SHT.1) 3 FBPE BEND RA➢IUS mm OF SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET -�- CARMEL, IN 46032 TT THIRD ANGLE PROJECTION TITLE. STEELCRAFT H SERIES SINGLE OUTSWING GLAZED COMMERCIAL STEEL DOORS WITH AN: SWN DATE WITHOUT PANIC EXIT DEVICES YMF 06 M01 HARDWARE OPTIONS FOR GLASS SINGLE DOORS. ECKEI DROVED SIZE FLAT DWG N0. REV IRGS07 G. APPVL JPD Lv15/07 SCALE. N T S I A U T ❑CAD SHEET 11 aP 16 MIN. THROW: LATCH = 1/2" ® s. #8-32 MACHINE SCREWS #12-24 MACHINE SCREWS Fu min=120,000 PSI SCHLAGE NDE AND NDEB-SERIES CYLINDRICAL LOCKSET WITH 1/2'. THROW LATCH USED IN DOOR CONFIGURATIONS 2 & 12 (SEE SHT.1) ( MIN. THROW: "O�•� LATCH = 1/2" O � #5-32 MS MS Fu min-120,000 PSI SCHLAGE D/ND-SERIES CYLINDRICAL LOCKSET USED IN DOOR CONFIGURATIONS 2 & 12 (SEE SHTA) MIN. THROW: LATCH = 1/2" #8-32 MS SS Q Fu=120,000 PSi #12-24 MS SS Fu=122-2 PSivad FALCON T-SERIES CYLINDRICAL LOCKSET USED IN DOOR CONFIGURATIONS 2 & 12 (SEE SHT.1) MIN. THROW: LATCH = 3/4" min 12-24 MS o. # a Fu i 120,000 PSi � u 7- IIN. THROW: )EADBOLT = 1" -ATCH = 3/4" #1 Fu min- MIN. THROW: DEADBOLT = 1" LATCH = 3/4" �u GREENWICH TRIM ADDISON TRIM II®®� 01 ADDISON TRIM SCHLAGE L/LV 9400 SERIES MORTISE LOCKSET WITH DEADBOLT FUNCTION SCHLAGE LE-MD/LEB-MD SERIES MORTISE LOCKSET WITH DEADBOL USED INDOOR CONFIGURATIONS 1 & 11 (SEE SHTA) FUNCTION USED IN DOOR CONFIGURATIONS 1 & II(SHT.1) MIN. THROW: IN LT LATCH LATCH DEADBO= 3 #12-24 MS SS Fu=120,000 Psi 0 FALCON M/MA-SERIES MORTISE LOCKSET WITH DEADBOLT FUNCTION USED IN DOOR CONFIGURATIONS 1 & 11 (SEE SHT.1) MIN. THROW LATCH = 3 #12-24 MS SS Fu=120,000 PSI C� O W = 1" YI MIN. THROW: V LATCH = 3/4" /4" orElt, 'qm� /4" FALCON M/MA-SERIES MORTISE LOCKSET W/O DEADBOLT FUNCTION USED IN DOOR CONFIGURATIONS 1 & 11 (SEE SHT.1) MIN. THROW: I I• ,� L LATCH = 3/4" L9000 SERIES LOCK MECHANISM #12-24 MS SS Fu=120,000 PSi 9" o � _ LATCH o � SCHLAGE L/LV 9000 SERIES MORTISE LOCKSET WITHOUT DEADBOLT SCHLAGE AD -MS & CO -MS SERIES MORTISE LOCKSET WITHOUT DEADBOLT USED IN DOOR CONFIGURATIONS 1 & 11 (SEE SHT.1) USED IN DOOR CONFIGURATIONS 1 & 11 (SEE SHT.1) R E V I S 1 0 N S DESCRIPTION DATE APPROVED APPROVAL DWG YMF 05/20/07 REVISED DWG YMF 01/04/10 REVISED NAME JPD 04/09/10 REVISED DWG JPD 11/01/13 REVISED DWG JPD 02/01/15 REVISED DWG JPD 06/30/15 ENGINEER CHANGE LMS 12/01/16 REVISED DWG JPD 07/18/18 LOCK UPDATE YC 11/26/19 ADDISON TRIMGREENWIa CH TRIM �� •� ADDISON TRIM ND SERIES LE -MS, LEB-MS, LE-MB, LEB-MB SERIES MORTISE LOCKSET DEADBOLT USED IN DOOR CONFIGURATIONS 1 & 11 SHT.1 MIN. THROW: L9400 SERIES DEADBOLT = 1" LOCK MECHANISM LATCH = 3/4" i DEADBOLT #12-24 MS SSy ( Fy=120,000 PSI IlTS1YW :HLAGE AD -MD & CO -MD SERIES MORTISE LOCKSET WITH DEADBOLT NOTE: 1. FIRE RATINGS ARE NOT PART OF THIS APPROVAL AND ARE TO BE REVIEWED BY THE BUILDING OFFICIAL. 2. ELECTRIFIED FUNCTIONS APPROVED, BUT NOT SHOWN ABOVE. BEND RADIUS MIN. THROW: LATCH = 1/2" ,O CH 1 #8-32 MS Fy min=120 Ksi #12-24 MS Fy min=120 ksi USED IN DOOR CONFIGURATIONS 1 & 12 (SEE SHT.1) SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 `111111111/// =* N 7 7 SA OF �i6�8'E.9 AV A . Pt83 0�00, 0``` FBPE GE�Y AVAUTHOHIUWOII-29M kWN DATE WITH AND WITHOUT PANIC EXIT DEVICES YMF 0 5/20 ro' HARDWARE OPTIONS FOR GLAZED SINGLE DOORS. JPD 110/11/07 1-- NTS I AUTOCAD I RGS07 1201 16 0 MAXIMUM UNIT WIDTH 36" OR 48" MAXIMUM DOOR OPENING WIDTH (SEE NOTE 1) SEE SHT.9 FOR GLAZING 1 TYPE AND TYP. THICKNESS 1.75' i / I— DLO —{ 7 e\ EXTERIOR 5 CONFIGURATION 1 & 11 9 MORTISE LOCKSET SECTION A —A MAXIMUM DOOR OPENING WIDTH (SEE NOTE 1) 1 SEE SHT.9 FOR GLAZING TYPE AND TYP. THICKNESS 1.75" DLO �{ EXTERIO 6 7 \ 5 CONFIGURATION 2 & 12 \ 9 CYLINDRICAL LOCKSET SECTION A —A MAXIMUM DOOR OPENING WIDTH (SEE NOTE 1) SEE SHT.9 FOR GLAZING TYPE AND TYP. THICKNESS �J 5 EXTERIOR 17s 7 CONFIGURATION 3 SURFACE VERTICAL ROD EXIT DEVICE. SECTION A —A MAXIMUM DOOR OPENING WIDTH (SEE NOTE 1) //--c 7 .7 SEE SHT.9 FOR GLAZING TYPE AND TYP. THICKNESS \I \\ DLO a EXTERIOR 1.75• CONFIGURATIONS 10 & 10A EXIT ALARM LOCK. SECTION A —A —MAXIMUM UNIT WIDTH 36" OR 48" MAXIMUM DOOR OPENING WIDTH (SEE NOTE 1) 11 7 FOR TYP. F— DLO —I 6 1.75' EXTERIOR 7 CONFIGURATION 4 CONCEALED VERTICAL ROD EXIT DEVICE. SECTION A —A MAXIMUM DOOR OPENING WIDTH (SEE NOTE 1) t1 SEE SHT.9 FOR GLAZING TYPE AND TYP. THICKNESS 1.75' J EXTERIOR � CONFIGURATION 5 & 6 THREE—POINT LATCHING EXIT DEVICE. SECTION A —A MAXIMUM DOOR OPENING WIDTH (SEE NOTE 1) 1 SEE SHT.9 FOR GLAZING TYPE AND TYP. THICKNESS \ �sl DLO — \\���J EXTERIOR 1-75' o_/ CONFIGURATION 7.8.9 & 9A NOTES: RIM EXIT DEVICE. 1. FOR MAXIMUM DOOR OPENING AND GLASS (DLO) SECTION A —A SIZE, SEE TABLE 1 ON SHEET 2 AND SHEETS 8 & 9 FOR LIMITATIONS. 2. SEE SHEET 4 FOR ANCHOR INSTALLATION AND SILL INSTALLATION DETAILS 7 BEND RADIUS LTR DESCRIPTION DATE APPROVED A APPROVAL DWG YMF 05/20/07 G REVISED DWG YMF 01/04/10 H REVISED NAME JPD 04/09/10 J REVISED DWG JPD 11/01/13 K REVISED DWG JPD 02/01/15 L REVISED DWG JPD 06/30/15 M ENGINEER CHANGE LMS 12/01/16 N REVISED DWG JPD 07/18/18 0 LOCK UPDATE YC 11/26/19 �* N 7 7 O� SA OF ,gyp, �[/ ([/ i ,'/ 0 REtt.' '.1[� E. OPS lf7 \\` H B L 330oA FBPE CERY! OV AU31d RIZATON NO. 29578 SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 THIRD ANGLE PROJECTION TITLE: STEELCRAFT H SERIES SINGLE OUTSWING GLAZED COMMERCIAL STEEL DOORS WITH AND AWN DATE WITHOUT PANIC EXIT DEVICES YMF 05/20707 HORIZONTAL CROSS SECTIONS FOR GLASS SINGLE DOORS. ECKED PROVED SIZE FLAT DWG NO. REV IRGS07 0 G. APPVL JPD 11/15/07 NTS I AUTOCAD I ISHEET 13 cf 16 CONCRETE 2" MIN. CONCRETE 2' MIN. CONCRETE 2' MIN. LINTEL . LINTEL LINTELMA (SHOWN) . .� SHEET MAIL .. SHEET ($HONK 1 .. 4" ET 2 h. SEE (SHOWN) SEE SHEET 2 SHEEf 2 SHEET 2 1 �J r1.75-* if]F810@6 1.75' 1.75•rn rnO 00 CD N N 2 2 �W �W �W O (7 OW SW XW 00 W W (7U) = x x H-Z LU SZ 2Z 11 W Z Z Z ° ® 11 (9°OEJ = W W _> Z W Z W CONFIGURATIONS 2& 12 Z 0 11 CL W W Do CONFIGURATIONS 1& 11 W 00 CYLINDRICAL LOCKSET O 0 H W CL Q MORTISE LOCKSET d Q SECTION B-B = 0 0= Z O F SECTION B-B O F O O 7 W W W wW O CONFIGURATION 3 0 W O W O W 0 SURFACE VERTICAL H 1 0 Y 18 X ROD EXIT DEVICE X 0 0 Q SECTION B-B Q X X 0 0 18 1 i6 6 , 15 15 6 SEE SHT.3 FOR SILL SEE SHT.3 FOR SILL SEE SH7.3 FOR SILL INSTALLATION INSTALLATION INSTALLATION 1.25" MIN EMBED . 1.25" MIN. E.D. WOOD 1.25" MIN EMBED . f 1.25' MIN. E.D. WOOD 1.25' MIN EMBED 1.25" MIN. E.D. WOOD 1.21 E.D. E.D. 2.5 MIIN. E.D. CONCRETE E.D. E.D. 2.5 MIIN. E.D. CONCRETE D. E.D.• 2.5" MIIN. E.D. CONCRETE FLOOR LATCHING DETAIL SURFACE —CAL ROD EXIT DE%IT OENCE CONCRETE LINTEL y MIN. 4' MAX, CONCRETE LINTEL 2• MIN, 4' MAX, CONCRETE LINTEL 2" MIN. (SHOWN) .• SEE SHEET 2 (SHOWN): '. .• SEE SHEET 2 (SHOWN) 4' SEE SEE O ( O � - CO W H 00 C Z =0 OF S Eu LU F J E Z W Z) W E W � � C SHEET 2 ® ,6 ,s 16 EXTERIOR EXTEBLOfl EXTERIOR 1.75' 1.75' 0 75' w tp H 2 W F W (7 U) C7 U) 2 o =Z (, zw z „ ,w zW w a im wm 0 I H L 6 O 0 W TCHING K LU CONFlG )RATION 7.8.9 & 9A O j W EXIT DEVICE. W 1 SECTION B-B O RIM EXIT DEVICE. CONFGURATIONS 10 & 10A O SECT ON B-B x EXIT ALARM LOCK. 1 C] Q SECTION B-B 10 ,o ^ 16r,_o 6 1 ( , 15 �Vy SEE SHT.3 SEE SHT.3 / SEE SHT.3 SILL FOR SILL FOR SIIJ_ N�STALLATON INSTALLATION INSTALLATION 1.25" MIN EMBED .— 1.25' MIN. E.D. WOOD 1.25" MIN EMBED . 1.25' MIN. E.D. WOOD 1.25" MIN EMBED . 1.25" MIN. E.D. WOOD E.D. , E.D. 2.5' MIIN. E.D. CONCRETE E.. E.D. 2.5 MIIN. E.D. CONCRETE E . E.D. 2.5" MIIN. E.D. CONCRETE 2' MIN, 4' MA%. SEE - SHEET 2 1 —1.75" 11 R E V I S 1 0 N S DESCRIPTION DATE APPROVED APPROVAL DWG YMF 05/20/07 REVISED DWG YMF 01/04/10 REVISED NAME JPD 04/09/10 REVISED DWG JPD 11/01/13 REVISED DWG JPD 02/01/15 REVISED DWG JPD 06/30/15 ENGINEER CHANGE LMS 12/01/16 REVISED DWG JPD 07/18/18 LOCK UPDATE YC 11/26/19 MIN LATCH THROW TGP-3/4- wmm-1/r CONFlGURATION 4 �i iw uwn BOTTOM LATCH CONCEALED VERTICAL ROD EXIT DEVICE. SECTION B-B THRESHOLD THRESH G p. 4. 4 < /�(2vtl BOTTpA STRKE BOTTW SiPoNE GROUTED INTO FLOOR GRWTED INTO FLOOR SEE SHT.3 FOR SILL FLOOR LATCHING DETAIL INSTALLATION FLOOR LATCHING DETAIL CONCEALED VERTICAL ROD SURFACE VERTICAL ROD EXIT DEVICE C.2N. EA. WOOD F_XIT DEVICE E.D. N. E.D. CONCRETE FLDOR LATCHING DETAIL CONCE_ _TCAL R00 EXIT DEMCE NOTES: 1. FOR MAXIMUM DOOR OPENING SIZE AND GLASS (DLO) SIZE, SEE TABLE 1 ON SHEET 2 AND SHEETS 8 & 9 FOR LIMITATIONS. 2. SEE SHEET 4 FOR ANCHORS INSTALLATION AND SILL INSTALLATION DETAILS. S A OF H B3 DEEA..N L FBPE CERY!0/ I 110N NO. 29578 BEND RADIUS SCHLAGE LOCK COMPANY, LLC 11819 N, PENNSYLVANIA STREET CARMEL, IN 46032 �- THIRD ANGLE PROJECTION TITLE: STELLCRAFT H SERIES SINGLE OUTSWING GLAZED COMMERCIAL WITHOUT PANIC EXIT DEVICES STEEL DOORS WITH AND AW1N DATE YMF 05/20/07 VERTICAL CROSS SECTIONS FOR GLASS SINGLE DOORS. =CKED 'ROVED SIZE FLAT DWG NO. RGSO7 REV 0 ;. APPVL JPD 11/15/07 SCALE` NTS I AUTOCAD SHEET 14 OI 16 1.5• MIr A SECTION AA -AA • • • • ii 4� • 5' MII (A) EXPANDED POLYSTYRENE FOAM DENSITY: 1.0 LBS/FT3 SECTION DD-DD D 1 E SECTION BB -BB agapi-•-s OOPPPP- - (B) POLYISOCYANURATE (POLYURETHANE) DENSITY:2 LBS/FT3 SECTION EE-EE ^SEE DETAIL'V7' OR 'V2' SECTION CC -CC CC C( ,5• MIr F (C) STEEL STIFFENED HAT SHAPED SECTION SECTION FF-FF J F D) HONEYCOMB (E) TEMPERATURE RISE CORE (F) EXPANDED POLYSTYRENE FOAM KRAFT PAPER. MINERAL FIBER BOARD EPS DENSITY:1.0 LB/FT3 DENSITY:17t1.5 LBS/FT3 OR POLYISOCYANURATE OR (POLYURETHANE) PSL P250C-60 CORE DENSITY:2 LBS/FT3 OR CALCIUM SILICATE MINERAL CORE NOTES: 1. CORE MATERIAL SHOWN WITHOUT CUTOUTS FOR REINFORCEMENTS R E V I S 10 N S LTR DESCRIPTION DATE APPROVED DETAIL'41' 22GA. HAT SHAPED A APPROVAL DWG YMF 05/20/07 STIFFENERS SPOTWELDED G REVISED DWG YMF 01/04/10 6" O.C. TO INSIDE OF i.�s FACE SHEETS AND WELDED TOGETHER H REVISED NAME JPD 04/09/10 exo AT TOP AND BOTTOM J REVISED DWG JPD 11/01/13 K REVISED DWG JPD 02/01/15 L REVISED DWG JPD 06/30/15 SECTION CC -CC M ENGINEER CHANGE LMS 12/01/16 DETAIL'V 2' 20GA. HAT SHAPED STIFFENERS SPOTWELDED N REVISED DWG JPD 07/18/18 6" O.C. TO INSIDE OF ONE 1.75 FACE SHEET ❑ LOCK UPDATE YC 11/26/19 AND BONDED TO THE OTHER FACE SHEET 1.63' SECTION CC -CC mm 1 SlAX OF 1: Z BEND RA➢IUS SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET Klk\ —EEa_ CARMEL, IN 46032 THIRD ANGLE PROJECTION TITLE: STEELCRAFT H SERIES SINGLE OUTSWING GLAZED COMMERCIAL STEEL DOORS WITH AND SWN DATE WITHOUT PANIC EXIT DEVICES JPD 03/03/14 DOOR CORE OPTIONS -CKED 'ROVED SIZE FLAT DWG NO. REV IRGS07 ❑ 3. APPVL SCALE' N T S I A U T ❑CAD I ISHEET 15 uF 16 BUTT HINGE 4.5" X 4.5" STD. WT. MIN. #12-24 MACHINE IVES 5BB1/3CB1 SCREWS STANLEY FBB179/1900 HAGER BB1279 0� .134" MIN. THICKNESS Fy MIN. = 36ksi / 4.5" MIN. O o 0 0 0 0 CONTINUOUS HINGE IVES 112HD, 112XY, 224HD & 224XY STANLEY 661HD SELECT SL11HD 96" PEMKO FM —HD SERIES MAX. HAGER 780-224HD ABH A240HD ALUMINUM 6036—T6 MIN .110" MIN. THICKNESS STEEL CONTINUOUS Hli` IVES 600 .075 (14GA) MIN. THCK 1012 COLD ROLLED STE Fy MIN. 45ksi STAINLESS STEEL CON1 IVES 700, 700CS HAGER 790-900 MARKAR FM-300 & H( ABH A500 .075" (14GA) MIN. THIC 304 STAINLESS STEEL Fy MIN. 31ksi CONTINUOUS HINGE NOTES: 1. QUANTITY OF SCREWS VARIES PER HINGE LENGTH, MANUFACTURER AND MODEL NUMBER 2. SCREW SPACING VARIES PER HINGE LENGTH, MANUFACTURER AND MODEL NUMBER 3. INSTALL HINGES PER THE MANUFACTURERS INSTALLATION INSTRUCTIONS (15 MIN.) 12-240/4"FLAT HEAD UNDERCUT SELF DRILLING SCREW DOOR AND FRAME LEAF QUANTITY VARIES PER HINGE o LENGTH N.) #10-24X 1/2" MIN. NE SCREW OR SELF VG EACH HINGE LEAF PITY VARIES PER HINGE H R E V I S 1 0 N S DESCRIPTION DATE APPROVED APPROVAL DWG YMF 05/20/07 REVISED DWG YMF 01/04/10 REVISED NAME JPD 04/09/10 REVISED DWG JPD 11 /01 /13 REVISED DWG JPD 02/01/15 REVISED DWG JPD 06/30/15 ENGINEER CHANGE LMS 12/01/16 REVISED DWG JPD 07/18/18 LOCK UPDATE YC 11/26/19 mm SlAX OF FBPE CERV OP AUTWOR12A160 NO. 295781 BEND RADIUS SCHLAGE LOCK COMPANY, LLC 11819 N. PENNSYLVANIA STREET CARMEL, IN 46032 J DATE WITHOUT PANIC EXIT DEVICES JPD 02/03/14 HINGE OPTIONS IRGS07 10 NTS AUTOCAD I I SHT 16 OF 16