HomeMy WebLinkAboutREV1-ENCODEFORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 75
The lower the EnergyPerformance Index, the more efficient the home.
MAIN STREET,FORT PIERCE,FL,34982
1. New construction or existing New (From Plans)
2. Single family or multiple family Detached
3. Number of units, if multiple family 1
4. Number of Bedrooms 3
5. Is this a worst case? No
6. Conditioned floor area above grade (ft²) 2490
Conditioned floor area below grade (ft²) 0
7. Windows** Description Area
a. U-Factor: Sgl, U=1.11 206.67 ft
2
S H G C : SHGC=0.23
b. U-Factor: Sgl, U=1.04 138.63 ft
2
S H G C : SHGC=0.25
c. U-Factor: Sgl, U=1.06 86.98 ft
2
S H G C : SHGC=0.25
Area Weighted Average Overhang Depth: 4.525 ft
Area Weighted Average SHGC: 0.244
8. Skylights Description Area
U - F a c t o r : ( A V G ) N/A N/A ft
2
S H G C ( A V G ) : N/A
9. Floor Types I n s u l a t i o n Area
a. Slab-On-Grade Edge Insulation R= 0.0 1245.00 f t2
b. N/A R = f t2
c. N/A R = f t2
10. Wall Types(2833.3 sqft.) I n s u l a t i o n Area
a. Concrete Block - Ext Insul, ExteriorR=5.0 2602.30 ft
2
b. Concrete Block - Int Insul, AdjacentR=5.0 231.00 ft
2
c. N/A R = f t2
d. N/A R= f t2
11. Ceiling Types(1245.0 sqft.) I n s u l a t i o n Area
a. Under Attic (Vented) R=30.0 1245.00 ft
2
b. N/A R= f t2
c. N/A R= f t2
12. Ducts, location & insulation level R ft
2
a. a. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 8 400
b. b. Sup: Attic, Ret: Attic, AH: 2nd Floor 8 384.4
c .
13. Cooling Systems k B t u / h r Efficiency
a. Central Unit 30.0 SEER:16.00
b. Central Unit 36.0 SEER:16.00
14. Heating Systems k B t u / h r Efficiency
a. Electric Heat Pump 34.0 HSPF:9.00
b. Electric Heat Pump 40.0 HSPF:8.50
15. Hot Water Systems
a. ElectricTankless Cap: 1 gallons
EF: 0.980
b. Conservation features
None
16. Credits CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: ___________________________________ Date: _________________________
Address of New Home: MAIN STREET City/FL Zip: FORT PIERCE,FL,34982
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
9/23/2021 12:22:24 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SCOUTTO RESIDENCE Builder Name:
Street: MAIN STREET Permit Office:
City, State, Zip: FORT PIERCE, FL, 34982 Permit Number:
Owner: Jurisdiction: 661100
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From Plans)
2. Single family or multiple family Detached
3. Number of units, if multiple family 1
4. Number of Bedrooms 3
5. Is this a worst case? No
6. Conditioned floor area above grade (ft²) 2490
Conditioned floor area below grade (ft²) 0
7. Windows(506.4 sqft.) Description Area
a. U-Factor: Sgl, U=1.11 206.67 ft
2
S H G C : SHGC=0.23
b. U-Factor: Sgl, U=1.04 138.63 ft
2
S H G C : SHGC=0.25
c. U-Factor: Sgl, U=1.06 86.98 ft
2
S H G C : SHGC=0.25
Area Weighted Average Overhang Depth: 4.525 ft
Area Weighted Average SHGC: 0.244
8. Skylights Description Area
U - F a c t o r : ( A V G ) N/A N/A ft
2
S H G C ( A V G ) : N/A
9. Floor Types I n s u l a t i o n Area
a. Slab-On-Grade Edge Insulation R= 0.0 1245.00 f t2
b. N/A R = f t2
c. N/A R = f t2
10. Wall Types(2833.3 sqft.) I n s u l a t i o n Area
a. Concrete Block - Ext Insul, ExteriorR=5.0 2602.30 ft
2
b. Concrete Block - Int Insul, AdjacentR=5.0 231.00 ft
2
c. N/A R = f t2
d. N/A R= f t2
11. Ceiling Types(1245.0 sqft.) I n s u l a t i o n Area
a. Under Attic (Vented) R=30.0 1245.00 ft
2
b. N/A R= f t2
c. N/A R= f t2
12. Ducts, location & insulation level R ft
2
a. a. Sup: 1st Floor, Ret: 1st Floor, AH: 1st Floor 8 400
b. b. Sup: Attic, Ret: Attic, AH: 2nd Floor 8 384.4
c .
13. Cooling Systems k B t u / h r Efficiency
a. Central Unit 30.0 SEER:16.00
b. Central Unit 36.0 SEER:16.00
14. Heating Systems k B t u / h r Efficiency
a. Electric Heat Pump 34.0 HSPF:9.00
b. Electric Heat Pump 40.0 HSPF:8.50
15. Hot Water Systems
a. ElectricTankless Cap: 1 gallons
EF: 0.980
b. Conservation features
None
16. Credits CF, Pstat
Glass/Floor Area: 0.203 Total Proposed Modified Loads: 59.74
Total Baseline Loads: 79.56 PASS
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: _________________________________ Before construction is completed
this building will be inspected for
DATE: _________________________________________ compliance with Section 553.908
Florida Statutes.
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT: __________________________________ BUILDING OFFICIAL: ____________________________
DATE: _________________________________________ DATE: _________________________________________
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
- Compliance requires a roof absorptance test and a roof emittance test in accordance with R405.7.2
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
9/23/2021 12:21:13 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
Rolando Nigaglioni, P.E.
09-23-2021
12-08-2021
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: SCOUTTO RESIDENCE Address type: Street Address
Building Type: Bedrooms: Lot #:User 3 ---
Owner: Conditioned Area: Block/SubDivision:2490 ---
Total Stories: PlatBook:2 ---
Builder Name: Worst Case: Street:No MAIN STREET
Permit Office: Rotate Angle: County:0 St. Lucie
Jurisdiction: Cross Ventilation: City, State, Zip:661100 No FORT PIERCE,
Family Type: Whole House Fan:Detached No FL, 34982
New/Existing: Terrain:New (From Plans) Suburban
Year Construct: Shielding:2021 Suburban
Comment:
CLIMATE
Design Design Temp Int Design Temp Heating Design Daily temp
Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
___ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
___ 1 Block1 1245 11205
___ 2 Block2 1245 11205
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated
___ 1 1st Floor 1245 11205 Yes 0 0 Yes Yes Yes
___ 2 2nd Floor 1245 11205 No 4 3 Yes Yes Yes
FLOORS (Total Exposed Area = 1245 sq.ft.)
# Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet
___ 1 Slab-On-Grade Edge Ins 1st Floor 190 0 1245 ft 0.657 --- 0.60 0.00 0.40
ROOF
Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor.Barr Tested Tested Insul. (deg)
___ 1 Hip Composition shingles 1496 ft² 0 ft² Light N 0.6 Yes 0.9 Yes 0 33.69
ATTIC
# Type Ventilation Vent Ratio (1 in) Area RBS IRCC
___ 1 Full attic Vented 300 1245 ft² N N
CEILING (Total Exposed Area = 1245 sq.ft.)
# Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac. Truss Type
___ 1 Under Attic(Vented) 2nd Floor 30.0 Batt 1245.0ft² 0.044 0.11 Wood
9/23/2021 12:21:13 AM Page 2EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS (Total Exposed Area = 2833 sq.ft.)
Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below
# Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade
___ 1 W Exterior Conc. Blk - Ext Ins 1st Floor 5.0 32.0 4 11.0 0 355.7 0.117 0 0 0.01 0 %
___ 2 W Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 32.0 4 9.0 0 291.0 0.117 0 0 0.75 0 %
___ 3 N Exterior Conc. Blk - Ext Ins 1st Floor 5.0 26.0 4 11.0 0 289.7 0.117 0 0 0.75 0 %
___ 4 N Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 38.0 6 9.0 0 346.5 0.117 0 0 0.75 0 %
___ 5 E Exterior Conc. Blk - Ext Ins 1st Floor 5.0 32.0 4 11.0 0 355.7 0.117 0 0 0.01 0 %
___ 6 E Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 32.0 4 9.0 0 291.0 0.117 0 0 0.75 0 %
___ 7 S Exterior Conc. Blk - Ext Ins 1st Floor 5.0 17.0 6 11.0 0 192.5 0.117 0 0 0.75 0 %
___ 8 S Garage Conc. Blk - Int Ins 1st Floor 5.0 21.0 0 11.0 0 231.0 0.132 0 0 0.75 0 %
___ 9 S Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 17.0 6 9.0 0 157.5 0.117 0 0 0.75 0 %
___ 10 S Exterior Conc. Blk - Ext Ins 2nd Floor 5.0 21.0 0 9.0 0 189.0 0.117 0 0 0.75 0 %
___ 11 N Exterior Conc. Blk - Ext Ins 1st Floor 5.0 12.0 2 11.0 0 133.8 0.117 0 0 0.75 0 %
DOORS (Total Exposed Area = 42 sq.ft.)
Width Height
# Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area
___ 1 W Exterior Insulated 1st Floor Metal 0.46 3.00 0 7.00 0 21.0ft²
___ 2 S Garage Insulated 1st Floor Metal 0.46 3.00 0 7.00 0 21.0ft²
WINDOWS (Total Exposed Area = 506 sq.ft.)
Wall -----Overhang-----
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening
___ 1 W 1 Metal Single (Clear) Yes 1.04 0.25 Y N 13.1ft² 1.0 ft 0 in 12.0 ft 0 in IECC 2012 None
___ 2 W 2 Metal Single (Clear) Yes 1.06 0.25 Y N 6.9ft² 1.0 ft 0 in 1.0 ft 10 in IECC 2012 None
___ 3 N 3 Metal Single (Clear) Yes 1.06 0.25 Y N 25.5ft² 8.0 ft 0 in 1.0 ft 8 in IECC 2012 None
___ 4 N 3 Metal Single (Clear) Yes 1.11 0.23 Y N 86.7ft² 8.0 ft 0 in 1.0 ft 8 in IECC 2012 None
___ 5 N 11 Metal Single (Clear) Yes 1.04 0.25 Y N 30.0ft² 1.0 ft 6 in 12.0 ft 0 in IECC 2012 None
___ 6 N 4 Metal Single (Clear) Yes 1.11 0.23 Y N 40.0ft² 1.0 ft 6 in 1.0 ft 10 in IECC 2012 None
___ 7 N 4 Metal Single (Clear) Yes 0.99 0.27 Y N 54.2ft² 1.0 ft 6 in 1.0 ft 10 in IECC 2012 None
___ 8 N 4 Metal Single (Clear) Yes 1.06 0.25 Y N 6.9ft² 1.0 ft 6 in 1.0 ft 10 in IECC 2012 None
___ 9 E 5 Metal Single (Clear) Yes 1.04 0.25 Y N 39.3ft² 1.0 ft 0 in 12.0 ft 8 in IECC 2012 None
___ 10E 5 Metal Single (Clear) Yes 1.06 0.25 Y N 6.9ft² 1.0 ft 0 in 12.0 ft 8 in IECC 2012 None
___ 11E 6 Metal Single (Clear) Yes 1.04 0.25 Y N 26.2ft² 1.0 ft 0 in 1.0 ft 10 in IECC 2012 None
___ 12S 7 Metal Single (Clear) Yes 1.04 0.25 Y N 30.0ft² 8.0 ft 0 in 2.0 ft 4 in IECC 2012 None
___ 13S 7 Metal Single (Clear) Yes 1.06 0.25 Y N 40.7ft² 8.0 ft 0 in 2.0 ft 4 in IECC 2012 None
___ 14S 9 Metal Single (Clear) Yes 1.11 0.23 Y N 40.0ft² 8.0 ft 0 in 1.0 ft 10 in IECC 2012 None
___ 15S 9 Metal Single (Clear) Yes 1.02 0.26 Y N 20.0ft² 8.0 ft 0 in 1.0 ft 10 in IECC 2012 None
___ 16S 10 Metal Single (Clear) Yes 1.11 0.23 Y N 40.0ft² 1.0 ft 6 in 1.0 ft 10 in IECC 2012 None
INFILTRATION
# Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s)
___ 1 Wholehouse Proposed ACH(50) 0.00029 1868 102.46 192.35 0.1248 5.0 All
GARAGE
# Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
___ 1 434 ft² 434 ft² 21 ft 10 ft 5
9/23/2021 12:21:13 AM Page 3EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS
# Mass Type Area Thickness Furniture Fraction Space
___ 1 Default(8 lbs/sq.ft.) 0 ft² 0 ft 0.30 1st Floor
___ 2 Default(8 lbs/sq.ft.) 0 ft² 0 ft 0.30 2nd Floor
HEATING SYSTEM
# System Type Subtype/Speed AHRI # Efficiency Capacity ----Geothermal HeatPump---- Ducts Block
kBtu/hr Entry Power Volt Current
___ 1 Electric Heat Pump Split/Single HSPF: 9.00 34.0 0.00 0.00 0.00 sys#1 1
___ 2 Electric Heat Pump Split/Single HSPF: 8.50 40.0 0.00 0.00 0.00 sys#2 2
COOLING SYSTEM
# System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block
kBtu/hr cfm
___ 1 Central Unit None/Single SEER:16.0 30.0 900 0.75 sys#1 1
___ 2 Central Unit Split/Single SEER:16.0 36.0 1080 0.75 sys#2 2
HOT WATER SYSTEM
# System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length
___ 1 Electric Tankless 1st Floor 0.98 (0.98) 1.00 gal 60 gal 120 deg Standard None 99
Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
System Type length length power Connected Flow Eff
___ 1 No NA NA NA No NA NA NA None
DUCTS
Duct ---------Supply--------- ---------Return--------- Air CFM 25 CFM 25 HVAC #
# Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool
___ 1 1st Floor 8.0 400 ft² 1st Floor 8.0 100 ft² Prop. Leak Free 1st Floor --- --- 0.03 0.50 1 1
___ 2 Attic 8.0 384 ft² Attic 8.0 100 ft² Prop. Leak Free 2nd Floor --- --- 0.03 0.50 2 2
TEMPERATURES
Programable Thermostat: Y Ceiling Fans: N
Cooling [X] Jan [X] Feb [X] Mar [X] Apr [X] May [X] Jun [X] Jul [X] Aug [X] Sep [X] Oct [X] Nov [X] Dec
Heating [X] Jan [X] Feb [X] Mar [X] Apr [X] May [X] Jun [X] Jul [X] Aug [X] Sep [X] Oct [X] Nov [X] Dec
Venting [X] Jan [X] Feb [X] Mar [X] Apr [X] May [X] Jun [X] Jul [X] Aug [X] Sep [X] Oct [X] Nov [X] Dec
Thermostat Schedule: FloridaCode 2014 Hours
Schedule Type 123456789101112
___ Cooling (WD) AM 75 75 75 75 75 75 75 75 75 75 75 75PM 75 75 75 75 75 75 75 75 75 75 75 75
___ Cooling (WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75PM 75 75 75 75 75 75 75 75 75 75 75 75
___ Heating (WD) AM 72 72 72 72 72 72 72 72 72 72 72 72PM 72 72 72 72 72 72 72 72 72 72 72 72
9/23/2021 12:21:13 AM Page 4EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES(Continued)
___ Heating (WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72PM 72 72 72 72 72 72 72 72 72 72 72 72
9/23/2021 12:21:13 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5
Air System Sizing Summary for SCOUTTO RES ZONE #1
Project Name: SCOUTTO RES ZONE #1
Prepared by:51(QJLQHHULQJ,QVSHFWLRQ &RQVWUXFWLRQ,QF
Air System Information
Air System Name SCOUTTO RES ZONE #1
Equipment Class SPLT AHU
Air System Type SZCAV
Number of zones 1
Floor Area 1250.0 ft²
Location FORT PIERCE, Florida
Sizing Calculation Information
Zone and Space Sizing Method:
Zone CFM Sum of space airflow rates
Space CFM Individual peak space loads
Calculation Months Jan to Dec
Sizing Data Calculated
Central Cooling Coil Sizing Data
Total coil load 2.2 Tons
Total coil load 26.4 MBH
Sensible coil load 25.6 MBH
Coil CFM at Jul 1700 1024 CFM
Max block CFM 1024 CFM
Sum of peak zone CFM 1024 CFM
Sensible heat ratio 0.973
ft²/Ton 568.9
BTU/(hr-ft²) 21.1
Water flow @ 10.0 °F rise N/A
Load occurs at Jul 1700
OA DB / WB 89.9 / 76.7 °F
Entering DB / WB 77.3 / 61.9 °F
Leaving DB / WB 54.1 / 52.7 °F
Coil ADP 51.5 °F
Bypass Factor 0.100
Resulting RH 40 %
Design supply temp. 55.0 °F
Zone T-stat Check 0 of 1 OK
Max zone temperature deviation 2.0 °F
Central Heating Coil Sizing Data
Max coil load 9.9 MBH
Coil CFM at Des Htg 1024 CFM
Max coil CFM 1024 CFM
Water flow @ 20.0 °F drop N/A
Load occurs at Des Htg
BTU/(hr-ft²) 7.9
Ent. DB / Lvg DB 69.5 / 78.5 °F
Supply Fan Sizing Data
Actual max CFM 1024 CFM
Standard CFM 1023 CFM
Actual max CFM/ft² 0.82 CFM/ft²
Fan motor BHP 0.21 BHP
Fan motor kW 0.17 kW
Fan static 0.75 in wg
Outdoor Ventilation Air Data
Design airflow CFM 0 CFM
CFM/ft² 0.00 CFM/ft²
CFM/person 0.00 CFM/person
Hourly Analysis Program v4.70 Page 1 of 2
0/22/2021
1:PM
Zone Sizing Summary for SCOUTTO RES ZONE #1
0/22/2021
1:PM
Air System Information
Air System Name SCOUTTO RES ZONE #1
Equipment Class SPLT AHU
Air System Type SZCAV
Number of zones 1
Floor Area 1250.0 ft²
Location FORT PIERCE, Florida
Sizing Calculation Information
Zone and Space Sizing Method:
Zone CFM Sum of space airflow rates
Space CFM Individual peak space loads
Calculation Months Jan to Dec
Sizing Data Calculated
Zone Sizing Data
Maximum Design Minimum Time Maximum Zone
Cooling Air Air of Heating Floor
Sensible Flow Flow Peak Load Area Zone
Zone Name (MBH)(CFM)(CFM)Load (MBH)(ft²)CFM/ft²
Zone 1 19.3 993 993 Jul 1700 10.8 1250.0 0.79
Zone Terminal Sizing Data
No Zone Terminal Sizing Data required for this system.
Space Loads and Airflows
Cooling Time Air Heating Floor
Zone Name /Sensible of Flow Load Area Space
Space Name Mult.(MBH)Load (CFM)(MBH)(ft²)CFM/ft²
Zone 1
SCOUTTO RES ZONE#1 1 19.3 Jul 1700 993 10.8 1250.0 0.79
Hourly Analysis Program v4.70 Page 2 of 2
Project Name: SCOUTTO RES ZONE #1
Prepared by:51(QJLQHHULQJ,QVSHFWLRQ &RQVWUXFWLRQ,QF
Air System Sizing Summary for SCOUTTO RES ZONE #2
0/22/2021 Project Name: SCOUTTO RES ZONE #2
Prepared by: 51(QJLQHHULQJ,QVSHFWLRQ &RQVWUXFWLRQ,QF1:PM
Air System Information
Air System Name SCOUTTO RES ZONE #2
Equipment Class SPLT AHU
Air System Type SZCAV
Number of zones 1
Floor Area 1250.0 ft²
Location FORT PIERCE, Florida
Sizing Calculation Information
Zone and Space Sizing Method:
Zone CFM Sum of space airflow rates
Space CFM Individual peak space loads
Calculation Months Jan to Dec
Sizing Data Calculated
Central Cooling Coil Sizing Data
Total coil load 2.6 Tons
Total coil load 30.9 MBH
Sensible coil load 30.1 MBH
Coil CFM at Jul 1700 1204 CFM
Max block CFM 1204 CFM
Sum of peak zone CFM 1204 CFM
Sensible heat ratio 0.973
ft²/Ton 485.4
BTU/(hr-ft²) 24.7
Water flow @ 10.0 °F rise N/A
Load occurs at Jul 1700
OA DB / WB 89.9 / 76.7 °F
Entering DB / WB 77.3 / 61.8 °F
Leaving DB / WB 54.1 / 52.7 °F
Coil ADP 51.6 °F
Bypass Factor 0.100
Resulting RH 41 %
Design supply temp. 55.0 °F
Zone T-stat Check 0 of 1 OK
Max zone temperature deviation 2.0 °F
Central Heating Coil Sizing Data
Max coil load 10.8 MBH
Coil CFM at Des Htg 1204 CFM
Max coil CFM 1204 CFM
Water flow @ 20.0 °F drop N/A
Load occurs at Des Htg
BTU/(hr-ft²) 8.7
Ent. DB / Lvg DB 69.5 / 77.8 °F
Supply Fan Sizing Data
Actual max CFM 1204 CFM
Standard CFM 1204 CFM
Actual max CFM/ft² 0.96 CFM/ft²
Fan motor BHP 0.25 BHP
Fan motor kW 0.20 kW
Fan static 0.75 in wg
Outdoor Ventilation Air Data
Design airflow CFM 0 CFM
CFM/ft² 0.00 CFM/ft²
CFM/person 0.00 CFM/person
Hourly Analysis Program v4.70 Page 1 of 2
Zone Sizing Summary for SCOUTTO RES ZONE #2
Air System Information
Air System Name SCOUTTO RES ZONE #2
Equipment Class SPLT AHU
Air System Type SZCAV
Number of zones 1
Floor Area 1250.0 ft²
Location FORT PIERCE, Florida
Sizing Calculation Information
Zone and Space Sizing Method:
Zone CFM Sum of space airflow rates
Space CFM Individual peak space loads
Calculation Months Jan to Dec
Sizing Data Calculated
Zone Sizing Data
Maximum Design Minimum Time Maximum Zone
Cooling Air Air of Heating Floor
Sensible Flow Flow Peak Load Area Zone
Zone Name (MBH)(CFM)(CFM)Load (MBH)(ft²)CFM/ft²
Zone 1 22.7 1168 1168 Jul 1700 12.2 1250.0 0.93
Zone Terminal Sizing Data
No Zone Terminal Sizing Data required for this system.
Space Loads and Airflows
Cooling Time Air Heating Floor
Zone Name /Sensible of Flow Load Area Space
Space Name Mult.(MBH)Load (CFM)(MBH)(ft²)CFM/ft²
Zone 1
SCOUTTO RES ZONE#2 1 22.7 Jul 1700 1168 12.2 1250.0 0.93
Hourly Analysis Program v4.70 Page 2 of 2
0/22/2021
1:PM
Project Name: SCOUTTO RES ZONE #2
Prepared by: 51(QJLQHHULQJ,QVSHFWLRQ &RQVWUXFWLRQ,QF