Loading...
HomeMy WebLinkAboutCOMPACTION TEST (LIFT 2)Oederal .0ngineering ®Oesting, Inc. Field Density Tests of Compacted Soils Method D-6938 Project: Proposed Single Family Home Address: 5804 Raintree Trail, Fort Pierce, FL 34982 Area Tested: Material Type: Building Pad n-1, Drn n Canrl Company: Groza Builders, Inc. Address: 1332 Biltmore Street --- rya 1 M `:ZAGP'2 Phone: 954-784-2941 E-Fax: 954-784-7875 admin@fed-eng.com www.fed-eng.com 1 .. Date: January 12, 2022 Order #: 22CMT0131 Permit #: - Tech: TS Compaction Req.: Proctor Method: 98% ASTM D-1557 Test # 1'UIL Jl. Lui,1c, TEST LOCATION Probe Depth Elev. Moist �0 Dry Density PCF Proctor Value PCF Optimum Moisture % Compaction Pass 12" 2L 3 519.1]::105.5 108.6 102.0 12.0 106.5% Yes 1 NW Corner of BuildingPad 12" 2L 102.0 12.0 103.4% Yes 2 NE Corner of BuildingPad 12" 2L 8.6 107.0 102.0 12.0 104.9% Yes 3 Center of Building Pad 12" 2L 8.7 109.8 102.0 12.0 107.6% Yes 4 SW Corner of Building Pad 12" 3L 9.0 106.1 102.0 12.0 104.0% Yes 5 NW Corner of Building Pad 6 Center of Building Pad SW Corner of Building Pad SE Corner of Building Pad NE Corner of Building Pad Center of BuildingPad SW Corner of BuildingPad 12" 3L 8.9 106.4 102.0 12.0 104.3% Yes 7 12" 12" 12" 3L 3L 4L 3.7 4.9 108.5 105.1 106.4 102.0 102.0 102.0 12.0 12.0 12.0 106.4% 103.0% 104.3% Yes Yes Yes 8 9 10 12" 4L 104.7 102.0 12.0 102.6% Yes 11 12" 4L f87 102.9 102.0 12.0 100.9% Yes 12 ISE Corner of BuildingPad 12" 4L 105.8 102.0 12.0 103.7% Yes 13 NW Corner of Buildin Pad 12" 5L 103.7 102.0 12.0 101.7% Yes 14 Center of BuildingPad 12" 5L 6.5 103.6 102.0 12.0 101.6% Yes Remarks: See Reverse Side (Page 2 of 2) for Additional Information for Disclaimer This is a Compaction Test only on the top 12" of the pad/footing and is not a verification of Soil Bearing Capacity. Legend for Elevation: Submitted b: /�Z PR = Proofroll 1,2,3 = 1st, 2nd, 3rd Lift y SL = Springline FL = Final Lift Keith LeBlanc, P.E. SG = Subgrade BG - Below Grade Federal Engineering & Testing; Inc. BC = Basecourse BOF = Bottom of Footing Florida Reg. No. 59394 TOP = Top of Pipe FG = Finished Grade Certificate cf Authorizaticn #547 , As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for oublication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. A density test determines the degree of compaction of the tested layer of material only. A density does not replace a soil bearing capacity determination. These density tests do not certify the underlying soil materials below the proposed structure. The results do not preclude or guarantee that future settlement and cracking will not occur. A soil boring test is required to certify that the underlying soils will support the proposed structure without settlement. If no soil borings have been performed to verify the underlying soils, we recommend that soil borings be performed tc evaluaha the s,iitabiiity of ti;e underlying soil to support the proposed structure. After laying dormant for a period of 90 days or after heavy rain/storms, retesting must be performed o1, this work. PAGE 1 of 2 0'ederal ngineering ®0esting, Inc. Field Density Tests of Compacted Soils Method D-6938 Project: Proposed Single Family Home Date: Address: 5804 Raintree Trail, Fort Pierce, FL 34982 Order #: Area Tested: Buildinq Pad Permit #: Material Type Dark Brown Sand Company: Groza Builders, Inc. Address: 1332 Biltmore Street Port St. Lucie, FL 34983 Tech: Compaction Req.: Proctor Method: Phone: 954-784-2941 E-Fax: 954-784-7875 admin@fed-eng.com www.fed-eng.com 3370 :.. January 12, 2022 22CMT0131 TS 98% ASTM D-1557 Test # TEST LOCATION Probe Depth Elev. Moist % Dry Density PCF Proctor Value PCF Optimum Moisture % Compaction Pass 15 SE Corner of Building Pad 12" 5L 6.9 103.0 102.0 12.0 101.0% Yes 16 17 18 19 20 21 22 23 24 25 26 27 28 Remarks: See Reverse Side (Page 2 of 2) for Additional Information for Disclaimer This is a Compaction Test only on the top 12" of the pad/footing and is not a verification of Soil Bearing Capacity. Legend for Elevation: PR = Proofroll 1,23 = 1st, 2nd, 3rd Lift Submitted by: SL = Springline FL = Final Lift Keith LeBlanc, P.E. ;/, yi?✓ SG = Subgrade BG = Below Grade Federal Engineering 8. ?esting, Inca BC = Basecourse BOF = Bottom of Footing Florida Reg. No. 59394 TOP = Top of Pipe FG = Finished Grade Certificate of Authorization #5471 As a mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for p.lblica!ion of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. A density test determines the degree of compaciion of the tested layer of material only. A density does not replace a soil bearing capacity determination. These density tests do not certify the underlying soil materials below the proposed structure. The results do not preclude or guarantee that future settlement and cracking will not occur. A soil boring test is required to certify that the underlying soils will sUPD�rt [h propos�d structure without settlement. If no soil borings have been performed to verify the underlying soils, we recommend that soil borings be performed to evaluate the suitability m the underlying soil to support the proposed structure. After laying dormant for a period of 90 days or after heavy rain/storms, retesting must be performed on this work. PAGE 1 of 2