SCC131150472
Propqrt
y Information Building Information
Owner: DIANE RUSSELL Wind Zone: 170 MPH.
Address: 5402 E ECHO PINES C1R Exposure Category: C
FORT PIERCE,FL 34951 Minimum Building Dimension: 27 ft.
Mean Roof Height: 12 f,
Risk Category: II
Design Pressure Calculations
Opening Location Device Device Device Max Positive Max Negative
Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf}
1 Int 72 48 7 35.6 38.8
---2 End 52_..__._. 48 7 36.4 -47.9
3 Int 25 24 7 37.8 -41.0
4 End 35 -------.___48 7 37.4 -49.8
5 End._W. 73 48 7 35.6 -46.2
Prepared bt accordance ivith:ASCE 7-16,Chapler 30.Wbtd Loads-Cntitponertts and Cladding. 711t.Edition(2020)Florida Building Code.