HomeMy WebLinkAboutPLUMBING PLANS3/4" A/C CC DRAIN TO E) BUILDING BUILD SANITARY FIRST FLOOR PLAN SCALE: 1 /4" = V-0" APPLICABLE BUILDING CODES BUILDING CODE: FBC 7th EDITION (2020) LIFE SAFETY: NFPA 101 (2015) PLUMBING LEGEND CO CLEAN OUT SANITARY SEWER PIPING S.O.V. SHUT-OFF VALVE S — — VENT PIPING COTC CLEAN OUT TO GRADE 5 DOMESTIC COLD WATER PIPING FD FLOOR DRAIN 5 HOT WATER PIPING (110°) — CIRCULATING LINE CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER �CD� CONDENSATE PIPING HWR DOMESTIC HOT WATER RETURN COMPRESSED AIR PIPING HB HOSE BIBB S--P&T� TEMPERATURE AND PRESSURE RELIEF VTR VENT THRU ROOF STORM DRAIN PIPING M GATE VALVE G GAS PIPING Dw GLOBE VALVE PIPE RISE OR DROP N CHECK VALVE PIPE RISER UP BALANCING VALVE E-- CAPPED END OF PIPE i GAS COCK Q­ CLEAN OUT QWATER HAMMER ARRESTOR 0--j P-TRAP • FD FLOOR DRAIN —c WATER HAMMER ARRESTOR 3/4" AC CONDENSATE DRAIN UP TO 2nd FLOOR, CONDENSATE DRAIN LINES IN CEILING SPACE SHALL BE INSULATED. 3/4" A/C CONDENSATE DRAIN TO EXTERIOR OF BUILDING (12" FROM BUILDING 6" AFF.) SANITARY SECOND FLOOR PLAN SCALE: 1 /4" = V-0" 3/4" AC CONDENSATE DRAIN DOWN TO 1st FLOOR, CONDENSATE DRAIN LINES IN CEILING SPACE SHALL BE INSULATED. NIGA Digitally signed V?�C ENj**- �0y' by Rolando * ; No. 60494 ; * IVlgagllonl * _ .p'. STATE OF Date: '0^--"Z 0 RIOP ' �2021-09-28 ,''FSSIONALE\ 20:21-04:00 Tni� Ite n a -en JcAal , s fined and sealed :D,. R, a -:jo Nicacl :;.i. F' _. -,, tie :Date >ccp ent to .-e sea'. nte:c::; p o .-is c :cu ne-i. a e r . ronsice ed s -a -ec s;- ! sz : er ,_,ric . e si,jratu,a nusi to vt;i fied an a—,-; w ztc.ion ccap -s w Q 0 U) z 0 w Of 1 � I�INIMI I�I�1 ID BTEK LLC CIVIL - MEP Phone: (954) 281-2760 email: julian@dbtekllc.com CA #33374 U LO o co co O w L � Q U) E O O 0U 6 7D o O O CO E CO O O N O U -o -0 04 Q ~ c6 OL J U) W Co 0 C a) 'L Q O E M U) C W o Z o 6; 0 O J LL 0 M i Z Q Q J O W co O W U � N > o M Z W o _ o o i �-�+ 0 Cn 0 cn 0 cy-) M O U W Q O w 0 co co Z :E cn ROLANDO NIGAGLIONI, P.E. ENGINEER OF RECORD FLORIDA LIC.# 60494 z ry p m o pw �e U J w LL r ^ �J J U p 7 o O U) LL, UQw m LLI J � J of of Z/�Q N \ N �W _z0 w � _ o LL Cn Z SHEET# H.B. W/ V BF H.B. ?" CW LINE TO WELL. E CIVIL PLANS CONTINUATION.) '/BACKFLOW PREVENTER ?" - SEE CIVIL PLANS FOR ATION. H.B. W/ VACUUM BREAKER PLUMBING LEGEND CO CLEAN OUT SANITARY SEWER PIPING S.O.V. SHUT-OFF VALVE S — — VENT PIPING COTC CLEAN OUT TO GRADE 5 DOMESTIC COLD WATER PIPING FD FLOOR DRAIN 5 HOT WATER PIPING (110°) — CIRCULATING LINE CW DOMESTIC COLD WATER HW DOMESTIC HOT WATER �---CD CONDENSATE PIPING HWR DOMESTIC HOT WATER RETURN COMPRESSED AIR PIPING HB HOSE BIBB S--P&T� TEMPERATURE AND PRESSURE RELIEF VTR VENT THRU ROOF �--SD STORM DRAIN PIPING pQ GATE VALVE G GAS PIPING Dw GLOBE VALVE PIPE RISE OR DROP N CHECK VALVE PIPE RISER UP BALANCING VALVE E-- CAPPED END OF PIPE i GAS COCK Q­ CLEAN OUT QWATER HAMMER ARRESTOR 0--j P-TRAP • FD FLOOR DRAIN —o WATER HAMMER ARRESTOR PLUMBING CONTRACTOR NOTES: 1. ALL PLUMBING FIXTURES SHALL COMPLY WITH FBC-P 604.0 2020 2. MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES FITTING AND APPLIANCES SHALL BE AS PER TABLE 604.4 OF FBC-P 2020 3. SOLID PIECE FULL BODY DIVERTERS ARE REQUIRED. 4. ALL DIVERTERS ARE TO BE COPPER (BETWEEN SHOWER HEAD AND TUB FAUCET). 5. DOUBLE SINKS MUST BE CONNECTED WITH TWO TEES, NOT ONE CROSS CONNECTOR. 6. ALL WATER PIPING OVERHEAD COPPER WITH PRO PRESS FITTINGS. 7. NO JOINTS UNDERGROUND FOR COPPER LINES. w Q 0 U) z O w Of 1 � I�INIMI I�I�1 ID BTEK LLC CIVIL - MEP Phone: (954) 281-2760 email: julian@dbtekllc.com CA #33374 U LO o co co O LL L � Q 0 U) E O 0 06 U � o 0 a) M E` CO O O � V N 0 O U -0 -0 04 Q :Ec6 ~ 2 J (n ul Co pj of E C a) �L Q O E O M U) O7 � C W o z o 8. SHOWERS AND TUBS SHALL BE EQUIPPED WITH CONTROLS VALVES OF THE PRESSURE - BALANCE, 1st. FLOOR FOR THERMOSTATICS MIXING OR COMBINATION. PRESSURE BALANCE / THERMOSTATIC MIXING VALVE TYPES _ _ _ _ _ _ _ _ (SEE CONTINUATION 0 WITH ASSE OR ASME Al 12.18.1 / CSA B125.1 - THE HIGH LIMIT STOP SHALL BE SET TO LIMIT WATER TEMPERATURE TO NOT GREATER THAN 1200 F. IN LINE THERMOSTATIC VALVES SHALL NOT BE USED. O " MASTER p co 9. WATER HAMMER ARRESTORS AS PER FBC-P 604.9. H LINES 3/4" CW7FFLOO 1 FOR BEDROOM Z to (SEE St CONTINUATION Q Q J O TABLE 604.4 C C 00 — — — G C) MAXIMUM FLOW RATES AND CONSUMPTION U CD FIXTURE TYPE GPM PSI w o6 ; CD I �J zLO O .. O BIDET 2.09 20 L1J O i LAVATORY, PRIVATE 1.5 @ 60 BEDROOM 0 U � � Z3 O SHOWER HEAD 2.0 @ 80 #1 _ SINK FAUCET 2.2 @ 60 w L Q M (1) WATER CLOSET 1.28 GAL - (PER FLUSH) Q DISHWASHER (ENERGY STAR- 6.5 GAL _ U (RESIDENTIAL) WATER SENSE CERTIFIED) (PER CYCLE) \ WASHING (ENERGY STAR- W.F. 8 z :E 0- 0- U) MACHINE WATER SENSE CERTIFIED) (OR LESS) - ROLANDO NIGAGLIONI, P.E. ENGINEER OF RECORD FLORIDA LIC.# 60494 z m 0 w Y U Lu 2 U N O WATER DISTRIBUTION FIRST FLOOR PLAN WATER DISTRIBUTION SECOND FLOOR PLAN N SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" L 0 D] O/ Z OQ On L,LZU) 0OD Z W O Umw L LI J Z 0 Q L u U) U)F- � 0�Q LSO SHEET# GUY GRAY SPACE SAVER WITW-4- DEEP BOX FOR METAL STUD WALL WATER HAMMER ARRE PLUMBING NOTES 1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES. 2. PLUMBING CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 3. ALL MATERIALS SHALL BE NEW. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. ALL EXCAVATION AND BACK FILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT. 5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 6. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TESTS, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO BEGINNING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. 7. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 8. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER/ARCHITECT. PRIOR TO BEGINNING CONSTRUCTION. 9. VERIFY LOCATION, SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES. 10. WATER PIPING SHALL BE TYPE "M" COPPER FOR 2" AND UNDER ALL UNDERGROUND WATER PIPING SHALL BE TYPE "L" COPPER ENCASED IN BLACK POLY PIPE. THE USE OF CPVC IS ALLOWED 11. SOIL, WASTE, VENT AND RAINWATER PIPING SHALL BE CAST IRON OR PVC. PVC MAY NOT BE USED THRU RATED ASSEMBLIES OR IN PLENUMS. 12. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS AND APPROPRIATELY MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR TO INSTALLATION. 13. FURNISH AND INSTALL APPROVED AIR CHAMBERS AT EACH PLUMBING FIXTURE GROUP AS PER CODE AND WITH GOOD ENGINEERING PRACTICE 14. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS; EXCEPT AT WATER HEATER AS PER CODE. 15. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PAD. 16. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE BY FILLING VOIDS BETWEEN PIPE AND WALL/FLOOR SLEEVES WITH FIRE RATED FOAM, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS AS PART OF THE PLUMBER'S WORK. 17. PLUMBING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF CERTIFICATE OF OCCUPANCY IS ISSUED. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE WITHIN 72 HRS. OF NOTIFICATION AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 18. STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL CODES. INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATIONS. 19. PROVIDE CHROME PLATED COMBINATION COVER PLATE AND CLEAN OUT PLUG OR ACCESS PANEL FOR ALL WALL CLEAN OUTS. 20. NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES WHERE USED AS RETURN AIR PLENUMS. 21. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR EQUIPMENT ROOMS. 22. WATER PIPING INSULATION SHALL BE 1" THICK ARMAFLEX INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS FOR ALL HOT WATER PIPING. WHERE DOMESTIC WATER TEMPERATURES CAN CAUSE SWEATING ALL COLD WATER PIPING SHALL BE INSULATED WITH 1/2" THICK ARMAFLEX INSULATION. 23. CONDENSATE DRAIN LINES TO BE RUN UNDER SLAB IN PVC SCH40 PIPE AND STUBBED OUT OF WALL TO UNIT. TIE IN OF A/C TO BE BY OTHERS. PVC PIPING WITH 1/2" THICK ARMAFLEX INSULATION MAY BE USED IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. SEE PLUMBING DRAWINGS FOR SIZE AND LOCATION OF PIPING. PVC WILL BE MIN. SCHEDULE 40 24. PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL SHUT-OFF. 25. NO JOINTS UNDERGROUND FOR COPPER. 26. PLUMBING FIXTURES SHALL COMPLY WITH F.B.C. 604. 27. WATER HAMMER ARRESTORS AS PER F.B.C. P-604.9. 28. PLUMBING CONTRACTOR TO PROVIDE ANTI -SCALDING VALVE FOR TUBS AND SHOWERS. 29. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS PRIOR TO INSTALLATION & BID. PAVED SURFACES FINISHED GRADE 3'-0" MIN. OR 4'-0" MAC FOR RESIDENTIAL SERVICE LOCATOR DISK-. 121, PROVIDE PLUG FOR FUTURE CONNECTION BY PROPERTY OWNER. CLEANOUT ADAPTER WITH THREADED PLUG. 1" IN ORDER TO ACCOMMODATE SOD CAST IRON BOX PVC, 45° BEND PVC, CLEANOUT WYE CE CONNECTION DIRECTION <:�_OF FLOW NOTES 1). PROVIDE APPROVED PLUG OR JOINT FOR DISSIMILAR GRAVITY SEWER PIPE FOR SERVICE CONNECTION. 2). CLEAN -OUT ASSEMBLY SHALL BE INSTALLED BY PROPERTY OWNER. TYPICAL CLEANOUT INSTALLATION • AS PER FBC P416.5: TEMPERED WATER SHALL BE DELIVERED THROUGH AN APPROVED WATER -TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE 1070 OR CS 13125.3. HOT WATER ___jy_r,_(j�" RECIRCULATING COLD WATER WATER HEATER DETAIL NTS HOT WATER HEATER UEF: 0.93 TANKLESS WATER HEATER �--240V CONNECTION H C PROVIDE WEATHER PROOF CAP FOR FUTURE TENANT AREA,�. �/� TU N AD PIPE DOWN INTO STACK SHEET LEAD FLASHING MOP W/ ROOFING MATERI#L-� 12" MIN. z N ING NTS R9OF CONSTRUCTION VENT STACK S VE ROOF CONSTRUCTION AS REQUIRED NOTE: ANY VENT FIRE WITHIN 10'-0" OF ANY DOOR, WINDOW, OR EXHAU: OPENINGS SHALL EXTEND NOT LESS THAN 3-0" ABOVE SUCH VENT THRU ROOF DETAIL NTS VENT LINE WITH - PERFORATED CAP. CONDENSATE TRAP DETAIL TE C.O. PLUG 3" ABOVE TC (SCREWED) PRIMARYOF DRAIN PAN UNION CONNE TSP +1" TSP +1" (3" MIN.) A. SLOPE DRAIN LINE TO CONDENSATE RECEPTOR (MIN. 1/8" PER FOOT) B. DRAIN LINE SHALL BE COPPER TYPE "L" AND INSULATED. C. TSP = FAN TOTAL STATIC PRESSURE. NTS c SANITARY RISER HANGERS AND RODS SHALL BE PLACED AT FOUR -FOOT CENTERS MAXIMUM. EACH FITTING SHALL HAVE A HANGER. THE RODS SHALL BE STAINLESS STEEL AND SHALL CONFORM WITH THE SIZES SHOWN IN TABLE 1. RODS SHALL EXTEND UP THROUGH THE FILL AND SHALL TERMINATE WITH A BEND OR HOOK THAT WILL BE EMBEDDED IN THE SLAB. CLAMP -ON HANGER SHALL MATCH THE PIPE SIZE AND THEY SHALL BE MADE OF HOT DIPPED GALVANIZED STEEL OR STAINLESS STEEL. THE HANGER SHALL BE FASTENED TO THE ROD SO THAT THE RODS ARE HELD IN A VERTICAL POSITION. PLASTIC DWV PIPING SUSPENDED FROM ON -GRADE SLABS. STANDARD GUIDE FOR INSTALLING PLASTIC DWV PIPING SUSPENDED FROM GRADE SLABS AS PER ASTM F2538-08B TABLE 1 HANGER RODS PIPE SIZES MINIMUM ROD SIZE 2 IN. AND SMALLER 3/8 IN. 3 IN. AND 4 IN. 1/2 IN. 6 IN. 5/8 IN. 8 IN. AND LARGER 3/4 IN. 6.1 PIPING SHALL BE INSTALLED AT THE PRESCRIBED ELEVATION AS THE FILL IS BEING PLACED WITHIN THE GRADE BEAM AREA OR THE PIPING SHALL BE INSTALLED IN TRENCHES CUT INTO THE FILL. 6.2 CLAMPING PIPE HANGERS WITH RODS EXTENDING UPWARD SHALL BE INSTALLED AS THE WORK PROGRESSES. THE CLAMPING HANGERS SHALL BE FASTENED SECURELY TO THE PIPE OR FITTING AND SHALL HOLD THE ROD VERTICALLY. ON GRADE SLAB PEA GRAVEL OR CLEAN SAND FILL n 2" STUDOR 2" VTR VENT JA2" VTR „ I 2 (2) SHEETS OF 1" FOAM INSULATION FASTENED TO HANGER RODS WITH WIRE TIES. SH 2° ,NTITY 2" MIN. SIZE UNDER SLAB DRAIN. 2" OR LESS DRAIN @ 1/4" DROP 3" @ 1/8" 4" @ 1/8" SCALE: N.T.S. 7.2 WHEREVER THE TOP OF THE SUSPENDED PIPING IS MORE THAN 6 INCHES BELOW THE BOTTOM OF THE CONCRETE SLAB THE LOADING ON THE PIPING SHALL BE LIMITED BY ONE OF THE FOLLOWING TWO METHODS SEE FIG. 1. 7.2.1 PEA GRAVEL OR CLEAN SAND FILL - THIS SELECTED FILL SHALL BE PLACED AROUND AND ABOVE THE PIPE LINE ALL THE WAY UP TO THE SLAB GRADE. IN ADDITION THE SAME FILL SHALL BE PROVIDE FOR A DISTANCE OF 12 IN. OR MORE ON BOTH SIDES OF THE PIPE LINE. DURING THE PLACEMENT OF THIS FILL, THE HANGER RODS SHALL BE KEPT VERTICAL AND THEY SHALL BE IN ALIGNMENT DIRECTLY ABOVE THE PIPES. 7.2.2 FOAM INSULATION SHEAR PLANE - SHEETS OF 1 IN. THICK FOAM INSULATION SHALL BE PLACED ON BOTH SIDES OF THE RODS AND SHALL EXTEND DOWN TO AND OVER THE PIPE TO THE CENTERLINE. FASTEN THE TWO SHEETS TOGETHER AT EACH HANGER WITH WIRE TIES. THE MAXIMUM FOAM SHEET WIDTH REQUIRED IS 48 IN. BACKFILL SHALL BE PLACED ON BOTH SIDES OF THE INSULATION SO THAT THE RODS AND INSULATION REMAIN VERTICALLY. w Q 0 W z O w 1 � I�INIMI I�I�1 D BTEK LLC CIVIL - MEP Phone: (954) 281-2760 email: julian@dbtekllc.com CA #33374 U � C 0 c7 � M O LL w L � Q �u)E O 0 06 U o0 a) M 0 E M O 0 @N rn U -0 Q co � Ui ~ 0 J W 0 Co pj 6� E C a) �L Q O E O c� �U) O J L.L 0 M z Q Q J O C� G c: � 00 O W U 0 O M Z LLJ o> '.I'. O rn i � 0 U) U cn N 0Lo co O U W Q L.L U) O J Z :E cn ROLANDO NIGAGLIONI, P.E. ENGINEER OF RECORD FLORIDA LIC.# 60494 z m 0 w Y U Lu U O W m U) 0 U) of Z 0 �cDw Z V N 0 < W W � w Q J a M Cn 0- Q SHEET# P501