Loading...
HomeMy WebLinkAboutMECHANICAL PLANSSECOND FLOOR HVAC PLAN SCALE: 1 /4" = 1'-0" HVAC LEGEND RIGID SUPPLY AIR DUCTWORK RIGID RETURN AIR DUCTWORK CLASS 1 FLEXIBLE DUCT EXHAUST FAN MOTORIZED DAMPER REFRIGERANT LINE LINEAR CEILING DIFFUSER WITH O.B.D. (TYPICAL) ®SUPPLY AIR GRILL W/O.B.D. ® RETURN AIR GRILLE ® I 3 WAY CEILING DIFFUSER W/O.B.D. ®� 1 WAY CEILING DIFFUSER W/O.B.D. MANUAL VOLUME DAMPER ® SMOKE DETECTOR O PROGRAMMABLE T-STAT TS T-STAT SENSOR MECHANICAL KEY NOTES ONEW BATH EXHAUST - 4"0 METAL DUCT TO WALL CAP WITH BIRD SCREEN. - DUCT SHALL BE INSTALLED AS PER FBCM- 501.3 / 501 .3.1 O4"0 DRYER EXHAUST TO WALL CAP. EXHAUST DUCT SHALL BE METAL /26 GAUGE - DUCT SHALL BE INSTALLED AS PER FBC - 504.6.2 OKITCHEN HOOD FAN ZLINE: KL3CRN-30 - 400 CFM -6"0 SHEET METAL DUCTWORK TO WALL CAP WITH RAIN CAP - HOOD SHALL BE INSTALLED AS PER MANUFACTURER RECOMMENDATIONS - (OR APPROVED. EQUIVALENT) ® NEW BATH EXHAUST - 4"0 METAL DUCT TO ROOF CAP WITH BIRD SCREEN. - DUCT SHALL BE INSTALLED AS PER FBCM- 501.3 / 501 .3.1 OCOORDINATE TRUSS SHOP DRAWINGS WITH DUCT LAYOUT, PARTICULARLY IN AREAS WITH LARGER FLEX DUCTS OR WHERE CROSSING TRUSSES OR GIRDERS. NOTIFY ENGINEER OF ANY CONFLICTS PRIOR TO PROCEEDING. II CONTRACTOR NOTES: II 1 . ALL FLEXIBLE DUCTS SHALL BE PROPERLY SUPPORTED AND PROVIDED A MINIMUM OF 1" SEPARATION OF DUCTWORK AND CEILING SPACE INSULATION. AT NO LOCATION SHALL DUCTWORK COME IN CONTACT WITH CEILING SPACE INSULATION. 2. ALL CRACKS AND OPENINGS AROUND DIFFUSERS SHALL BE SEALED TO PREVENT CONDENSATION. 3. THE CONTRACTOR SHALL BEAR FULL RESPONSIBILITY AND RELATED AND RELATED COSTS INCLUDING FEES FOR ANY FIELD CHANGES OR DEVIATIONS FROM CONSTRUCTION DOCUMENTS WITHOUT WRITTEN AUTHORIZATION FROM THE ARCHITECT OR ENGINEER OF RECORD. 4. GENERAL CONTRACTOR TO SUBMIT PRODUCT DATA SHEETS OF ALL GRILLES, DIFFUSERS, ETC. FOR ARCHITECT'S APPROVAL. 5. ALL DUCTWORK SHALL BE INSTALLED AS PER FBC-M1 601.4.3. DUCTS SHALL BE IN ACCORDANCE WITH MANUFACTURE'S INSTALLATION INSTRUCTIONS. 6. ALL DUCTWORK SHALL BE INSTALLED AND SUPPORTED AT INTERVALS NOT TO EXCEED 12' AND SHALL BE IN ACCORDANCE WITH MAGMA HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE AND OTHER FACTORY MADE DUCTS SHALL BE SUPPORTED IN ACCORDANCE WITH THE MANUFACTURES INSTRUCTION. 7. ALL DUCTWORK SHALL BE INSTALLED AND SUPPORTED IN ACCORDANCE WITH MANUFACTURE'S INSTRUCTIONS. INSTALLATION INSTRUCTIONS SHALL BE ON SITE AT ROUGH INSPECTION. DUCTWORK DESIGN CRITERIA ALL DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF SECTION M1601 OF THE FLORIDA BUILDING CODE. -DESIGNED WITH ACTUATOR BASED ON STANDARD AIR 0.075 POUNDS PER CUBIC FOOT AND DERIVED FROM ASHRAE HANDBOOK OF FUNDAMENTALS. SUPPLY AIR: RETURN AIR: .08 FRICTION PER .05 FRICTION PER 100 FEET OF SUPPLY DUCT 100 FEET OF RETURN DUCT FLEXDUCT: .04 FRICTION PER 100 FEET MAX LENGTH 10'-0" THEN GO TO NEXT LARGER SIZE MAINTAINED BETWEEN 500 TO 800 FPM (FEET PER MINUTE). A/C COMPRESSOR NOTES: 1.REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING T' TAMPER RESISTANT CAPS OR SHALL BE OTHERWISE SECURED TO PREVENT UNAUTHORIZED ACC 2. OUTSIDE MOUNTED EQUIPMENT & SUPPORTS SHALL BE INSTALLED TO RESIST WIND PRESSURE AT VELOCITIES OF INDICATED ON FBC 1620. FBC M-301 .15. 3. THE AC COMPRESSOR SHALL BE ATTACHED TO THE CONCRETE SLAB WITH AN ANCHOR BOLT WITH A MINIMUM OF 500 LBS PULL-OUT RESISTANCE TO SECURE THE CONDENSER UNIT FORM WITHIN THE UNIT THROUGH THE CONCRETE SLAB. CHAPTER 8C SECTION 8C-5 MIAMI DADE COUNTY ORDINANCE. 4. REFRIGERANT LINES INSULATION ON SUCTION LINE SHALL BE A MINIMUM OF 1/2" HAVING THERMAL RESISTIVITY OF AT LEAST R-4 AND HAVING EXTERNAL SURFACE PERMEANCE NOT EXCE 0.05 PERM WHEN TESTED IN ACCORDANCE WITH ASTME 96, FBC R-M1411 .6. vvvn i �.� i ivivo i u� r�nrvnroiw o i r. .,(vr.uriw COMPANY.TESTING SHALL BE PERFORMED AT ANY TIME AFTER CREATION OF ALL PENETRATIONS OF THE BUILDING THERMAL ENVELOPE. FIRST FLOOR HVAC PLAN SCALE: 1 /4" = 1'-0" w Q 0 U) z O Cn w of 1 � I�INIMI I�I�1 D BTEK LLC CIVIL - MEP Phone: (954) 281-2760 email: julian@dbtekllc.com CA #33374 U LO o co co Q J � � c � n ih U) E O O otS U .� o J* N CO C 1-7E co O O @ N �+ O U -a ti N C:M �!E ~ w CU Oj w- E: C am CD NCuE C U) O7 � C C)W o Z o J O C: LL OW c I z Q Q J CD J W 4-0' L CD Lu M CD U 06 M z o> }, • O >N w -1-0"' O cn � i 0 U M O U) wM U w Q Q • • °) Cn J 3 U �_ w i O (a (a z 2 0- U) Digitally signed by Rolando No.60494 *�= Nigaglioni ;.p'. STATE OF �; Date: -0FZORIDP 2021-09-28 20:21-04:00 This Item has been digitally signed and sealed by Rolando Nigaglioni, P.E. on the date aaWent to !ne seal.. ; ,nted copies of this document are not considered signed and sealed and the signature must be verified an any electronic copies. ROLANDO NIGAGLIONI, P.E. z d m 0 w Y U w U ENGINEER OF RECORD FLORIDA LIC.# 60494 L.f_ O O LL `s co Oz0z zQw O� w w J J 0 0Z Q = w O� w p L 2i z SHEET# M 10 1 AIR CONDITIONING NOTES Oj DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS FOR THE EXACT LOCATION OF EQUIPMENT. PIPING, DUCTWORK, ETC. O THESE DRAWINGS ARE NOT INTENDED TO SHOW EVERY MINOR DETAIL, BUT THE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE ACCEPTABLE WORKING INSTALLATION. O ALL WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY THE ARCHITECT AND / OR ENGINEER MUST BE CONDITION OF THE CONTRACT. ® CONTRACTOR WILL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTS. O THE CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE WITH EXISTING CONDITIONS. © PRIOR TO INSTALLING EQUIPMENT AND/OR FABRICATING DUCTWORK, A.C. CONTRACTOR SHALL CHECK THAT THERE IS SUFFICIENT CLEARANCES FOR EQUIPMENT, DUCTWORK, ETC. AND ALSO TO AVOID ANY INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. O7 ALL REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OD THE WORK. ® ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE NATIONAL, STATE, AND LOCAL CODES, RULES, AND ORDINANCES. Og ALL DUCTWORK SHALL CONFORM TO SMACNA STANDARDS. ALL DUCTWORK SIZES ARE INSIDE DIMENSIONS. ALL EXTERIOR DUCTWORK SHALL BE GALVANIZED SHEETMETAL. ALL INTERIOR DUCTWORK SHALL BE FIBERGLASS BOARD UNLESS OTHERWISE NOTED AND CONFORM WITH ALL LOCAL CODES. 10 CONDENSATE DRAINS SHALL BE TYPE "L" COPPER AND INSULATED WITH SEAMLESS CLOSED CELL ARMAFLEX OR EQUAL, AND SHALL BE SIZED AS INDICATED ON THE DRAWINGS. 11 AIR DISTRIBUTION ACCESSORIES SHALL BE AIR GUIDE, ANEMOSTAT, TITUS, OR APPROVED EQUAL. 12 THE ENTIRE INSULATION SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES, INCLUDING ALL LOCAL RULES AND ORDINANCES. 13 14 THE CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD NOT LESS THAN 1 YEAR FROM THE DATE OF ACCEPTANCE, UNLESS OTHERWISE NOTED. 15 CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENTS OR REPAIRS OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED OR IS NOT OPERATING PROPERLY. 16 ARCHITECTURAL AND/OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO REVISIONS FOR SUBSTITUTIONS BY THE CONTRACTOR SHALL BE PAID FOR BY THE CONTRACTOR. 17 CONTRACTOR SHALL TEST AND BALANCE SYSTEM, AND SEND REPORT TO ARCHITECT AND/OR ENGINEER. TEST AND BALANCE CONTRACTOR SHALL BE A MEMBER OF AABC OR NEBB. UNLESS OTHERWISE NOTED. 18 INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN THE LATEST ASHRAE GUIDE. 19 ALL MATERIALS SHALL BE NEW AND SHALL BEAR UNDERWRITER'S LABEL WHERE APPLICABLE. Q IF THERE ARE ANY CHANGES IN ENGINEER'S DRAWINGS, IN DESIGN OR IN EQUIPMENT, WITHOUT ENGINEER'S CONSENT, THE A.C. CONTRACTOR SHALL ASSUME ALL RESPONSIBILITIES FOR THE PROJECT. 21 NO SUBSTITUTION WILL BE CONSIDERED PRIOR TO BID UNLESS WRITTEN REQUEST FOR APPROVAL HAS BEEN RECEIVED BY THE ARCHITECT OR ENGINEER AT LEAST 10 DAYS PRIOR TO THE DATE OF BID. SUCH REQUEST SHALL INCLUDE THE NAME OF EQUIPMENT OR MATERIAL FOR WHICH IT IS TO BE SUBSTITUTED. © MATERIALS A. AIR CONDITIONING RIGID DUCTWORK SHALL BE CONSTRUCTED OF STANDARD DUTY FIBERGLASS BOARD FLAMEPROOF REINFORCED ALUMINUM FACED COVER IN ACCORDANCE WITH S.M.A.C.N.A. AS MANUFACTURED BY Owens-Corning. DUCTWORK SHALL BE FABRICATED AND INSTALLED ACCORDING WITH MANUFACTURER'S INSTRUCTIONS. INSTALL AIR VOLUME EXTRACTORS AT EACH DUCT TAP. DUCTWORK IN ATTIC SPACE (UNCONDITIONED AIR SPACE) SHALL BE OF R=6.0 MINIMUM. DUCTWORK BETWEEN CONDITIONED FLOORS AND ABOVE GARAGES SHALL BE OF R=4.1 MINIMUM. B. FLEXIBLE DUCTWORK SHALL BE CLASS I AIR DUCT, U.L. LISTED AS MANUFACTURED BY ATCO FLEXAIRE OR APPROVED EQUAL AND OF R=4.2. INSTALL PER LATEST S.M.A.C.N.A. STANDARDS AND MANUFACTURER'S RECOMMENDATIONS. DUCTWORK SHALL NOT BE COMPRESSED TO OVER 20% OF ITS CROSS SECTIONAL AREA. DUCTWORK IN ATTIC SPACE (UNCONDITIONED AIR SPACE) SHALL BE OF R=6.0 MINIMUM. DUCTWORK BETWEEN CONDITIONED FLOORS AND ABOVE GARAGES SHALL BE OF R=4.2 MINIMUM. C. TOILET EXHAUST DUCTWORK SHALL BE OF SPUN ALUMINUM THERMOFIN DUCT INSTALLED IN ACCORDANCE WITH ASHRAE AND MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS, D. ALL AIR DEVICES SHALL BE OF ALUMINUM CONSTRUCTION, TITUS, © REFRIGERANT PIPING SHALL BE COPPER TYPE "ACR" WITH WROUGHT COPPER SOLDER JOINT FITTINGS. SILVER SOLDER ALL JOINTS. LINES TO BE RUN IN CLOSED CELL, SEAMLESS INSULATION THAT COMPLIES WITH ASTM C 534, TYPE I FOR TUBULAR METAL.. © MEP EQUIPMENT SHALL BE LOCATED ABOVE THE BASE FLOOD ELEVATION +1 FOOT, EXCEPT AS REQUIRED TO ADDRESS LIFE SAFETY REQUIREMENTS. 2" MINIMUM ALL SIDES CONDENSING UNIT. SEE SCHEDULE FOR MANUFACTURER, PART NO., ETC. 4" CONCRETE PAD NON -INSULATED LIQUID LINE SUCTION LINE WITH 1/2" ARMAFLEX INSULATION AND BARRIER 1/4" DIAMETER TEK SCREWS 1-3/4" TAPCON SCREW TO PAD NOTES: THE CONDENSING UNIT TO BE FASTENED TO THE PAD WITH 8 GALVANIZED ANGLE BRACKETS, 2 BRACKETS PER SIDE, USING NO LESS THAN ONE 1-3/4" LONG TAPCON SCREW TO PAD, AND TWO 1/4" TEK SCREWS TO A/C CU PER BRACKET. SCREWS AND ANCHORS TYPICAL FOR ALL FOUR SIDES OF CONDENSING UNIT. THIS INSTALLATION MEETS FBC 2020. CORROSION PROTECTION: BUILDINGS LOCATED WITHIN 3,000 FEET OF THE OCEAN SHOULD UTILIZE NONFERROUS METAL, STAINLESS STEEL, OR STEEL WITH MINIMUM G-90 HOT -DIP GALVANIZED COATING FOR EQUIPMENT STANDS AND ANCHORS AND STAINLESS STEEL SCREWS. CONDENSING UNIT MOUNTING DETAIL rV44 kv7m4i ORP NTS 960 ALabama Avenue - Brooklyn, NY 11207 - (718) 927-0009 - Fax: (718) 485-4403 - www.caMbridgeresources,coM INSTRUCTIONS FOR HVAC SUPPORT WEBBING INSTALLATION (FOR USE WITH CAMBRIDGE RESOURCES PART NUMBERS PS- 134B AND PS- 134S) • Attach webbing to support beamat a maximum of 4' intervals. There should be no more than 0.5" of sag per foot in the flex duct between the two points where it is hung. • A minimum of 3 feet of webbing should be used at each installation interval. • Fold over 1" ends of webbing before attaching to fixture for maximum sustainability. • Attach webbing to fixture using one of the following: o Standard dry wall screw o 3/4" Roofing nail o Standard #8 nail o Standard'/z"(12mm ) staple - using staple gun or hammer tackler. • For extra strength wrap webbing around beam or fixture twice. • Product is rated to provide an average of 440 lbs. tensile strength. • This product is classified under UL code 2043 for heat release rate and smoke optical density (file R25520) TYPICAL V ISOLATOR (RUBBER( EXHAUSTI HANGING BRACKET A I I /Aurl r/Aiv TO TRUSSES WITH 1 /4" 0 x 2 WOOD CEILING EXHAUST FAN ATTACHMENT HEET METAL EXHAUST DUCT (SEE PLANS. OR SIZE) LEXIBLE DUCT CONNECTION YPICAL CEILING CABINET EXHAUST FAN VITH BACKDRAFT DAMPER, LOW NOISE EVEL AND NO VIBRATION. RONT FACE GRILLE WITH FASTENING SCREENS BATHROOM EXHAUST DUCT SHALL BE THERMORN TO SHEET METAL ROOFJACK WITH BACKDRAFT DAMPER, VENT THRU ROOF 6" ABOVE ROOF SURFACE WITH GOOSE NECK TERMINATION AND WITH CORROSION RESISTANT SCREEN MESH WITH 1/2" MAXIMUM MESH OPENING. DRYER AND KITCHEN HOOD EXHAUST DUCTS TO BE 26 GA SHEET METAL PIPE TO ROOFJACK AS DESCRIBED ABOVE ROOFING NOTE: ROOFING CONTRACTOR TO INSTALL ROOFING MEMBRANE, METAL FLASHING AND ROOFING CEMENT AROUND ALL ROOF PENETRATION TYPICAL. EXHAUST ROOF CAP DETAIL NTS AIR HANDLING UNITS DETAILS GALV. EXHAUST ROOF CAP BIRD SCREEN (EXCEPT ON DRYER VENT) ROOF TILE, FLAT ROOF, OR ASPHALT SHINGLE (26 GA) SMOOTH MTL. DUCT FROM HOOD EXHAUST OR DRYER OR 4" THERMOFIN DUCT FROM BATHROOM EXHAUST FANS RANT DENSATE IN WITH DONDARY NDENSATE NN WITH )AT SWITCH 2' X 1/4" 1MINUM �ME DPRENE PAD RATION LATORS RANT DENSATE IN WITH ,'ONDARY NDENSATE NN WITH )AT SWITCH 2' X 1/4" 1MINUM kME DPRENE PAD RATION LATORS NTS WALL CAP DETAIL NTS RIGID SHEET METAL SLEEVE DUCTWORK T iRU WALL. NO FLEXIBLE DUCT .LOWED. SEAL OR CAULK WATERTIG APPER METAL ROUND FITTING QUADRANT W/ OUTSIDE OPERATION. PROVIDE INSULATION GUARD WHERE NECESSARY DIFFUSER HANGER STRAPS: 1 " x 22" GAUGE, SUPPORTED FROM STRUCTURE ABOVE, (3) SHEET METAL SCREWS BELOW WRAP INSULATION: OVERLAP MINIMUM 4", STAPLE AND TAPE FOR VAPOR SEAL(R-6 MINIMUM INSULATION) M I / IS FREE AREA\ I II SECURE INSULATION WITH STICK -PINS AT 18" O.C. AND ADHESIVE ON BOTTOM, FOR DUCTS 24" AND LARGER DUCT HANGER DETAIL SPIN -IN FITTING WITH SCOOP AND BALANCING DAMPER MINIMUM RADIUS EQUAL - TO FLEX DUCT DIAMETER PROVIDE MAXIMUM VERTICAL DUCT RUN INTO DIFFUSER FASTEN WITH (3) #10 TAPCON WEATHER RESISTANT SCREWS EACH SIDE. LOW VELOCITY SUPPLY AIR DUCT (SEE PLAN) NTS AIR FLOW SEAL JOINT WITH DUCT SEALER AND TAPE ROUND "SNAPLOCK" SHEET METAL FOR RUN -OUTS GREATER THAN 8", WITH 2" WRAP INSULATION. AN APPROVED ALTERNATE IS "SPIRO-PIPE", ESPECIALLY FOR LONG RUNS FLEXIBLE DUCT: DO NOT SAG OR KINK, INSULATED, MAXIMUM 8 FEET (R-6 MINIMUM INSULATION) WIRE SUPPORT FROM TOP OF FLEX 3 SHEET METAL SCREWS THROUGH HELIX OF FLEXIBLE DUCT, BAND CLAMP AND TAPED (TYPICAL) 2" WRAP INSULATION CUT, FIT, AND GLUED OVER CEILING DIFFUSER (R-6 MINIMUM INSULATION) CEILING DIFFUSER. SET THROW PER PLAN NTS EXHAUST FAN SCHEDULE EF # MANUF. MODEL # CFM DUCTING REMARKS EF-1 THRU EF-4 PANASONIC FV-08VQL5 80 4"0 TO ROOF CAP W/ DAMPER (SEE FLOOR PLAN) ULTRA SILENT SERIES AC EQUIPMENT SCHEDULE - CARRIER (OR APPROVED EQUIVALENT) A/C NUMBER: ACCU-1 ACCU-2 NOM. TONNAGE 2.5 3.0 0SEER: 16.0 16.0 z MODEL: 25HPB630A 25HPB636A zCAPACITY TOTAL COOLING (BTU/HR) 29,200 35,000 LUHEATING CAPACITY (BTU/HR) 34,000 40,000 z FAN FLA-HP 0.75 - 1 /10 0.75 - 1 /10 MCA/ MOCP (A) 19.9 / 30 21 .6 / 35 DIMENSIONS 35" x 35" x 32" 35" x 35" x 32" WEIGHT 227 235 AHU NUMBER: AHU-1 AHU-2 MODEL: FX4DNF031000 FX4DNF037000 W REFRIGERANT: R-410A R-410A J LOCATION: SEE PLANS SEE PLANS 0 z CFM : 1000 1200 Q FAN MOTOR HP/FLA: 1 /2 - 4.1 1 /2 - 4.1 I ELECTRIC HEATER: N/A N/A Q DIMENSIONS: 22" x 22" x 53" 22" x 22" x 50" MCA/ MOCP (AHU @ 240V) (A) 5.1 / 15 5.1 / 15 WEIGHT: 146 LBS 146 LBS REF LINES SIZES: 3/4" S - 3/8" L 3/4" S - 3/8" L OUTSIDE DESIGN: 95°F WB,79°F WB, WINTER 46°F DB NOTES: PROVIDE INTEGRAL CIRCUIT BREAKER DISCONNECT. w Q 0 U) z O > w 1 � I�INIMI I�I�1 D BTEK L L C CIVIL - MEP Phone: (954) 281-2760 email: julian@dbtekllc.com CA #33374 U LO 0 M C') O +r w L S Q 0 O Eo 06 U 3 o N M C L E M J* ° O o N A o °' ! U C:ti u) ~ 2 J w M ° Co 0) �E �L {2 N E N co U) C o W O Z o J O L.L O (n C' I z Q Q 0 J CD CD J U) CL G -4-- Co Co ' 00 CD W U ��CD M z o> 1, �--� • o 19 i, -I. & 0 U) U U)M M � O U W � Q Q • • °� U) J W i OL U : z 2 U) ROLANDO NIGAGLIONI, P.E. ENGINEER OF RECORD FLORIDA LIC.# 60494 0 m z Q Of 0 SHEET# U) Q W Wp 0 z (f� J Q W z U J Lu < C) = W J U=p CWUz G (j) Q M501 NTS