HomeMy WebLinkAboutAPPROVED, Owens Corning Shingle Product ApprovalBCIS Home I Login User Registration Hot Topics ! Submit Surcharge Stabs & Facts Publications { Contact Us i BCIS Site Map Links Search
b
a
Product Approval
r4 USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL10674-R16
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL10674 R16 COI 2020 01 COI NIEMINEN.pd
Standard
ASTM D1970
ASTM D3161
ASTM D3462
ASTM D7158
Year
2015
2016
2010
2019
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
12/11/2020
Date Validated
12/17/2020
Date Pending FBC Approval
12/26/2020
Date Approved
02/09/2021
FL # Model, Number or Name
10674.1 Owens Corning Asphalt Roofing
Shingles and Starters
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER, Section 5.
Description
3-tab, 4-tab, laminated, starter and hip & ridge shingles
Installation Instructions
FL10674 R16 II 2020 12 11 FINAL ER OC ASPHALT
SHINGLES FL10674-R16.pd
Verified By: Robert J. M. Nieminen PE - 59166
Created by Independent Third Party: Yes
Evaluation Reports
FL10674 R16 AE 2020 12 11 FINAL ER OC ASPHALT
SHINGLES FL10674-R16.
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
® ®F978 eCAecA
Credit Card
Safe
MEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Owens Corning Evaluation Report 037940.02.12-1111
One Owens Corning Parkway FL10674-1116
Toledo, OH 43659
(740) 404-7829
Date of Issuance: 02/06/2012
Revision 11: 12/11/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7' Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO I etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen P.E. :3, ,:'tr{*? The facsimile seal appearing was authorized by Robert
,,��",,+ y,• r' Nieminen, P.E. on 12/11/2020. This does not serve as an
Florida Registration No. 59156, Florida DCA ANE1983 "`:'rd +'ri,;; �L s*'`" electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2018 NEMO ETC, LLC
ONEMOletc.
ROOFING SYSTEMS EVALUATION:
SCOPE:1.
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 711 Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
STANDARDS:2.
Section Property Standard Year
1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015
1507.2.5, R905.2.4 Material standard ASTM D3462 2010
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2019
3. REFERENCES:
Entity Examination Reference Date
Owens Corning Declaration Equivalency Declaration 08/06/2019
PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC (TST9628) Physical Properties Classification letter 02/13/2014
UL LLC (TST9628) Physical Properties Classification letter 10/02/2015
PRI (QUA9110) Quality Control Service Confirmation 04/05/2020
PRI (QUA9110) Quality Control Florida BCIS Current
PRODUCT DESCRIPTION:
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type
Product
Plant
Materials)
Description
Standard
Starter Strip Shingle
H-TX, OR
Starter Strip Plus
MN, OR
Accessory
ASTM D3462
starter strips for asphalt roof shingles
SRS TopShield Starter
MN, OR
Starter
Strips
Starter Shingle Roll
NH
ASTM D1970
mineral -surfaced, fiberglass -reinforced,
self -adhering SBS modified bitumen starter
Supreme'
GA, CA, CO, I -TX, NJ, OH,
ASTM D3462
fiberglass reinforced 3-tab asphalt
TN, OR, IL
roof shingles
Berkshire'
MN
ASTM D3462
fiberglass reinforced, 4-tab asphalt
roof shingles
Duration' Premium
CA, OR
Duration' Premium COOL
CA
Asphalt
TruDefinition' Duration'
Shingles
IN, CA, CO, I -TX, FL, NJ, OH,
TruDefinition® Duration®
Designer Color Collection
MN, OR, GA, IL, TN
ASTM D3462
fiberglass reinforced, laminated
asphalt roof shingles
Oakridge
GA, IN, CA, CO, H-TX, I -TX,
FL, NJ OH, TN
TruDefinition' Oakridge'
H-TX, I -TX
WeatherGuard' HP
TN
NEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate ofAuthorization #32455 7- EDITION (2020) FBC NON-HVH2 EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 2 of 10
ONEM01aft
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type
Product
Plants
(�
Material
Standard
Description
Berkshire® Hip and Ridge
Shingles with Sealant
MN
DuraRidge® Hip and Ridge
Hip and
Ridge
Shingles with Sealant
MN
ASTM D3462
fiberglass reinforced, hip and ridge
Shingles
asphalt roof shingles
ProEdge®
GA, CA, OH, OR
WeatherGuard` HP Hip and
Ridge Shingles
TN
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction,
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications
TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES
I Product I FBC Table 1507.2.7.1 or R905.2.6.1
Supreme'
Berkshire'
Duration® Premium
Duration® Premium COOL
TruDefinition® Duration®
TruDefinition® Duration® Designer Color Collection
Oakridge®
TruDefinition® Oakridge
WeatherGuard® HP
5.5.1 Classification by ASTM D7158:
ASTM D3161(F) & ASTM D7158(H)
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
NEMO ETC, LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization #32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 3 of 10
ONEM01atc-
TABLE 213: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP & RIDGE
Type
Product
FBC Table 1507.2.7.1 or R905.2.6.1
Starter Strips
Starter Strip Shingle
ASTM D3161, Class F
Starter Strip Plus
SRS TopShield Starter
Hip & Ridge
Shingles
Berkshire' Hip and Ridge Shingles with Sealant
ASTM D3161, Class F
DuraRidge° Hip and Ridge Shingles with Sealant
ProEdge®
WeatherGuarde HP Hip and Ridge Shingles
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Felt undedayment —Deck
Seff-adhered
weathertake
t underlayment
Drip edge Drip edge
Nails located
2'=3" from eave
Install first Sell -sealing adhesive
Starter Strip positioned along eave
shingle with
V removed
Starter Strip shingle overhangs eaves and rakes
Felt undedayment Deck SefYadhered
Weatheri.oek_•
uaderlaymont
Drip edge
Drip --
edge
_ Naielocated
2"-3" from eave
Instal first Starter Strip Mus SsfaeaBngadhesive
with 6'removed - Positioned along save
Starter Strip Plus overhangs oaves and rakes 114"-3/4'
Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus
NEMO ETC, LLC Evaluation Report 037940.02.12-R11
Certificate of Authorization 432455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 4 of 10
6.2.2
N EMO I etc.
Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Self-sealing adhesive
positioned along eaves
Figure 3: Starter Shingle Roll
Underlayment
Drip edge
Starter Shingle Roll adhered
directly to underlayment and
primed drip edge
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
Normal Mansard or Area pare
Wind Areas High Wind desvanes y
Area pare vientos normales Areas vientos fuertes
5" Exposure
Exposfcion
Figure 4: Minimum Nailing, Supreme
(Standard Size)
Normal
Wind Areas
Area pare vientos normales
V (A)
12 12 1
5 5/8" Exposure
Exposicidn
Mansard or Area pare
High Wind desvanes y
Areas vientos fuertes
Figure 5: Minimum Nailing, Supreme
(Metric Size)
NEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization #32455 7T" EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 5 of 10
6.3.1.2 Berkshire®:
Sealant strip
La lira de sellador
81! W. 9 Yt' 9112, 8 Yt'
ill
Figure 6: 5-Nail Pattern, Berkshire
ONEMOjetc.
Figure 7: 6-Nail Pattern, Berkshire
Sealant strip
La lira de sellador
• 4 ------- ► • •-) • 4--) •
1
Asphaft roofing cement
Cemento de techo de astafto
Figure 8: Mansard or Steep Slope Pattern, Berkshire
NEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 6 of 10
ONEMOjetc.
6.3.1.3 Duration® Premium, TruDefinition® Duration, Duration® Premium COOL & TruDefinition® Duration® Designer Color
Collection:
Figure 9: Standard 4-Nail Pattern, Duration
6-Nail Fastening Pattern
SureNail® fastening area width
Nail, Typical
t" 12" 12" 1>
W .—cp x.e suu; a • �i. s ae.,.a a • o .ns coma,u sup F+a a i
6-1/8" 5-518"
eaPF.1
-
Figure 10: 6-Nail Pattern, Duration
Fastening for Slopes Greater Than 21:12
SureNail® fastening area width
Nail, Typical
1 12" 1211 1,
fT+'ens Comirp S..'W a• .�1 am$ BUluto) suantp • ori'en5 Cami.lp StueNad� •
6.1/8" 5-518"
e%pusu.e
�f2„
Four 1" Spots of Asphalt Roofing Cement
Figure 11: Mansard or Steep Slope Pattern, Duration
NEMO ETC, LLC Evaluation Report 037940.02.12-1131
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 7 of 10
6.3.1.4 TruDefinition®Oakridee®, Oakridee®:
4 Nail Pattern
Esquema con 4 clavos
1"
. T`�7 F
5518" Exposure Nails
Exposici6ndo55/8puig. Clauos
1*— 12" —
5 5/8" Exposure
Exposition de 5 5/8 ping.
Figure 12: Standard 4-Nail Pattern, Oakridge
6 Nail Pattern
Esquema con S clavos
5 5/8" . ,r_.,
Exposition de 5618 pulp.
fONEMOjetc.
Gtavos a aia Cxposute
Exposition de 5 5/8 pulg.
Figure 13: 6-Nail Pattern, Oakridge
Fastening for Slopes Greater Than 21:12
SureNail® fastening area width
Nail, Typical
1. 12" 1 12" 11.
preps Cominp 5uret.:.i' • fle`lainS Ourcuo�swn�p • Oxvus Comiiq SweNaAfi •
6.1l8" 5-5l8"
expose
Four 1" Spots of Asphalt Roofing Cement i
6.3.1.5 WeatherGuard® HP:
Figure 14: Mansard or Steep -Slope Pattern, Oakridge
6 Nal Pattern
Esquema con 6 clavos Nail 6118` from bottom
of shingle
Clove5 618' Exposure 6 Fasteners parse arse a 611$ }edit de
ExposicM 5 518 ptdg. 6 sWetadores pinferior de la teja
12' 1 1
,A�
NA
am
EVo�nde 5 5B puS . Expeddin de 6 51 p*.
Figure 1S: 6-Nail Pattern, WeatherGuard HP
Four 1' Spots of Asphah Roof Cement
Cuatro pun tos de cemawo de techo de asfatto de ? putgada
Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
NEW ETC, LLC Evaluation Report 037940.02.12-R11
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1.10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 8 of 10
6.4 HIP AND RIDGE SHINGLES: ONEMO I etc.
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire® Hip and Ridge Shingles with Sealant and DuraRidge° Hip and Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
➢ WeatherGuard® HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1 Berkshire® Hip and Ridge with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant:
Fig. A
Prevailing Wind Direction
�— Direccidn del viento predominante
Cl
6' Ezpowre
Erposidoe de 94
Z\�A
Figure 17: Isometric View, Berkshire and DuraRidge
6.4.1.2 WeatherGuard® HP Hip and Ridge Shingles:
Fig. A q
Prevailing Wind
E- Dlredlon p
0
Nails
1 I
A I
p 1 I
I I I I
A I 1 I I
I I i I
T V V W
S -�
Exposure
Fig. B
Top View
Vista superior
Nail
Clavo
1 12"
Hlt„
1��
IH
25/a"
I
• Owens ComirngSureNail` •
I
I�
8
yi u
�I
I
I
Figure 18: Plan View, Berkshire and DuraRidge
Fig. C Hip & Ridge Shingle Fastening
Top V levr
Nails Nails
T"
2" 2"
1" 1"
i .•
g, Exposure
12
Figure 19: Isometric View, WeatherGuard HP Hip and Ridge Figure 20: Plan View, WeatherGuard HP Hip and Ridge
NEMO ETC, LLC Evaluation Report 037940.02.12-1111
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision li: 12/11/2020
Page 9 of 10
6.4.1.3 ProEdee®:
Prevailing
Wind Direction Sealant Strip .
6" Exposure
Fasten 71h'
Cover Exposed
Fasteners with
Roof Cement
Figure 21: Isometric View, ProEdge
ONEMOletc.
Standard —f1"►
Fastening
Pattern
12' Ott� Sealant
7" 6" Expos }e
I- 12"
Figure 22: Plan View, ProEdge
BUILDING7. •
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named CA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
QUALITY9.
PRI Construction Materials Technologies, LLC— QUA9110 ; 813 621-5777; bwilson@pricmt.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 037940.02.12-1331
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVH2 EVALUATION FL10674-1116
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 10 of 10