HomeMy WebLinkAboutCertification Design Load Compliance`o Planning & Development Services Department
Building & Code Regulations Division
e.
2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1577
' Project Name:
Certification for Design Load Compliance
Th Edition
VFNTLIRE LAND AND'DEVELOPEMENT SPEC
Project Address: 7408 SAN CARLOS DRIVE, FT. PIERCE
Permit#: Occupancy Type: R-3 Construction Type:
VB '
INSTRUCTIONS FOR USE:
This certification musfbe completed, signed, and sealed by the design professional of record.
• If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally
signed electronic version.
• If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required
• All digital files must be in an unlocked Portable Document Format (PDF) version
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida BUILDING Code 7th Edition using ASCE 7-16
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: I % II III IV Exposure Category: X B C D
4. Design Wind Velocity 160 mph ASD LRFD End Zone Width: 3' ft
5. Mean Roof Height <15� ft Roof Pitch: 5 :12 Parapet: N / A ft
6. Components & Cladding Design Pressures Used:
+22"?/-2.4to Garage: 7 .. j Q` *23.3/-26.0
Zone 4: Zone 5: + Z2.
6a. Roofs
Maximum +/-pressures: + 16.9 psf - 41.9 psf Or define individual zones on the plans
7. Design Loads: Floor: 40 PSF Roof -Dead: 17 PSF Roof -Live: 20 Balcony+/- N / A PSF
Dock: N / A PSF Deck: N /A PSF Stairs: N / A PSF Fence: N / A PSF Railings: N / A PSF
8. Were Shear Walls Considered For Structure? -XYes Not Applicable Please Explain:
9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes No Assumed
#sstt�of my knowledge and belief, the attached plans &specifications have been designed to
rnr„tiuthielaAsl+ea structural portions of the current Florida Building Code as adopted.
� y
Signature, Dat�,�► dSeall
II
-�
Revised 1! S O1 N \`\`
�5/
TODD N. SMITH P.E. # 42082 / REG # 8772
Print Name Cert # & Co. CertofAuthorization
1717 INDIAN RIVER BLVD., SUITE 302, VERO BEACH, FL. 32960
Company Name & Address