HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETZ: LULL �-)I ST. LUCIE { ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Low Slope Application Required Sections of the Permit Application Form A. B, C Prescriptive BUR-RAS 150 A, B, C Asphaltic Shin I A, B, D (Concrete or Clay Tile A, B, D, E. Metal Roofs T A, B. Attachments Required See List Below 1,2,3,4,6,6,7 ~f 2�4 5,6 7 1.2.4.5.6.7 1,2,3,4,A,6,7 Wood Shingles and A. B, D 1,2,4,6,6,7 Shakes _ Other As Applicable 1,2,3,4,6,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RA5128 4. Other Component of Product Approval 5, Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFebzl Rev Feb 18, 2021 ST. LUCIE Section A (General Information) Master Permit No. Process No. .�,/ pe4af &-( C=x�elehs Contractors NameTkat �tlf+'h� �S S I�� License A T Job Address 13C/13 Ai &J"X20 %MIKA TE'-1• Al ROOF CATEGORY O Low Slope O Mechanically Fastened Tile B<Ortar/Adhesive Set Tiles Asphaltic Shingles O Metal Panel/Shingles OWood Shingles/Shakes 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE ❑ New roof ❑ Repair O Maintenance Reroofing ❑Recovering ROOF SYSTEM INFORMATION /� ! Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) to3� Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUC Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: _ Zone 2: _Zone 3: _ Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Mate al: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1'_" oc @ Lap, # Rows— @ 00 Zone 1—" oc @ Lap, p Rows — @ "oc Zone 2_" oc @ Lap, If Rows — @ " oc Zone 3_" oc @ Lap, if Rows— @ —" o0 Number of Fasteners Per Insulation Board Zone 1'pZone 1wZone 2:—Zone 3:_ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, ounterflashing, Coping, Etc. dicate: Mean Roof Height, Parapet Height, Height of Base lashing, Co onent Material, Material' Thickness, Fastener ype, Fast a Spacing or Submit Manufacturers Details that mply wi R 11 and Chapter 16. FT. FT. Parapet Height Mean Roof Height ST. LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer: Notice of Acceptance Number: 1y-1o/9. o} Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-- 40Zone 2e:' Zone 2n:ZLO_'bone 2r:—1 UV7one 3e:--IJL*one 3r Deck Type: C 7TypeUnderlayment Arwi '3d't1-wie- /Ti-on:ur+t t"Sli 30 Ptt(¢ `�� Roof Sbpe: 12sulation: Fire Barrier: RidgeVerdl Hon? Fastener Type&Spacing: fir} Mean Roof Height: I Adhesive Type: I a Ph VC -to OW /W VFo&M Type Cap Sheet Ai Roof Covering: dw,s.an Qou.F Tr) �\ Type 8 Sim Drip Edge: ace 3� 3 Co u f ua4w'4-1 ST. LUCIE Section E (Tile Calculations) For Moment based the systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the M, values are greater than or equal to the M, values, for each area of the roof. then the the attachment method is acceptable. Method 1'Moment Bas d Tile Calculations Per RAS 12T (Zone 1: _ x a _ - Mg: = M,_ Product Approval M. (Zone Ze: _ x I - Mg: - Product Approval M, (Zone 2n: _ x). _ - Mg' Product Approval (Zone 2: _ x 1, - M M Product Approval Mf (Zone 3e: _x2. = J- M*. Product ApprovalM, (Zone 3r: -xl-= -I- -=Mo- Product Approval M, Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below-28-Product Approval M• 3/, 3 Mean Roof Height Roof Slope M, required Moment Resistance* 15' 20' 25, 30' 1 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 ~ 4:12 5:12 32.2 34.4 30.4 32.2 28.4 30.1 _ 36.0 33.8 31.6 37.4 39.8 35.1 37.3 34.9 32.8 -j 6:12 7:12 26.4 24.4 28.0 29.4 30.5 32.4 30.0 25.9 27.1 28.2 'Must be used In conjunction with a list of moment based the systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the F' values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L= x W:=W-W:COS =Fn Product Approval F', (Zone 2e: x L_=x W:=r =F . Product Approval F'. (Zone 2n: x L_=x W:=r ,2 Product Approval F'. (Zone 2r: _x L_=x W:= =F,2 Product Approval F'. (Zone 3e: _x L=x W:=r=F,s._ Product Approval F', (Zone 3r: _x L= x W:=) -W:_ cos r_=F,s,_ Product Approval F', Where to Obtain Information Description Symbol Where to find From applicable table in RAS 127 or by an engindering analysis Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r I prepared by PE based on ASCE 7 Mean Roof Height H !lob Site Roof Slope Aerodynamic Multiplier s I Product Approval Restoring Moment due to Gravity Mr Product Approval Attachment Resistance Me . Product Approval Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance F, Calculated Average TiIe Weight IN Product Approval L = length W = width Product Approval Tile Dimensions All calculations must be submitted to the building official at the time of permit application.