Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL IM5V PANELI M5V Panel 26ga (min) 24" wide 5V panel on 15132" plywood Florida Product Approval Number 29444.4 Compliance statement: This product as described has demonstrated compliance with Florida Building Code 2020, Section 1504.3.2, as required by Rule 61 G20-3, method 1 D Manufacturer: Integrity Metals, LLC 12640 Piper Dr, Ste. B, Vero Beach, FL 32960 1 772-584-2654 1 www.intregritymetalsfi.com Product: IM5V is an exposed fastener 5V style panel with a 24" coverage, and nominal rib height of 7116." Material: This product is manufactured from 26ga (min) steel with corrosion resistance per FBC 1507.4.3. Fastener: #10 x 1-112" fastener with sealing washer, compliant with FBC 1506.6. Larger diameter and longer length fasteners are acceptable. Stainless steel fasteners may be used. Substrate/Deck: Minimum 15132" thick plywood. Underlayment: Comply with FBC 1507.1.1 where applicable. Slope: Comply with FBC 1507.4.2 where applicable. Technical Documentation: This product has been tested to the UL 580-06 and UL 1897-04 (revised 2008) standard by Intertek Testing (TST-1527), report 17226.03-450-44 R0, This test report is owned by Quality Metal Roof Fabricators, who has given written authorization for Integrity Metals to use this report. Max. Allowable Loads & Method A: 116psf I Install fasteners in 12-12" pattern (one fastener per rib), at 12" o.c. max. Installation Requirements: Factor of Safety of 2.0 applied to calculate allowable loads. Evaluated By: David Eng, PE Timberlake Cove, LLC 3324 W Univ. Ave # 206, Gainesville FL 32607 PE Lic. No: 81377 CA Lic. No: 33344 www.timberiakecove.com www.integrityMeta]sFi.com Page 1 INTEGRITY METALS METAI ROOFING MADE HERE 2604 Piper St Ste B Vero Beach FL 32609 (772) 584-2654 Panel Accessories: The manufacturer does not require the use of closures, sealants, butyl, or other similar accessories between bottom edge of panel and drip edge, or in other locations. The use of closures and sealants may be advisable in some cases, however that decision is the discretion of the project owner and the installer. Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Exclusions & Limitations: Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design are outside the scope of this evaluation. This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by Rule 61 G20- 3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based on this evaluation report. This report is limited solely to documenting compliance with Rule 61 G20-3, and makes no express or implied warranty regarding performance of this product. Design Process: The load tables in this report provides one prescriptive option for the fastening requirement for the applicable wind loads for roofs within the parameters described. For roofs outside of the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or other design code in force, using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the structure is: ■ Enclosed and conforms to wind-borne debris provisions and is a regular shaped building ■ Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site location for which channeling or buffeting warrant consideration Engineering analysis may be completed by other licensed engineers for project specific approval by local authorities having jurisdiction. FL29444.4 www.IntegrityMetalsFi.com Page 2 INTEGRITY 2604 Piper St Ste B METALS Vero Beach FL 32609 METAL ROOFING MADE HERE (772) 584-2654 Design Load Tables: Select the appropriate load table that applies to the a — structure _ - 2 2 3 structure in question. 2,, 1 z ` Determine the design wind speed for the project location. 2 1 , 2 2 .._:_31 a _1 J 2 2 Use the attachment method indicated for that windspeed within each roof zone. r` /, 1 2; NOTE: ASCE 7-16 and FBC 2020 a 7-zone 2 a l adopt 3� concept. For the load tables below, the worst case {�� i was taken for each zone and reported using the a L KSP ROOF i GAKF ROOF - a standard zones 1-2-3: ' a_ 19,OF LEIS? HWON7T DWENSON ORoo. vMIGHEVER ISSM€ LER. BUT NOT LESS FHhH EI?HeR J'h OF LEPST kORfZOHTAL �iFA&4SIpN OR;sFT,99M1 Zone 1 includes zones 1 and 1' oz sa rEHmuJEo av aeslcwoeo? E ar�luaiecroe Zone 2 includes zones 2e, 2r, and 2n ROOF ZONES FOR GENERIC BUILDING Zone 3 includes zones 3e and 3r Combining these zones creates a clear, simple scheme, at the expense of some design efficiency Contact the manufacturer for further information, or consult a licensed design professional. FASTENER PATTERN AT 12" O.C. #10 X 1-12" WOOD SCREW WI SEALING WASHER Use this load table for structures which meet the following criteria Are located in Exposure B area Have either a flat roof, or gable/hip roof with max slope of 450 Have a mean roof height of 30 feet or less Method A: Install fasteners in 9- 12-12" pattern (one fastener per rib), at 12" o.c. max NR: Consult a design professional to assess the proposed installation Use this load table for structures which meet the following criteria: Are located in B, C, or D exposure area Have either a flat roof, or gablethip roof with max slope of 450 Have a mean roof height of 30 feet or less FL29444.4: 26 a IM5V on 15/32J' olvwood FL29444.4: 26 a IM5V on 15/32" pl=ood Wind 120 130 140 150 160 170 180 190 200 Wind 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A Zone 1: A AAA A A AA­L Zone 2: A A A A A A A A Zone 2: A A A A Zone 3: A A A A A A A Zone 3: A A A Use this load table for structures which meet the following criteria: Are located in Exposure B area Have either a flat roof less than 7°, hip roof with max slope of 45°, or gable roof with slope between 20° and 45' Have a mean roof height of 30 feet or less Use this load table for structures which meet the following criteria: Are located in B, C, or D exposure area Have either a flat roof less than 7°, hip roof with max slope of 45°, or gable roof with slope between 20' and 45° Have a mean roof height of 30 feet or less FL29444.4: 26cia IM5V on 15132" plywood FL29444.4: 26 a IM5V on 15132" p1mood Wind 120 130 140 150 160 170 180 190 200 Wind 120 130 140 150 160 170 180 190 200 Zone 1: A A A A A A A A A Zone 1: A A A A A A A A EN Zone 2: A AAA AAAA A Zone 2: A A A A A Zone 3: A A A A A A A A Zone 3: A A A FL29444.4 www.IntegrityMetafsFl.com Page 3