HomeMy WebLinkAboutWINDOW AND DOOR SCHEDULE A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Corner Zone -10%of feast horizontal dimension or 40%of the mean roof height,whichever Is smaller,but not less than 4%of least horizontal dimension or 3 ft.
OPENING (Location) IS THIS A PRODUCT PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE
GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M ROUGH WINDOW ARE
LOCATION Corner Zone WINDOW TYPE ACCEPTANCE TESTED MULLION
OPENING SHUTTERS
NUMBER or interior OR DOOR NUMBER {+}PSF {-}PSF {+)PSF {-)PSF SIZE DIMENSIONS REQ YININA REQ YIN
1 End Window 7,8"Lami 1G FL15779.3 50 50 37.8 -50.6 36x72 14x23 No No
2 Int Window 711"La`ni"I FL23505.3 60 65 37.8 -41.0 54 x 76.5 35x37 No No
3 Int Door V Lami IG FL11103.1 60 60 34.4 -37.6 96 x 96 71x81 No No
4 Int Window 7/8"L°"'i1G FL23505.3 60 65 37.8 -41.0 54x76.5 3506 No No
5 Int Window 7I8°La,ni IG FL23505.3 60 65 37.8 -41.0 s4 x 76.5 25x24 No No
6 End Window 7�8"L°ntilG FL15781.11 SS 60 37.1 -49.3 73x63 5107 No No
7 End Window 7/g'LamiTG FL23505.3 60 65 37.1 -49.3 54x75.5 5107 No No
8 End Window 718°L°miIG FL23505.3 60 65 37.1 -49.3 54x76.5 5107 No No
9 End Window "ft°LnmilG FL15781.11 55 60 36.3 -47.6 73x63 7207 No No
10 Int Window 7/8"Lami IG FL15781.14 55 60 34.1 -37.3 i 11 x 63 105x61 No No