HomeMy WebLinkAboutEnergy Efficinecy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method e: Bradescu - 7408 San Carlos Dr Builder Name: FStreet:7408 San Carlos Dr Permit Office: Fort Pierce ip: Fort Pierce, FL, 34951Permit Number: Jurisdiction: 661100 Design Location: FL, ST LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1274.7 sqft.) Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 1082.70 ftZ 2. Single family or multiple family Detached b. Frame - Wood, Adjacent R=13.0 192.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftz ' 4. Number of Bedrooms 3 d. N/A 11. Ceiling Types (1282.0 sqft.) R= ft2 Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1282.00 ftz 6. Conditioned floor area above grade (ftZ) 1282 b. N/A R= ftZ R= ftZ Conditioned floor area below grade (ftZ) 0 c. N R ftZ 7. Windows(173.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Rat: Attic, AH: AHU .6 252 a. U-Factor: Dbl, U=0.57 133.62 ftZ SHGC: SHGC=0.24 b. U-Factor: Dbl, U=0.69 39.64 ftZ 13. Cooling systems kBt Efficiency 28;4 SEER:15.00 SHGC: SHGC=0.22 a. Central Unit .4 c. U-Factor: WA ftZ SHGC: 14, Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.395 ft. a. Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average SHGC: 0.235 8. Skylights Area c. U-Factor:(AVG) N/A ftZ 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1282.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1282.00 ftZ b. Conservation features b. N/A R= ftZ None Pstat c. N/A R= ftZ 16. Credits Total Proposed Modified Loads: 43.24 PASS Glass/Floor Area: 0.135 Total Baseline Loads: 44.35 I hereby certify that the plans and specifications covered by Review of the plans and O0'SIiB S�Ap8 this are in compliance with the Florida Energy specifications covered by this calculation Code. calculation indicates compliance _ with the Florida Energy Code. PREPARED BY: 'u� E-Calcs Plus Inc. Before construction is completed -lli DATE: Jul 30 021 this building will be inspected for compliance with Section 553.908 O i * �' ` I hereby certify that this building, as designed, is in compliance Florida Statutes. �,. .. �g'S COD we with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). 7/30/2021 2:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INN U I ,UnnmAMT lrl'7ClonL101 r«rvn� PROJECT Title: Bradescu - 7408 San Carlos Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1282 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Street: 7408 San Carlos Dr Builder Name: Permit office: Fort Pierce Rotate Angle: 0 'Cross Ventilation: No County: St. Lucie Jurisdiction: 661100 Whole House Fan: No City, State, Zip: Fort Pierce , FL, 34951 Family Type: Detached New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp' / V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH _MUNI 39 90 70 75 299 58 Medium J BLOCKS Number Name Area Volume 1 Entire House 1282 10920.3 - ! SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Laundry 42 336 No 0 1 Yes Yes Yes 2 BR 2 143 1144 No 1 1 1 Yes Yes Yes 3 BA 2 54 432 No 0 1 Yes Yes Yes 4 BR 3 156 1248 No 1 1 1 Yes Yes Yes 5 KitLivDin 511 4752.3 Yes 0 1 Yes Yes Yes 6 WIC 2 20 160 No 0 1 Yes Yes Yes 7 AHU 15 120 No 0 1 Yes Yes Yes 8 M BA 54 432 No .0 1 Yes Yes Yes 9 M WIC 30 240 No 0 1 Yes Yes Yes 10 M BR 182 1456 No 2 1 1 Yes Yes Yes 11 Foyer 75 600 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Laundry 7 ft 0 42 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulatio BR 2 24 ft 0 143 ft' ____ 1 0 0 3 Slab -On -Grade Edge Insulatio BA 2 6 ft 0 54 ftz ____ 1 0 0 4 Slab -On -Grade Edge Insulatio BR 3 25 ft 0 156 ft' ____ 1 0 0 5 Slab -On -Grade Edge Insulatio KitLivDin 44 ft 0 511 ft' ____ 1 0 0 . 6 Slab -On -Grade Edge Insulatio WIC 2 1 ft 0 20 ftz 0 0 7/30/2021 2:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 •rw■/■ ■AT P9rAADT FORM R405-2020 IIVt'U 1 OUWIWIAMT l.r7C%.nL101 I«rvt`. FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulatio AHU 1 ft 0 15 ft2 ---- 1 0 0 ' 8 Slab -On -Grade Edge Insulatio M BA E ft 0 54 ft2 ---- 1 0 0 9 Slab -On -Grade Edge Insulatio M WIC 1 ft 0. 30 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio M BR 31 ft 0 182 ft2 ___ 1 0 0 11SIab-On-Grade Edge Insulatio Foyer 9 ft 0 75 ft2 \ ---- 1 0 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1389 ft' 0 ftz Medium N 0.75 No 0.9 No 0 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1282 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Laundry 30 Blown 42 ft2 0.1 Wood 2 Under Attic (Vented) BR 2 30 Blown 143 ft2 0.1 Wood 3 Under Attic (Vented) BA 2 30 Blown 54 ft2 0.1 Wood 4 Under Attic (Vented) BR 3 30 Blown 156 ft2 0.1 Wood 5 Under Attic (Vented) KitLivDin 30 Blown 511 ft2 0.1 Wood 6 Under Attic (Vented) WIC 2 30 Blown 20 ft2 0.1 Wood 7 Under Attic (Vented) AHU 30 Blown 15 ft2 0.1 Wood 8 Under Attic (Vented) M BA 30 Blown 54 ft2 0.1 Wood 9 Under Attic (Vented) M WIC 30 Blown 30 ft2 0.1 Wood 10 Under Attic (Vented) M BR 30 Blown 182 ft2 0.1 Wood 11 Under Attic (Vented) Foyer 30 Blown 75 ft2 0.1 Wood WALLS Cavity Width Height Sheathing Framing Solar Belo w Adjacent S ace PR-Vall le Et In Ft In Area- 13-Vallie Practenn Ahsnr Grade 1 NW Garage Frame - Wood Laundry 13 7 0 '8 0 56.0 ft2 0 0.23 0.01 0 _ 2 SW Exterior Concrete Block - Int Insul BR 2 4.1 11 0 8 0 88.0 ft2 0 0 0.45 0 _ 3 NW Garage Frame - Wood BR 2 13 13 0 8 0 104.0 ft2 0 0.23 0.01 0 _ 4 SW Exterior Concrete Block - Int Insul BA 2 4.1 6 0 8 0 48.0 ft2 0 0 0.45 0 _ 5 SE Exterior Concrete Block - Int Insul BR 3 4.1 13 0 8 0 104.0 ft2 0 0 0.45 0 _ 6 SW Exterior Concrete Block - Int Insul BR 3 i 4.1 12 0 8 0 96.0 ft2 0 0 0.45 0 _ 7 NE Exterior Concrete Block - Int Insul KitLivDin 4.1 18 0 9 4 168.0 ft2 0 0 0.45 0 8 SE Exterior Concrete Block - Int Insul KitLivDin 4.1 26 0 9 4 242.7 ft2 0 0 0.45 0 7/30/2021 2:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 r-t'%nRA Mery nn1) IAIDI IT 0I111A11AADV f%uc(`KI ICT D1=DnPT 1 VI\IVI 1%TW- -- ---- WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space Et In Et in Area R-Vqllle -Erat 9 NE Exterior Concrete Block - Int Insul M BA 4.1 6 0 8 0 48.0 ft2 0 0 0.45 0 _ 10 NE Exterior Concrete Block - Int Insul M BR 4.1 13 0 8 0 104.0 ft2 0 0 0.45 0 11 SW Exterior Concrete Block - Int Insul M BR 4.1 4 0 8 0 32.0 ft2 0 0 0.45 0 _ 12 'NW Exterior Concrete Block - Int Insul M BR 4.1 14 0 8 0 112.0 ft2 0 0 0.45 0 _ 13 NW Exterior Concrete Block - Int Insul Foyer 4.1 5 0 8 0 40.0 ft2 0 0 0.45 0 14 SW Garage Frame - Wood Foyer 13 4 0 8 0 32.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value. Ft In In Ft eightln Area 1 NW Insulated Foyer None .54 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC imp Area Depth Separation Int Shade Screening 1 SW 2 Metal Low-E Double Yes 0.57 0.24 N 16.9 ft2 2 ft 0 in 0 ft 6 in None None 2 SW 4 Metal Low-E Double Yes 0.57 0.24 N 7.5 ft2 2 ft 0 in 0 ft 6 in None None 3 SW 6 Metal Low-E Double Yes 0.57 0.24 N 16.8 ft2 2 ft 0 in 0 ft 6 in None None 4 NE 7 Metal Low-E Double Yes 0.57 0.24 N 16.8 ft2 2 ft 0 in 0 ft 6 in None None 5 SE 8 Metal Low-E Double Yes 0.57 0.24 N 34.0 ft2 2 ft 0 in 0 ft 6 in None None 6 SE 8 Metal Low-E Double Yes 0.69 0.22 N 39.6 ft2 2 ft 0 in 0 ft 6 in None None 7 NE 9 Metal Low-E Double Yes 0.57 0.24 N 7.5 ft2 2 ft 0 in 0 ft 6 in None None 8 NW 12 Metal Low-E Double Yes 0.67 0.24 N 34.2 W 4 ft 0 in 0 ft 6 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 391 ft2 391 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000325 1092 59.91 112.48 .111 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:8.5 28.2 kBtu/hr 1 sys#1 7/30/2021 2:26 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 r'/'10ILA MAnC )n,)n IAIDI IT CI IMMADV t'%W=f`IfI ICT 12PPnRT COOLING SYSTEM # System Type Subtype Subtype Efficiency 'Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 15 28.4 kBtu/hr 852 cfm 0.75 1 sys#1 HOT WATER SYSTEM . # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply -- -- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 262 ft2 Attic 63 ft2 Default Leakage AHU (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling r Jan Feb Heating [X] Jan Feb Mar (X] Mar [ ]Apr [ [ ] [ ] Ma ()(] Jun [�] Jul ]May [ j Jun [ ] Jul [)(] Aug�] [ ] Au[ Se ] Sep [ Oct [ ] Oct [ ]Nov [X] Nov r Dec [X] Dec Dec Venting [[[[ 1111 Jan Feb [[XX]] Mar pr [X] Apr [ ] May [ 1 Jun [ ]Jul [ 1 Aug [[[ 1 Se [X] Oct [X) Nov [[[ 111 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) PM 80 80 78 78 78 78 8 78 78 80 78 78 78 78 78 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) PM 66 68 66 66 68 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 BR 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BA 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 BR 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 KitLivD[n Default(8lbs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 AHU Default(8 Ibs/sq.ft. ft2 ft 0.3 M BA Default(8lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M BR Default(8 Ibs/s .ft. ft2 ft 0.3 Foyer 7/30/2021 2:26 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5