HomeMy WebLinkAboutEnergy Efficinecy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
e: Bradescu - 7408 San Carlos Dr
Builder Name:
FStreet:7408 San Carlos Dr
Permit Office: Fort Pierce
ip: Fort Pierce, FL, 34951Permit
Number:
Jurisdiction: 661100
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1274.7 sqft.)
Insulation Area
a. Concrete Block - Int Insul, Exterior
R=4.1 1082.70 ftZ
2. Single family or multiple family Detached
b. Frame - Wood, Adjacent
R=13.0 192.00 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftz '
4. Number of Bedrooms 3
d. N/A
11. Ceiling Types (1282.0 sqft.)
R= ft2
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1282.00 ftz
6. Conditioned floor area above grade (ftZ) 1282
b. N/A
R= ftZ
R= ftZ
Conditioned floor area below grade (ftZ) 0
c. N
R ftZ
7. Windows(173.3 sqft.) Description Area
12. Ducts
a. Sup: Attic, Rat: Attic, AH: AHU
.6 252
a. U-Factor: Dbl, U=0.57 133.62 ftZ
SHGC: SHGC=0.24
b. U-Factor: Dbl, U=0.69 39.64 ftZ
13. Cooling systems
kBt Efficiency
28;4 SEER:15.00
SHGC: SHGC=0.22
a. Central Unit
.4
c. U-Factor: WA ftZ
SHGC:
14, Heating systems
kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 2.395 ft.
a. Electric Heat Pump
28.2 HSPF:8.50
Area Weighted Average SHGC: 0.235
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1282.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1282.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
Pstat
c. N/A R= ftZ
16. Credits
Total Proposed Modified Loads: 43.24
PASS
Glass/Floor Area: 0.135 Total Baseline Loads: 44.35
I hereby certify that the plans and specifications covered by
Review of the plans and
O0'SIiB S�Ap8
this are in compliance with the Florida Energy
specifications covered by this
calculation
Code.
calculation indicates compliance
_
with the Florida Energy Code.
PREPARED BY: 'u� E-Calcs Plus Inc.
Before construction is completed
-lli
DATE: Jul 30 021
this building will be inspected for
compliance with Section 553.908
O i
* �'
`
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
�,. .. �g'S
COD we
with the Florida Energy Code.
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
7/30/2021 2:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INN U I ,UnnmAMT lrl'7ClonL101 r«rvn�
PROJECT
Title: Bradescu - 7408 San Carlos
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1282
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Street:
7408 San Carlos
Dr
Builder Name:
Permit office: Fort Pierce
Rotate Angle: 0
'Cross Ventilation: No
County:
St. Lucie
Jurisdiction: 661100
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
FL, 34951
Family Type: Detached
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating Design Daily Temp'
/
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH _MUNI 39 90
70
75 299
58
Medium
J
BLOCKS
Number Name Area
Volume
1 Entire House 1282 10920.3
- !
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 Laundry 42
336 No 0
1 Yes
Yes
Yes
2 BR 2 143
1144 No 1
1
1 Yes
Yes
Yes
3 BA 2 54
432 No 0
1 Yes
Yes
Yes
4 BR 3 156
1248 No 1
1
1 Yes
Yes
Yes
5 KitLivDin 511
4752.3 Yes 0
1 Yes
Yes
Yes
6 WIC 2 20
160 No 0
1 Yes
Yes
Yes
7 AHU 15
120 No 0
1 Yes
Yes
Yes
8 M BA 54
432 No .0
1 Yes
Yes
Yes
9 M WIC 30
240 No 0
1 Yes
Yes
Yes
10 M BR 182
1456 No 2
1
1 Yes
Yes
Yes
11 Foyer 75
600 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Laundry 7 ft 0
42 ft2
____
1 0
0
2 Slab -On -Grade Edge Insulatio
BR 2 24 ft 0
143 ft'
____
1 0
0
3 Slab -On -Grade Edge Insulatio
BA 2 6 ft 0
54 ftz
____
1 0
0
4 Slab -On -Grade Edge Insulatio
BR 3 25 ft 0
156 ft'
____
1 0
0
5 Slab -On -Grade Edge Insulatio
KitLivDin 44 ft 0
511 ft'
____
1 0
0
. 6 Slab -On -Grade Edge Insulatio
WIC 2 1 ft 0
20 ftz
0
0
7/30/2021 2:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
•rw■/■ ■AT P9rAADT
FORM R405-2020 IIVt'U 1 OUWIWIAMT l.r7C%.nL101 I«rvt`.
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
7 Slab -On -Grade Edge Insulatio AHU 1 ft
0
15 ft2
----
1
0
0
'
8 Slab
-On -Grade Edge Insulatio M BA E ft
0
54 ft2
----
1
0
0
9 Slab -On -Grade Edge Insulatio M WIC 1 ft
0.
30 ft2
----
1
0
0
10SIab-On-Grade Edge Insulatio M BR 31 ft
0
182 ft2
___
1
0
0
11SIab-On-Grade Edge Insulatio Foyer 9 ft
0
75 ft2
\ ----
1
0
0
ROOF
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1389 ft'
0 ftz Medium
N
0.75
No 0.9
No 0
22.62
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1282 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) Laundry
30
Blown
42 ft2
0.1
Wood
2
Under Attic (Vented) BR 2
30
Blown
143 ft2
0.1
Wood
3
Under Attic (Vented) BA 2
30
Blown
54 ft2
0.1
Wood
4
Under Attic (Vented) BR 3
30
Blown
156 ft2
0.1
Wood
5
Under Attic (Vented) KitLivDin
30
Blown
511 ft2
0.1
Wood
6
Under Attic (Vented) WIC 2
30
Blown
20 ft2
0.1
Wood
7
Under Attic (Vented) AHU
30
Blown
15 ft2
0.1
Wood
8
Under Attic (Vented) M BA
30
Blown
54 ft2
0.1
Wood
9
Under Attic (Vented) M WIC
30
Blown
30 ft2
0.1
Wood
10
Under Attic (Vented) M BR
30
Blown
182 ft2
0.1
Wood
11
Under Attic (Vented) Foyer
30
Blown
75 ft2
0.1
Wood
WALLS
Cavity Width
Height
Sheathing Framing Solar
Belo w
Adjacent S ace
PR-Vall
le Et
In Ft
In
Area-
13-Vallie Practenn
Ahsnr
Grade
1
NW
Garage Frame - Wood Laundry
13 7
0 '8
0
56.0 ft2
0
0.23
0.01
0
_
2
SW
Exterior Concrete Block - Int Insul BR 2
4.1 11
0 8
0
88.0 ft2
0
0
0.45
0
_
3
NW
Garage Frame - Wood BR 2
13 13
0 8
0
104.0 ft2
0
0.23
0.01
0
_
4
SW
Exterior Concrete Block - Int Insul BA 2
4.1 6
0 8
0
48.0 ft2
0
0
0.45
0
_
5
SE
Exterior Concrete Block - Int Insul BR 3
4.1 13
0 8
0
104.0 ft2
0
0
0.45
0
_
6
SW
Exterior Concrete Block - Int Insul BR 3 i
4.1 12
0 8
0
96.0 ft2
0
0
0.45
0
_
7
NE
Exterior Concrete Block - Int Insul KitLivDin
4.1 18
0 9
4
168.0 ft2
0
0
0.45
0
8
SE
Exterior Concrete Block - Int Insul KitLivDin
4.1 26
0 9
4
242.7 ft2
0
0
0.45
0
7/30/2021 2:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
r-t'%nRA Mery nn1) IAIDI IT 0I111A11AADV f%uc(`KI ICT D1=DnPT
1 VI\IVI 1%TW-
--
----
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Belo w
Space
Et In Et
in
Area
R-Vqllle -Erat
9
NE
Exterior Concrete Block - Int Insul M BA
4.1 6 0 8
0
48.0 ft2
0
0 0.45
0
_
10
NE
Exterior Concrete Block - Int Insul M BR
4.1 13 0 8
0
104.0 ft2
0
0 0.45
0
11
SW
Exterior Concrete Block - Int Insul M BR
4.1 4 0 8
0
32.0 ft2
0
0 0.45
0
_
12
'NW
Exterior Concrete Block - Int Insul M BR
4.1 14 0 8
0
112.0 ft2
0
0 0.45
0
_
13
NW
Exterior Concrete Block - Int Insul Foyer
4.1 5 0 8
0
40.0 ft2
0
0 0.45
0
14
SW
Garage Frame - Wood Foyer
13 4 0 8
0
32.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value. Ft
In
In
Ft eightln
Area
1
NW Insulated Foyer
None
.54
3
8
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
v
#
Ornt ID Frame Panes NFRC
U-Factor SHGC imp
Area
Depth
Separation
Int Shade
Screening
1
SW 2 Metal Low-E Double Yes
0.57 0.24 N
16.9 ft2
2 ft 0 in
0 ft 6 in
None
None
2
SW 4 Metal Low-E Double Yes
0.57 0.24 N
7.5 ft2
2 ft 0 in
0 ft 6 in
None
None
3
SW 6 Metal Low-E Double Yes
0.57 0.24 N
16.8 ft2
2 ft 0 in
0 ft 6 in
None
None
4
NE 7 Metal Low-E Double Yes
0.57 0.24 N
16.8 ft2
2 ft 0 in
0 ft 6 in
None
None
5
SE 8 Metal Low-E Double Yes
0.57 0.24 N
34.0 ft2
2 ft 0 in
0 ft 6 in
None
None
6
SE 8 Metal Low-E Double Yes
0.69 0.22 N
39.6 ft2
2 ft 0 in
0 ft 6 in
None
None
7
NE 9 Metal Low-E Double Yes
0.57 0.24 N
7.5 ft2
2 ft 0 in
0 ft 6 in
None
None
8
NW 12 Metal Low-E Double Yes
0.67 0.24 N
34.2 W
4 ft 0 in
0 ft 6 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
391 ft2 391 ft2
64 ft
8 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000325
1092 59.91 112.48
.111
6
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ None
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
7/30/2021 2:26 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
r'/'10ILA MAnC )n,)n IAIDI IT CI IMMADV t'%W=f`IfI ICT 12PPnRT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
'Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Sing[ SEER: 15 28.4 kBtu/hr 852 cfm
0.75
1
sys#1
HOT WATER SYSTEM
. # System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.95 40 gal
60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
--- Supply --
-- Return --
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT ON
RLF
Heat Cool
1 Attic
6 262 ft2
Attic
63 ft2 Default Leakage
AHU
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling r Jan Feb
Heating [X] Jan Feb
Mar
(X] Mar
[ ]Apr [
[ ] [
] Ma ()(] Jun [�] Jul
]May [ j Jun [ ] Jul
[)(] Aug�]
[ ] Au[
Se
] Sep
[ Oct
[ ] Oct
[ ]Nov
[X] Nov
r Dec
[X] Dec
Dec
Venting [[[[ 1111 Jan Feb
[[XX]] Mar
pr
[X] Apr [
] May [ 1 Jun [ ]Jul
[ 1 Aug
[[[ 1 Se
[X] Oct
[X) Nov
[[[ 111
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) PM
80
80 78
78 78 78
8
78
78 80
78 78
78
78
78
Cooling (WEH)
PM
78
78 78
78 78 78
78
78 78
78
78
78
78
Heating (WD) PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH)
PM
66
68
66 66
68 68
66 66 68
68 68 68
68
68
68 68
68 68
68
68
68
66
68
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BR 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BA 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BR 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KitLivD[n
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BA
Default(8lbs/sq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M BR
Default(8 Ibs/s .ft.
ft2
ft
0.3
Foyer