ELECTRICAL PLANS
DWREFD WEWHAHU-1ACCU-1ACCU-2MICRONSITE ELECTRICAL PLANFUTURE POOL BY OTHERSALL EXTERIOR LIGHTS SHALL BEWP/GFI - L.E.D. ON T.C.VERIFY LOCATION AND NUMBEROF LIGHTS WITH ARCHITECTPRIOR TO INSTALLATIONALL OUTDOOR INSTALLATIONS SHALLCOMPLY WITH N.E.C. 110.12, 110.28 & 358.12ALL POOL EQUIPMENT SHALL HAVE GFIPROTECTION AS PER N.E.C. 608.22(B)ALL LANDSCAPE LIGHTS 6' MIN.FROM EDGE OF POOLP-2WP/GFIP-11WP/GFIP-11WP/GFIP9PANEL "P"PROPOSED(2) STORY RESIDENCEELECTRICALSERVICEWELL PUMPP5.7DATE:SHEET#1.NO.5.4.2.3.REVISIONSDATE9/21/2021DRAWN BY: CHECKED BY:©DBTekLLCPhone: (954) 281-2760email: julian@dbtekllc.comCA #33374RN Engineering, Inspection & Construction, Inc.10100 W. Sample Road, Third floor, Coral Springs, FL 33065email: rolando@rneic.comTEL: 772 92 3300NEW RESIDENCE PLAN FOR:Mr. Joseph Scuotto & Mrs. Allison LiottiProperty Address : Vacant LotParcel ID: 3532-503-0008-000-3Saint Lucie CountySE100J.O. R.N.SITE ELECTRICAL PLANAND NOTES. FIRST FLOOR ELECTRICAL PLANDWREFD WEWHAHU-1ACCU-1ACCU-2MICROCSDCMSDCSDNSECOND FLOOR ELECTRICAL PLANAHU-2SDCSDSDSDSDSDNPANEL "P"A9WP/GFIDWA12DISPA14A6GFIMICROA8A2GFIA4GFIB6TO LIGHTSABOVEA3WP/GFIA7PANEL "A"ELECTRICAL KEY NOTES 1TV AND RECEPTACLE LOCATION TO BEVERIFIED BY OWNER.1A11VPGFI1B711B3WP/GFIAHU-1A39,41A/C CU-2B22,24A/C CU-1C5,7A16GFIA17GFIA17GFIA15P2TO POOLLIGHTSPOOLPUMPP1,3IRRIG.PUMPP8,10A5TO LIGHTSABOVEP11TO LANDSCAPE LIGHTS P9TO LANDSCAPE LIGHTS A10A18A20A22,24A19GFITANKLESSA21,23 & A25,27VPVPGFIB2B6TO LIGHTSWITCH B6TO LIGHTSSWITCH B6TO LIGHTSABOVEAHU-2A39,41A2GFIA2GFIA2GFIA2GFIA4GFIA4GFIA4GFIA4GFIA9WP/GFIA9WP/GFIA17GFIA6A15A15A13A13A13A1A1A1A1A1A1A1A1A1A1B7A1A1A1A1A18A18A11A18A11A11A11A11A5TO LIGHTSSWITCH A7A7A9A9A3A3A3B2GFIB4GFIB4B4B4B4B4B4B4B5B5B5B5B7B7B7B7B7B8B8B8B8PANEL "B"RANGEA26,28B8ELECTRICALSERVICEB8B1B1B1B1B1B1B3B3B3B3B3B3B9WP/GFIB9B9B9B9WP/GFIB9WP/GFIAPPLICABLE BUILDING CODESBUILDING CODE: FBC 7th EDITION (2020)ELECTRICAL CODE: NEC (2017)DATE:SHEET#1.NO.5.4.2.3.REVISIONSDATE9/21/2021DRAWN BY: CHECKED BY:©DBTekLLCPhone: (954) 281-2760email: julian@dbtekllc.comCA #33374RN Engineering, Inspection & Construction, Inc.10100 W. Sample Road, Third floor, Coral Springs, FL 33065email: rolando@rneic.comTEL: 772 92 3300NEW RESIDENCE PLAN FOR:Mr. Joseph Scuotto & Mrs. Allison LiottiProperty Address : Vacant LotParcel ID: 3532-503-0008-000-3Saint Lucie CountyE101J.O. R.N.FIRST AND SECOND FLOORELECTRICAL PLANSNOTES AND LEGENDSELECTRICAL LEGEND ATTIC/STORAGEATTIC/STORAGE ELECRICAL PLANNB10GFIA5TO LIGHTSSWITCH SURFACE MOUNTED OR RECESSED (FIXTURE) WITH A COMPLETELY ENCLOSEDLAMP.GENERAL ELECTRICAL NOTES1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE NATIONAL ELECTRICALCODE (N.E.C. 2017), 2020 FBC, 2018 NFPA-101, 2018 NFPA-1, ALL MATERIAL SHALL BENEW AND SHALL BEAR THE U.L. LABEL WHERE APPLICABLE.2. CONTRACTOR SHALL MAKE ALL NECESSARY CUTTING AND DO ALL THE REPATCHINGAS NECESSARY FOR THE PROPER EXECUTION OF THIS WORK.3. AFTER COMPLETION OF THE INSTALLATION, THE SYSTEM SHALL TEST FREE FROMSHORT CIRCUITS AND GROUNDS.4. WHERE ELECTRICAL CONDUCTORS ARE INSTALLED IN CONDUIT, THE CONDUIT SHALLCOMPLY WITH THE N.E.C. REQUIREMENTS.5. ALL CONDUCTORS SHALL BE COPPER. NO CONDUCTOR SHALL BE SMALLER THAN #12AWG AND SHALL BE RATED FOR 600 VOLTS THWN OR THHN INSULATION. INSTALL AGROUNDING CONDUCTOR WITH ALL CIRCUITS, UNLESS NOTED OTHERWISE, SIZED PERN.E.C. 250-122.6. VERIFY BREAKER AND CORRESPONDING WIRE SIZES FOR ALL ELECTRICALEQUIPMENT. DO NOT ORDER MATERIAL BEFORE VERIFYING BREAKER AND WIRE SIZE.REPORT ANY DISCREPANCY IMMEDIATELY TO THE ENGINEER OF RECORD.7. VERIFY AVAILABLE INTERRUPTING CURRENT (AIC) WITH POWER COMPANY. EQUIPMENTAIC RATING MUST BE LARGER THAN THE POWER COMPANY AIC.8. SAFETY SWITCHES SHALL BE SQUARE 'D', GENERAL ELECTRIC, OR WESTINGHOUSE,FUSED OR NON-FUSED AND SIZED AS INDICATED, NEMA 3R WHEN EXPOSED TOWEATHER.9. PANELS SHALL BE SQUARE 'D', GENERAL ELECTRIC OR EQUAL, TYPE AND NUMBER OFBREAKERS AS INDICATED ON PANEL SCHEDULE. STENCIL PANEL DESIGNATION ONINSIDE OF PANEL. ALL TWO-POLE BREAKERS SHALL BE COMMON TRIP. PROVIDE TYPEWRITTEN SCHEDULE IN EACH LOAD CENTER. CONNECTION TO MAIN BUS SHALL BEWITH BURNDY ANNULAR COMPRESSION LUGS.10. ALL EXTERIOR ELECTRICAL EQUIPMENT SHALL BE ANCHORED TO COMPLY WITH LOCALCODE FOR WIND RESISTANCE.11. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OFCONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMSFOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTSNECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER.12. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN AFIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLYOPERATIVE AND ACCEPTED BY THE OWNER.13. LOAD DATA IS BASED ON INFORMATION GIVEN ENGINEER AT TIME OF DESIGN. VERIFYALL EQUIPMENT AND PANEL SIZES BEFORE ORDERING AND BEFORE INSTALLATION.14. ALL ELECTRICAL AND COMMUNICATIONS OUTLETS TO BE AT 15" A.F.F. TO BOTTOM OFOUTLET UNLESS OTHERWISE NOTED, ALL LIGHT SWITCHES SHALL BE @ 42" A.F.F. TOBOTTOM OF SWITCH.15. SERVICE MUST BE 3' ABOVE MSL, VERIFY AT SITE.16. CONTRACTOR MUST VISIT THE SITE PRIOR TO BID OR CONSTRUCTION TO VERIFY ALLEXISTING CONDITIONS.17. WHEN NEW ELECTRIC SERVICE IS BEING INSTALLED, IT IS THE GENERALCONTRACTOR'S RESPONSIBILITY TO COORDINATE WITH FPL/FPL ENGINEERS ON THESIZE OF THE FPL TRANSFORMER THAT IS REQUIRED TO PROVIDE THE NEW ELECTRICSERVICE SHOWN ON ELECTRIC PLANS, GC HAS TO INFORM THE OWNER ABOUT ANYEXTRA FPL CHARGES THAT MIGHT OCCUR IN ORDER TO PULL NEW SERVICE. THIS HASTO BE DONE AS EARLY AS POSSIBLE DURING THE BIDDING PROCESS.405.7.3 VOLTAGE DROP.405.7.3.1 FEEDERS AND CUSTOMER OWNED SERVICE CONDUCTORS.FEEDER AND CUSTOMER OWNED SERVICE CONDUCTORS SHALL BE SIZED FOR AMAXIMUM VOLTAGE DROP OF 2 PERCENT AT DESIGN LOAD.405.7.3.2 BRANCH CIRCUITS. BRANCH CIRCUIT CONDUCTORS SHALL BE SIZED FOR AMAXIMUM VOLTAGE DROP OF 3 PERCENT AT DESIGN LOAD.405.7.4 COMPLETION REQUIREMENTS.405.7.4.1 DRAWINGS. CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT WITHIN 30DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THEACTUAL INSTALLATION SHALL BEPROVIDED TO THE BUILDING OWNER, INCLUDING:1. A SINGLE-LINE DIAGRAM OF THE BUILDING ELECTRICAL DISTRIBUTION SYSTEM AND2. FLOOR PLANS INDICATING LOCATION AND AREA SERVED FOR ALL DISTRIBUTION.405.7.4.2 MANUALS. CONSTRUCTION DOCUMENTS SHALL REQUIRE THAT ANOPERATING MANUAL AND MAINTENANCE MANUAL BE PROVIDED TO THE BUILDINGOWNER. THE MANUALS SHALLINCLUDE, AT A MINIMUM, THE FOLLOWING:1. SUBMITTAL DATA STATING EQUIPMENT RATING AND SELECTED OPTIONS FOR EACHPIECE OF EQUIPMENT REQUIRING MAINTENANCE.2. OPERATION MANUALS AND MAINTENANCE MANUALS FOR EACH PIECE OFEQUIPMENT REQUIRING MAINTENANCE. REQUIRED ROUTINE MAINTENANCE ACTIONSSHALL BE CLEARLY IDENTIFIED.3. NAMES AND ADDRESSES OF AT LEAST ONE QUALIFIED SERVICE AGENCY.NOTE: ENFORCEMENT AGENCIES SHOULD ONLY CHECK TO BESURE THAT THE CONSTRUCTION DOCUMENTS REQUIRE THIS INFORMATION TO BETRANSMITTED TO THE OWNER AND SHOULD NOT EXPECT COPIES OF ANY OF THEMATERIALS.405.3 TANDEM WIRING:LUMINAIRES DESIGNED FOR USE WITH ONE OR THREE LINEAR FLUORESCENT LAMPSGREATER THAN 30 W EACH SHALL BE TANDEM WIRED WHEN TWO OR MORELUMINAIRES ARE IN THE SAME SPACE AND ON THE SAME CONTROL DEVICE.EXCEPTIONS:1. RECESSED LUMINAIRES MORE THAN 10 FEET APART MEASURED CENTER TOCENTER.2. SURFACE-MOUNTED OR PENDANT LUMINAIRES THAT ARE NOT CONTINUOUS.3. LUMINAIRES USING THREE-LAMP HIGH-FREQUENCY ELECTRONIC OR THREE-LAMPELECTROMAGNETIC BALLASTS.4. RECESSED LUMINAIRES MORE THAN 10 FEET APART MEASURED CENTER TOCENTER.5. SURFACE-MOUNTED OR PENDANT LUMINAIRES THAT ARE NOT CONTINUOUS.6. LUMINAIRES USING THREE-LAMP HIGH-FREQUENCY ELECTRONIC OR THREE-LAMPELECTROMAGNETIC BALLASTS.PER FLORIDA BUILDING CODE 2020ENERGY CONSERVATION:BRANCH CIRCUIT VOLTAGE DROPMAXIMUM 3% PER 2020 FBCCIRCUIT LOADWIRE SIZEMAXIMUMLENGTH IN AMPSCOPPERIN FEET5 AMPS OR LESS #12 AWG1806 AMPS #12 AWG1507 AMPS #12 AWG1308 AMPS #12 AWG1159 AMPS #12 AWG10010 AMPS #12 AWG9011 AMPS #12 AWG8312 AMPS #12 AWG7513 AMPS #12 AWG7014 AMPS #12 AWG6515 AMPS #12 AWG6016 AMPS #12 AWG5717 AMPS #12 AWG5418 AMPS #12 AWG5119 AMPS #12 AWG4820 AMPS #12 AWG45 ENERGY CONSERVATION CODESECTION 405.7.3.2NOTES:ALL NEW EXTERIOR RECEPTACLES TO BE RECESSED.PER N.E.C. 2017 406.9ALL NEW RECEPTACLES IN DAMP LOCATIONS INDICATED AS WEATHERPROOF ON PLAN(WP) SHALL HAVE AN ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THEATTACHMENT PLUG CAP IS INSERTED.ALL NEW RECEPTACLES IN WET LOCATIONS INDICATED AS WEATHER-RESISTANT ON PLAN(WR) SHALL HAVE AN ENCLOSURE THAT IS WEATHER-PROOF WHETHER OR NOT THEATTACHMENT PLUG CAP IS INSERTED. NONLOCKING RECEPTACLES SHALL BE LISTEDWEATHER-RESISTANT TYPE.PER N.E.C. 2017 406.12 ALL NEW 120V, 15A AND 20A RECEPTACLES INSTALLED IN ALL AREAS(KITCHEN, FAMILY ROOM, DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN ANDRECREATION ROOM) SHALL BE LISTED TAMPER RESISTANT RECEPTACLES.SECTION 404ELECTRICAL POWER AND LIGHTING SYSTEMS404.1 LIGHTING EQUIPMENT. A MINIMUM OF 50 PERCENT OF THE LAMPS IN PERMANENTLYINSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.PER FLORIDA BUILDING CODE 2020 ENERGYCONSERVATION:THESE NOTES TAKE PRECEDENCE IF THERE IS ANY DISCREPANCY WITH THE PLANS.ALL BATHROOMS, GARAGES, EXTERIOR RECEPTACLES, KITCHEN APPLIANCECIRCUITS, DINING ROOM RECEPTACLES, AND BREAKFAST ROOM TO BE ON 20 AMPBREAKERS.ALL 110V RECEPTACLES IN BATHROOMS, GARAGES, EXTERIOR RECEPTACLES,KITCHEN RECEPTACLES (EXCEPT FRIDGE, DISHWASHER AND DISPOSAL), SHALLHAVE GROUND FAULT CURRENT INTERRUPTER (GFCI) PROTECTION.ALL EXTERIOR RECEPTACLES TO BE WEATHER PROOF.ALL 15 AMP AND 20 AMP 120V ELECTRICAL CIRCUITS, EXCEPT GFCI RECEPTACLES,SHALL HAVE ARC FAULT CURRENT INTERRUPTER BREAKERS. (RECEPTACLES,LIGHTS, SWITCHES, FANS, SMOKE DETECTORS)SMOKE DETECTORS TO BE HARD WIRED 110V WITH BATTERY BACKUP AND ONKITCHEN OR BATHROOM LIGHTING CIRCUITS, INTERCONNECTED AHEAD OFSWITCHES. ALL SMOKE DETECTORS SHALL BE MOUNTED AT THE HIGHEST POINT OFTHE CEILING PER ROOM.DO NOT MOUNT SMOKE DETECTORS WITHIN 3 FEET OF BATHROOM DOOR OR HVACDIFFUSERS OR TIP OF FAN BLADE.ALL RECEPTACLES TO BE TAMPER RESISTANT PER NEC 2008 406.11.SMOKE DETECTORS WITHIN 20FT HORIZONTAL PATH OF COOKING APPLIANCESSHALL BE EQUIPPED WITH ALARM SILENCING MEANS OR BE PHOTOELECTRIC TYPE.MORE THAN 12 INTERCONNECTED SMOKE DETECTORS ARE REQUIRED TO BESUPERVISED (ALARM COMPANY MUST BE CONTRACTED FOR MONITORING).ESSENTIAL SWITCHES AND CONTROLS TO BE LOCATED BETWEEN 42" AND 52" FROMTHE FLOOR AS PER THE STATE ACCESSIBILITY CODE.ALL RECEPTACLES TO BE @ 15" A.F.F. TO BOTTOM OF RECEPTACLE UNLESS NOTEDOTHERWISE OR ABOVE COUNTER.ELECTRICAL CODE NOTES:B10DATE:SHEET#1.NO.5.4.2.3.REVISIONSDATE9/21/2021DRAWN BY: CHECKED BY:©DBTekLLCPhone: (954) 281-2760email: julian@dbtekllc.comCA #33374RN Engineering, Inspection & Construction, Inc.10100 W. Sample Road, Third floor, Coral Springs, FL 33065email: rolando@rneic.comTEL: 772 92 3300NEW RESIDENCE PLAN FOR:Mr. Joseph Scuotto & Mrs. Allison LiottiProperty Address : Vacant LotParcel ID: 3532-503-0008-000-3Saint Lucie CountyE102J.O. R.N.ATTIC/STORAGEELECRICAL PLANNOTES AND LEGENDSELECTRICAL LEGEND TOTAL LOAD CALCULATION - (MDP)FIRST 10.0 KW @100%AC @100%NEXT (62.1 KW) @ 40%15.2 KW10.0 KW24.8 KW50.0 KW = 208.0 AMPSWIRE9117CB TRIPPOLECKT BREAKERNoCKT153PANEL:DESCRIPTIONkW"MDP"250 AMPSMB1012FLUSH120/240 1Ø 3W22,000 A.I.C.TRIP8CKTNoCKT BREAKERPOLE CB246VOLTAGE:AIC:MOUNTING:kWMAINS:BUS:POLES: 16TOTAL CONNECTED87.3SEE RISER150FAE2 PANEL "A"56.6WIRELOADDESCRIPTIONLOADWIRE2123199131517117CB TRIPPOLECKT BREAKERNoCKT153PANEL:LOAD DESCRIPTIONkW"P"100 AMPSMB24201018161412FLUSH120/240 1Ø 3W22,000 A.I.C.TRIPNOTESCOND.SIZE8CKTNoCKT BREAKERPOLE CB246VOLTAGE:AIC:MOUNTING:LOAD DESCRIPTIONkWMAINS:BUS:POLES: 24NOTESSIZECOND.WIRE20TQL2 POOL PUMP3.61ARC- FAULT INTERRUPTERTAMPER RESISTANCE(SEE NEC 2014 406.12, FOR TAMPER RESISTANT RECEPTACLE REQUIREMENTS).TOTAL CONNECTED12.93#12 THHN22 LOAD CALCULATIONS12.9 KW = 53.6 AMPS3/4"POOL LIGHTS120TQL3#12 THHN 1/2"0.5VERIFYVERIFYALL POOL EQUIPMENT SHALL HAVE GFI PROTECTION AS PER N.E.C. 608.22(B)1. PER THE NEC SECTION 210.12(B): ALL 120V, SINGLE PHASE, 15- AND 20-AMPERE BRANCHCIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DININGROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS,RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS, SHALL BEPROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMPNATION-TYPE,INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT.ALL 120V, SINGLE PHASE, 15- AND 20-AMPERE RECEPTACLES IN AREAS SPECIFIED ABOVESHALL BE TAMPER RESISTANT.2. ALL SMOKE/CARBON MONOXIDE DETECTORS TO HAVE BATTERY BACK UP AND SIGNALSIMULTANEOUSLY W/ TEMPORAL SOUND. SMOKE/CARBON MONOXIDE DETECTORS TO BELOCATED MIN 3'-0" FROM: R/A & SUPPLY GRILLS, KITCHENS, BATH ROOMS.3. ALL LIGHTING FIXTURES AND FANS TO BE SELECTED BY OWNER /ARCHITECT, UNLESSOTHERWISE NOTED.4. ARCHITECT TO SET MOUNTING HEIGHTS FOR ALL FIXTURES WHERE APPLICABLE, UNLESSOTHERWISE NOTED.5. ALL DIMMER SWITCHES TO BE LUTRON SLIDE BAR WITH PRESET 1 KW MINIMUM.6. FOR FLOOR RECEPTACLES, PROVIDE A BRASS COVER PLATE AND FLUSH WITH FLOOR.VERIFY EXACT LOCATION WITH GC/OWNER. PROVIDE 1/2"C UNDERSLAB FROM WALL.7. ROMEX MAY BE USED WHERE CONDUIT IS NOT REQUIRED. ALL BRANCH CIRCUITS LISTEDIN PANEL SCHEDULED WITH A CONDUIT SIZE INDICATED IS TO BE RUN IN CONDUIT. IFCONDUIT IS NOT UTILIZED, CONTRACTOR SHALL ENSURE SIZING OF ROMEX IS PER NECARTICLE 334.8. BX CABLE MAY BE USED IN LIEU OF RIGID CONDUIT.9. PROVIDE GREEN WIRE GROUND TO ALL EXTERIOR FIXTURES AND "J" BOXES.10. ELEVATOR SHALL MEET NEC 620 22-23; VERIFY LOCATION AND ELECTRICALREQUIREMENTS OF ELEVATOR EQUIPMENT WITH MFG SPECS PRIOR TO CONSTRUCTION.11. IF THERE IS AN ELEVATOR PIT LOCATED BELOW, PROVIDE WITH FLOAT SWITCH SENSOR;LIGHT FIXTURE SHALL NOT BE INSTALLED IN ELEVATOR PIT.12. VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL AHU's AND CU'sWITH MECHANICAL CONTRACTOR PRIOR TO BID AND CONSTRUCTION.13. PROVIDE A LIGHTING FIXTURE WITH RECEPTACLE OUTLET AT ATTIC ACCESS,CONTROLLED BY A SWITCH LOCATED AT THE PASSAGEWAY OPENING PER FMC 306.3.1.14. VERIFY EXACT LOCATIONS OF ALL KITCHEN EQUIPMENT WITH OWNER/ARCHITECTPRIOR TO CONSTRUCTION. - VERIFY ALL ELECTRICAL REQUIREMENTS OF ALL EQUIPMENTWITH MFG SPECS PRIOR TO CONSTRUCTION.15. LIGHTING IN CLOTHES CLOSETS MUST COMPLY WITH N.E.C. 410.16/A/B/C.16. NOT USED.17. AV POWER BY OTHERS. ELECTRICAL CONTRACTOR TO OBTAIN ALL LOADS PRIOR TOINSTALLATION.18. DRAPERY/WINDOW SHADE POWER LOCATED BY HOME OWNERS; VERIFY MOUNTING &ELECTRICAL REQUIREMENTS WITH MFG SPECS.19. VERIFY MOUNTING HEIGHT AND LOCATION OF TV OUTLET AND RECEPTACLE WITHOWNER/INTERIOR DESIGNER PRIOR TO CONSTRUCTION. THE RECEPTACLE SHALL NOT BELOCATED HIGHER THAN 5'-6" A.F.F., OTHERWISE AN ADDITIONAL RECEPTACLE MAY BEREQUIRED AT A MAXIMUM HEIGHT OF 5'-6" A.F.F. TO COMPLY WITH NEC SECTION 210.52.ELECTRICAL NOTES1203#12 THHN 3/4"TQLWIRE21252723199131517117CB TRIPPOLECKT BREAKERNoCKT153PANEL:LOAD DESCRIPTIONkW"A"150 AMPSMLO282624201018161412FLUSH120/240 1Ø 3W22,000 A.I.C.TRIPNOTESCOND.SIZE8CKTNoCKT BREAKERPOLE CB246VOLTAGE:AIC:MOUNTING:LOAD DESCRIPTIONkWMAINS:BUS:POLES: 40NOTESSIZECOND.WIRE2930TQL1TQL1TQL1LOAD CALCULATIONAPPROXIMATELY 1,245 SQ. FT. x 3 WATTS = 3,735 WATTS1ARC- FAULT INTERRUPTERTAMPER RESISTANCE(SEE NEC 2014 406.12, FOR TAMPER RESISTANT RECEPTACLE REQUIREMENTS).TOTAL CONNECTED56.622TQL11.52#12 THHN20SMALL APPLIANCESTQL11.520TQL11.520TQL120TQL11.120TQL13.72#14 THHN15TQL1(.)2#14 THHN15(.)2#14 THHN15(.)2#14 THHN15(.)2#14 THHN15TQL10.62#12 THHNSMALL APPLIANCES2#12 THHNSMALL APPLIANCES2#12 THHN2#12 THHNREFRIGERATOR1111111112WITH GFI BREAKER11.22#12 THHN20TQL11.2202#12 THHNDISHWASHERTQL10.8202#12 THHNDISPOSAL111TQL1152#14 THHN122220TQL2 WELL PUMP3.03#12 THHN3/4"OFFICE LIGHTS & RECEPTACLESCOVERED PATIO LTS & RECEPT'SFOYER LIGHTS & RECEPTACLESEXTERIOR LIGHTS & RECEPT'SGARAGE RECEPTACLESTQL1(.)202#12 THHNBATH-1 LTS & RECEPT'S1GARAGE DOORLANDSCAPE LIGHTS - BACK1.0PH FEEDER0.11 20TQL2#12 THHN 1/2"13151416100TQL2 PANEL "P"12.9SEE RISER1 203#12 THHN 3/4"TQL 1.0ELECTRICAL RISERNTSCOORDINATE ALL WORK WITH FPLALL ELECTRICAL EQUIPMENT SHALL BE RATED @ 22,000 AIC, UNLESS NOTED.ALL ELECTRICAL EQUIPMENT 3'-0" ABOVE MSL.ALL SERVICE DISCONNECTS SHALL BE LABELED.THE ELECTRICAL INSTALLATION SHALL MEET ALLSTANDARD REQUIREMENTS OF POWER COMPANY.1.)2.)ELECTRICAL SYSTEM SHALL BE COMPLETED, ANDEFFECTIVELY GROUNDED, AS REQUIRED BY THEN.E.C. AND 2014 F.B.C.ELECTRICAL RISER NOTES:3.)ALL ELECTRICAL EQUIPMENT SHALL BE LABELEDTO INDICATED POTENTIAL ELECTRIC ARC-FLASHHAZARDS- AS PER NEC 110.16 ()4.)ALL ELECTRICAL EXTERIOR EQUIPMENT SHALL BENEMA 3R RATED5.)SERIES COMBINATION SYSTEM OR A TESTEDSERIES COMBINATION SYSTEM. NEC -110 (A-C)ALL EQUIPMENT WILL MEET FAULT CURRENTRATINGS PER NEC - 110.9 . CALCULATED FROMFP&L TRANSFORMERS PROJECTIONS6.)NO ELECTRICAL EQUIPMENT OR ELECTRICALOUTLETS SHALL BE LOCATED BELOW DESIGNFLOOD ELEVATION (BASE FLOOR ELEVATION +1')AS PER CITY OF FT. LAUDERDALE ORDINANCEARTICLE II SECTION 14-10 AND 14-17120/240-1Ø-3WFPL MANHOLEVERIFY LOCATION2-2502-125M.D.P.SPACE2-502-150SPACEPANEL "P"100 A. MB120/240V/1Ø/3WPANEL "A"150A MLO120/240V/1Ø/3WPANEL "B"125A MLO120/240V/1Ø/3W2-100RUNS OF (3)#350THWN - 2-1/2"#2 GR.1" C.REINFORCEMENT OFCONCRETE FOOTING8'(2) GROUND RODSGROUNDING TERMINALCOLDWATER PIPE (CU)INTERIORGARAGEEXTERIOREXTERIOR(3)#3 THWN(1)#6 GR. -1-1/4"(3)1/0 THWN(1)#6 GR.- 2"STAIR LIGHTSLIVING LTS & RECEPT'STQL1(.)2#14 THHN15KITCHEN LIGHTSTQL1(.)2#14 THHN15GARAGE/LAUNDRY LIGHTSMICROWAVE(.)11LOW VOLTAGEGROUNDINGTERMINALTQL10.5201A/C CU-1TQL212.03#6 THHN50TANKLESS STAGE-1HACR2 4.8302#12 THHNHACR2 1.23#12 THWN20 AHU-1TQL11.52#12 THHN20LAUNDRY ROOM RECEPTACLE1TQL11.52#12 THHN20WASHING MACHINETQL25.03#10 THHN30DRYERWIRE2123199131517117CB TRIPPOLECKT BREAKERNoCKT153PANEL:LOAD DESCRIPTIONkW"B"125 AMPSMLO24201018161412FLUSH120/240 1Ø 3W22,000 A.I.C.TRIPNOTESCOND.SIZE8CKTNoCKT BREAKERPOLE CB246VOLTAGE:AIC:MOUNTING:LOAD DESCRIPTIONkWMAINS:BUS:POLES: 24NOTESSIZECOND.WIRETQL1TQL1LOAD CALCULATIONAPPROXIMATELY 961 SQ. FT. x 3 WATTS = 2,883 WATTS1ARC- FAULT INTERRUPTERTAMPER RESISTANCE(SEE NEC 2014 406.12, FOR TAMPER RESISTANT RECEPTACLE REQUIREMENTS).TOTAL CONNECTED10.022TQL1(.)2#12 THHN20BATH-2 LIGHTS & RECEPTACLESTQL1(.)20TQL13.02#14 THHN15TQL1(.)2#14 THHN15(.)2#14 THHN15(.)2#14 THHN152#12 THHNM-BATH LIGHTS & RECEPTACLES1111112WITH GFI BREAKERTQL1(.)152#14 THHN1BEDROOM-1 LIGHTS & RECEPT'SBEDROOM-2 LIGHTS & RECEPT'SM-BEDROOM LIGHTS & RECEPT'STQL1(.)2#14 THHN15EXTERIOR LIGHTS & RECEPT'SHALL LIGHTS & RECEPTACLES1A/C CU-2HACR25.235HACR2 1.23#6 THWN20 AHU-2M-BEDROOM LIGHTS & RECEPT'S3#10 THHN3#10 THHN(3)#1THWN(1)#6 GR.- 1-1/2"SEE RISER125FAE2 PANEL "B"10.0LANDSCAPE LIGHTS - FRONTVERIFYPH FEEDER0.11 20TQL2#12 THHN 1/2"20TQL2 IRRIG. PUMP3.63#12 THHN3/4" VERIFY1TQL10.6202#12 THHNATTIC/STORAGE LTS & RECEPT'S12#14 THHNTQL1(.)15DINING ROOM LIGHTS129292929292929292929HACR210.03#6 THWN50RANGETQL212.03#6 THHN50TANKLESS STAGE-2 LOAD CALCULATIONS10.0 KW = 41.6 AMPS2RUNS OF (3)#350THWN - 2-1/2" LOAD CALCULATIONSFIRST 10.0 KW @ 100%10.0 KW32.2 KW = 134.1 AMPSNEXT 40.6 KW @ 40%16.2 KWAC @ 100%6.0 KWDATE:SHEET#1.NO.5.4.2.3.REVISIONSDATE9/21/2021DRAWN BY: CHECKED BY:©DBTekLLCPhone: (954) 281-2760email: julian@dbtekllc.comCA #33374RN Engineering, Inspection & Construction, Inc.10100 W. Sample Road, Third floor, Coral Springs, FL 33065email: rolando@rneic.comTEL: 772 92 3300NEW RESIDENCE PLAN FOR:Mr. Joseph Scuotto & Mrs. Allison LiottiProperty Address : Vacant LotParcel ID: 3532-503-0008-000-3Saint Lucie CountyE501J.O. R.N.ELECTRICAL RISER DIAGRAM,PANEL SCHEDULE, NOTES, AND LEGENDS.