Loading...
HomeMy WebLinkAboutSLC-2010-0677 Compaction Test 104Tested For: 14150 NW 3rd Avenue Miami, Florida - 33168 Jose Barreto Cc: Attention: Title:Project Manager Jose Barreto (joseb@ceielectric.net) Project #:7112-21-182-002 Project:A2P0048A Address:14101 South Angle Road West St. Lucie, Florida - 34945, United States Joel Hernandez Permit #: Inspector: CEI, LLC 04/26/2021Report Date: General Location:Generator Pad Test Method:ASTM D-6938 (Nuclear)Field Activity Date:04/23/2021 Gauge Make:Troxler Project Specifications:98 % Gauge Model:3430 Modified Proctor(AASHTO T-180)Gauge S/N:28286 Retest Required:Yes X NoVertical Reference: Test Date Proctor Number Soil Description Max. Dry Density (pcf) Optimum Moisture (%) 04/23/2021 L1 Light brown sand with rock 119.0 9.5 Test No Elevation or Re-Test No Depth (Inch)Test Location Proctor Max Density (lbs/ft^3) Proctor Optimum Moisture (%) Field Percent Moisture (%) Field Density (lbs/ft^3) Percent Compaction (%) Spec: 98 Meet Spec ? 1 Pad 12 Center Northside of Pad 119.0 9.5 7.8 117.9 99.1 Yes 2 Pad 12 Center Southside of Pad 119.0 9.5 6.9 118.5 99.6 Yes 0 - 0 - 0 - Remarks: Report Copied to: Notes: As requested, a representative from our company arrived on site as scheduled and performed the above test. These test results apply only to the specific locations noted and do not represent any other location. Reports may not be reproduced except in full, without permission. Field Compaction Tests