Loading...
HomeMy WebLinkAboutPRESSURES PARADISE EXTERIORS "Building Our Quality Reputation One Customer At A Time SCC131150472 Property Information Building Information Owner: DONALD&JEANNE DOBBS Wind Zone: I70 MPH. Address: 753 CYPRESS ST Exposure Category: C PSL, FL 34952 Minimum Building Dimension: 35 ft. Mean Roof Height: 12 ft. Risk Category: II Design Pressure Calculations Opening Location Device Device Device Max Positive Max Negative Number JLZone t Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) l End 14 23 7 37.8 -50.6 2 lilt 35 37 7 37.8 -41.0 3 lilt 71 81 7 34.4 -37.6 4 Int - 35 36 7 37.8 41.0 5 Int 25 24 7 37.8 -41.0 6 End 51 37 7 37.1 -49.3 ._. -- --- - - - - - _7. End 51 37 7 ... 37,1 -49.3 8 End 51 37 7 37.1 -49.3 9 End 72 37 7 36.3 -47.6 t0 lilt 105 61 7 34.1 -37.3 Prepared in accordance 1ritk:ASCE 7-16.Chapter 30, H'ind Loads-Components and Cladding, 7Nh Ldttion(2020)Florida Building Code. _�...__ � page t of I