HomeMy WebLinkAboutELECTRIC WATER HEATERResidential Electric
water Professional Classic Water Heaters
11
The new degree of comfort'
Professional Classic® electric water heaters are
engineered for longer life - resistored heating
elements and premium grade anode rod
Efficiency
•.90-.93UEF
• Isolated tank design reduces
conductive heat loss
• Resistored copper upper element and
resistored Lifeguard" stainless steel
lower element to prolong anode rod
and tank life
Performance
• FHR: 45 - 67 gallons, based on gallon
capacity
• Recovery: 21 GPH at a 900 F rise
System Sentinel
(Available on selected models)
• Exclusive diagnostic system with
glowing LEDs that verify heating
element operation. LEDs pin point the
exact location of functioning or non-
functioning heating elements
Longer Life
• Premium grade anode rod provides
long-lasting tank protection
Features
• Electric junction box located above
heating elements for easy installation
• Over -temperature protector cuts
off power in excess temperature
situations
• Automatic thermostat keeps water at
desired temperature
Plus...
• Rheemi tank lining resists
corrosion and prolongs tank life
• EverKli self cleaning device fights
harmful sediment build-up with a
high -velocity spiraling water stream -
helps operating efficiency by saving
energy, money and improving tank life
:ri
• Enhanced -flaw brass drain valve
• Temperature and pressure relief valve
included
• Models are compliant to HUD
Standards for manufactured housing
and modular construction
• Low lead compliant
Warranty
• 6-Year limited tank and parts
warranty'
• With Protection Plus"' the 6-year limited
tank warranty becomes 10-year
`See Residential warranty Certificate for complete
information
Units meet or exceed ANSI requirements and have
oeen tested according to the AHRI Operations
Manual and D.O.E. procedures. Units inset or
exceed the energy efficarcy requirements of
NAECA, ASHRAE standard 90, ICC Code and all
state erergy efficiency perforrnance Criteria,
ii � r- I 1 -A I 1 e ... 1'L_ .
9
Professional Classic
19.9 to 55-Gallon Capacities
240 Volt AC/Single Phase
Double and Single Element Models
Electric
See specifications chart on back.
PRINTED IN LIA.A. 0%/FO WP I Ui W. Vi KH N Nov, I,l
CK_
r„
The now degree of comfort"
Professional Classic' Specifications
Residential Electric
Water Professional Classic Water Heaters
DESCRIPTION
T
Y NOMINAL RATED
P GALLON GALLON MODEL
E CAPACITY CAPACITY NUMBER
_
FEATURES
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
-- - -�r-
TANK HEIGHT TO APPROX.
HEIGHT WATER CONN. DIAMETER 9HfPWT.
A B C {Les.l
47-1/2 50-3/8 19 92
ENERGY INFO.
11NIFORM
ENERGY
FACTOR
111EFI
LIEF
FIRST HOUR
RATING
O.P.H.
46
RECOVERY
IN G.P.H.
90'FRISE
21
Tell
30
27
PROE30 T2 RH951
0.92
Tall
40
36
PROE40 T2 RH951
55
21
60-3/4
63-5/8
19-114
109
0.93
Tall
50
45
PROE50 T2 RH951
53
21
58-5/8
61-5/8
20.1/4
121
0.93
Tall
55
55
PROE55 T2 RH94r
72
21
57
59-3/4
22-1 /4
128
0.92
Mad.
30
27
PROE30M2RH95r
45
21
37-1/2
40-1/2
20-1/4
92
0.90
Mod.
40
36
PROE40 M2 RH95'
55
21
48-1/4
50-1/2
20-1/4
106
0.93
Med.
50
45
PROE50 M2 RH95'
62
21
4B
50-1/2
23
102
0.93
Short
19.9
-
PROE20 S2 RH
-
21
31-1/2
31-1/2
17
62
-
Short
28
25
PROE28 S2 RH95
45
21
30
31-1/8
23
95
0.92
Short
30
27
PROE30 S2 RH95 B"
46
21
30-116
32
19-3/4
95
0.92
Short
36
33
PROE36 52 RH95
46
21
31-1/2
33
24-1/4
118
0.92
Short
38
35
PROE38 S2 RH95 B'*
51
21
31-1/2
32-58
23
108
0.92
Short 1
47
43
PROE4732 RH95
54
21 i
32
34
26-1/4
149
0.93
Uniform Energy Factor and rated gallon capaerly Wsed on Department of Energy OOEi req,; .�"..;..•sI.
t System Sentinel optional. Add ECt to the and of the model number. System Sentinel not available on single
element models, available on dual element models only. System Sentinel not available in excess of 5 kW on
208 V modals.
" Insidation b:anket re%shad to achieve UFF ralue. Water heater d eris"o s prw to Instating ". LlItNI blame.. Rlanket is
Miuded with water boater.
• Heaters hxnnhad wNh standard 243 volt AC. sire phase non-smxltanaa.s wwg, and 4,W war oper and lkmA. hPat11y
elarnents.
• If heating elements of different wattages than those shown are demanded by zone requirements, they must be
specifically requested.
• Sirgfe element rnoclefs ava-labia on spocd [color (60" max.}, SubsMiute r1- tor'2' n moclat number.
• Spomc Wir rxi Gptlon,s - A limited r1 moff at special wiring optrxhs are ava0b e. Consult factory for price and avaAat4ty.
• AN modes aquipped with hew traps.
Recovery = wattage12.42 x temp. rlBe `1:
Example: 450M = 21 GPH
2.42 x 90`
Recovery calc,laticns used are tmseo` On 4500 watt alanxarts used In non-smultaneam operation.
8.1
HOT
WATER COLD
CONNECTION WATER
RELIEF VALVE I� CONNECTI
CONNECTION ANODE
ROD
C
DIAMETER
;I o
WATER CONNECTIONS ALL 314" N.P.T.
In keeping wide its policy of continuous progress and product improvement, Rheem reserves the right to make changes without north-e.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100
Roswell. Georgia 30076 • www.rheem.com
PRINTED IN D.B.A. 071ZU WP FORM NO, PROS Rif N Rev. 10