Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMEN ROOF SYSTEM5/24/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe9gmYq%2bqxZ1umxdDXgBEzeodazdTihCOpQ%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL17084-R10 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer RESISTO, a division of Soprema, Inc. Address/Phone/Email 1675 rue Haggarty Drummondville, NON-US 00000 (819) 478-2400 Ext 3327 memathieu@soprema.ca Authorized Signature Marc Mathieu memathieu@soprema.ca Technical Representative Marc Mathieu Address/Phone/Email 1675 rue Haggarty Drummondville, NON-US 00000 (819) 478-2400 Ext 3327 memathieu@soprema.ca Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/21/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL17084_R10_COI_2020_01_COI_NIEMINEN.pdf Referenced Standard and Year (of Standard)Standard Year ASTM D1970 2015 ASTM D4601 2012 ASTM D6163 2015 ASTM D6222 2011 ASTM G155 2013 FM 4470 2016 FM 4474 2011 Equivalence of Product Standards Certified By 5/24/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqv2aBQpHpQQe9gmYq%2bqxZ1umxdDXgBEzeodazdTihCOpQ%3d%3d 2/2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 12/16/2020 Date Validated 12/17/2020 Date Pending FBC Approval 12/26/2020 Date Approved 02/09/2021 Summary of Products FL #Model, Number or Name Description 17084.1 RESISTO Modified Bitumen Roof Systems SBS modified bitumen roof systems Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-135 Other: 1.) The design pressure noted herein pertains to one assembly. Refer to ER Appendix for all assemblies and maximum design pressures. 2.) Refer to ER Section 5 for Limits of Use. Installation Instructions FL17084_R10_II_2020_12_16_FINAL_ER_RESISTO_MODBIT_FL17084- R10.pdf Verified By: Robert Nieminen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL17084_R10_AE_2020_12_16_FINAL_ER_RESISTO_MODBIT_FL17084- R10.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT RESISTO a division of Soprema, Inc. 1640 rue Haggerty Drummondville, QC J2C 5P8 Canada (819) 478-2400 Evaluation Report 7215.06.14-R10 FL17084-R10 Date of Issuance: 06/20/2014 Revision 10: 12/16/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product descr ibed herein has been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: RESISTO Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in i ts entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 6-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 12/16/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing produ cts for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019 NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL17084-R10 RESISTO, a division of Soprema, Inc. Revision 10: 12/16/2020 Page 2 of 4 ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Modified Bitumen Roof Systems Compliance Statement: RESISTO Modified Bitumen Roof Systems, as produced by RESISTO, a division of Soprema, Inc., have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind resistance FM 4474 2011 1504.6 Physical properties ASTM G155 2013 1504.7 Impact resistance FM 4470 2016 1507.6.3 Material standard ASTM D1970 2015 1507.10.2 Material standard ASTM D4601 2012 1507.11.2 Material standard ASTM D6163 2015 1507.11.2 Material standard ASTM D6222 2011 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) ASTM D6163 S35860.05.12-1-R2 03/14/2013 ERD (TST6049) ASTM D1970 S44870.04.14-1 and -4 04/10/2014 ERD (TST6049) FM 4474 S47190.06.14-2 06/20/2014 ERD (TST6049) ASTM D1970 SOPC-SC8970.15 07/22/2015 ERD (TST6049) FM 4474 SOPC-SC9315.07.15 07/22/2015 ERD (TST6049) ASTM D1970 SOPC-SC8970.08.15 08/31/2015 ERD (TST6049) ASTM D6163 S43400.08.14-5-R1 05/03/2017 FM Approvals (TST1867) FM 4470 3B1A0.AM 01/08/1998 FM Approvals (TST1867) FM 4470 797-08591-267 08/14/2013 NEMO (TST6049) ASTM D6163 4S-SOPC-18-003.11.18 01/14/2019 NEMO (TST6049) Criticality 4i-SOPC-19-SSCRT-02.A 10/16/2019 NEMO (TST6049) FM 4474 4a-SOPC-19-LSWUS-01.A 03/10/2020 NEMO (TST6049) ASTM D4601 4q-SOPC-20-SSMBB-01.A 03/25/2020 NEMO (TST6049) FM 4474 4a-SOPC-20-LSWUS-01.A 09/15/2020 PRI (TST5878) FM 4474 SOP-089-02-01 07/22/2016 PRI-CMT (TST5878) ASTM D6222 PRS-026-02-01 10/28/2016 PRI (TST5878) FM 4474 SOP-104-02-01 10/31/2016 PRI (TST5878) ASTM D4601 SOP-105-02-01 11/28/2016 PRI (TST5878) Criticality (TAS 117) SOP-080-02-02 12/16/2016 PRI (TST5878) FM 4474 SOP-119-02-01 04/14/2017 PRI (TST5878) FM 4474 SOP-128-02-01 08/18/2017 UL LLC (QUA9625) Quality Control Service Confirmation 05/30/2018 UL LLC (QUA9625) Quality Control Florida BCIS Current NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL17084-R10 RESISTO, a division of Soprema, Inc. Revision 10: 12/16/2020 Page 3 of 4 4. PRODUCT DESCRIPTION: 4.1 This Evaluation Report covers RESISTO Modified Bitumen Roof Systems installed in accordance with RESISTO published installation instructions and the Limitations / Conditions of Use herein. The following RESISTO membranes make up the subject systems. TABLE 1: ROLL-GOODS FOR MODIFIED BITUMEN ROOF SYSTEMS Type Product Material Standard Plant(s) Reference Type Grade Base Sheets MODIFIED SOPRA-G ASTM D4601 II N/A OH RESISTOFLEX ASTM D4601 II N/A MS, OH SA Nail Base ASTM D4601 II N/A MS Base Ply RESISTO LB1236 ASTM D1970 N/A N/A MS, OH, QC TRI-BUILT Sand-R ASTM D1970 N/A N/A MS, OH, QC PrimeSource Building Products - ASTM D1970 N/A N/A MS, OH, QC ASTM D1970 N/A N/A MS, OH, QC SA Smooth Ply 40 ASTM D1970 N/A N/A QC SA Base ASTM D6163 I S OH, QC BITUTAK MB SMOOTH ASTM D6222 I S MO Cap Ply SA Cap GR ASTM D6163 I G OH SA Cap FR GR ASTM D6163 I G OH BITUTAK MB SMOOTH ASTM D6222 I S MO BITUTAK MB MINERAL ASTM D6222 I G MO 5.LIMITATIONS: 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 This Evaluation Report does not include evaluation of roof edge termination. Refer to FBC 1504.5 for requirements and limitations regarding edge securement for low-slope roofs. 5.6 Refer to FBC 1511 for requirements and limitations regarding recover installations. 5.6.1 For mechanically attached components over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.6.2 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL17084-R10 RESISTO, a division of Soprema, Inc. Revision 10: 12/16/2020 Page 4 of 4 5.6.3 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.7 Refer to Appendix 1 for system attachment requirements for wind load resistance. 5.7.1 and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.7.2 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 5.7.3 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.8 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components listed in Appendix 1 that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6.INSTALLATION: RESISTO Modified Bitumen Roof Systems shall be installed in accordance with RESISTO published installation instructions, subject to the Limitations / Conditions of Use noted herein. 7.BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8.MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9.QUALITY ASSURANCE ENTITY: UL LLC QUA9625; (414) 248-6409, karen.buchmann@ul.com - THE SIX (6) PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R10 for FL17084-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 10: 12/16/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 1 of 6 APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear-Off) A-1 Bonded Insulation, Bonded Roof Cover 2 1B Wood New or Reroof (Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 3 1C Wood New, Reroof (Tear-Off) or Recover C-1 Mechanically Attached Insulation, Bonded Roof Cover 3 1D Wood New, Reroof (Tear-Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 4 1E Wood New or Reroof (Tear-Off) E-2 Non-Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 4-5 1F Wood New, Reroof (Tear-Off) or Recover E-2 Non-Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 6 1G Wood New or Reroof (Tear-Off) F Non-Insulated, Bonded Roof Cover 6 The following notes apply to the systems outlined herein: 1 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 2 Fasteners shall be of sufficient length for the following engagements: Wood Deck: Min. 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. 3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address non- wind-uplift-related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components. 5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020). 6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as note instructions. RESISTOBOND: Continuous 0.5 to 0.75-inch wide ribbons, max. 12-inch o.c. DuPont INSTA STIK Quik Set Insulation Adhesive (INSTA STIK): Continuous 0.75 to 1-inch wide ribbons, max. 12-inch o.c. OMG OlyBond 500: Continuous 0.75 to 1-inch wide ribbons, max. 12-inch o.c. Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon-applied adhesive, board joints shall be staggered. Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7 Unless otherwise noted, all insulations are flat-stock or taper board of the minimum thickness noted. 8 For adhered roof insulation and board-size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020). 9 For mechanically attached components or partially-bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements. 10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R10 for FL17084-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 10: 12/16/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 2 of 6 11 For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12 For bonded insulation or membrane over existing substrates in a re-roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional. Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications. 14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top-coat thickness is 2-- through testing over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami-Dade BCCO (FBC CER1592). Use of these listings in new construction or re-roof (tear-off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction. 15 For bonded membrane applications, refer to the tables herein. The following are acceptable alternates to the listed membranes. ACCEPTABLE ALTERNATES RESISTO Product Alternate RESISTO LB1236 TRI-BUILT Sand- PrimeSource - 16 A slip-sheet of Modified Sopra-G or other approved ASTM D4601, Type II fiberglass base sheet may be loose laid atop the wood deck prior to the installation of overlying mechanically fastened components with no adverse effect on system performance. 17 1609 for determination of design wind loads TABLE 1A: WOOD DECKS NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation Layer Top Insulation Layer(s) Primer Roof Cover (Note 15) MDP (psf) Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-1. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, APA rated plywood or nominal Min. 1.5-inch ACFoam II, SOPRA- ISO s, H-Shield or SOPRA-ISO r RESISTOBOND, INSTA STIK or OlyBond 500, (Optional) Additional layers(s) base insulation RESISTOBOND, INSTA STIK or OlyBond 500, (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -52.5 W-2. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, APA rated plywood or nominal Min. 1.5-inch ACFoam II, SOPRA- ISO s, H-Shield or SOPRA-ISO r RESISTOBOND, INSTA STIK or OlyBond 500, (Optional) Additional layers(s) base insulation RESISTOBOND, INSTA STIK or o.c. (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R10 for FL17084-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 10: 12/16/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 3 of 6 TABLE1B: WOODDECKS NEWCONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Anchor Sheet Base Insulation Layer(s) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Type Attach (Notes 6,7,8) Type Attach (Notes 6,7,8) Base Ply Ply Cap Ply W-3. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, rated plywood T&G wood plank SA Nail Base 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at 4- inch wide side laps and 8-inch o.c. at three (3) equally spaced rows in the center of the sheet Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield or SOPRA-ISO r RESISTOBOND, INSTA STIK or OlyBond 500, (Optional) Additional layers(s) base insulation RESISTOBOND, INSTA STIK or OlyBond 500, (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -30.0* W-4. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, rated plywood T&G wood plank RESISTOFLEX 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at 4- inch wide side laps and 6-inch o.c. at three (3) equally spaced rows in the center of the sheet Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield or SOPRA-ISO r o.c. (Optional) Additional layers(s) base insulation o.c. (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -37.5* W-5. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, rated plywood T&G wood plank RESISTOFLEX 32 ga., 1-5/8- inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at 4- inch wide side laps and 6-inch o.c. at four (4) equally spaced rows in the center of the sheet Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield or SOPRA-ISO r INSTA STIK, 6 o.c. (Optional) Additional layers(s) base insulation INSTA STIK, 6 o.c. (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -75.0 TABLE 1C: WOOD DECKS NEW CONSTRUCTION, REROOF (TEAR-OFF) OR RECOVER SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System No. Deck (Note 1) Base Insulation (Note 13) Top Insulation Layer Primer Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply W-6. Min. 15/32-inch APA rated plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield, SOPRA-ISO r Soprema #12 DP Fasteners with Insulation Plates 1 per 1.6 ft2 (Optional) RESISTO EXTERIOR PRIMER SA Smooth Ply 40 None SA Cap GR or SA Cap FR GR -67.5 W-7. Min. 15/32-inch APA rated plywood at max. 24-inch spans (Optional) One or more layers, any combination, loose laid Min. 1.5-inch ACFoam II, SOPRA-ISO s, H-Shield, SOPRA-ISO r Soprema #12 DP Fasteners with Insulation Plates 1 per 1.6 ft2 (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self- adhering (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -67.5 NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R10 for FL17084-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 10: 12/16/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 4 of 6 TABLE1D: WOODDECKS NEWCONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D-2: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System No. Deck (Note 1) Insulation Layer(s) (Note 13) Base Sheet Roof Cover (Note 15) MDP (psf) Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply W-8. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. One or more layers, min. 1-inch, any combination, loose-laid SA Nail Base Trufast #12 DP with Insulation Plates 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows RESISTO LB1236, self-adhering (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -82.5 W-9. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, min. One or more layers, min. 1-inch, any combination, loose-laid MODIFIED SOPRA-G Trufast #12 DP with Insulation Plates 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows (Optional) BITUTAK MB SMOOTH, torch- applied (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -120.0 TABLE 1E: WOOD DECKS NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Primer Ply Cap Ply W-10. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 12 ga. annular ring shank nails 8-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3) equally spaced rows in the center of the sheet None RESISTO LB1236, self- adhering None (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch- applied -30.0* W-11. Min. 7/16-inch OSB or min. 15/32-inch APA rated plywood SOPRA-G or MODIFIED SOPRA-G 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at four (4), equally spaced, staggered center rows RESISTO EXTERIOR PRIMER SA Base RESISTO EXTERIOR PRIMER None SA Cap GR or SA Cap FR GR -37.5* W-12.Min. 19/32-inch APA rated plywood SOPRA-G 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 7-inch o.c. at the 4-inch laps and 7-inch o.c. at three (3), equally spaced, staggered center rows RESISTO EXTERIOR PRIMER SA Base RESISTO EXTERIOR PRIMER None SA Cap GR or SA Cap FR GR -37.5 W-13.Min. 15/32-inch APA rated plywood SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced, staggered center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -45.0 W-14.Min. 15/32-inch APA rated plywood SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced, staggered center rows None RESISTO LB1236, self- adhering None (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch- applied -45.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R10 for FL17084-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 10: 12/16/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 5 of 6 TABLE1E: WOODDECKS NEWCONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (NAILS), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Primer Ply Cap Ply W-15. Min. 15/32-inch OSB or min. 15/32-inch APA rated plywood SOPRA-G 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at four (4), equally spaced, staggered center rows RESISTO EXTERIOR PRIMER SA Base RESISTO EXTERIOR PRIMER None SA Cap GR or SA Cap FR GR -45.0 W-16.Min. 15/32-inch APA rated plywood SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 12 ga. annular ring shank nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at four (4), equally spaced, staggered center rows None RESISTO LB1236, self- adhering None (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch- applied -52.5 W-17. Min. 19/32-inch APA rated plywood or plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -60.0 W-18. Min. 19/32-inch APA rated plywood or plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with 11 ga. annular ring shank nails 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows None RESISTO LB1236, self- adhering None (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch- applied -60.0 W-19. APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSBor min. 15/32- inch APA rated plywood GAP Organic Base Sheet (#43) Simplex MAXX Cap Fastener 6-inch o.c. at the 3-inch laps and 6-inch o.c. at three (3), equally spaced center rows None (Optional) BITUTAK MB SMOOTH, torch-applied None (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch- applied -60.0 W-20. Min. 19/32-inch APA rated plywood or plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with ring shank roofing nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at three (3), equally spaced center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -90.0 W-21. Min. 19/32-inch APA rated plywood or plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with ring shank roofing nails 6-inch o.c. at the 4-inch laps and 6-inch o.c. at three (3), equally spaced center rows None RESISTO LB1236, self- adhering None (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch- applied -90.0 W-22. Min. 19/32-inch APA rated plywood or plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with ring shank roofing nails 4-inch o.c. at the 4-inch laps and 4-inch o.c. at four (3), equally spaced center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -105.0 W-23. Min. 19/32-inch APA rated plywood or plank SA Nail Base 32 ga., 1-5/8-inch diameter tin caps with ring shank roofing nails 4-inch o.c. at the 4-inch laps and 4-inch o.c. at four (3), equally spaced center rows None RESISTO LB1236, self- adhering None (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch- applied -105.0 NEMO|etc. NEMO ETC, LLC Evaluation Report 7215.06.14-R10 for FL17084-R10 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 10: 12/16/2020 ©2019 NEMO ETC, LLC RESISTO, a division of Soprema, Inc.; (819) 478-2400 Appendix 1, Page 6 of 6 TABLE1F: WOODDECKS NEWCONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE E-2: NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System No. Deck (Note 1) Base Sheet Primer Roof Cover (Note 15) MDP (psf) Base Fasteners (Note 11) Attach Base Ply Primer Ply Cap Ply W-24. Min. 19/32-inch APA rated plywood or plank SA Nail Base Trufast #12 DP with Insulation Plates 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows None (Optional) SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -127.5 W-25. Min. 19/32-inch APA rated plywood or plank SA Nail Base Trufast #12 DP with Insulation Plates 8-inch o.c. at the 4-inch laps and 8-inch o.c. at three (3), equally spaced center rows None RESISTO LB1236, self- adhering None (Optional) BITUTAK MB SMOOTH, torch- applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch- applied -127.5 TABLE 1G: WOOD DECKS NEW CONSTRUCTION OR REROOF (TEAR-OFF) SYSTEM TYPE F: NON-INSULATED, BONDED ROOF COVER System No. Deck (Notes 1 & 12) Primer Roof Cover (Note 15) MDP (psf) Base Ply Primer Ply Cap Ply W-26.Min. 7/16-inch APA rated OSB or min. 15/32-inch APA rated plywood RESISTO EXTERIOR PRIMER SA Base RESISTO EXTERIOR PRIMER None SA Cap GR or SA Cap FR GR -45.0 W-27. Min. 15/32-inch APA rated OSB None SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -67.5 W-28. Min. 15/32-inch APA rated OSB RESISTO EXTERIOR PRIMER SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -75.0 W-29.APA rated, 7/16 CAT, 0.418 in., Exposure 1 OSB, (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self-adhering None (Optional) BITUTAK MB SMOOTH, torch-applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -97.5 W-30. Min. 15/32-inch APA rated plywood None SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -105.0 W-31. Min. 15/32-inch APA rated plywood RESISTO EXTERIOR PRIMER SA Smooth Ply 40 None None SA Cap GR or SA Cap FR GR -112.5 W-32. (Optional) RESISTO EXTERIOR PRIMER RESISTO LB1236, self-adhering None (Optional) BITUTAK MB SMOOTH, torch-applied BITUTAK MB SMOOTH or BITUTAK MB MINERAL, torch-applied -135.0 4/28/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtFPmdYiNDWrzpAW2f4z32FAkyOs%2fFQU8c%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL1608-R7 Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer OMG, Inc. Address/Phone/Email 153 Bowles Rd Agawam, MA 01001 (800) 633-3800 SChilds@omginc.com Authorized Signature Stephen Childs SChilds@omginc.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Cements-Adhesives-Coatings Compliance Method Certification Mark or Listing Certification Agency Miami-Dade BCCO - CER Validated By Robert Nieminen, PE, NEMO ETC, LLC Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard)Standard Year ASTM D1621 2016 ASTM D1622 2020 ASTM D1623 2017 ASTM D1929 2016 ASTM D2842 2019 ASTM D2856 1998 ASTM E84 2016 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A 4/28/2021 Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqtFPmdYiNDWrzpAW2f4z32FAkyOs%2fFQU8c%3d 2/2 Date Submitted 12/22/2020 Date Validated 12/22/2020 Date Pending FBC Approval Date Approved 01/01/2021 Summary of Products FL #Model, Number or Name Description 1608.1 OMG Low Rise Membrane Adhesive Two part urethane adhesive for fleece-back single ply roof membrane securement. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Limited to roof cover uplift ratings per Florida Product Approval for the roof system. Certification Agency Certificate FL1608_R7_C_CAC_16030306.pdf Quality Assurance Contract Expiration Date 10/13/2021 Installation Instructions FL1608_R7_II_16030306.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 1608.2 OMG OlyBond, OlyBond 500 and OlyBond 500 Green Adhesives Two-part urethane adhesives for insulation securement. Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Limited to roof cover uplift ratings per Florida Product Approval for the roof system Certification Agency Certificate FL1608_R7_C_CAC_19090403.pdf Quality Assurance Contract Expiration Date 07/29/2022 Installation Instructions FL1608_R7_II_19090403.pdf Verified By: Miami-Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: NOA No.: 19-0904.03 Expiration Date: 07/29/22 Approval Date: 05/14/20 Page 1 of 4 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy OMG, Inc. 153 Bowles Road Agawam, MA 01001-0508 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: OMG OlyBond, OlyBond 500 & OlyBond 500 Green Adhesives LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 17-0519.04 and consists of pages 1 through 4. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 19-0904.03 Expiration Date: 07/29/22 Approval Date: 05/14/20 Page 2 of 4 ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Cements, Adhesives and Coatings Material: Polyurethane SCOPE: This approves OMG OlyBond Classic, OlyBond 500, OlyBond 500 Canister, OlyBond 500 SpotShot, OlyBond 500 Green & OlyBond 500 Green SpotShot adhesives as manufactured by OMG, Inc., as described in this Notice of Acceptance. The use of this acceptance is limited to those roof assemblies were OMG OlyBond Classic, OlyBond 500, OlyBond 500 Canister, OlyBond 500 SpotShot, OlyBond 500 Green & OlyBond 500 Green SpotShot adhesives are specifically listed as an accepted component. PRODUCT DESCRIPTION: Spray Polyurethane Foam with the properties described below: Description Test Properties OMG OlyBond Classic Flame Spread Index ASTM E84 15 Smoke Develop Index ASTM E84 10 Self Ignition Temperature ASTM D1929-91 698° F Density @ 73° F ASTM D 1622 5.03 lbs./ft3 Compressive Strength @ 10% deformation ASTM D 1621 18.02 psi Tensile ASTM D 1623 42.04 psi Water Absorption ASTM D 2842 2.75% Packaging Options Drum: 15 or 55 gal Note: The physical properties listed above are presented at typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. OMG OlyBond 500, OlyBond 500 Canister, OlyBond500 SpotShot Flame Spread Index ASTM E84 15 Smoke Develop Index ASTM E84 10 Self Ignition Temperature ASTM D1929-91 698° F Density @ 73° F ASTM D 1622 5.03 lbs./ft3 Compressive Strength @ 10% deformation ASTM D 1621 18.02 psi Tensile ASTM D 1623 2.04 psi Water Absorption ASTM D 2842 2.75% Packaging Options SpotShot Cartridge: 1500 ml Bag-in-Box: 5 gal Drum: 15 gal Canister: 68 lbs Note: The physical properties listed above are presented at typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 19-0904.03 Expiration Date: 07/29/22 Approval Date: 05/14/20 Page 3 of 4 OMG OlyBond 500 Green, OlyBond 500 Green SpotShot Flame Spread Index ASTM E84 15 Smoke Develop Index ASTM E84 10 Self Ignition Temperature ASTM D1929-91 698° F Density @ 73° F ASTM D 1622 3.38 lbs./ft3 Compressive Strength @ 10% deformation ASTM D 1621 25.89 psi Tensile ASTM D 1623 67.64 psi Water Absorption ASTM D 2842 20.1% Packaging Options SpotShot Cartridge: 1500 ml Bag-in-Box: 5 gal Drum: 15 gal Note: The physical properties listed above are presented at typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MANUFACTURING LOCATION: 1. Rockford, MN EVIDENCE SUBMITTED: Test Agency Test Identifier Test Specification Date UL LLC UL 723 R18910 06/27/17 FM Approvals 3001472 4450/4470 04/14/99 3008869 4470 03/19/01 3014692 4470 08/05/03 3031350 4470 09/27/07 RCMA Americas, Inc. CX23A7A Physical Properties 03/07/17 CX16C7A Physical Properties 04/19/17 R & D Services, Inc. RD17092 ASTM D2842 02/16/17 RD17420 ASTM D2842 06/30/17 LIMITATIONS: 1. OMG OlyBond Classic, OlyBond 500, OlyBond 500 Canister, OlyBond 500 SpotShot, OlyBond 500 Green & OlyBond 500 Green SpotShot adhesives shall have a quality control testing program by an approved independent listing agency having unannounced follow-up visits. Follow up test results shall be made available to Miami-Dade County Product Control upon request. 2. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.: 19-0904.03 Expiration Date: 07/29/22 Approval Date: 05/14/20 Page 4 of 4 INSTALLATION: OMG OlyBond Classic, OlyBond 500, OlyBond 500 Canister, OlyBond 500 SpotShot, OlyBond 500 Green & OlyBond 500 Green SpotShot adhesives shall be installed in strict compliance with the Roof Assembly Notice of Acceptance and manufacturer LABELING: OMG OlyBond Classic, OlyBond 500, OlyBond 500 Canister, OlyBond 500 SpotShot, OlyBond 500 Green & OlyBond 500 Green SpotShot adhesives shall be labeled in compliance with TAS 121 and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable Building Code in order to properly evaluate the installation of this system. This Notice of Acceptance on its own cannot be used to obtain a building permit. END OF THIS ACCEPTANCE