Loading...
HomeMy WebLinkAboutREV1-ENCODEFORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 75 The lower the EnergyPerformance Index, the more efficient the home. MAIN STREET,FORT PIERCE,FL,34982 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case? No 6. Conditioned floor area above grade (ft²) 2490 Conditioned floor area below grade (ft²) 0 7. Windows** Description Area a. U-Factor: Sgl, U=1.11 206.67 ft 2 S H G C : SHGC=0.23 b. U-Factor: Sgl, U=1.04 138.63 ft 2 S H G C : SHGC=0.25 c. U-Factor: Sgl, U=1.06 86.98 ft 2 S H G C : SHGC=0.25 Area Weighted Average Overhang Depth: 4.525 ft Area Weighted Average SHGC: 0.244 8. Skylights Description Area U - F a c t o r : ( A V G ) N/A N/A ft 2 S H G C ( A V G ) : N/A 9. Floor Types I n s u l a t i o n Area a. Slab-On-Grade Edge Insulation R= 0.0 1245.00 f t2 b. N/A R = f t2 c. N/A R = f t2 10. Wall Types(2833.3 sqft.) I n s u l a t i o n Area a. Concrete Block - Ext Insul, ExteriorR=5.0 2602.30 ft 2 b. Concrete Block - Int Insul, AdjacentR=5.0 231.00 ft 2 c. N/A R = f t2 d. N/A R= f t2 11. Ceiling Types(1245.0 sqft.) I n s u l a t i o n Area a. Under Attic (Vented) R=30.0 1245.00 ft 2 b. N/A R= f t2 c. N/A R= f t2 12. Ducts, location & insulation level R ft 2 a. a. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 8 400 b. b. Sup: Attic, Ret: Attic, AH: 2nd Floor 8 384.4 c . 13. Cooling Systems k B t u / h r Efficiency a. Central Unit 30.0 SEER:16.00 b. Central Unit 36.0 SEER:16.00 14. Heating Systems k B t u / h r Efficiency a. Electric Heat Pump 34.0 HSPF:9.00 b. Electric Heat Pump 40.0 HSPF:8.50 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons EF: 0.980 b. Conservation features None 16. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: ___________________________________ Date: _________________________ Address of New Home: MAIN STREET City/FL Zip: FORT PIERCE,FL,34982 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/23/2021 12:22:24 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SCOUTTO RESIDENCE Builder Name: Street: MAIN STREET Permit Office: City, State, Zip: FORT PIERCE, FL, 34982 Permit Number: Owner: Jurisdiction: 661100 Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 3 5. Is this a worst case? No 6. Conditioned floor area above grade (ft²) 2490 Conditioned floor area below grade (ft²) 0 7. Windows(506.4 sqft.) Description Area a. U-Factor: Sgl, U=1.11 206.67 ft 2 S H G C : SHGC=0.23 b. U-Factor: Sgl, U=1.04 138.63 ft 2 S H G C : SHGC=0.25 c. U-Factor: Sgl, U=1.06 86.98 ft 2 S H G C : SHGC=0.25 Area Weighted Average Overhang Depth: 4.525 ft Area Weighted Average SHGC: 0.244 8. Skylights Description Area U - F a c t o r : ( A V G ) N/A N/A ft 2 S H G C ( A V G ) : N/A 9. Floor Types I n s u l a t i o n Area a. Slab-On-Grade Edge Insulation R= 0.0 1245.00 f t2 b. N/A R = f t2 c. N/A R = f t2 10. Wall Types(2833.3 sqft.) I n s u l a t i o n Area a. Concrete Block - Ext Insul, ExteriorR=5.0 2602.30 ft 2 b. Concrete Block - Int Insul, AdjacentR=5.0 231.00 ft 2 c. N/A R = f t2 d. N/A R= f t2 11. Ceiling Types(1245.0 sqft.) I n s u l a t i o n Area a. Under Attic (Vented) R=30.0 1245.00 ft 2 b. N/A R= f t2 c. N/A R= f t2 12. Ducts, location & insulation level R ft 2 a. a. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 8 400 b. b. Sup: Attic, Ret: Attic, AH: 2nd Floor 8 384.4 c . 13. Cooling Systems k B t u / h r Efficiency a. Central Unit 30.0 SEER:16.00 b. Central Unit 36.0 SEER:16.00 14. Heating Systems k B t u / h r Efficiency a. Electric Heat Pump 34.0 HSPF:9.00 b. Electric Heat Pump 40.0 HSPF:8.50 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons EF: 0.980 b. Conservation features None 16. Credits CF, Pstat Glass/Floor Area: 0.203 Total Proposed Modified Loads: 59.74 Total Baseline Loads: 79.56 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: _________________________________ Before construction is completed this building will be inspected for DATE: _________________________________________ compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: __________________________________ BUILDING OFFICIAL: ____________________________ DATE: _________________________________________ DATE: _________________________________________ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. - Compliance requires a roof absorptance test and a roof emittance test in accordance with R405.7.2 - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 9/23/2021 12:21:13 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 Rolando Nigaglioni, P.E. 09-23-2021 12-08-2021 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: SCOUTTO RESIDENCE Address type: Street Address Building Type: Bedrooms: Lot #:User 3 --- Owner: Conditioned Area: Block/SubDivision:2490 --- Total Stories: PlatBook:2 --- Builder Name: Worst Case: Street:No MAIN STREET Permit Office: Rotate Angle: County:0 St. Lucie Jurisdiction: Cross Ventilation: City, State, Zip:661100 No FORT PIERCE, Family Type: Whole House Fan:Detached No FL, 34982 New/Existing: Terrain:New (From Plans) Suburban Year Construct: Shielding:2021 Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range ___ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume ___ 1 Block1 1245 11205 ___ 2 Block2 1245 11205 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated ___ 1 1st Floor 1245 11205 Yes 0 0 Yes Yes Yes ___ 2 2nd Floor 1245 11205 No 4 3 Yes Yes Yes FLOORS (Total Exposed Area = 1245 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet ___ 1 Slab-On-Grade Edge Ins 1st Floor 190 0 1245 ft 0.657 --- 0.60 0.00 0.40 ROOF Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor.Barr Tested Tested Insul. (deg) ___ 1 Hip Composition shingles 1496 ft² 0 ft² Light N 0.6 Yes 0.9 Yes 0 33.69 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC ___ 1 Full attic Vented 300 1245 ft² N N CEILING (Total Exposed Area = 1245 sq.ft.) # Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type ___ 1 Under Attic(Vented) 2nd Floor 30.0 Batt 1245.0ft² 0.044 0.11 Wood 9/23/2021 12:21:13 AM Page 2EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS (Total Exposed Area = 2833 sq.ft.) Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below # Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade ___ 1 W Exterior Conc. Blk - Ext Ins 1st Floor 5.0 32.0 4 11.0 0 355.7 0.117 0 0 0.01 0 % ___ 2 W Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 32.0 4 9.0 0 291.0 0.117 0 0 0.75 0 % ___ 3 N Exterior Conc. Blk - Ext Ins 1st Floor 5.0 26.0 4 11.0 0 289.7 0.117 0 0 0.75 0 % ___ 4 N Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 38.0 6 9.0 0 346.5 0.117 0 0 0.75 0 % ___ 5 E Exterior Conc. Blk - Ext Ins 1st Floor 5.0 32.0 4 11.0 0 355.7 0.117 0 0 0.01 0 % ___ 6 E Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 32.0 4 9.0 0 291.0 0.117 0 0 0.75 0 % ___ 7 S Exterior Conc. Blk - Ext Ins 1st Floor 5.0 17.0 6 11.0 0 192.5 0.117 0 0 0.75 0 % ___ 8 S Garage Conc. Blk - Int Ins 1st Floor 5.0 21.0 0 11.0 0 231.0 0.132 0 0 0.75 0 % ___ 9 S Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 17.0 6 9.0 0 157.5 0.117 0 0 0.75 0 % ___ 10 S Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 21.0 0 9.0 0 189.0 0.117 0 0 0.75 0 % ___ 11 N Exterior Conc. Blk - Ext Ins 1st Floor 5.0 12.0 2 11.0 0 133.8 0.117 0 0 0.75 0 % DOORS (Total Exposed Area = 42 sq.ft.) Width Height # Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area ___ 1 W Exterior Insulated 1st Floor Metal 0.46 3.00 0 7.00 0 21.0ft² ___ 2 S Garage Insulated 1st Floor Metal 0.46 3.00 0 7.00 0 21.0ft² WINDOWS (Total Exposed Area = 506 sq.ft.) Wall -----Overhang----- # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening ___ 1 W 1 Metal Single (Clear) Yes 1.04 0.25 Y N 13.1ft² 1.0 ft 0 in 12.0 ft 0 in IECC 2012 None ___ 2 W 2 Metal Single (Clear) Yes 1.06 0.25 Y N 6.9ft² 1.0 ft 0 in 1.0 ft 10 in IECC 2012 None ___ 3 N 3 Metal Single (Clear) Yes 1.06 0.25 Y N 25.5ft² 8.0 ft 0 in 1.0 ft 8 in IECC 2012 None ___ 4 N 3 Metal Single (Clear) Yes 1.11 0.23 Y N 86.7ft² 8.0 ft 0 in 1.0 ft 8 in IECC 2012 None ___ 5 N 11 Metal Single (Clear) Yes 1.04 0.25 Y N 30.0ft² 1.0 ft 6 in 12.0 ft 0 in IECC 2012 None ___ 6 N 4 Metal Single (Clear) Yes 1.11 0.23 Y N 40.0ft² 1.0 ft 6 in 1.0 ft 10 in IECC 2012 None ___ 7 N 4 Metal Single (Clear) Yes 0.99 0.27 Y N 54.2ft² 1.0 ft 6 in 1.0 ft 10 in IECC 2012 None ___ 8 N 4 Metal Single (Clear) Yes 1.06 0.25 Y N 6.9ft² 1.0 ft 6 in 1.0 ft 10 in IECC 2012 None ___ 9 E 5 Metal Single (Clear) Yes 1.04 0.25 Y N 39.3ft² 1.0 ft 0 in 12.0 ft 8 in IECC 2012 None ___ 10E 5 Metal Single (Clear) Yes 1.06 0.25 Y N 6.9ft² 1.0 ft 0 in 12.0 ft 8 in IECC 2012 None ___ 11E 6 Metal Single (Clear) Yes 1.04 0.25 Y N 26.2ft² 1.0 ft 0 in 1.0 ft 10 in IECC 2012 None ___ 12S 7 Metal Single (Clear) Yes 1.04 0.25 Y N 30.0ft² 8.0 ft 0 in 2.0 ft 4 in IECC 2012 None ___ 13S 7 Metal Single (Clear) Yes 1.06 0.25 Y N 40.7ft² 8.0 ft 0 in 2.0 ft 4 in IECC 2012 None ___ 14S 9 Metal Single (Clear) Yes 1.11 0.23 Y N 40.0ft² 8.0 ft 0 in 1.0 ft 10 in IECC 2012 None ___ 15S 9 Metal Single (Clear) Yes 1.02 0.26 Y N 20.0ft² 8.0 ft 0 in 1.0 ft 10 in IECC 2012 None ___ 16S 10 Metal Single (Clear) Yes 1.11 0.23 Y N 40.0ft² 1.0 ft 6 in 1.0 ft 10 in IECC 2012 None INFILTRATION # Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s) ___ 1 Wholehouse Proposed ACH(50) 0.00029 1868 102.46 192.35 0.1248 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation ___ 1 434 ft² 434 ft² 21 ft 10 ft 5 9/23/2021 12:21:13 AM Page 3EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS # Mass Type Area Thickness Furniture Fraction Space ___ 1 Default(8 lbs/sq.ft.) 0 ft² 0 ft 0.30 1st Floor ___ 2 Default(8 lbs/sq.ft.) 0 ft² 0 ft 0.30 2nd Floor HEATING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity ----Geothermal HeatPump---- Ducts Block kBtu/hr Entry Power Volt Current ___ 1 Electric Heat Pump Split/Single HSPF: 9.00 34.0 0.00 0.00 0.00 sys#1 1 ___ 2 Electric Heat Pump Split/Single HSPF: 8.50 40.0 0.00 0.00 0.00 sys#2 2 COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm ___ 1 Central Unit None/Single SEER:16.0 30.0 900 0.75 sys#1 1 ___ 2 Central Unit Split/Single SEER:16.0 36.0 1080 0.75 sys#2 2 HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length ___ 1 Electric Tankless 1st Floor 0.98 (0.98) 1.00 gal 60 gal 120 deg Standard None 99 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff ___ 1 No NA NA NA No NA NA NA None DUCTS Duct ---------Supply--------- ---------Return--------- Air CFM 25 CFM 25 HVAC # # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool ___ 1 1st Floor 8.0 400 ft² 1st Floor 8.0 100 ft² Prop. Leak Free 1st Floor --- --- 0.03 0.50 1 1 ___ 2 Attic 8.0 384 ft² Attic 8.0 100 ft² Prop. Leak Free 2nd Floor --- --- 0.03 0.50 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: N Cooling [X] Jan [X] Feb [X] Mar [X] Apr [X] May [X] Jun [X] Jul [X] Aug [X] Sep [X] Oct [X] Nov [X] Dec Heating [X] Jan [X] Feb [X] Mar [X] Apr [X] May [X] Jun [X] Jul [X] Aug [X] Sep [X] Oct [X] Nov [X] Dec Venting [X] Jan [X] Feb [X] Mar [X] Apr [X] May [X] Jun [X] Jul [X] Aug [X] Sep [X] Oct [X] Nov [X] Dec Thermostat Schedule: FloridaCode 2014 Hours Schedule Type 123456789101112 ___ Cooling (WD) AM 75 75 75 75 75 75 75 75 75 75 75 75PM 75 75 75 75 75 75 75 75 75 75 75 75 ___ Cooling (WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75PM 75 75 75 75 75 75 75 75 75 75 75 75 ___ Heating (WD) AM 72 72 72 72 72 72 72 72 72 72 72 72PM 72 72 72 72 72 72 72 72 72 72 72 72 9/23/2021 12:21:13 AM Page 4EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES(Continued) ___ Heating (WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72PM 72 72 72 72 72 72 72 72 72 72 72 72 9/23/2021 12:21:13 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 Air System Sizing Summary for SCOUTTO RES ZONE #1 Project Name: SCOUTTO RES ZONE #1 Prepared by:51(QJLQHHULQJ,QVSHFWLRQ &RQVWUXFWLRQ,QF Air System Information Air System Name SCOUTTO RES ZONE #1 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 1250.0 ft² Location FORT PIERCE, Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Calculation Months Jan to Dec Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 2.2 Tons Total coil load 26.4 MBH Sensible coil load 25.6 MBH Coil CFM at Jul 1700 1024 CFM Max block CFM 1024 CFM Sum of peak zone CFM 1024 CFM Sensible heat ratio 0.973 ft²/Ton 568.9 BTU/(hr-ft²) 21.1 Water flow @ 10.0 °F rise N/A Load occurs at Jul 1700 OA DB / WB 89.9 / 76.7 °F Entering DB / WB 77.3 / 61.9 °F Leaving DB / WB 54.1 / 52.7 °F Coil ADP 51.5 °F Bypass Factor 0.100 Resulting RH 40 % Design supply temp. 55.0 °F Zone T-stat Check 0 of 1 OK Max zone temperature deviation 2.0 °F Central Heating Coil Sizing Data Max coil load 9.9 MBH Coil CFM at Des Htg 1024 CFM Max coil CFM 1024 CFM Water flow @ 20.0 °F drop N/A Load occurs at Des Htg BTU/(hr-ft²) 7.9 Ent. DB / Lvg DB 69.5 / 78.5 °F Supply Fan Sizing Data Actual max CFM 1024 CFM Standard CFM 1023 CFM Actual max CFM/ft² 0.82 CFM/ft² Fan motor BHP 0.21 BHP Fan motor kW 0.17 kW Fan static 0.75 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/ft² 0.00 CFM/ft² CFM/person 0.00 CFM/person Hourly Analysis Program v4.70 Page 1 of 2 0/22/2021 1:PM Zone Sizing Summary for SCOUTTO RES ZONE #1 0/22/2021 1:PM Air System Information Air System Name SCOUTTO RES ZONE #1 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 1250.0 ft² Location FORT PIERCE, Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Calculation Months Jan to Dec Sizing Data Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow Peak Load Area Zone Zone Name (MBH)(CFM)(CFM)Load (MBH)(ft²)CFM/ft² Zone 1 19.3 993 993 Jul 1700 10.8 1250.0 0.79 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Cooling Time Air Heating Floor Zone Name /Sensible of Flow Load Area Space Space Name Mult.(MBH)Load (CFM)(MBH)(ft²)CFM/ft² Zone 1 SCOUTTO RES ZONE#1 1 19.3 Jul 1700 993 10.8 1250.0 0.79 Hourly Analysis Program v4.70 Page 2 of 2 Project Name: SCOUTTO RES ZONE #1 Prepared by:51(QJLQHHULQJ,QVSHFWLRQ &RQVWUXFWLRQ,QF Air System Sizing Summary for SCOUTTO RES ZONE #2 0/22/2021 Project Name: SCOUTTO RES ZONE #2 Prepared by: 51(QJLQHHULQJ,QVSHFWLRQ &RQVWUXFWLRQ,QF1:PM Air System Information Air System Name SCOUTTO RES ZONE #2 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 1250.0 ft² Location FORT PIERCE, Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Calculation Months Jan to Dec Sizing Data Calculated Central Cooling Coil Sizing Data Total coil load 2.6 Tons Total coil load 30.9 MBH Sensible coil load 30.1 MBH Coil CFM at Jul 1700 1204 CFM Max block CFM 1204 CFM Sum of peak zone CFM 1204 CFM Sensible heat ratio 0.973 ft²/Ton 485.4 BTU/(hr-ft²) 24.7 Water flow @ 10.0 °F rise N/A Load occurs at Jul 1700 OA DB / WB 89.9 / 76.7 °F Entering DB / WB 77.3 / 61.8 °F Leaving DB / WB 54.1 / 52.7 °F Coil ADP 51.6 °F Bypass Factor 0.100 Resulting RH 41 % Design supply temp. 55.0 °F Zone T-stat Check 0 of 1 OK Max zone temperature deviation 2.0 °F Central Heating Coil Sizing Data Max coil load 10.8 MBH Coil CFM at Des Htg 1204 CFM Max coil CFM 1204 CFM Water flow @ 20.0 °F drop N/A Load occurs at Des Htg BTU/(hr-ft²) 8.7 Ent. DB / Lvg DB 69.5 / 77.8 °F Supply Fan Sizing Data Actual max CFM 1204 CFM Standard CFM 1204 CFM Actual max CFM/ft² 0.96 CFM/ft² Fan motor BHP 0.25 BHP Fan motor kW 0.20 kW Fan static 0.75 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/ft² 0.00 CFM/ft² CFM/person 0.00 CFM/person Hourly Analysis Program v4.70 Page 1 of 2 Zone Sizing Summary for SCOUTTO RES ZONE #2 Air System Information Air System Name SCOUTTO RES ZONE #2 Equipment Class SPLT AHU Air System Type SZCAV Number of zones 1 Floor Area 1250.0 ft² Location FORT PIERCE, Florida Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Calculation Months Jan to Dec Sizing Data Calculated Zone Sizing Data Maximum Design Minimum Time Maximum Zone Cooling Air Air of Heating Floor Sensible Flow Flow Peak Load Area Zone Zone Name (MBH)(CFM)(CFM)Load (MBH)(ft²)CFM/ft² Zone 1 22.7 1168 1168 Jul 1700 12.2 1250.0 0.93 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Cooling Time Air Heating Floor Zone Name /Sensible of Flow Load Area Space Space Name Mult.(MBH)Load (CFM)(MBH)(ft²)CFM/ft² Zone 1 SCOUTTO RES ZONE#2 1 22.7 Jul 1700 1168 12.2 1250.0 0.93 Hourly Analysis Program v4.70 Page 2 of 2 0/22/2021 1:PM Project Name: SCOUTTO RES ZONE #2 Prepared by: 51(QJLQHHULQJ,QVSHFWLRQ &RQVWUXFWLRQ,QF