Loading...
HomeMy WebLinkAboutNOA- PLANTATION ROOF TILE NOA No.: 20-1019.02 Expiration Date: 12/08/25 Approval Date: 11/19/20 Page 1 of 7 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Plantation Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA #19-1021.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino NOA No.: 20-1019.02 Expiration Date: 12/08/25 Approval Date: 11/19/20 Page 2 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Test Specifications Product Description Plantation Tile Length: 16½″ Width: 13″ TAS 112 Flat profile concrete roof tile, Type 3a Interlocking, Class III; for direct deck or battened nail-on, mortar or adhesive set applications. Trim Pieces L = varies W = varies Varying thickness TAS 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 2.1. MANUFACTURING LOCATION 1. Okeechobee, FL 2.2 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description Manufacturer (With Current NOA) ICP Adhesives Polyset® AH-160 Two component polyurethane foam adhesive. ICP Adhesives and Sealants, Inc. TILE BONDTM Roof Tile Adhesive Single component polyurethane foam roof tile adhesive. The Dow Chemical Company DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive Two component polyurethane foam adhesive. Dap Foam, Inc. Quikrete” Roof Tile Mortar, FL-15 Premixed, pre-bagged gray roof tile mortar. The Quikrete Companies, Inc. NOA No.: 20-1019.02 Expiration Date: 12/08/25 Approval Date: 11/19/20 Page 3 of 7 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date American Test Lab of South Florida RT0624.05-14 RT0817.07-20 TAS 112 TAS 112 07/03/14 08/14/20 Redland Technologies 7161-03 Appendix III Static Uplift Testing PA 102 & PA 102(A) Dec. 1991 The Center for Applied Engineering, Inc. 94-060B 94-084 Static Uplift Testing PA 101 (Adhesive Set) (Mortar Set) March 1994 May 1994 Redland Technologies 7161-03 Appendix II Wind Tunnel Testing PA 108 (Nail-On) Dec. 1991 Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing PA 108 (Nail-On) Aug. 1994 Redland Technologies P0631-01 Wind Tunnel Testing PA 108 (Mortar Set) July 1994 Redland Technologies P0402 Withdrawal Resistance Testing of screw vs. smooth shank nails Sept. 1993 The Center for Applied Engineering, Inc. Project No. 307025 Test #MDC-76 Wind Driven Rain PA 100 Oct. 1994 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 April 1999 Walker Engineering, Inc. Calculations 25-7183 25-7094 25-7496 March 1995 February 1996 April 1996 Walker Engineering, Inc. Calculations 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 December 1996 Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Farabaugh Engineering and Testing Inc. T295-11 TAS-108 10/05/11 Farabaugh Engineering and Testing Inc. T306-11 TAS-108 10/04/11 Farabaugh Engineering and Testing Inc. T279-11 TAS-108 09/23/11 PRI Construction Material Technologies DAPF-004-02-08 DAPF-004-02-09 DAPF-004-02-10 TAS 101 Static Uplift Resistance Adhesive Set 07/26/18 07/26/18 07/26/18 NOA No.: 20-1019.02 Expiration Date: 12/08/25 Approval Date: 11/19/20 Page 4 of 7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix ‘A’. Such testing shall be submitted to the Miami-Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 Minimum 4/12 slope requirement for mechanically attached tiles. 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.8 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 4. INSTALLATION 4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (l x w ) Tile Profile Weight-W (lbf) Length-l (ft) Width-w (ft) Plantation Tile 11.6 1.375 1.08 Table 2: Aerodynamic Multipliers -  (ft3) Tile Profile  (ft3) Batten Application  (ft3) Direct Deck Application Plantation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - Mg (ft.-lbf) Tile Profile 2”: 12" 3": 12" 4": 12" 5": 12" 6": 12" Greater than 7": 12" Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Plantation Tile N/A 7.91 N/A 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 NOA No.: 20-1019.02 Expiration Date: 12/08/25 Approval Date: 11/19/20 Page 5 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Nail-On Systems Tile Profile Fastener Type Direct Deck (Min 15/32” plywood) Direct Deck (Min. 19/32” plywood) Battens Plantation Tile 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails1 50.3 65.5 48.3 1 Installation with a 4" tile headlap and fasteners are located a minimum of 2½“from the head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive2 2 See manufactures component approval for installation requirements. 3 The Dow Chemical Co. TILE BONDTM Roof Tile Adhesive weight per patty 13.9 grams. 31.3 4 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two-Component weight per patty 8 grams. 31.3 5 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 8 grams. 45 NOA No.: 20-1019.02 Expiration Date: 12/08/25 Approval Date: 11/19/20 Page 6 of 7 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive6 6 See manufactures component approval for installation requirements. 7 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two-Component weight per patty 45 grams. 118.9 8 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two-Component weight per patty 24 grams 40.4 9 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 45 grams. 73 10 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 24 grams 48 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Plantation Tile Mortar Set6 39.0 See specific mortar manufacturer’s Notice of Acceptance. 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami-Dade County Product Control Approved". OR BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 20-1019.02 Expiration Date: 12/08/25 Approval Date: 11/19/20 Page 7 of 7 PROFILE DRAWING BORAL PLANTATION FLAT CONCRETE TILE 1 3 " 16 1/2" END OF THIS ACCEPTANCE