Loading...
HomeMy WebLinkAboutCertification Design Load Compliance`o Planning & Development Services Department Building & Code Regulations Division e. 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1577 ' Project Name: Certification for Design Load Compliance Th Edition VFNTLIRE LAND AND'DEVELOPEMENT SPEC Project Address: 7408 SAN CARLOS DRIVE, FT. PIERCE Permit#: Occupancy Type: R-3 Construction Type: VB ' INSTRUCTIONS FOR USE: This certification musfbe completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format (PDF) version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida BUILDING Code 7th Edition using ASCE 7-16 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I % II III IV Exposure Category: X B C D 4. Design Wind Velocity 160 mph ASD LRFD End Zone Width: 3' ft 5. Mean Roof Height <15� ft Roof Pitch: 5 :12 Parapet: N / A ft 6. Components & Cladding Design Pressures Used: +22"?/-2.4to Garage: 7 .. j Q` *23.3/-26.0 Zone 4: Zone 5: + Z2. 6a. Roofs Maximum +/-pressures: + 16.9 psf - 41.9 psf Or define individual zones on the plans 7. Design Loads: Floor: 40 PSF Roof -Dead: 17 PSF Roof -Live: 20 Balcony+/- N / A PSF Dock: N / A PSF Deck: N /A PSF Stairs: N / A PSF Fence: N / A PSF Railings: N / A PSF 8. Were Shear Walls Considered For Structure? -XYes Not Applicable Please Explain: 9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes No Assumed #sstt�of my knowledge and belief, the attached plans &specifications have been designed to rnr„tiuthielaAsl+ea structural portions of the current Florida Building Code as adopted. � y Signature, Dat�,�► dSeall II -� Revised 1! S O1 N \`\` �5/ TODD N. SMITH P.E. # 42082 / REG # 8772 Print Name Cert # & Co. CertofAuthorization 1717 INDIAN RIVER BLVD., SUITE 302, VERO BEACH, FL. 32960 Company Name & Address