HomeMy WebLinkAboutWIND SPEED & EXPOSURE;% "CONTRACTOR: WYNNE BUILDING CORP DESIGN CRITERIA: Applicable Codes, Regulations, and Standards 1. The 7th Edition (2020) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and AA ADMI Specifications for Aluminum Stmctures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-16. Loading Criteria 1. Live Load: 10 PSF per 7th Edition (2020) Florida Building Code, Appendix I Section 105.1 2. Dead Load: 1 PSF 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 3.2. Ultimate Design Wind Speed: Vur.T =150 MPH, Nominal Design Wind Speed: VAO =116 MPH 3.3. Exposure Category, Section 1609.4.3: Exposure B 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1 - Patio Cover / Screen Room: Non -Habitable, Unconditioned Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.024" Elite 2000 Composite Panel,1.0 # density foam, Florida Product Approval Number FL 7561-R5. Foundation Design Existing concrete slab. No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spalling, or other deterioration. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 7th Edition (2020) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Florida Aluminum Engineering, Inc. 3. Screen material shall be 18/14 screen unless approved by Florida Aluminum Engineering, Inc. 4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 5. Approved concrete screw anchors to be Simpson Titcn-HD or equivalent. 6. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or #12 screws 6" from ends and 12" center to center. 7. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 I Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1% - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM Al85 c. Concrete slump at discharge chute not less than 3" or more than 511. Water added after batching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 8. All flashing and weatherproofmg shall be provided by the contractor. 9. Door location shall be determined by contractor in the field. 10. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED AND EXPOSURE HAVE BEEN DETERMINED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. imp f 7'-3" , 1 ,- 7'-3" ro 00 I 1 00 00 O I 16'-0" 1'-0" O 1 M LL. b, Q ;Z o 0 a; LU :v oc 0, ''•.,�°� •.......• Quo,` IL 3"X48"X0.024" 1.0# DENSITY FOAM COMPOSITE PANEL O 3X3XO.090 0 3X3XO.090 M N C 2X3GIRT M (T'�) EMI I;��I�O �,�P►N,C•>i CO uN 16" ALUIMINUM p� �� GO KICKPLATE coO •`®GCj (TYPICAL) a 6'-41" 3'-3" 6'-41" W UJ W Z m W Z J = Z . Z O n' vWi t/1 4 w LU C, J U- O O t1 8 i0 C c=/ N Z Ci Z Z W �� MW 5 Z Cgi^3 J 7 r` ; P. t; Q W w.gMM u�+ Q W L2WS °C z OZ$co w W LJ o (A W Of 0 � o Q tYZU W ZgOf W �Oa- LLJ 0 W o � d (0 OL U- DRAWN BY TP 12/02/21 REVISION 1J 1 2X3X0.045 2X3X0.045 EDGE BEAM EDGE BEAM 3"X48"X0,024" 1.0# DENSITY FOAM COMPOSITE PANEL 2X3X0.070 SHEET NO: A-1 ALUMINUM MEMBERS DIMENSIONS oIl� sW HOLLOW SECTIONS 1/8" x 2" x 2" EXTRUDED I KICK PLATE NOTES: \``,,,`1�111/1 \\\ ,,,.�,n', 2 x 2: 2" x 2" x 0.046" ANGLE 5052 H-32 ALLOY EA SIDE W/ #14 3/4" SMS 1. 0.024 ALUM `\\ .•�� •� 2 x 3: 2" x 3" x 0.050" (4) x o m 2. SCREW ALL CORNERS _ • . ♦♦ 2 x 4: 2" x 4" X 0.050" INTO UPRIGHT o o 3. 100 B - 120 B WIND ZONES o � M�1 ` LL b'% I 2 x 5: 2" x 5" x 0.050" USE #8 x 5/8" SMS @ 12" O.C. Q (� O 4 • + 4. 120 C- 140 B WIND ZONES M Z O r OPEN BACK SECTIONS y _ 11/4' MIN CONCe yANCHO USE #8 x 5/8" SMS @ 8" O.C. 5. 140 C - 150 B WIND ZONES a W (o + . II,, �}' • v H p_ Q + Q 1 x 2: 1" X 2" X 0.040" �' X I EM IEDM + ° USE #8 x 5/8" SMS @ 6" O.C. I N �• � Q 1 x 3: 1" X 3" X 0.045" • y �--�� 6. 150 C & ABOVE WIND ZONES I. wr� �•� 4, ' USE #12 x 5/8" SMS @ 6" O.C. 7. SCREW GIRT, BOTTOM RAIL Z ♦ v '. i •�� SNAP SECTIONS °. -' y ' ' ° • ' ; 'e' ° a • , ' & BOTH SIDES I •• ♦/ �t" •• .•'� \\ 2 x 2 Snap: 2" x 2" x 0.045" ' <, • , 2" MIN EDGE DISTANCE FROM 8. MAX KICK PLATE HT = 36" ' I //// • r `� •' • • Q \\\ Q� 2 x 3 Snap: 2" x 3" x 0.050" 2 x 4 Snap: 2" X 4" x 0.045" „a TING • o ° u EXTERIOR OF COLUMNO IORDE // ,����hIU ,�\ *111►/�,,,,1j SEE PLAN '; a ,a' ° a ' SLAB I I SELF MATING (SMB) SIDE VIEW 2 x 4 SMB: 2" x 4" x 0.044" x 0.100" CHAIR RAIL MEMBER I i 2 x 5 SMB: 2" x 5" x 0.050"x 0.100" W LLI 2 x 6 SMB: 2" x 6" x 0.050"x 0.120" - - - - - - - W Z 2 x 7 SMB: 2" x 7" x 0.05T'x 0.120" (2) 3lS DIE. CONCRETE z 2 x 8 SMB: 2" x 8" x 0.072"x 0.124" SCREW ANCHORS I I UPRIGHT - - - I I - Z �p 2 x 9 SMB: 2" x 9" x 0.072"x 0.124" (21/4" CONC. EMBED) W Z et 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" J 1"x 1"x 1/8" ANGLE W/AI Q Q Z IM MINUM FASTENER EDGE DISTANCE: 1/2" - - - - - - - - 1"x 2" BASE (2) #14 x 5/8" EACH FLANGE I I Z d MINIMUM FASTENER SPACING: 3/4" - - _ _ PLATE a ANCHORED TO CONC W/ 1/4" EACH SIDE OF UPRIGHT Q H (ry Z 11/a•MlN cauc < a CONCRETE SCREW ANCHOR ' UPRIGHT Q W CONCRETE SCREW ANCHOR: EMBEDMENT ° ? : ° (MIN. 1 1/4" EMBED) I LLu - J SIMPSON TITEN HD ORE DIVALENT Q 21l4 MIN CONC • • a. ', , ° '° y 6" MAX EACH SIDE OF POST ° LL SHEET METAL SCREWS (SMS): ME EMBEDMENT ! • . ° ' y AND 24" O.C. MAX O T ITW / BUILDEX OR EQUIVALENTI-- ° y 4 d ' SLAB / FOOTING • 4 ' '• ' ° ° v. 6• ° ` SEE PLAN 4 P FRONT VIEW = Z z Z W B 2" x 3" PB UPRIGHT TO CONCRETE DETAIL C CHAIR RAIL TO POST CONNECTION DETAIL m 10 z A-Z SCALE: NTS A-2 SCALE: NTS Z Glm^ ��;; Nq � Q W C Q ••q "r1 W n Go3!D z W Z z Z �I m 118" x 2" x 2" EXTRUDED J LU e i 1" x 3" OPEN BACK STITCHED ANGLE 5052 H-32 ALLOY I V- TO 3" x 3" POST WI (1) #12 x 1 1/2" W/ (4) #14 x 3/4" SMS---, @ 12" O.C. W/ 1 ST 6" INTO DJ a o FROM CONCRETE 3" x 3" x 0.093" POST- y •d4. y I I 21/4• MIN CONC u r ° 'ANCHOR EM13EDMDO SLAB FOOTING °' , WOOD: SEE PLAN 1/4" DIA. x 3" WOOD SCREWS, ° ' •° 4y •4 y ' 6" FROM GIRT & @ 12" O.C. CO CONC: 1" x 3" OPEN BACK STITCHED s ' DIA. x 3" CONCRETE BEHIND 3" x 3" POST 1" x 3" OPEN BACK STITCHED W/ 1 ; • ,y. , a ' , • W cc SCREW ANCHOR, 6" W/ (1) #12 x 1 112" TO 3" x 3" POST (1) #12 x 1/2" 1z" o.c. wr lsr s" Z) 0 FROM GIRT 8 @ 24" O.C. @ 12" O.C. W/ IS' @ SIDE VIEW FROM CONCRETE I FROM CONCRETE U (4) #10 x 1 1/2" INTO Q W SCREW BOSS 3" x 3" x 0.093" I D_ Z U b Z _ POST (1) 3/8" DIA. CONCRETE j/ !9- W J O d o SCREW ANCHORS UPRIGHT � W � I- INTERNAL/EXTERNAL 3" x 3' x EXTRUDED I 1 " x 3" OB W/ 1/4" CONCRETE (2 1/4" CONC. EMBED) I PRE -HUNG LL �P W D' m o POST BASE W/ (2) 318" AS I SCREW ANCHOR 6" � I DOOR JAMB O J � �. � LL LL DIA. THRU BOLTS FROM UPRIGHT & @ DRAWN BY 4r 24" O.C. (MIN. 3" EMBED.) - ` - 2" x 2" OR 2" x 3" HOLLOW TP I SECTION GIRT A DATE DRAWN - 1"x 2" ° .y 1"x 3" BASE PLATE o y' 2ro2i21 ANCHORED TO CONC W/ 1/4" (2) 3/8" DIA. CONCRETE e ° 4 , e CONCRETE SCREW ANCHOR < ;• d y o (MIN. 1 1/4" EMBED) 'd' REVISION 1Q SCREW ANCHORS (3" CONC. EMBED) e' y 4 a " 4' ' 6" MAX EACH SIDE OF POST °• y4• ° AND 24" O.C. MAX • `6"' a'° a ' �� = qp G - C-, FRONT VIEW ®� 1X2 TO HOST STRUCTURE DETAIL 4 - SHEET NO: A_2 SCALE: NTS CP-1 3" x 3" POST TO CONCRETE CONNECTION DETAILS DJ_ UPRIGHT TO CONCRET PRE HUNG A-2 SCALE: NTS /4_2 DOOR LOCATION DETAIL A-2j SCALE:NTS #14 x 4" SMS W/ CO " COMPOSITE 1 1/2" DIA. NEOPRENE 33" CO NEL FACED WASHER @ 6" O.C. #14 SMS x 1" MIN. LONGER THAN PANEL W/ 1 1/2" DIA. NEOPRENE FACED WASHER @ 12" O.C. ALONG LENGTH _,?;:rt'r .yL'•. �� tCe:3*1"' ::":.� OF ALL END BEAMS 3" x 0.062" ALUM�)ii ° `s�,,'K''•'�.;K'�aY,t`( n9.. ,..tie RECEIVING CHANNEL h�ef<i\ 1Y, p(y,.. k; %>;.`i.-.', ',satt"*f+?;.�:]c: �.,.. .4ft.t.. (: ,•C..l,?i ;,".'. .�4 rVrfyyat. W/ #10 x 3/4" TOP AND ?1i . • f •ePcti; A•-. BOTTOM AS END CAP 2" x 3" FLAT TOP RAIL - NO I I 3" COMP ANGLE REQUIRED UNLESS I J PANEL SPLICED OR CORNER - I I ¢ 2" x 3 ATTACH w/ (4) #10 x 4" LG III III I Iz J BEAM i 1� UPRIGHT p81 II I� 10 2" x 3" FLAT III I I 1 Z I LL. TOP RAIL W/ I W (4) #10 x 4" SMS INTO POST 2" x 3" FLAT TOP RAIL w! #10 4" SMS t�•t^4 • is �,: "• �:,^th.;�•� a: � ti'�rr i � ia;r"' e � l: .?q.�y.';*;; '�... ts> �. �. (4) x �7_3's.:"ri� Ha,Fy` . M�;ty dM •. i, jr,'+i°f '�5;� ,r'+•,1.•' �, �•.aYS `:, cl ',^•.' •7J-tn,. �,", ^•i4�>i'5::^n�s.'• '.�.ri-•c. INTO POST ',;:� , o +�!.n• •`far„rr�;*�"vn.�.',rr-;;:�P��",: �: e��l r4`,:;.ra�^!;w �r.;•k;a�,y.,w,,�,"w.,^ �.,�"�:''�' 2" x 'x 3" LG 2" x 2" x 3" LG — x 1 /8" ANGLE -- -- -- — — x 1/8" ANGLE (4) #10 x 3/4" (4) #10 x 3/4" SMS INTO SMSINTO SCREW BOSSES I SCREW BOSSESI (2) INTO TOP RAIL I (2) INTO TOP RAIL I I (2) INTO POST (2) INTO POST CONNECTION AT CORNER CONNECTION AT SPLICE S 2 X 3 TOP RAIL CONNECTION TO UPRIGHT � -3 SCALE: NTS FLASHING - INSTALL UNDER EXISTING DRIP EDGE 3" x 0.062" EXTRUDED RECEIVER CHANNEL #14 x 3/4" SMS @ 6" O.C. TOP AND BOTTOM W/ 1 1/2" DIA. NEOPRENE WASHER @ TOP SCREW ONLY \-1WI DIA. x 3" LAG SCREWS 3" COMPOSITE PANEL @ 12" O.C. S-1 COMPOSITE PANEL TO FASCIA DETAIL A-3 SCALE: NTS 2" x 3" FLAT END BEAM 1 1/2" x 2 1 /8" x 1 1/2" x 3" x 0.062" ALUM RECEIVING CHANNEL W/ (4) #14 x 3/4" SMS EACH SIDE INTO BEAM EXISTING HOST WALL CONCRETE- (2) 1/4" DIA. x 3" QUICKSET ANCHORS INTO WALL WOOD: (2) 1/4" DIA. x 3" LAG SCREWS INTO WALL S-2 BEAM TO HOST STRUCTURE ATTACHMENT DETAIL A-3 SCALE: NTS LL 6 Q •• LL r "ate •W co U 'a' W • �p •• • Z • �tv� \\ IZz cc LLJ W Lu Q. Z M Z W z Q Q O z z o_ Ln N N ¢ W LLLL G J O a n � i m � c Z z i W 5 z J 2LLmm Q UJLU wa�v V�C LL n 0 Z z U. w 6 o 4 J LL . (A LLI I= :D pQ o Q _ z U D w It ui- woxcco D'0-j a H-• CO LL. LL DRAWN BY TP DATE DRAWN 12/02/21 REVISION A _ - 4 - SHEET NO: A-3m