Loading...
HomeMy WebLinkAboutProject InformationJob: Bradescu - 7408 San Car... Manual S Compliance Report Date: Jul23, 2021 E-CaIcs Entire House By: E-Calcs Plus, Inc. Iglus, Inc. E-Calcs Plus, Inc. Serving all of Florida Phone: 833.322.5271 Email: erlc@ecalcsplus.com Web: www.ecalesplus.com License: HERS Rater ID 0757810 For: Bradescu - 7408 San Carlos Dr 7408 San Carlos Dr, Fort Pierce, FL 34951 Design Conditions Outdoor design DB: 90.0°F Sensible gain: 20292 Btuh Outdoor design WB: 78.0°F Latent gain: 4295 Btuh Indoor design DB: 75.0°F Total gain: 24587 Btuh indoor RH: 50% Estimated airflow: 947 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031 L Actual airflow: 947 cfm Sensible capacity: 22550 Btuh 111% of load Latent capacity: 5009 Btuh 11 No of load Total capacity: � 27559 Btuh 1121/oof load SHR: 82% Design Conditions Outdoor design DB: 42.0°F Heat loss: 18633 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Actual airflow: 0 Output capacity: 28200 Supplemental heat required: Backup equipment type: Manufacturer: Carrier Actual airflow: 0 Output capacity: 5.0 Model: 25HBC530A00300+FX4DNF031 L cfm Btuh 151%of load 0 Btuh Elec strip Model: AFUE 100 cfm kW 92% of load Temp. rise: 26 °F Meets all requirements of ACCA Manual S. Entering coil DB: 76.5°F Entering coil WB: 63.5°F Entering coil DB: 70.0°F Capacity balance: 32 °F Economic balance: -45 °F r 2021-Jul-30 11:40:45 -Fa- wreigl�Ysoftc Right-SuiteO Universal 2021 21.0.07 RSU28254 Page 1 )m ... Dr\Bradescu -7408 San Carlos Dr 7.30.2021.rup Calc = MJ8 Front Door faces: S Job: Bradescu -7408 San Car... Project Summary Date: Jul 23, 2021 E-Calcs Entire House By: E-Calcs plus, Inc. Plus, Inc, E-Calcs Plus, Inc. Serving all of Florida Phone: 833.322.5271 Email: edc@ecalcsplus.com Web: www.ecaicsplus.com License: HERS Rater ID 0757810 For: Bradescu - 7408 San Carlos Dr 7408 San. Carlos Dr, Fort Pierce, FL 34951 Notes: Design Information l Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 16204 Btuh Ducts 2429 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 0 Btuh 0 Btuh 18633 Btuh Fort Pierce, FL, US Simplified Average 0 z Heating 1263 Coolin 1263g Area 10744 10744 Volumee (f13) Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 81 41 Heating Equipment Summary Make Carrier Trade Model 25HBC53OA00300 AHRI ref 9154945 Efficiency 8.5 HSPF Heating input Heating output 28200 0 Btuh 47°F Temperature rise 0 cfm OF Actual air flow 0 c cfm/Btuh Air flow factor 0.50 H2O Static pressure Space thermostat Capacltybalance point32 °F Backup: Carrier AFUE 100 Input = 5 kW, Output = 17061 Btuh, 100 AFUE Summer Design Conditions Outside db Inside db 90 OF 75 OF Design TD 15 OF M Daily range Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 15633 Btuh Ducts - 4659 Btuh Central vent (0 cfm) 0 Btuh (norie) Blower 0 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Equipment sensible load 20292 Btuh Latent Cooling Equipment Load Sizing Structure 2520 Btuh Ducts 1774 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 4295 Btuh Equipment Total Load (Sen+Lat) 24587 Btuh Req. total capacity at 0.75 SHR 2.3 ton Cooling Equipment Summary Make Carrier Trade Cond 25HBC53OA00300 Coil FX4DNF031 L AHRI ref 9154945 Efficiency 12.5 EER, 15 SEER Sensible cooling 21300 Btuh Latent cooling 7100 Btuh Total cooling 28400 Btuh Actual air flow 947 cfm Air flow factor 0.047 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �•. 2021-Jul-30 11:40:45 - wr2gt2MS4 ft^ Page 1 - Right -Suite® Universal 2021 21.0.07 RSU28254 ... Dr\Bradescu - 7408 San Carlos Dr 7.30.2021.rup Calc = MJ8 Front Door faces: S Job: Bradescu - 7408 San Car... Load Short Form Date: Jul 23, 2021 E-Cams Entire House By: E-Calcs Plus, Inc. Plus, Inc. E-Calcs Plus, Inc. Serving all'of Florida Phone: 833.322.5271 Email: eric@ecalcsplus.com Web: www.ecaicsplus.com License: HERS Rater ID 0757810 For: Bradescu - 7408 San Carlos Dr 7408 San Carlos Dr, Fort Pierce, FL 34951 Htg Clg Infiltration Outside db (OF) 42 90 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (OF) 28 15 Fireplaces Daily range - M Inside humidity (%) 50 50 Moisture difference (gr/lb) 23 61 HEATING EQUIPMENT Make Carrier Trade Model 25HBC53OA00300 AHRI ref 9154945 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacitybalance point= 32 OF Backup: Carrier AFUE 100 8.5 HSPF 28200 Btu h-@ 47° F 0 OF 0 cfm 0 cfm/Btuh 0.50 in H2O COOLING EQUIPMENT Make Carrier Trade Cond 25HBC53OA00300 Coil FX4DNF031 L AHRI ref 9154945 Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 12.5 EER, 15 SEER 21300 Btuh 7100 Btuh 28400 Btuh 947 cfm 0.047 cfm/Btuh 0.50 in H2O 0.83 Input = 5 kW Out Lit = 1 /ubi tslun ROOM NAME tuu rirurz Area (tt) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Laundry 42 812 1008 0 0 47 103 BR 2 143 224.0 2215 0 23 BA 2 54 156 734 2790 500 2481 0 116 BR 3 KitLivDin 492 6556 9213 0 430 WIC 2 20 0 0 0 0 0 0 0 AHU 15 54 0 742 503 0 23 M BA 30 0 0 0 0 M WIC 182 3636 3823 0 178 M BR 1C ,t 4 7G FFn 0 26 toyer Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-30 11:40:45 wraglhttsoft' Page 1 �. ,.,. .. Right-Suite®Universal 2021 21.0.07 RSU28254 C ... DABradescu - 74 88 San Carlos Dr 7.30.2021.rup Calc = MJ8 Front Door faces: S Entire House d 1263 18633 20292 0 947 Other equip loads 0 0 Equip. @ 1.00 RSM 20292 Latent cooling 4295 I A nnn 1 .r oco" I 9d5R7 1 0 1 947 TOTALS 1400 1 UVOI' Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jul-30 11:40:45 R wri?htsof Right -Suite® Universal 2021 21.0.07 RSU28254 Page 2 Dr\Bradescu - 7408 San Carlos Dr 7.30.2021.rup Calc = MJ8 Front Door faces: S Building Analysis E-Gaits Entire House Plus, Inc. E-Caros Plus, Inc. Serving all of Florida Phone: 833.322.5271 Email: eric@ecalcsplus.com Web: www.ecalesplus.com License: HERS Rater ID 0757810 For: Bradescu - 7408 San Carlos Dr 7408 San Carlos Dr, Fort Pierce, FL 34951 Location: Fort Pierce, FL, US Elevation: 25 ft Latitude: 270N . Outdoor: Heating Dry bul b (OF,) 42 Dallyrange (OF) - Wet bulb (°F) - Wind speed (mph) 15.0 Indoor: Indoor temperature (OF) Design TD (OF) Relative humidity (%) Coolie g Moisture difference (gr/lb) ` 90 Infiltration: 20 ( M) Method 78 Construction quality 7.5 Fireplaces Component Btuh/fF Btuh % of load Walls 3.8 3972 21.3 Glazing 16.7 2893 15.5 Doors , 15.1 706 3.8 Ceilings 0.9 1132 6.1 Floors 4.0 5022 27.0 Infiltration 2.3 2480 13.3 Ducts 2429 13.0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments Total 0 18633 100.0 Component Btuh/ftz Btuh % of load Walls 2.0 2113 10.4 Glazing 22.3 3852 19.0 Doors 8.5 398 2.0 Ceilings 1.6 2021 10.0 Floors Infiltration 0 0.6 0 679 0 3.3 Ducts 4659 23.0 Ventilation Internal gains 0 6570 0 32.4 Blower 0 0 Adjustments 0 202921 100.0 Total Latent Cooling Load = 4295 Btuh overall U-value = 0.129 Btuh/ft2- °F Data entries checked. GBJM t2§ilings Other Ceilings IrlFiltratiori Job: Bradescu - 7408 San Car... Date: Jul 23, 2021 By: E-Calcs plus, Inc. Heating Cooling 70 75 28 15 50 50 23.2 61.5 Simplified Average 0 cts G irs 2021-Jul-30 11:40:45 -�# bVfi'i�4ltit�,OfS" Rig ht-Suite®Universal 2021 21 .0.07 RSU28254 Page 1 ... Dr\Bradescu - 7408 San Carlos Dr 7.30.2021.rup Calc = MJ8 Front Door faces: S Job M Bradescu - 7408 San Carlos Dr Performed by E-Calcs Plus, Inc. for: Bradescu - 7408 San Carlos Or 7408 San Carlos Or Fort Pierce, FL 34951 E-Cares Plus, Inc. Serving all of Florida Phone: 833.322.5271 www.ecaicsplus.com eric@ecalcsplus.com chi Scale: 1 : 72 Page 1 Right-Suite(E) Universal 2021 21.0.07 RSU28254 2021-Jul-30 11:41:13 7408 San Carlos Dr 7.30.2021.rup Duct Stem Summary Job: Bradescu-7408San Car... E-Caros y • y Date: Jul 23, 2021 Plus, Inc. Entire House By: E-Calcs Plus, Inc. E-Caics Plus, Inc. Serving all of Florida Phone: 833.322.5271 Email: eric@ecalcsplus.com Web: www.ecalesplus.com License: HERS Rater ID 0757810 For: Bradescu - 7408 San Carlos Dr 7408 San Carlos Dr, Fort Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Name BA 2 BR 2 BR 3 Foyer KltLivDin KitLivDin-A Laundry M BA M BR , Heating 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.241 / 0.099 in H2O 0.160 in/100ft 0 cfm 213 ft Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.241 / 0.099 in H2O 0.160 in/100ft 947 cfm Design (Btuh) Htg (cfm) - Clg (cfm) Design FIR(in) Diam H x W (in) Duct Matl Actual . Ln (ft) Ftg.Egv Ln (ft) Trunk 500 0 23 0.167 4.0 Ox 0 VIFx 19.5 125.0 st1 c c 2215 0 103 0.172 7.0 Ox 0 VIFx 15.2 125.0 st2 c 2481 0 116 0.164 7.0 Ox 0 VIFx 21.9 125.0 SO 550 0 26 0.179 4.0 Ox 0 VIFx 9.6 125.0 st2 c c 4606 0 215 0.160 9.0 Ox 0 VIFx 26.2 125.0 st1 c 4606 0 215 0.177 8.0 Ox 0 VIFx 11.6 125.0 st1 c 1008 0 47 0.191 5.0 Ox 0 VIFx 6.5 120.0 st2 503 0 23 0.169 4.0 Ox 0 VIFx 17.9 125.0 st2 c c 3823 0 178 0.170 8.0 Ox 0 VIFx 16.7 125.0 st2 Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk Name Trunk Type 0 0 569 378 0.160 0.169 725 693 12.0 1 10.0 0 x 0 0 x 0 VinlFlx VinlFlx st1 st2 Peak AVF Peak AVF Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk Name Grille Size (in) 0 947 62.0 0.160 696 12.9 14x 14 RtFg rb1 Ox 0 2021-Jul-30 11:40:45 wri9h,:230ftl Right -Suite® Universal 2021 21.0.07 RSU28254 Page 1 Gl ... DABradescu - 7408 San Carlos Dr 7.30.2021.rup Calc = MJ8 Front Door faces: S Static Pressure and Friction Rate Job: Bradescu -7408 San Car... E-Ca1Cs Date: Jul 23, 2021 Plus, Inc. Entire House By: E-Calcs Plus, Inc. E-Calcs Plus, Inc. Serving all of Florida Phone: 833.322.5271 Email: edc@ecalcsplus.com Web: www.ecalesplus.com License: HERS Rater ID 0757810 For: Bradescu - 7408 San Carlos Dr 7408 San Carlos Dr, Fort Pierce, FL.34951 Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses 0 Coil 0 0 0 Heat exchanger 0.03 0.02 Supply diffusers 0.03 0.02 Return grilles 0.10 0.1 C Filter 0 0 Humidifier 0 Balancing damper 0 0 Other device 0 Available static pressure 0.34 0•34 Total• Supply Return (ft) (ft) Measured length of run -out 18 2 Measured length of trunk 8 0 Equivalent length of fittings 125 60 Total length 151 62 Total effective length 213 . FrictionRate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.160 OK 0.160 OK Return Ducts 0.160 OK 0.160 OK FittingEquivalent• D' Supply 11A=20, 4AD=60, 11G=5, 1A=35, 11G=5: TotalEL=125 Return 6M=20, 5D=40: TotalEL=60 2021-Jul-3011:40:45 *wri htsoft- ,.,,.,.�,-9....,.q Right -Suite® Universal2021 21.0.07 RSU28254 Page 1 ,Ztk ... Dr\Bradescu - 7408 San Carlos Dr 7.30.2021.rup Calc = MJ8 Front Door faces: S