NOA No.: 20-1019.02
Expiration Date: 12/08/25
Approval Date: 11/19/20
Page 1 of 7
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER -Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Plantation Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA #19-1021.02 and consists of pages 1 through 7.
The submitted documentation was reviewed by Freddy Semino
NOA No.: 20-1019.02
Expiration Date: 12/08/25
Approval Date: 11/19/20
Page 2 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Boral Plantation Concrete Roof Tile, as manufactured by Boral Roofing, LLC
in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in locations where the pressure requirements, as determined
by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS
127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based
system.
2. PRODUCT DESCRIPTION
Manufactured by
Applicant
Dimensions
Test
Specifications
Product
Description
Plantation Tile Length: 16½″
Width: 13″
TAS 112
Flat profile concrete roof tile,
Type 3a Interlocking, Class III;
for direct deck or battened nail-on,
mortar or adhesive set applications.
Trim Pieces L = varies
W = varies
Varying thickness
TAS 112 Accessory trim, concrete roof pieces for
use at hips, rakes, ridges and valley
terminations. Manufactured for each tile
profile.
2.1. MANUFACTURING LOCATION
1. Okeechobee, FL
2.2 PRODUCTS MANUFACTURED BY OTHERS
Product Name Product Description Manufacturer
(With Current NOA)
ICP Adhesives Polyset® AH-160
Two component polyurethane
foam adhesive.
ICP Adhesives and Sealants, Inc.
TILE BONDTM Roof Tile Adhesive Single component polyurethane
foam roof tile adhesive.
The Dow Chemical Company
DAP Foam Touch N Seal
StormBond® 2 Roof Tile Adhesive
Two component polyurethane
foam adhesive.
Dap Foam, Inc.
Quikrete” Roof Tile Mortar, FL-15 Premixed, pre-bagged gray roof tile
mortar.
The Quikrete Companies, Inc.
NOA No.: 20-1019.02
Expiration Date: 12/08/25
Approval Date: 11/19/20
Page 3 of 7
2.3 SUBMITTED EVIDENCE:
Test Agency Test Identifier
Test Name/Report Date
American Test Lab of South
Florida
RT0624.05-14
RT0817.07-20
TAS 112
TAS 112
07/03/14
08/14/20
Redland Technologies 7161-03
Appendix III
Static Uplift Testing
PA 102 & PA 102(A)
Dec. 1991
The Center for Applied
Engineering, Inc.
94-060B
94-084
Static Uplift Testing
PA 101 (Adhesive Set)
(Mortar Set)
March 1994
May 1994
Redland Technologies 7161-03
Appendix II
Wind Tunnel Testing
PA 108 (Nail-On)
Dec. 1991
Redland Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing
PA 108 (Nail-On)
Aug. 1994
Redland Technologies P0631-01 Wind Tunnel Testing
PA 108 (Mortar Set)
July 1994
Redland Technologies P0402 Withdrawal Resistance Testing of
screw vs. smooth shank nails
Sept. 1993
The Center for Applied
Engineering, Inc.
Project No. 307025
Test #MDC-76
Wind Driven Rain
PA 100
Oct. 1994
Walker Engineering, Inc.
Calculations Aerodynamic Multiplier March 1999
April 1999
Walker Engineering, Inc. Calculations 25-7183
25-7094
25-7496
March 1995
February 1996
April 1996
Walker Engineering, Inc. Calculations 25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
December 1996
Walker Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999
Farabaugh Engineering and
Testing Inc.
T295-11 TAS-108 10/05/11
Farabaugh Engineering and
Testing Inc.
T306-11 TAS-108 10/04/11
Farabaugh Engineering and
Testing Inc.
T279-11 TAS-108 09/23/11
PRI Construction Material
Technologies
DAPF-004-02-08
DAPF-004-02-09
DAPF-004-02-10
TAS 101
Static Uplift Resistance
Adhesive Set
07/26/18
07/26/18
07/26/18
NOA No.: 20-1019.02
Expiration Date: 12/08/25
Approval Date: 11/19/20
Page 4 of 7
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix ‘A’. Such testing shall be submitted to the Miami-Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 Minimum 4/12 slope requirement for mechanically attached tiles.
3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.8 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (l x w )
Tile Profile
Weight-W (lbf) Length-l (ft) Width-w (ft)
Plantation Tile 11.6 1.375 1.08
Table 2: Aerodynamic Multipliers - (ft3)
Tile
Profile (ft3)
Batten Application
(ft3)
Direct Deck Application
Plantation Tile 0.267 0.289
Table 3: Restoring Moments due to Gravity - Mg (ft.-lbf)
Tile
Profile
2”: 12"
3": 12"
4": 12"
5": 12"
6": 12"
Greater than
7": 12"
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
Battens Direct
Deck
Plantation
Tile
N/A 7.91 N/A 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04
NOA No.: 20-1019.02
Expiration Date: 12/08/25
Approval Date: 11/19/20
Page 5 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
For Nail-On Systems
Tile
Profile
Fastener Type Direct Deck
(Min 15/32”
plywood)
Direct Deck
(Min. 19/32”
plywood)
Battens
Plantation Tile 2-10d Ring Shank
Nails
30.9 38.1 17.2
1-10d Smooth or
Screw Shank Nail
7.3 9.8 4.9
2-10d Smooth or
Screw Shank Nails
14.0 18.8 7.4
1 #8 Screw 30.8 30.8 18.2
2 #8 Screw 51.7 51.7 24.4
1-10d Smooth or
Screw Shank Nail
(Field Clip)
24.3 24.3 24.2
1-10d Smooth or
Screw Shank Nail
(Eave Clip)
19.0 19.0 22.1
2-10d Smooth or
Screw Shank Nails
(Field Clip)
35.5 35.5 34.8
2-10d Smooth or
Screw Shank Nails
(Eave Clip)
31.9 31.9 32.2
2-10d Ring Shank
Nails1
50.3 65.5 48.3
1 Installation with a 4" tile headlap and fasteners are located a minimum of 2½“from the head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
For Two Patty Adhesive Set Systems
Tile Profile
Tile Application Minimum Attachment
Resistance
Plantation Tile Adhesive2
2 See manufactures component approval for installation requirements.
3 The Dow Chemical Co. TILE BONDTM Roof Tile Adhesive weight per patty 13.9 grams. 31.3
4 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two-Component weight per patty 8 grams. 31.3
5 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 8 grams. 45
NOA No.: 20-1019.02
Expiration Date: 12/08/25
Approval Date: 11/19/20
Page 6 of 7
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
For Single Patty Adhesive Set Systems
Tile Profile
Tile Application Minimum Attachment Resistance
Plantation Tile Adhesive6
6 See manufactures component approval for installation requirements.
7 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two-Component weight per patty 45 grams. 118.9
8 ICP Adhesive and Sealants, Inc. ICP Adhesve Polyset® AH-160 Two-Component weight per patty 24 grams 40.4
9 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 45 grams. 73
10 DAP Foam Touch N Seal StormBond® 2 Roof Tile Adhesive weight per paddy 24 grams 48
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mortar Set Systems
Tile Profile
Tile Application Attachment
Resistance
Plantation Tile Mortar Set6 39.0
See specific mortar manufacturer’s Notice of Acceptance.
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami-Dade County Product Control Approved".
OR
BORAL PLANTATION ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No.: 20-1019.02
Expiration Date: 12/08/25
Approval Date: 11/19/20
Page 7 of 7
PROFILE DRAWING
BORAL PLANTATION FLAT CONCRETE TILE
1 3 "
16 1/2"
END OF THIS ACCEPTANCE