Loading...
HomeMy WebLinkAboutBegin PlansExisting Floor Plan All work to conform to FBC 2020 7th Edition Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:1 of 6 8600 S Ocean Dr #404 Jensen Beach, FL Begin December 15, 2021 Cooke Begin Remodel Cooke Construction, Inc. Renovation Division CGC1520585 Scope of Work Begin Master Bath Guest Bath Existing firewall Hall Bath Kitchen Floor Plan Elevations Scope of Work: Remove and replace vanity. Include new top, faucets, and sink. Same location Remove tub and walls around tub. Remove Shower pan and shower walls Frame for new shower to be larger and incorporate tub floor space Install new shower valve Install new shower using WEDI shower system. Using existing drain locations Install new shower panels using safety glass enclosure Install new toilet at same location Install new exhaust fan, same location as existing Install new recess lights lights using existing vanity light switch leg If needed update and/or relocate GFCI outlets to code All work to conform to FBC 2020 7th Edition Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:2 of 6 Cooke Construction, Inc.Scope of Work Begin Renovation Division Begin Remodel CGC1520585 Begin December 15, 2021 8600 S Ocean Dr #404 Cooke Jensen Beach, FL Master Bath Floor Plan Vanity Elevation Shower Elevation Scope of Work: Remove and replace vanity. Include new top, faucets, and sink. Same location Remove tub and walls around tub. Install new shower valve Install new shower with curb using WEDI shower system. Same location Install new shower doors using safety glass enclosure Install new toilet at same location Install new exhaust fan, same location as existing Install new recess lights and sconce lights using existing vanity light switch leg If needed update and/or relocate GFCI outlets to code All work to conform to FBC 2020 7th Edition Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:3 of 6 Cooke Construction, Inc.Scope of Work Begin Renovation Division Begin Remodel CGC1520585 Begin December 15, 2021 8600 S Ocean Dr #404 Cooke Jensen Beach, FL Guest Bath Scope of Work: Remove and replace vanity. Include new top, faucets, and sink. Same location Remove shower walls and pan. Install new shower valve Install new shower with curb using WEDI shower system. Same location Install new shower doors using safety glass enclosure Install new toilet at same location Install new exhaust fan, same location as existing Install new recess lights and sconce lights using existing vanity light switch leg If needed update and/or relocate GFCI outlets to code All work to conform to FBC 2020 7th Edition Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:4 of 6 Cooke Construction, Inc.Scope of Work Begin Renovation Division Begin Remodel Jensen Beach, FL CGC1520585 Begin December 15, 2021 8600 S Ocean Dr #404 Cooke All work to conform to FBC 2020 7th Edition Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:5 of 6Jensen Beach, FL CGC1520585 Begin December 15, 2021 8600 S Ocean Dr #404 Cooke Cooke Construction, Inc.Scope of Work Begin Renovation Division Begin Remodel Kitchen Scope of Work Remove and replace kitchen cabinets Install new applainces Install new countertop Install new sink, same location as existing Install new floor tile Install new GFCI outlets to meet NEC Install new recess lights in place of flourescent lights Existing firewall between units located in master bathroom matches the design below There is no plan to distrub or penetrate the existing firewall but if wall is found to be compromised from previous renovation then it will be repaired as the the diagram below to match what is existing. All work to conform to FBC 2020 7th Edition Job: Owner:Date: 1276 Business Park Place Phone:(772) 530-0659 Address:Drawn By: Jensen Beach, FL 34957 Fax:(772) 334-9911 Sheet #:6 of 6Jensen Beach, FL CGC1520585 Begin December 15, 2021 8600 S Ocean Dr #404 Cooke Cooke Construction, Inc.Scope of Work Begin Renovation Division Begin Remodel Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this listing, or as to any product covered by the listing. Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 2 ICC-ES PMG Product Certificate PMG-1189 Effective Date: May 2021 This listing is subject to re-examination in one year. www.icc-es-pmg.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council® CSI: DIVISION: 22 00 00 PLUMBING Section: 22 40 00 Plumbing Fixtures (Shower System Kit) Product certification system: The ICC-ES product certification system includes stock, or a combination of both, to verify compliance with applicable codes and standards. The system. Product: wedi Fundo Shower System and Tile Backer Board Underlayments Listee: wedi Corporation 1160 Pierson Drive, Suite 102 Batavia, IL 60510 www.wedicorp.com Compliance with the following codes: 2021, 2018, 2015, 2012 and 2009 International Plumbing Code® (IPC) 2021, 2018, 2015, 2012 and 2009 International Residential Code® (IRC) 2021, 2018, 2015, 2012 and 2009 International Building Code® (IBC) 2018, 2015, 2012 and 2009 National Standard Plumbing Code® (NSPC) 2021, 2018, 2015, 2012 and 2009 Uniform Plumbing Code® (UPC)* 2015, 2010 and 2005 National Plumbing Code of Canada** *Uniform Plumbing Code is a copyrighted publication if the International Association of Plumbing and Mechanical Officials ** National Plumbing Code of Canada is a copyrighted publication of National Research Council Canada Compliance with the following standard: ANSI A118.10-2020, Load Bearing, Bonded, Waterproof Membranes for Thin-Set Ceramic Tile and Dimension Stone Installations ASME A112.6.3-2019, Floor and Trench Drains ASTM E 96-2016, Standard Test Methods for Water Vapor Transmission of Materials ASTM E 331-00(R16), ASTM E331-00(2016) Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference ICC-ES EG 159, Evaluation Guideline for Composite Backer Board (Approved Dec 2004) ICC-ES AC 71, Acceptance Criteria for Foam Plastic Sheathing Panels Used as Water Resistive Barriers (Approved Feb 2003, Ed Revised Nov 2018) IAPMO PS 46-2012, Field-Fabricated Tiling Kits IAPMO PS 106-2015e1, Tileable Shower Receptors and Shower Kits PMG-1189 | Most Widely Accepted and Trusted Page 2 of 2 Identification: Packaging label for each as well as the ICC-ES PMG certification mark. Installation: The wedi Fundo Shower Systems shall be installed in accordance instructions and the applicable code(s). The wedi Fundo Shower system components shall be assembled and can be customized in the field. When provided drains must comply with ASME A112.18.2/CSA B125.2 as applicable. The wedi pre- sloped, ready-to-tile shower bases may be used in lieu of a CSA B45.5/IAPMO Z124 plastic shower receptors or any liner based shower installations. The wedi drain units do not require weep holes. Models: The wedi Fundo Shower Systems consist of the following: a) The wedi waterproof Fundo shower bases are waterproof, pre-sloped, ready-to-tile floor units. The shower bases with linear and point drainage include factory sealed parts integrated into the floor base and can be installed with or without curbs in recessed, barrier free installations b) The wedi waterproof building panels which are engineered as a general purpose backer board and underlayment for tile as well as an integral part of the Fundo shower system and consist of a rigid extruded polystyrene foam covered on both sides with a cement-based resin surface and reinforcing mesh for durability and bond performance with tile adhesives. c) The wedi Vapor 85 Building Panel which may be used with or without wedi shower systems. It is a specialized building panel featuring the original wedi Building Panel but with its vapor exposed side protected by wedi Subliner Dry. The wedi Vapor 85 was tested to ASTM E96 Procedure E as a complete assembly with the wedi 620 joint sealing membrane and wedi Subliner Dry sealing tape over seams and fastener points and was found to have a perm rating of 0.03 perms which meets the permeance rating requirement of 0.5 perm or less and can be used in continuous use steam shower/room applications without additional vapor retarders in accordance with Tile Council of North America (TCNA) 2014 Handbook for Ceramic Glass and Stone Tile Installation (SR613-14 and SR614-14). d) The wedi waterproof Fundo Shower system accessories which may include the following waterproof components: wedi presloped curbs, wedi niches, wedi seats, wedi benches, wedi ADA compliant ramps, wedi vapor barrier for steam room installations, wedi fasteners, wedi drain cover plates, wedi sealants, wedi Fundo drains, wedi Subliner sheet waterproofing membrane system and tapes, with Subliner Dry Bonding Flange drain, wedi Subliner Dry Tub Sealing Tape. The wedi Fundo family line includes the following: Primo, Riolito Neo, Riolito Neo Modular, Riofino, Discreto, Ligno and Onestep. The wedi Fundo Shower system components and assembly for shower installations were proven to be waterproof, water-resistant, and mold resistant when tested in accordance with A118.10-2014 and ASTM E331. The wedi drains have found to comply with ASME A112.18.2/CSA B125.2 and do not require weep holes. Conditions of Listing: 1. The wedi Fundo Shower Systems, Building Panels and System Accessories shall be installed in accordance 2. The wedi Fundo Shower Systems are under a quality control program with annual surveillance inspections by ICC-ES.