Loading...
HomeMy WebLinkAboutREVISION Multiple DocsOFFICE USE ONLY: DATE FILED: ' ' REVISIONFEE: PERMIT # 2- D ✓ T RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 RECEIVED (772) 462-1553 JAN'2 0 2022 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION Permitting Department St. Lucie County LOCATION/SITE _ • rrrrann_ DETAILED DESCRIPTION OF PROJECT CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CBC051145 BUSINESS NAME: GRBK GHO Homes LLC QUALIFIERS NAME: William Handler ADDRESS: 590 NW Mercantile Place CITY: Pt St Lucie STATE: FL PHONE (DAYTIME). 772-773-0075 OWNER/BUILDER INFORMATION: NAME: GRBK GHO St Lucie LLC ADDRESS:590 NW Mercantile Place CITY: Port St Lucie PHONE (DAYTIME: 772-773-0075 ST. LUCIE CO CERT. #: ZIP: 34986 FAX: 561-688-0909 STATE: FL ZIP: 34986 FAX: 561-688-0909 ARCHITECT/ENGINEER INFORMATION: NAME: Donald J Nuelle ADDRESS: 11634 SW Rowena St CITY: Port St Lucie PHONE (DAYTIME): 561-629-6975 SLCCC: 9123109 Revised 06130117 STATE: FL ZIP: 34987 FAX: N/A REk/11SION iu RECEIVED JAN TO 1011 FORM R405-2020 Permitting Department FLORIDA ENERGY EFFICIERGYGME FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MW-62 Builder Name: GHO BUILDERS Street: 2650 CONIFER DR Permit Office: ST. LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1832.4 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 1632.60 ft2 b. Frame - Wood, Adjacent R=11.0 199.89 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 11. Ceiling Types (1924.2 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=40.0 1832.00 ft2 6. Conditioned floor area above grade (ft2) 1832 b. Knee Wall (Vented) R=38.0 92.23 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(260.3 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Main R ft2 6 494 a. U-Factor: Dbl, U=0.69 260.34 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.6 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 6.163 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.260 a. Electric Strip Heat 24.8 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1832.0 sqft.) Insulation Area EF: 0.940 - a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.142 Total Proposed Modified Loads: 54.75 PASS Total Baseline Loads: 57.59 I hereby certify that the plans and specifications covered by Review of the plans and Og t%E S7,q?�, this calculation are in compliance with the Florida Energy specifications covered by this Code. >�. calculation indicates compliance y4} �,,'' = = `��.�� with the Florida Energy Code. rrrrrr'�; :;�: ;;:•'�;� O PREPARED BY: - ____- Before construction is completed C DATE: 01/05/2022 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Energy Co Florida Statutes.; COD 1� with the Florida e. we OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no;greater than 7.00 ACH50 (R402.4.1.2). IC6- C��7 RECEIVED PXN ,�16 / f" /zv JAN 2 0 2022 1/5/2022 1:47 PM EnergyGauge® USA 7.0.00 - J.2 f 1 Rn �2020) Co T' a Unty, i nnitting age 1 of 4 GnRnn PAn9;_'?n9n IMPI IT CI IMMARY [.HFCKI IRT REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-62 User 1 GHO BUILDERS ST. LUCIE COUNTY Detached New (From Plans) Bedrooms: 2 Conditioned Area: 1832 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 2650 CONIFER DR County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 1832 17953.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1832 17953.6 Yes 3 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet- 1 Slab -On -Grade Edge Insulatio Main 188.1 ft 1832 ft2 ____ 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 2048 ft2 0 ft2 Medium N 0.4 N 0.9 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1832 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 40 Blown Main 38 Blown 1832 ft2 0.1 Wood 92.23 ft2 0.11 Wood 1/5/2022 1:47 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 GnRhn PAnr,-,?ngn INPI IT Al IMMARY CHFCKI IRT RFP0RT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w V Ornt TO Wall T�ipe Space _ 1 N Exterior Concrete Block - Ext Insul Main 4.1 19 2 9 4 178.9 ft2 0 0 0.3 0 _ 2 E Exterior Concrete Block - Ext Insul Main 4.1 58 4 9 4 544.4 ft2 0 0 0.3 0 _ 3 S Exterior Concrete Block - Ext Insul Main 4.1 43 7 9 4 406.8 ft2 0 0 0.3 0 _ 4 W Exterior Concrete Block - Ext Insul Main 4.1 53 10 9 4 502.4 ft2 0 0 0.3 0 5 - Garage Frame - Wood Main 11 21 5 9 4 199.9 ft2 0 0.25 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Main None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Double (Clear) Yes 0.69 0.26 N 26.0 ft' 7 ft 0 in 1 ft 0 in None None 2 e 2 Metal Double (Clear) Yes 0.69 0.26 N 16.7 ft2 1 ft 0 in 1 ft 0 in None None 3 e 2 Metal Double (Clear) Yes 0.69 0.26 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 4 s 3 Metal Double (Clear) Yes 0.69 0.26 N 30.0 ft2 1 ft 0 in 1 ft 0 in None None 5 s 3 Metal Double (Clear) Yes 0.69 0.26 N 36.0 ft2 10 ft 0 in 1 ft 0 in None None 6 s 3 Metal Double (Clear) Yes 0.69 0.26 N 96.0 ft2 10 ft 0 in 1 ft 0 in None None 7 w 4 Metal Double (Clear) Yes 0.69 0.26 N 12.0 ft2 1 ft 0 in 1 ft 0 in None None 8 w 4 Metal Double (Clear) Yes 0.69 0.26 N 7.0 ft2 1 ft 0 in 1 ft 0 in None None 9 W 4 Metal Double (Clear) Yes 0.69 0.26 N 21.7 ft2 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 583 ft2 583 ft2 64 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000436 2094.6 114.92 215.74 .137 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 24.82 kBtu/hr 1 sys#1 1/5/2022 1:47 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FnRM R4n5-2020 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 34.6 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS -- Supply --- -- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 494 ftZ Attic 232 ftZ Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb HeatinJan f X Feb Mar Mar Apr E APr I Ma X Jun X Jul May r j Jun Jul X Aug f AuSep Se Oct Oct Nov Nov Hx Dec Dec H Ventin Jan [ Feb X Mar [X] A r May Jun [ Jul [ Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/sq.ft. 0 ft' 0 ft 0.3 Main 1/5/2022 1:47 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a Project Name: MW-62 Builder Name: GHO BUILDERS Street: 2650 CONIFER DR Permit Office: ST. LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 - Permit Number: U Owner: Jurisdiction: W Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind o4o'no and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between e s and walls or cemlmnas. a. In addition, inspection of log walls shall be in accordance with the provisions of IGG-4U0. 1/5/2022 1:47 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 2650 CONIFER DR, FORT PIERCE, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Ext Insul, Exterior R=4.1 1632.60 ft2 b. Frame - Wood, Adjacent R=11.0 199.89 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=40.0 1832.00 ft2 6. Conditioned floor area (ft2) 1832 b. Knee Wall (Vented) R=38.0 92.23 ft2 c. N/A R= ft2 7. Windows- Description Area 12. Ducts, location &insulation level R ft2 a. U-Factor: Dbl, U=0.69 260.34 ft2 a. Sup: Attic, Ret: Attic, AH: Main 6 494 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.6 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 24.8 COP:1.00 Area Weighted Average Overhang Depth: 6.163 ft. Area Weighted Average SHGC: 0.260 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.94 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft2 Credits (Performance method) None b. N/A R= ft2 c. N/A R= ft2 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above ener y saving features which will be installed (or exceeded) in this home before final inspection. therwise, a new EPL Display Card will be completed based on installed Code compliant fe tures. Builder Signature: Date: t %1%Qz Address of New Home:FS,'Or, City/FL Zip:er�-� �-tas *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 /5/2022 1:47 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2020 Florida Building Code, Energy Conservation, 7th Edition Jurisdiction: Permit #: Job Information Builder: GHO BUILDERS Community: Lot: NA Address: 2650 CONIFER DR City: FORT PIERCE State: FL Zip: 34951 Air Leakage Test Results -Passing results must meet either the Performance, Prescriptive, or ERl Method ,0 PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and; verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones 1 and 2. 0 PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding .'the selected ACH(50) value, as shown on Form R405-2020 (Performance) or R406-2020 (ERI), section labeled as infiltration, sub -section ACH50. ACH(50) specified on Form R405-2020-Energy Calc (Performance) or R406-2020 (ERl): 7.000 x 60 = 17954 = Method for calculating building volume: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans F-1 PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation 0 Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2020 7th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 1/5/2022 1:48:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 Load Job: -�,- wrightsoft Ld Short FDate: Aug 3, 2021 Entire Mouse By. Projectu s Far: MV1r-62 2650 CONIFER DR, FORT PIERCE, FL34951 Design Informati• Htg Glg Infiltration Outside db (°F) 43 91 Method Simplified Inside db ff) 70 72 Construction quality Average Design TD (°F) 27 19 Firep[aces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (grtlb) 0 65 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036 230C'* AHRI ref Coil CBA27UHE a36-230*++TDR AHRI ref 204289057 Efficiency 100 EFF Efficiency 13.0 EER,16 SEER Healing input 7.3 kW Sensible cooting 24220 Btuh Healing output 24817 Btuh Latent coolirtg 10380 Btuh Temperature rise 20 °F Total coating 34600 Btuh Actual airflow 1153 corn Actual airflow 1153 cfm Air flow factor 0.046 dm.Btuh Airflow factor 0.046 cfmBtuh Static pressure 0 in H2O Static pressure 0 'in H2O Space thermostat Load sensible heat ratio 0.72 ROOM NAME Area OF) Htg toad (Btuh) Cog load (Bath) HtgAVF (drn) CIgAVF (dm) MASTER SUITE 312 5009 3794 230 176 HERWIC 60 927 520 43 24 MASTER BATH 169 T-780 2198 82 102 BED 2 205 2905 3264. 133 152 UTILITY 73 866 894 40 42 BATH 2 51 41 333 2 15 FOYER 69 734 530 34 25 DINING 133 3650 3152 168 146. KITCHEN 156 1,724 2387 79 111 DEN 181 3823, 3218 175 149 GREAT RM 376 3629 4156 167 193 IJAI I thfi C(`LA .AO 104 QQG 7 40 Calculations approved byACCAtG meetall requirements of Manual J.8th Ed. -� wrI hts4jft= 2021-AL0313:18:38 ^- 9. Rigit Stiz9 h vema1202121DASASU249b4 Page 1 �+�.ers%ryuserooamereslwdgfzoftHVACV.,,f62tu� C2Pc=li4G9 FraczOD�6aoe9:'P8 Entire House 1833 2512E .24831 1153 1153 Other equip loads 0 0 Equip. @ 0.95 RSM 23714 Latent cooling 9689 T/1TAI C qAn! 1,1 _FR 11 A:3 Calculations approved byACCAta meet all requirements of Manual J 8th Ed. ti wri htsoft® 2021•At9-0313:18:38' .. 9 .�-.,. RigttSute^tkiv--i- 120212"DSRStMgE4 Paget ACCA _ers0.rtyUser0oamarts\Wri9luaftWACV:W-62stp Catc=NUS Frort Dbzrb=E N - - wrightsoft- Project Summary Entire House Project Information For MW-62 2650 CONIFER DR, FORT PIERCE; FL34951 Motes: Design Information Weather: Mere Beach Municipal AP FL, US Job: Date: Aug.3, 2021 By. Winterbesign Conditions Summer'Design Conditions Outside db 43 'F Outside db 91 OF Inside db 70 °F Insidedb 72 OF Design TD 27 OF Design TD. 19 OF Daily,range L Relative humidity 50 % Moisture ditfererice 65 grAb Heating Summary Sensible Cooling, Equipment Load Sizing Structure 21926 Btuh Structure 214,05 Stuh Ducts 3199 Btuh Ducts 3427 Btuh Central vent (0 cfm) 0 Btuh Centralvent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25126 Btuh Use manufactureft data n Ratelsm—ngi multipplier Equipment load, 0.95 237.14 Btuh Infiltration sensibIle Method Simpliined Latent Cooling-Equiprnent Load Sizing Construction quality Average Fireplaces a Structure '8161 Btuh Ducts 1527 Btuh Genoa] vent (0efm) 0 Btuh f; Qeatirtc� coolfcn� g;; (none) Btuh Area (ft2) 1833 1833 Equipment latent load 9689 Volume (ft) 18050 18Q60 Air changeslhour 0.38 0.201 Equipment Total Load (Sen+Lat) 33403 Btuh Equiv AVF (cfm) 114 60 Req. total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment' Summary Make Make Lennox Trade Trade LENNOX Model Cond ML14XC1S036-230C" AHRI ref Gait CBA27UHE-036-230'++TDR AHR[ ref 204289057 Efficiency 100 EFF Efficiency 13:0 EER,.16 SEER Heating input 7.3 kW Sensible coating 24220. Btuh Heating output 24817 Btuh Latentcoollrtg 10380 Btuh Temperature rise 20 OP Tout cooling 34600 Btuh Actual airflow 1153 cfm Actual airflow 1153 cfm Airflowfactor 0.046 cfm]Btuh Airflowfadbir 0.046 cfrhBtuh Static pressure 0 .in H2O Stadcpressure 0 in-1-120 Space thermostat Load sensible heat ratio 0.72 Calculations approved byACCA to meet all requirements of` -Manua( J Sth-Ed. -��- wr➢ghtsoft® 2021-Aug•0313:18:38 .-- •�^ Rigtl•Stitct&LWversal2a212t.ODSRSt/2SM Pagel ACCI', _.ers%ArtWserl Xamri!lWrigtrofthVAClVW-62np Catc=WS Erozbbbnrt ms: N GH O HOMES MW-62 2650 CONIFER DR FORT PIERCE, FL 34951