HomeMy WebLinkAboutConstruction DetailGeneral Notes A. CONCRETE & FOUNDATION DESIGN: 1. ALL CONCRETE GRADE BEAMS AND FOOTINGS SHALL BE 3000 PSI MINIMUM. 2. ALL CONCRETE FILLED SUPPORTED SLABS SHALL BE 2500 PSI MINIMUM, 3 1/2" NOMINAL THICKNESS. 3. FIBERMESH (3/4" PER CUBIC YARD MIN.) MEETING APPROPRIATE ACI AND ASTM REQUIREMENTS MAY BE USED IN LIEU OF WELDED WIRE MESH 4. ALL SLABS ON GRADE SHALL BE 4" THICK WITH FIBERMESH. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615, BE GRADE 60 (60 KSI MIN.) DEFORMED BARS, #3 BARS MAY BE GRADE 40 6. ALL OVER POUR CONCRETE FILLED SUPPORTED SLABS SHALL BE 3000 PSI MIN., 2" MINIMUM. THICKNESS. 7. SOIL BEARING PRESSURE SHALL BE A MINIMUM OF 1500 PSF. S. THE CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING: OPC (PORTLAND CEMENT TYPE 1,- ASTM C 150). AGGREGATES - #6 STONE, ASTM C 33 SIZE NO.67 LESS THAN 3/4". AIR ENTRAINING +/- 1 % - ASTM C 260. WATER REDUCING AGENT - ASTM C 494. CLEAN POTABLE WATER. OTHER ADMIXTURES SHALL NOT BE PERMITTED. 9. METAL WELDED WIRE SHALL CONFORM TO ASTM A 185. 10. PREPARE & PLACE CONCRETE ACCORDING TO AMERICAN CONCRETE INSTITUTE MANUAL STANDARD PRACTICE, PART 1, 2, & 3 ALONG WITH HOT WEATHER CONDITIONS RECOMMENDATIONS. 11. IF UTILIZING EXISTING CONCRETE FOR FOUNDATION, CONCRETE SHALL BE A MINIMUM OF 4" IN THICKNESS, VISIBLY FREE OF ANY STRUCTURAL EXCESSIVE CRACKING, SPALLING OR OTHER DETERIORATION. B. MASONRY: I. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2.ALL MORTAR SHALL BE OF TYPE M OR S. 3.ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4.PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5'-0" IN HEIGHT. C. ALUMINUM: I. ALL STRUCTURAL ALUMINUM SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF 6005-T5 FOR ALLOY WITH A MINIMUM THICKNESS OF 0.040" FOR SUPPORTING MEMBERS. 2. WHERE KICK PLATES ARE USED A MINIMUM THICKNESS OF 0.024" SHALL APPLY. 3. STRUCTURAL ALUMINUM DESIGN CONFORMS TO "PART 1-A - SPECIFICATIONS FOR ALUMINUM STRUCTURES - ALLOWABLE STRESS DESIGN' OR "PART 1-B - SPECIFICATIONS FOR ALUMINUM STRUCTURES - BUILDING LOAD AND RESISTANCE FACTOR DESIGN" OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC.WASHINGTON D.C. THE FLORIDA BUILDING CODE 7TH EDITION ( CHAPTER 16 STRUCTURAL DESIGN & CHAPTER 20 ALUMINUM). 4. WHERE ALUMINUM COMES INTO CONTACT WITH STEEL, OR PRESSURE TREATED LUMBER PROVIDE DIELECTRIC SEPARATION. 5. ALUMINUM MEMBERS SHALL BE STITCHED WITH NO LESS THAN #10 SMS 6" FROM THE ENDS AND 12" ON CENTER, IF USING 912 SPACING MAY BE 24" ON CENTER. 6. VINYL AND ACRYLIC PANELS SHALL BE REMOVABLE. THEY SHALL BE IDENTIFIED WITH A DECAL ESSENTIALLY STATING "REMOVABLE PANEL SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 NTH". DECAL SHALL BE PLACED SO IT IS VISIBLE WHEN PANEL IS INSTALLED. 7. 1 "X2"X0.045" NON-STRUCTURAL MEMBERS SHALL BE ATTACHED TO HOST WITH 1/4"0 X 1-3/4" EMBEDMENT & 24" O.C. MASONRY SCREW FOR CONCRETE & EQUIVALENT SIZE WOOD SCREW WHEN IN WOOD & #IOX 1/2" EMBEDMENT SMS OR TEK SCREWS IN ALUMINUM MEMBERS TYPICAL. 2. HEX BOLTS HAS TO BE ASTM A 325, PLATED WITH STANDARD FLAT WASHERS AND NUTS. 3. ALL CONCRETE SCREWS SHALL BE, SIMPSON, HILTI, RAWL, TAPCON, REDHEAD, DYNABOLT, PORTECT OR APPROVED EQUAL. 4. ALL METAL TIES AND ASSOCIATED ACCESSORIES SHALL BE HOT DIPPED GALVANIZED. 5. ALL LAG BOLTS SHALL HAVE A MINIMUM EMBEDMENT OF 8X BOLT DIAMETER INTO STRUCTURAL FRAMING (G=.42 MIN.). 6. LAG BOLTS AND SCREWS INTO WOOD FRAMING SHALL BE PROVIDED WITH PILOT HOLES HAVING A DIAMETER NOT GREATER THAN 70 PERCENT OF THE THREAD DIAMETER OF THE BOLT OR SCREW. ALL LAG BOLTS AND SCREWS SHALL BE INSERTED IN PILOT HOLES BY TURNING AND UNDER NO CIRCUMSTANCES BY DRIVING WITH A HAMMER 7. ALL EXPANSION ANCHORS SHALL BE DESIGNED IN ACCORDANCE WITH THE SPECIFIC MANUFACTURER'S REQUIREMENTS AND ALLOWABLE LOADS AND SHALL ONLY BE APPLIED IN CONDITIONS ACCEPTABLE TO MANUFACTURER. FASTENERS SHALL BE A MINIMUM OF SAE GRADE #5 OR BETTER ZINC PLATED. 8. ALL FASTENERS CONNECTING ALUMINUM COMPONENTS OR PRESSURE TREATED LUMBER ARE STAINLESS STEEL TYPE NO 18-8, UNLESS MANUFACTURER GALVANIZED BOLTS SPECIFIES FOR USE WITH ACQ PRESSURE TREATED WOOD, OR OTHERWISE NOTED ON PLANS. 9. ALL FASTENERS SHALL COMPLY WITH ASTM Al53. 10. ALL CONNECTORS SHALL COMPLY WITH ASTM A653 CLASS G-185. 1I. FOR SMS, THE MINIMUM CENTER -TO -CENTER SPACING SHALL BE 3/4" AND MINIMUM CENTER -TO -EDGE SHALL BE 1/2" UNLESS NOTED OTHER WISE. E. REFERENCE STANDARDS: ASTM E 119 ASTM E 1300 CURRENT ASCE 7 CURRENT ALUMINUM DESIGN MANUAL -AA ASM35, AND SPEC. FOR ALUMINUM PART 1-A, & 1-B ASTM C94 ASTM C150 ASTM C33 ASTM C260 ASTM C494 ASTM A615 ASTM A185 FLORIDA BUILDING CODE 7THEDITION (CHAPTERS 16, 20 & 23). THE FOLLOWING LIST OF ABBREVIATIONS IS NOT INTENDED TO REPRESENT ALL THOSE USED ON THESE DRAWINGS, BUT TO SUPPLEMENT THE MORE COMMON ABBREVIATIONS. 1. TYP - TYPICAL 2. SIM - SIMILAR 3. UON -- UNLESS OTHERWISE NOTED 4. CONT -- CONTINUOUS 5. VIF - VERIFY IN FIELD G. RESPONSIBILITY: I. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDINANCES, ETC. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND DETAILS, NOTIFYING ENGINEER OF ANY DISCREPANCIES BETWEEN DRAWINGS, FABRICATED ITEMS, OR ACTUAL FIELD CONDITIONS. 3. THESE -DRAWINGS REPRESENT THE ACCEPTABILITY OF THE 'SUNROOM' ROOM ADDITION ELEMENTS AS PROVIDED BY THE CONTRACTOR. 4. ALL DETAILS ON THESE DRAWINGS ARE ENGINEERED BASED ON INFORMATION PROVIDED BY THE CONTRACTOR AND MANUFACTURER. 5. ANY DETAILS NOT SHOWN ARE TO BE ENGINEERED BY A LICENSED P.E. IN ACCORDANCE WITH STANDARD ENGINEERING PRACTICES. D. FASTENERS: H. MISCELLANEOUS: 1. ALL LAG BOLTS SHALL CONFORM TO STAINLESS STEEL TYPE 1• ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A 300 18-8, WITH STANDARD FLAT WASHER UNLESS MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF MANUFACTURER GALVANIZES BOLTS SPECIFIES FOR USE THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WITH ACQ PRESSURE TREATED WOOD. WALL SUPPORT SYSTEM MUST BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 2. IF ENCLOSURE CONTAINS A SWIMMING POOL OR SPA, THE ENCLOSURE SHALL COMPLY WITH RESIDENTIAL SWIMMING BARRIER REQUIREMENTS OF THE FBC 7THEDITION R 4501.17 IN ITS ENTIRETY. 3. DOOR LOCATIONS MAY BE DETERMINED IN THE FIELD BY CONTRACTOR. 4. IF PAVERS ARE UNDER ALUMINUM MEMBERS THEY SHALL HAVE EPDXY ADHESIVE TO CONCRETE OR IF USING GROUT, ENSURE BONDING AGENT IS USED FIRST AND ADHERED WITH MINIMUM 3000 PSI GROUT. i. SCREENING MATERIAL SHALL BE 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH ONLY UNLESS NOTED ON DRAWING S-2. DESIGN DATA: I. ULTIMATE DESIGN WIND SPEED Vult, (3 SECOND GUST): NOMINAL DESIGN WIND SPEED Vasd: 2. RISK CATEGORY: 3. WIND EXPOSURE: 4. WIND LOADS: 'SCREEN ROOF: N/A SCREEN WALLS: 31 PSF SOLID ROOF (SCREEN WALL): 25 PSF O P .,`�O F ........ RECEIVED . V • 00 ftft `s O �010g67 • a" • * • NOV 05 2021 TE SZA F O • St. Lucie County 00 II .p �.••F(-0 \ •: �� `o�' 0,�� Permitting ��' 'O®B soy ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E. 150MPH 116 MPH FLORIDA LICENSE: 38654 B Myron Max Neal P.E. FLORIDA LICENSE: 86663 5. FACTOR APPLIED TO SCREEN WIND LOADS FOR 18X14X0.013 OR EQUIVALENT DENSITY SCREEN MESH: 0.88 6. FACTOR APPLIED TO SCREEN WIND LOADS FOR ALLOWABLE STRESS DESIGN: 0.6 7. LIVE LOAD: 3001b. VERTICAL DOWNLOAD ON PRIMARY SCREEN ENCLOSURE MEMBERS. 200 Ib. VERTICAL DOWNLOAD ON SCREEN ENCLOSURE PURLINS. 10 PSF VERTICAL DOWNLOAD ON SOLID ROOF. 8. PROPOSED 12"XI2" W/ (1) # 5 OR (2) # 4 REBAR W/ 25" OVERLAP ON 3" CHAIRS W/ 4" MONOLIT11IC SLAB W/ FIBER -MESH FILLED W/ 3000 PSI SHALL BE ADEQUATE TO RESIST THE UPLOADS FOR THE PROPOSED STRUCTURE. 9. SCREEN ROOF TYPE: N/A 10. SOLID ROOF TYPE: 4"X48"X0.032" ELITE EPS COMPOSITE PANEL ROOF 11b FOAM DENSITY, FLORIDA PRODUCT APPROVAL, FL 7561-R5. ALUMINUM STRUCTURAL MEMBERS INDEX: S-1 GENERAL NOTES HOLLOW SECTIONS S-2 DRAWING 2 x 2:---------------------------------------2" x 2" x 0.044" S-3 DETAILS 2 x 3:---------------------------------------2" x 3" x 0.050" 2 x 4:---------------------------------------2" x 4" x 0.050„ 2 x 5:---------------------------------------2" x 5" x 0.050„ 3 x 3:---------------------------------------3" x 3" x 0.125„ OPEN BACK SECTIONS 1 x 2: ---------------------------------------- 1" x 2" x 0.040„ 1 x 3:----------------------------------------1" x 3" x 0.045„ SNAP SECTIONS 2 x 2 SMS: ---------------------------------- 2" x 2" x 0.045" 2 x 3 SMS:---------------------------------2" x 3" x 0.072" 2 x 4 SMS:--------------------------------- 2" x 4" x 0.045" 3 x 3 SMS:--------------------------------- 3" x 3" x 0.090" SELF MATING (SMB 2 x 4 SMB:---------------------- 2" x 4" x 0.044" x 0.100" 2 x 5 SMB:---------------------- 2" x 5" x 0.050" x 0.118" 2 x 6 SMB:---------------------- 2" x 6" x 0.050" x 0.120" 2 x 7 SMB:---------------------- 2" x 7" x 0.057" x 0.120" 2 x 8 SMB:---------------------- 2" x 8" x 0.072" x 0.224" 2 x 9 SMB:---------------------- 2" x 9" x 0.072" x 0.224" 2 x 10 SMB:-------------------- 2" x 10" x 0.092" x 0.374" 2x2: TUBE SECTIONS x2"x0.090" Sol•v VO 60 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fb cplans. corn C.O.A. #29054 DATE: 10/04/2021 DRAWN BY: ST I REVISION: I DATE: I RO 1 RO 2 RO 3 RO 4 Job# 21_1004_020 PROJECT ADDRESS: BENT PINE DR PIERCE, FL 34951 ACTOR: ENTERPRISES NOTES S-1 (D I U73 NOTE. PROPOSED FREESTAND STRUCTURE 8'-1" 'I`-- (+vn) LO N N N_ N_ N N_ N_ r X X X X X X X X x x x x x I I I I I I I I I I 1 I 1 I I I I I I 1 I I I I I (D (0 V I I I I ¢'x41 'X% • "I, LB FAM I I I COMPOSITE P ANEL R00 I I I I I I MIN. SLO }' PER VI I I I I I I SS3 I I I I I S-3 I I I I I I I I — I -- L--�--- —_ --1----Zx6SN8T= BRfIH—_ -- �i 56'-6" I I I I I I I 1 171 I I I I I II x L0 in LO LO L0 LO N LO N Er) N st x x vt x x k1-yN) ♦ y DOOR LOCATION MAY BE DETERMINED `� �,•,.•�GENSF •'1 1 15e IN THE FIELD BY THE CONTRACTOR. = O �► : G ... • N° IcIr i o . a � y • � s.r — 7� • i •: giA W . Zcj PROPOSED 12"X12" FOOTING W/ (1) #5 OR (2) #4 REBAR W/ 4" MONOLITHIC SLAB PROFESSIONAVENGINEER SEAL ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson P.E FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 Joel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E., FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph#(813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fb cplans. corn C.O.A.-429054 DATE: 10/04/2021 DRAWN BY: ST REVISION: DATE: RO 1 RO 2 RO 3 RO 4 Job# 211 1004-020 PROJECT ADDRESS: BENT PINE DR PIERCE, FL 34951 -ONTRACTOR: ARROYO ENTERPRISES FLOOR PLAN } 1• (4) - 3/8" 0 CONCRETE SCREW WITH 2-3/4" EMBEDMENT (MIN EDGE DISTANCE FROM DECK EDGE=3" — — MIN SPACING 4") (H) -3/8" 0 MACHINE BOLTS WITH WASHERS — — OR (3/4" SMS\ TOP VIEW IN. EDGE DISTANCE DISTANCE =1" MIN. SPACING= 2") n NOTE:MINIMUM EMBEDMENT OF ANCHORS INTO CONCRETE FOOTING SHALL BE 2-3/4" AT ALL POST LOCATIONS. ALL SCREW LENGTHS AT POST CONNECTIONS SHALL BE OF SUFFICIENT LENGTH FOR REQUIRED EMBEDMENT INTO CONCRETE FOOTING WHEN A PAVER DECK IS PRESENT. PER PLAN POST SIZEj(2)(4) 3"xT74" x 4'6" x 6" 3"0"x 0.125" ANGLE (EXTERNAL OR INTERNAL) OR 0.125" RECEIVING CHANNEL (4) - 3/8" 0 CONCRETE I V SCREW WITH I 1" x 2" OPEN BACK ANCHORED EDGE EMBEDMENT (MIN EDGE ALUM. �� 1 4 X 3- TO CONCRETE w/ / DISTANCE FROM DEC POST 1/2" MASONRY ANCHOR - 6" EDGE=3" 6„ MAX EACH SIDE OF POST AND MIN SPACING 4") 24" O.C. MAX a G a. A . a r a-) — 4" (min) FRONT VIEW NOTE: CONCRETE SCREW ANCHOR DESIGNS ARE BASED ON TITEN HD 3/8" 0 SCREW ANCHORS, OTHER SIZE OR TYPE OF ANCHORS SHALL NOT BE USED. NOTE: FOR PATIO COVERS AND CARPORTS: DISREGARD THE 1X2 OPEN BACK SCREEN MEMBER ON THE FOUNDATION TYP. G ALUM. POST CONNECTION DETAIL S- 3 SCALE: NTS OR (2)#4 REBAR CONTINUOUS i" OVERLAP AT ALL JOINTS ON 11RS & 3" EDGE DISTANCE TYPE II MONOLITHIC SLAB MODERATE SLOPE FTG SLOPE: 2":12" - 3":12" NOTES FOR ALL FOUNDATION TYPES: i. THE FOUNDATIONS SHOWN ARE BASED ON A MINIMUM SOIL BEARING PRESSURE OF 1,500 PSF. THE BEARING CAPACITY OF THE SOIL VERIFIED BY A LICENSED CONTRACTOR PRIOR TO ANY POURING OF CONCRETE. 2. THE SLAB/FOUNDATION MUST BE CLEARED OF ALL DEBRIS, AND COMPACTED PRIOR TO POURING OF ANY CONCRETE. 3. CONCRETE MEET THE SPECIFICATIONS IN THE S-1 NOTES PAGE. K TYPE II MONOLITHIC SLAB FOOTING S-3 12" #5 REBAR 6" EMBEDMENT AND EPDXY @ 48" O.C. MAX AND 6" FROM EDGES i .' '. - ' ' I . :1 - - * .'. = ATTACHMENT DETAIL #14 X 5" SMS W/ VO NEO-WASHERS @ 8" O.C. PER PANEL FOR 3"X12" PAN ROOF USE #12X3/4" SMS W/ 1"0 NEO-PRENE WASHER 2" FROM END & 2" O.C. PER PANEL J QU Z d O F- Z ED 2" X 2" X 0.125" RECEIVING CHANNEL WITH (H) 3/8" 0 MACHINE BOLTS WITH 3/4" WASHERS EACH SIDE CROSS BEAM/ (IF NECESSARY) POST (SEE SHEET S-2 FOR SIZEI R4 ISER PAN (4) #12 SMS W/ 3/4" WASHERS PER 12" PANEL Detail C2 a CARRIER BEAM QTY. SIZE (H) 2X4/2X5 2 2X6 2X7 3 4 (H) 3/8"0 MACHINE _BOLTS WITH 3/4" WASHERS EACH SIDE (SEE CHART ABOVE) CARRIER BEAM (SEE S-2 FOR MEMBER SIZE) )TCH POST FOR BEAM PANEL TO EDGE OR INTERMEDIATE BEAM CONNECTION DETAIL SCALE: ENGINEER OF RECORD: David W. Smith P.E. FLORIDA LICENSE: 53608 Thomas L. Hanson RE FLORIDA LICENSE: 38654 Myron Max Neal P.E. FLORIDA LICENSE: 86663 oel Falardeau P.E. FLORIDA LICENSE: 70667 Erik Stuart P.E. FLORIDA LICENSE: 77605 FBC Plans & Engineering Services, Inc. 6272 Abbott Station Dr. Unit 101 Zephyrhills, FL 33542 Ph# (813)788-5314 Fax# 1-(866)824-7894 E-mail-erb@fbcplans.com Website-www.fb cplans.com C.O.A.-429054 DATE: 10/04/2021 DRAWN BY: ST I REVISION: I DATE: RO 1 RO 2 RO 3 RO 4 Job# 21_1004_020 PROJECT ADDRESS: BENT PINE DR PIERCE, FL 34951 CONTRACTOR: ARROYO ENTERPRISES 4