Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL12/22/21, 11:16 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsji1xY3FEvdOuNXbp3xre5LH10lKT0BV%2b720SmpVyPQg%3d%3d 1/2 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL #FL36904-R3 Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Tri County Metals Address/Phone/Email 301 SE 16th Street Trenton, FL 32693 (352) 463-8400 testing@tricountymetals.com Authorized Signature Jason Klinkenberg testing@tricountymetals.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Zachary R. Priest Florida License PE-74021 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL36904_R3_COI_TCM20001.3a 2020 FBC Eval Metal Roofing non-HVHZ Final2.pdf Referenced Standard and Year (of Standard)Standard Year ASTM B 117 2016 ASTM E 1592 2005 ASTM G 155 2013 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By 12/22/21, 11:16 AM Florida Building Code Online https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqsji1xY3FEvdOuNXbp3xre5LH10lKT0BV%2b720SmpVyPQg%3d%3d 2/2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 06/11/2021 Date Validated 06/17/2021 Date Pending FBC Approval 07/04/2021 Date Approved 08/10/2021 Date Revised 12/17/2021 Summary of Products FL #Model, Number or Name Description 36904.1 TCM-LOK, 5V and Ultra Rib Non-structural metal roofing panels Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +0/-150 Other: See evaluation report for limits of use. Installation Instructions FL36904_R3_II_TCM20001.3a 2020 FBC Eval Metal Roofing non-HVHZ Final2.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL36904_R3_AE_TCM20001.3a 2020 FBC Eval Metal Roofing non-HVHZ Final2.pdf Created by Independent Third Party: Yes 36904.2 TCM-LOK, 5V and Ultra Rib Non-structural metal roofing panels for the HVHZ Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: No Impact Resistant: N/A Design Pressure: +0/-150 Other: See evaluation report for limits of use. Installation Instructions FL36904_R3_II_TCM20001.3b 2020 FBC Eval Metal Roofing HVHZ final.pdf Verified By: Zachary R. Priest PE-74021 Created by Independent Third Party: Yes Evaluation Reports FL36904_R3_AE_TCM20001.3b 2020 FBC Eval Metal Roofing HVHZ final.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: a CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 1 of 7 Page 1 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. Registry No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020) Manufacturer: TRI COUNTY METALS Issued December 17, 2021 301 SE 16th Street Trenton, FL 32693 (877) 766-3309 www.tricountymetals.com Manufacturing Locations: Trenton, FL Quality Assurance: Keystone Certifications, Inc. (QUA1824) SCOPE Category: Roofing Subcategory: Metal Roofing Code Edition: Florida Building Code, 7th Edition (2020) Code Sections: 1504.3, 1504.3.2 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) 945T0002 ASTM B 117 2016 PRI Construction Materials Technologies (TST5878) 945T0004 ASTM G 155 2013 PRI Construction Materials Technologies (TST5878) 1272T0002 ASTM B 117 TAS 110 2016 2000 PRI Construction Materials Technologies (TST5878) 1272T0003 ASTM B 117 TAS 110 2016 2000 PRI Construction Materials Technologies (TST5878) 1272T0005 ASTM G 155 TAS 110 2013 2000 PRI Construction Materials Technologies (TST5878) 1272T0006 ASTM G 155 TAS 110 2013 2000 PRI Construction Materials Technologies (TST5878) 1930T0001 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0002 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0003 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0004 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0009 FM 4471 1992 PRI Construction Materials Technologies (TST5878) 1930T0010 ASTM B 117 TAS 110 2016 2000 PRI Construction Materials Technologies (TST5878) 1930T0011 ASTM G 155 TAS 110 2013 2000 PRI Construction Materials Technologies (TST5878) 1930T0013 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0015 UL 580 UL 1897 2006 2012 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 2 of 7 Page 2 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) Entity Report No. Standard Year PRI Construction Materials Technologies (TST5878) 1930T0016 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0017 ASTM E 1592 2005(2012) PRI Construction Materials Technologies (TST5878) 1930T0018 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0019 UL 580 UL 1897 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0020 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0026 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0027 TAS 125 UL 580 UL 1897 2003 2006 2012 PRI Construction Materials Technologies (TST5878) 1930T0028 ASTM C 794 2001 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 3 of 7 Page 3 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) PRODUCT DESCRIPTION TCM-LOK 1 in. Profile: 1 in. snap lock seam; Max.16 in. coverage Description: Non-structural, snap lock standing seam roof panel with 7/8 in. slotted nail strip Material: Min. 24ga ASTM A792 AZ50 steel coated with Fluropon® or WeatherXL or A792 AZ55 steel (Fy = min. 50 ksi); or Min. 0.032 in. ASTM B209, 3105 H22 aluminum coated with Fluropon® (Fy = min. 25 ksi); Shall conform with FBC Section 1507.4.3 TCM-LOK 1.5 in. Profile: 1.5 in. snap lock seam; Max. 15 in. coverage Description: Non-structural, snap lock standing seam roof panel with 7/8 in. slotted nail strip Material: Min. 24 ga. ASTM A792 AZ50 steel coated with Fluropon® or WeatherXL or A792 AZ55 steel (Fy = min. 50 ksi); Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 4 of 7 Page 4 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) 1.75 SS-LOK Profile: 1.75 in. snap lock standing seam; Max. 16 in. coverage Description: Non-structural, snap lock standing seam roof panel Material: Min. 0.040 in. ASTM B209, 3104 H22 aluminum coated with Fluropon® (Fy = min. 25 ksi); Shall conform with FBC Section 1507.4.3 1.5 MS-LOK Profile: 1.5 in. mechanical seam; Max. 16 in. coverage Description: Non-structural, standing seam roof panel; 180° double lock mechanical seam Material: Min. 24 ga. A792 AZ55 steel (Fy = min. 50 ksi); Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 5 of 7 Page 5 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) 2 MS-LOK Profile: 2 in. mechanical seam; Max. 18.75 in. coverage Description: Non-structural, standing seam roof panel; 180° double lock mechanical seam Material: Min. 24 ga. A792 AZ50 steel (Fy = min. 50 ksi); Shall conform with FBC Section 1507.4.3 5V Profile: 3/8 in. ribs at 12 in. o.c.; 24 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 26 ga. ASTM A653 G90, ASTM A792 AZ50 steel coated with Fluropon® or WeatherXL or A792 AZ55 steel (Fy = min. 50 or 80 ksi); or Min. 0.032 in. ASTM B209, 3105 H22 aluminum coated with Fluropon ® (Fy = min. 27 ksi); Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 6 of 7 Page 6 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) Ultra Rib Profile: 3/4 in. ribs at 9 in. o.c.; 36 in. coverage Description: Non-structural, through fastened roof panel Material: Min. 29 ga. ASTM A653 G90, ASTM A792 AZ50 steel coated with Fluropon® or WeatherXL or A792 AZ55 steel (Fy = min. 80 ksi); Shall conform with FBC Section 1507.4.3 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 7 of 7 Page 7 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) LIMITATIONS 1. This report is not for use in the HVHZ. 2. Fire classification is not within the scope of this evaluation. 3. The roof deck, wood battens and their attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 4. Roof slope shall be in accordance with FBC Section 1507.4.2 5. Reroofing shall be in accordance with Section 1511. 6. Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer’s published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 7. All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products und er this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. APPENDICES 1) APPENDIX A – Installation (3 pages) 2) APPENDIX B – Approved Roof Systems (5 pages) 3) APPENDIX C – Design Wind Loads (4 pages) This item has been digitally signed and sealed by Zachary R. Priest, PE, on 12/17/2021. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 2021.12.17 16:09:34 -05'00' A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 1 of 3 Page 1 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX A INSTALLATION Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system. Unless otherwise specified in this report the following installation details shall be met for the named products: Component Product Installation Detail Fasteners #10-12 Pancake Type A screw Shall penetrate through the sheathing a minimum 3/8 in. Shall be corrosion resistant in accordance with FBC section 1507.4.4. #10-9 PanclipSS MTW low profile head wood screw #10-9 Panclip MTW low profile head wood screw #9-15 Woodgrip HWH wood screw with sealing washer #9-15 Evergrip HWH wood screw with sealing washer #12-8 Woodgrip XG HWH wood screw with sealing washer Clips 1.75 in. SL Clip 18 ga. SFS 1-3/4 in. Snap Lock Clip; 1.875 in. tall with 3.75 in. base 1.5 in. ML Clip 1-1/2 in. 1-piece expansion clip; 22 ga.vertical tab; 16 ga. base; 4.5 in. long A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 2 of 3 Page 2 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX A Component Product Installation Detail Clips – Cont’d 2 in. ML Clip 2i n. 1-piece expansion clip; 22 ga.vertical tab; 16 ga. base; 4.5 in. long Seam Sealants TiteBond Weathermaster Metal Roof Sealant Shall be applied in 1/4 in.- 5/16 in. continuous beads on the male rib along the seam Geocel 2300 Novaflex Metal Roof Sealant A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 3 of 3 Page 3 of 19 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX A Fastening Details Nomenclature Attachment TCM-LOK 5V Ultra Rib Ultra Rib 2 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX B APPROVED ROOF SYSTEMS The following notes shall be observed when using the assembly tables below. 1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1504.9. 2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below. 3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly s tated for the selected assembly. 4. The on-center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system. 5. Unless otherwise specified, Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32 in. thick APA Span-Rated plywood sheathing at maximum 24 in. span. 6. No. 2 SYP wood battens used over solidly sheathed decks shall be installed parallel to the eave and 90 degrees to the roof trusses/rafters. Wood battens shall be located under each fastener row. Panel fasteners shall be installed through the battens and into the roof deck. Battens may be secured in place prior to fastening the roof panels. 7. For metal roofing installed over open framing, rational analysis shall be conducted by a qualified design professional in accordance with Section 2210.1.1.2 and Chapter 16. Maximum Design Pressures listed below are established based on uniform static loading in accordan ce with Section 1504.3.2 and ASTM E 1592. Roof System Numbers and Definitions LOK-W-# TCM-LOK over Wood Deck (New or Existing) SSLOK-W -# 1.75” SS-LOK over Wood Deck (New or Existing) MSLOK-W-# MS-LOK over Wood Deck (New or Existing) 5V-S-W -# Min. 26 ga. 5V over Wood Deck (New or Existing) 5V-Al-W-# Min. 0.032 Al 5V over Wood Deck (New or Existing) RIB-W-# Ultra Rib over Wood Deck (New or Existing) RIB-# Ultra Rib over Open Framing (New or Existing) Approved Systems for TCM-LOK over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) LOK-W-1 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier As required per FBC Min. 0.032 Al TCM-LOK 1 in. 16 in. coverage TCM-LOK attachment with #10-12 Pancake Type A screws spaced 5-1/4 in. o.c.; Seam Sealant (see INSTALLATION for list of allowable products) applied to male rib. -110 LOK-W-2 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier As required per FBC Min. 24 ga. TCM-LOK 1.5 in. 15 in. coverage TCM-LOK attachment with #10-12 Pancake Type A screws spaced 5-1/4 in. o.c.; Seam Sealant (see INSTALLATION for list of allowable products) applied to male rib. -122.5 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX B Approved Systems for TCM-LOK over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) LOK-W-3 Min. 15/32 CDX plywood OPTIONAL Approved fire barrier As required per FBC Min. 24 ga. TCM-LOK 1 in. 16 in. coverage TCM-LOK attachment with #10-12 Pancake Type A screws spaced 5-1/4 in. o.c.; Seam Sealant (see INSTALLATION for list of allowable products) applied to male rib. -142.5 Approved Systems for Min. 0.040 Al 1.75 SS-LOK over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) SSLOK-W -1 Min. 15/32 CDX plywood - As required per FBC Min. 0.040 Al 1.75 SS-LOK 16 in. coverage 1.75 in. SL Clips spaced 16 in. o.c. at the panel seam secured with two (2) #10-9 PanclipSS MTW low profile head screws per clip -90 SSLOK-W -2 Min. 15/32 CDX plywood - As required per FBC Min. 0.040 Al 1.75 SS-LOK 16 in. coverage 1.75 in. SL Clips spaced 6 in. o.c. at the panel seam secured with two (2) #10-9 PanclipSS MTW low profile head screws per clip -120 Approved Systems for Min. 24 ga. MS-LOK over Wood Deck (New or Existing) System No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) MSLOK-W -1 Min. 15/32 CDX plywood - As required per FBC Min. 24 ga. 2 MS-LOK 18.75 in. coverage 2 in. ML Clips spaced 16 in. o.c. at the panel seam secured with two (2) #10-9 x min. 1.5 in. Panclip MTW low profile screws per clip; Panels mechanically seamed with 180o double lock -116.25 MSLOK-W -2 Min. 15/32 CDX plywood - As required per FBC Min. 24 ga. 2 MS-LOK 18.75 in. coverage 2 in. ML Clips spaced 8 in. o.c. at the panel seam secured with two (2) #10-9 x min. 1.5 in. Panclip MTW low profile screws per clip; Panels mechanically seamed with 180o double lock -120 MSLOK-W -3 Min. 15/32 CDX plywood - As required per FBC Min. 24 ga. 1.5 MS-LOK 16 in. coverage 1.5 in. ML Clips spaced 16 in. o.c. at the panel seam secured with two (2) #10-9 x min. 1.5 in. Panclip MTW low profile screws per clip; Panels mechanically seamed with 180o double lock -142.5 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX B Approved Systems for Min. 26 ga. 5V Crimp over Wood Deck (New or Existing) System No. Deck Battens (Note 6) Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 5V-S-W-1 Min. 15/32 CDX plywood - - As required per FBC Min. 26 ga., Grade 50 5V Crimp 24 in. coverage 5V attachment with #9-15 Woodgrip with sealing washers spaced 16 in. o.c. -67.5 5V-S-W-2 Min. 15/32 CDX plywood OPTIONAL No. 2 SYP min. 1x4 wood battens OPTIONAL Approved fire barrier As required per FBC Min. 26 ga., Grade 80 5V Crimp 24 in. coverage 5V attachment with #12-8 Woodgrip XG screws with sealing washers spaced 16 in. o.c. -86.25 5V-S-W-3 Min. 15/32 CDX plywood OPTIONAL No. 2 SYP min. 1x4 wood battens OPTIONAL Approved fire barrier As required per FBC Min. 26 ga., Grade 80 5V Crimp 24 in. coverage 5V attachment with #9-15 Woodgrip or #12-8 Woodgrip XG screws with sealing washers spaced 12 in. o.c. -90 5V-S-W-4 Min. 15/32 CDX plywood - - As required per FBC Min. 26 ga., Grade 50 5V Crimp 24 in. coverage 5V attachment with #12-8 Woodgrip XG screws with sealing washers spaced 12 in. o.c. -101.25 5V-S-W-5 Min. 15/32 CDX plywood - - As required per FBC Min. 26 ga., Grade 50 5V Crimp 24 in. coverage 5V attachment with #9-15 Woodgrip or #12-8 Woodgrip XG screws with sealing washers spaced 6 in. o.c. -120 5V-S-W-6 Min. 15/32 CDX plywood OPTIONAL No. 2 SYP min. 1x4 wood battens OPTIONAL Approved fire barrier As required per FBC Min. 26 ga., Grade 80 5V Crimp 24 in. coverage 5V attachment with #12-8 Woodgrip XG screws with sealing washers spaced 9 in. o.c. -120 5V-S-W-7 Min. 15/32 CDX plywood OPTIONAL No. 2 SYP min. 1x4 wood battens OPTIONAL Approved fire barrier As required per FBC Min. 26 ga., Grade 80 5V Crimp 24 in. coverage 5V attachment with #9-15 Woodgrip or #12-8 Woodgrip XG screws with sealing washers spaced 6 in. o.c. -135 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX B Approved Systems for Min. 0.032 Al 5V Crimp over Wood Deck (New or Existing) System No. Deck Battens (Note 6) Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) 5V-Al-W-1 Min. 15/32 CDX plywood - OPTIONAL Approved fire barrier As required per FBC Min. 0.032 Al 5V Crimp 24 in. coverage 5V attachment with #9-15 Evergrip screws with sealing washers spaced 9 in. o.c. -127.5 5V-Al-W-2 Min. 15/32 CDX plywood - OPTIONAL Approved fire barrier As required per FBC Min. 0.032 Al 5V Crimp 24 in. coverage 5V attachment with #9-15 Evergrip screws with sealing washers spaced 6 in. o.c. -150 Approved Systems for Ultra Rib over Wood Deck (New or Existing) System No. Deck Battens (Note 6) Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf) RIB-W-1 Min. 15/32 CDX plywood with OPTIONAL single layer of asphalt shingles No. 2 SYP min. 1x4 wood battens OPTIONAL Approved fire barrier As required per FBC Min. 29 ga. Ultra Rib 36 in. coverage Ultra Rib 2 attachment with #9-15 Woodgrip screws spaced 24 in. o.c -67.5 RIB-W-2 Min. 15/32 CDX plywood OPTIONAL No. 2 SYP min. 1x4 wood battens OPTIONAL Approved fire barrier As required per FBC Min. 26 ga. Ultra Rib 36 in. coverage Ultra Rib attachment with #12-8 Woodgrip XG screws spaced 24 in. o.c -116.25 RIB-W-3 Min. 15/32 CDX plywood OPTIONAL No. 2 SYP min. 1x4 wood battens OPTIONAL Approved fire barrier As required per FBC Min. 26 ga. Ultra Rib 36 in. coverage Ultra Rib attachment with #9-15 Woodgrip screws spaced 12 in. o.c -135 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX B Approved Systems for Ultra Rib over Open Framing (New or Existing) – Note 7 System No. Battens Roof Panel Panel Attachment MDP (psf) RIB-1 No. 2 SYP 1x4 wood battens installed max. 24 in. o.c. with two (2) min. 3 in. x #9 wood screws placed at each batten and truss/rafter intersection. Roof trusses/rafters shall be spaced max. 24 in. o.c. and shall be 90 degrees to the battens. Min. 29 ga. Ultra Rib 36 in. coverage with max. 2 in. overhang at eave Ultra Rib attachment with #9-15 x 1.5 in. Woodgrip screws installed into each batten +45 -105 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX C DESIGN WIND LOADS The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following provisions: 1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC. 2. Exposure B, C and D shall be as defined in section 1609 of the FBC. 3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 12:12 4. All calculations are based on an effective wind area of 10-ft2 or less. 5. Topographic factors such as escarpments or hills have been excluded from the analysis 6. Overhangs have been excluded from the analysis. 7. Wind directionality factor, Kd = 0.85 8. Vult is shown in the tables below. Design wind loads are calculated using Vasd = Vult√0.6 per 1609.3.1. 9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r 10. Zone 3 is inclusive of Zone 3e and Zone 3r 11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional 12. Zones 1, 2, and 3 shall be defined as shown below. Dimension “a” shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller, but not less than either 4% of the least horizontal dimension or 3ft Gable Hip . a a a 3 3 a 2 2 1 2 3 a 3 2 a 3 2 2 3 3 1 2 2 3 a a a a a 3 3 2 2 1 1 2 2 1 a 2 2 1 3 3 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX C Gable/Hip Roofs in Exposure B (Roof slope between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) 120 130 140 150 160 170 180 190 200 Enclosed/ Partially Open 1 20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6 25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3 30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7 40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5 50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2 60 -34.8 -40.9 -47.4 -54.4 -61.9 -69.9 -78.4 -87.3 -96.8 2 20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0 25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3 30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3 40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2 50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5 60 -50.8 -59.6 -69.2 -79.4 -90.3 -102.0 -114.3 -127.4 -141.2 3 20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4 25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3 30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2 40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0 50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9 60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8 Partially Enclosed 1 20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6 25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2 30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2 40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2 50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9 60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2 2 20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0 25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2 30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8 40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9 50 -54.1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 -150.2 60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6 3 20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4 25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2 30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7 40 -59.3 -69.6 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7 50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6 60 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.2 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX C Gable/Hip Roofs in Exposure C (Roof slope between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) 120 130 140 150 160 170 180 190 200 Enclosed/ Partially Open 1 20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5 25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0 30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6 40 -42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4 50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1 60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7 2 20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5 25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1 30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8 40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7 50 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 -163.4 -181.0 60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7 3 20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7 25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6 30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5 40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3 50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2 60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1 Partially Enclosed 1 20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9 25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2 30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5 40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5 50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2 60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5 2 20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9 25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3 30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7 40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8 50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1 60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5 3 20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1 25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7 30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4 40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4 50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2 60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 -221.0 -244.9 A CREEK Technical Services, LLC TCM20001.4a FL36904-R4 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express no r imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. TRI COUNTY METALS Metal Roofing (non-HVHZ) APPENDIX C Gable/Hip Roofs in Exposure D (Roof slope between 2:12 and 12:12) Building Type Zone Mean Roof Height (ft) Basic Wind Speed (mph) 120 130 140 150 160 170 180 190 200 Enclosed/ Partially Open 1 20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0 25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5 30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1 40 -50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9 50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6 60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1 2 20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4 25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0 30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6 40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6 50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9 60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6 3 20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2 25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1 30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0 40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8 50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7 60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6 Partially Enclosed 1 20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8 25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2 30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5 40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5 50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1 60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5 2 20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2 25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6 30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1 40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2 50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5 60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9 3 20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1 25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7 30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4 40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4 50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2 60 -102.2 -120.0 -139.1 -159.7 -181.7 -205.1 -230.0 -256.2 -283.9 END OF REPORT