Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE FORM R405-2020 FLORIDAENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Perforrnance Method Project Nama: r-RADE RESIDENCE Builder Ni9me; Street' 3000 6ROCKSMITH ROAD Porrn1L Office; ST LUCIE COUNTY City,State.Zip: FORT PIERCE , FL,34945 Permit Number_ DEC 1.3 20 1 Owner: Jurisdiction_ ST LUCIE COUNTY Design Locatiw-. FL, Fori Fierce ccuniy: St. Lurie(rIcrida Climat Zane 2). t.?�trit 11 �1,I_ie CountYr 1, New aanstrua#im or existing N E aW(i=r4m Plans) 10. W ah Types(1540.0 sgft_) insulation Area 2. Single family or multiple family Doachad a.Concrete Block- Int Insul,Exterior R�4.1 1540.00 1? b, NJA R= Ft' 3. Number of units,if multiple family 1 C_MA R= ft" d. Ntimber of Bedrooms 2 d,NIA R= Ft' 5, Is this a worst case? 11.Ceiling Types (1626.0 sgft.) Insulation Arw a_Under Attic{Vented) R=19.0 1626.00 I'll 6, Conditioned floor area abme grade(ft2) 1626 b.NJA R= ft, Conditioned Pt"area below grado(ft�) c_N)A R= fF T. Window3{195.8 sgft_} Descriptim Area 12_Ducts R fV a_ U-Factor Sgl, U=0.6a 195.78 tt3 a_Sup:Attic, Ret: Attic,A.H:LAUNDRY 6 150 SHGC: SHGC-0.25 b. U-Factor: MA Ft2 13_trading systems kBtufhr Efficiency SHGC' a.CenlC#tI UrO 35.2 SEER:16.&D 0. U-Factor' N)A R2 SH�a0; Area Weighted Average Overhang Depth: 10_864 ft, . Heating systems kBtufhr Efficiency Area VV"hted Average 5HGC= D.250 a.Electric Strip Heat 27.0 CGP:1.00 S. Skylights Area c, U-Factor:(AVG) WA ftz 1S. Hot waters"rns SHGr,(AVG): NfA a_Electric Cap;50 gallons 9, FkrorTypes (1626.0 sgft.) IrtSulalion Area EF-0,980 a.Slab-0n-Grade Edge Insulation, R=0.0 1626,0Q ft2 b. Conservation features b, N!A R= ftz Nona c.N!A R= ftz 16.Credits None GlasslFloor Area: 0.10 Total Proposed Modified Loads; 46.47 PASS Total Baseline Loads: 51.87 I hereby certify that the plans and specifications covered by Review of the p41ns and 061c114E ST4 this calculation are in corrtpliancewith the Florida Energy specifications covered by this Code- calculation indicates cDmpliance with the Florida Energy Code. �'�` W. PREPARED BY: Before construction is completedDd DATE; - - 1 _ this building will be inspected forLj compliance with Section 553.908 s hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code, b1)WE OWNERIAGENT;_.. BUILDING OFFICIAL- DATE: I f.f - Z 7 " -_. I DATE- - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403,3.2.1. -Compliancy requires an Air Barrier and Insulation Inspection Checklist in accordance with R462.4.1,1 and this project requires art envelope leakage test report with envelope leakage no greater than 5.00 AGH50 (R402,4.1.2). 7.,23'2021 o w3 Pu EnergyGaugo�USA 7.0_00-FlaRe57470 FIB Tth Edition(2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: FRADE RESIDENCE Bedrooms: 2 Address Type; Street Address Building Type: User Conditioned Area_ 1626 Lot A Owner Name: Total Stories. 1 BlocklSubdileision: #of Units: 1 Worst Case-. No PlatBook= Builder Name: Rotate Angle_ 0 Street 3000 BROCKSMITH R Permit Office_ ST LUCIE COUNTY Gross Ventllatior7: No County St. Lucie Jurisdiction: ST✓*UCIE COUNTY Wholo Hausa Fan: No City_State.Zip: FGRT PIERCE . Family Type: DeLxhed FL. 34945 NGWIF-XiSting- New(From Plans) Comrn0ll: CLIMATE / Design Temp I nt Dcsign Tomp Healing Design DailyTenar �I Vesign Location TMY Site 97.5% 2.5% Winter Summer Dagree days Moisture Range FL, Fart Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Law BLOCKS Number Narna Area Vohune 1 Entire Hause 1626 13008 SPACES Number Name Area Vdume Kitchen 0ccLipants Bed(pprn5 Infil11) Finished Coaled Herat 1 BATH so 840 No 0 1 Yee Yes Yes 2 PANTRY 30 240 No 0 1 Yes Yes Yes 3 LAUNDRY 65 520 No 0 1 Yes Yes Yes 4 BEDROOM 169 1352 No 0 1 1 Yes Yes Yes 5 KITCHEN 368 2864 Yes 0 1 Yes Yes Yes 6 FOYER1LFVING 414 3312 No 0 1 Yes Yes Yes 7 M BATH 168 1344 No 0 1 Yen Yes Yes 8 M WIC 2 35 280 No 0 No YEs Yes cl M WIC 1 35 . 2w No` 0 1 Yes Yes Yes •0 MASTER BED ROO 272 21T6 No D 1 1 Yes Yes Yes FLOOR # Floor Type Space Perimeter Perimeter RNMue Area Joist R-Value Tile Wood Carpel 1 Slats-On-Grade Edge Insulation BATH la ft 80 ft2 _ 1 0 p 2 Slab-On-Gracie Edge I nrvWion PANTRY 5 ft 30 ft� __ 1 0 Q 3Slab-Dn-Grade Ed"Insulation LAUNDRY 5 ft 65 iv 1 0 0 4 Slab-On-Grade Edge Insulation BEDROOM 26 it 169 r-' _-- 1 0 0 5 Slat�-On-Grade Edge Insulation KITCHEN 26 ft 358 W _--_ 1 0 0 6 Slat-On-Grade Edge Insulation FOYER4-IVINi3 23 ft 414 ft2 _-- 1 in 0 7Sleh-On-GradeEdgoInsulation MRATH 26ft 158fC ___ 1 4 0 MX2021 5;06 pM EnergyGa qea ?VSA 7.,, p-FlaRes202O FBC 7tn Eddon(2020} Oompliant"tware Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Fkx)r Type Space Pwimgter PerirrKAer R-Value Area Joist R-Value Tire }Nood Carpet 8 Slab-On-Grade Edge I rksulaiion M W JC 2 1 IR 35 ft3 1 D D 9.Slab-On-Grada Ed90 Insulation MWIC1 5ft 35 ft2 __. 1 D 0 1 USlab-On-Grade Edge Insulation MASTER BEDRO 3411 272 fL2 _.__ 1 4 0 ROOF / Root Gamle RcO Rad 5dar SA Emitt Emitt Deck Pitcl 1/ # Type Materials Area area Color Birr Absor, Tested Tested Insul, (deg 1 Hip Compasifion shingles 1818 f12 D r-' Medium N 0.3 No 0.9 No 0 25.5 ATTIC V 4 Type Ventilation Vant.Ratlo(1in) Areo Re$ IRCC 1 Full attic Vented 150 1626 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UrederAldc(Ventep) BATH 19 Blown 80ft 4.1 W and 2 UnderAldc(Ventsd) PANTRY 19 Bloom 30ft° 0.1 Wo0d 3 U rider Atdc(Verited) LAUNDRY 19 Blown 65 ft3 .1 Wood 4 Under Attic(Vented) BEDROOM 19 Blorm 169 FF 0.1 W ood 5 Under Attic(Vented) KITCHEN 19 Blown 358 Ft2 0.1 Wood 6 Under Attic(Vented) FOYER LIVING 19 Bloom 414 W 0_1 Wmd 7 Under Attic(Vented) M BATH 19 Blm-m 168 Rg 0-1 Woad 8 Under Attic(Vented) M WIC 2 79 ElIown 35fe 0.1 +Naod 9 Under Attic(Vented) M WIC 1 19 Blown 35 ft.2 0.1 VV cod 10 Under Attic (Vented) MASTER BEDRO 19 nkmm 272 W 0-1 vv Dad WALLS Adjeceni S Pace Cavity Width Helght Slthing Framing Solar Below 1 N Exterior Concrete Slcck-Im Insul BATH 4.1 8 0 8 0 64_1)ft3 0 0 1).3 0 2 E Exterior Concrete Mack-IN Insul BATH 4.1 10 0 8 0 80.0 ft2 0 0 0.3 0 3 N Exterior CW0rete 6lvck-Ink Insul PANTRY 4.1 5 D 8 D 40.0 ft' 0 0 0.3 0 � 4 N Exterior CmcreteSlock-IntlnsulLAUNDRY 4.1 5 0 8 D 40.0ft' 0 0 0,3 0 5 N Extoigr Concrete Block-Int Ins ulBEDROOM 4.1 13 D E D 1 U4.0 H2 0 0 0,3 0 6 UY Exterior Concrete Block-Int Ins Li I BE D ROOM 4.1 13 D E 0 104.0 fly 0 0 0.3 0 ` 7 E Exterior Concrete Black-Int rnsuI KITCHEN 4.1 26 0 12 0 312,U f? 0 0 0.3 0 8 W Exterior Concrete Block-Int InsuFOYERIIVIN 4.1 23 0 12 0 2713.0 ft2 0 0 0.3 0 9 E Exterior Concrete Block-Int Insui M!LATH 4.1 17 0 8 0 136.0 ft' 0 0 0.3 0 10 S Exterior Concrats Block-Int Irrsul M BATH 4.1 9 0 8 0 72.0 ft" 0 D 0.3 V 11 S Exterior Concrete Block-Int Irlsul M VVIC 1 4.1 5 0 8 0 40.0 W D D 0-$ 0 12 S Exieri4r Concrete Block-Int lasuMASTER BE 4.1 17 0 9 0 136.0 ft2 0 D 0.3 0 7f23J2021 5;08 PM EnergyGauge�USA 7.0-00-FIi�Res2M FBC 7th Edition(2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cawity Width Height .5heathing Fr�rrtir,g $dear BE?IW 13 vv Exterior Concrete Block- Int insuMASTER BE 4.1 17 0 B 0 136-0`N 0 0 4.3 0 WINDOM Orientation shown is the antored,Pmpned orientEOw. Wall Overhang # Ornt III) Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screenin 1 N 1 Metal Low-E Single Yes 0.65 0.25 Y 4.0 ft2 2 fl 0 in t ft 4 in None None 2 E 2 Me1aI Lbw-E Single Ye.5 0.65 0.25 Y 17.S ft2 14 ft 0 in 1 ft 4 in None None 3 by 6 Metal Law-E Si ngie Yes 4.65 025 Y 15.0 W 2 ft 0 in 1 fl 4 in None None 4 E 7 Metal Low-E Singlo Yes 0.65 0.25 Y 24.0 ftE 14 It 0 in 1 ft 4 in Nave None 5 E 7 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft' 14 ft a in 1 ft 4 in None None 6 W 8 Mehl Low-E Single Yes 0.65 4,25 Y 30.fl ft2 16 ft 0 in 1 ft4 in None None 7 Y4 B Metal Lav-E Single Yes D.65 4.25 Y 41.11 ft' IS ft 0 in t fl 4 In None None B S 14 Metal Lcw-E Single YoS D.65 4.25 Y 9.0 ft' 2 fl 0 ire t fl 4 in None plane 9 S 12 Metal Lav-E Single Yes 0.65 4.25 Y 210.13 ft' 2 fl 0 In 1 fl 4 In None Nano 1 i1 w 13 Metal Lax-E Single Yes 0.65 4.25 Y 15.,0 ft' 2 ft 0 In i fl 4 in None Name INFILTRATION # Scope meLbE i SLA CFM 54 ELA EgtA ACH ACH 56 1 Wholehouse Proposed ACH(50) .000254 1084 59.47 111.t36 .0902 5 HEATING SYSTEM # sySlem Type Subtype Speed Efficioncy Capacity Blocs Ducts 1 Electric Strip Heat) None COPA 27 kBluft 1 sys#1 COOLING SYSTEM 4 System Type Subtype S'Jbt-yg3e Efficiency Capacity Air Flaw SHE Back Ducts 1 Central UnIU split Sing a SEER; 16 35.2 kBtutr 1456 cfrn 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Lo:atior E= Cav Use Scrpnt Gonscrraton 1 Electric Nano LAUNDRY 0.98 F>'.;nl 623 gal 120 deg None SOLAR HOT WATERSYSTEM FSEC Cdtectar Storage Cert # Caempany Name S,stc7 `,Uvc r CdJaelor ModO Area Volume FEF None None W W23J2021 5-08 PM E nerqyGaugeO USA 7.0,00-FlaRes2020 FBC 7th Edition(2020) Compliant Soflurare Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT DUCTS f --Supply — Return---- Air CFM 25 CFM25 HVAC# 1f L oc-alion R-Vi%lue Atem Loralion Area Leekego Ty;c Hardler TOT OUT QN RLF H6dt Cod 1 Attic 6 150 ft Attic 16 fY de`ault Luakeoe LAQNI�RY (Velault)c(Defaull}c 1 1 TEMPERATURES Programeble Thermostat N GNlirkq Fens; CDDling Jon Feb Mar Apr May Jun Ju Aug ChGt Nov Dec Venting Jan Feb } Mair �7C�Apr May � Jun � Jul Jan Feb Mar Apr May Jun Jul rj Aug Sp Oci } Nov Od Nov a Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 g 10 11 12 CcAmg(VVD) AM 78 78 78 78 78 7$ 78 78 80 84 84 80 PM 84 80 80 BD 78 78 713 78 78 78 78 78 Cooling ( EH) AM 79 78 78 78 78 78 78 78 80 80 80 s0 PM BD 80 80 80 74 78 78 78 78 78 78 78 Heating(WD) AM 65 65 06 es 65 65 65 68 68 68 68 68 PM 8B GB fib 68 673 68 68 68 68 68 68 68 Heating(VWEH) AM 65 65 65 65 65 B 65 68 1J8 68 68 438 PM 63 68 fib fig 68 68 68 68 Ei8 68 68 438 MASS Mass Type Area Thickness Fumiture Fraction Spare Default{$Ibs+sq,ft_ 0 W 0 ft 0.3 BA7H Default(a IbaJsq.ft, fF ft 0,3 PANTRY Dafauli{B Ibslsq,ft, T ft 0.3 LAUNDRY Default(B IbsOsq.ft_ ft, ft 0.3 SEDROOM Defaulgg IbsJeq.ft- ft, ft 0.3 KITCHEN Defaull(B Ibslsq.ft_ fit ft 0.3 FOYERJLIVING Defaull(B Jbsisq.ft. ftt ft 0.3 M BATH Default(B ibslsq.ft. ftz ft 0.3 M WIC 2 Default(B Ib0sq.ft. ft? ft 0.3 M WIC 1 Default 8lbsfs _ft. ft' R 0.3 MASTER BED ROO 7123f2021 5:08 PM EnergyGauge69 USA 7.0.00-FlaRes2020 FBC 7th Edition(202D} Compliant S&Lwere Page 5 of 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Projer 1 Name: FRADE RESIDENCE Builder flame. Ste99t: 3000 BROCKSMITH ROAD Permit Office- ST LUCIE COUNTY City,State,Zip: FORT PIERCE,FL. 34945 Permit Numbrx= � Owner: Jurisdiction_ 5T LUCIE COUNTY u Design Location: FL, For(Pkoos C1 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a Conti n uous air barrier_ not be used as a seallrw)material. requirements Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling?soffit shall be aligned with the The insulation in d eilingfattio insulation and any gaps in the air baerier shall be sealed- nY reaped barrier. g�saffil shall be aligned with the air barrier. Access openings.drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of The foundat"and sill plate shall be sealed- Cavities within corners and headers of frame walla The junction of the top plate and the top of AxtL�fior walls shall be sealed_ shall be insulated by completely filling the oa%ity with a Knee walls shall ba sealed. material having a Thermal resistance of R-3 per inch Exterior thermal envelope in5uiation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows. skylights The space between vvindow,rdcar jambs and franiing, and and doors skylights and framing shall be sealed. Rim joists Rim jests shall include the air barrier. Rim 05t5 shall be insulated. Floors The air barrier shall be installed at any exposed edge of Insulation. Floor frsrrrirsg aaviiy insuiatim shall be installed to (including maiatairr permanent contact with the underside of abavcrgarage subfloor decking,or fioorframing cavity insulation shall and caniikNered floors) be perm itted to be in contact with the top side of S heal hing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walIs Exposed earl!,irL unvenUd crawl spaces shall be covered vrith a Where pro,Aded instead of floor insulation_insulation Class l vapor retarder with overlapping joints taped. shall be pem iLanentiy attached to the crawispace waifs. Shafts, penetratians Duct shafts, utility p%metrations,and flue shafts opening to exierior or unucnditioned space shall i%sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by in5uia6on that on installation readily conforms to the available cavity spaces. Garage separation Air sealing s hall be provided between the garage and c>w<Jitior1W Spaces_ Recessed lighting Recessed fight fixtures insl sled in the building thermal envelope shall Recessed light foctures installed in the building be sealed to the finished surface, thermal envelope shall be air tight and IC rated_ Plurnbirsg ana wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls,or insulation that on rnsiallatipn rwdiiy Ggnforms ip awailable space shall a)lend f)ehind giioineln wiri Shuorerltub The air barrier installed at exterior waifs adjacent to showers and Exterior walls adjacent to showers and tubs sftell be on exterior wail tubs shall semrate them from The showers and tubs. I insulated. 1=lectrie011phone box on T he air barrier shall be installed behind ciectrical or comm u n icaliun wdakr walls boxes or air-sealed booces stiAl be installed. HVAC registar boots HVAC supply and return register boots that pew.rate buiiaing thermal envelope shall be sealed to IN?sub-ilpw,wall c,Qvering or ceiling Concealed When required to be sealed,concealed flee sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufaC turer.Caulking or other adhrrsive Sealants shall not be used to fill voids between fire sprinkler cover plates and waits or ceilings. a_In addition,inspection pf log wags shall be in accordance with the provisions of ICC-400. M3f2021 5:09 PM EnergyGaugdZs)USA 7.0.00-FlaRes202O FBC 7th Edltlon(2020) C-omp4gnt SaFtwam Page 1 d 1 FORM R405- 020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 90 The iower the E nergy Perform a n ce Index, the more efficient the home. 3000 BROOK MITH ROAD, FORT PIERCE, FL, 34W 1. New oorrslruotian or existing New(From Plans) 10- Wall Type and Insulation Insulatlon Area 2, Single family or multiple family detached a-Concrete Block-In[insul,EyWor R=4-1 1540-00 It' b. NIA R= It° 3. N umb*r of units, if multiple famiiy 1 c-NfA R= IV 4, Number of Bedrooms 2 d. NIA R= Os S. Is this a wewst case? No 1 1.Ceikng Type and insulation Ievel Insulation Area EL Under Attic(Vented) R=19-0 1626-00 ft' 6. Ccnditlonedllaararea(III 1tr26 b.NIA R= ft2 7. WIndaws" Descrotim Area c.6UA R= W a- U-Factor' gl,1 ,05 195,T8 ft= 12.Ducts,location&insulation level R ft2 a.Sup;Attic, Ret;Attic,AH: LAUNDRY 6 150 SHGC: HGC=0-25 b. Li-Factor: NfA ft2 $HOC' 13.Cooling systems kBtulhr Efficiency 0, U-Factor. NIA ft2 a-Gentral Unit 35.2 SEER:16.00 $HOC; d, V-Faolor; NfA ft2 14-Heating systems l<B�hr Eftlelency $HOC: a. Electric Strip Heat 27-0 GQPA.00 Area W elghted Avuaga Overtiang Depth: 1 D.t?Sa ft. Area Weighted Aywage SHGC' 0-250 8- Skylights Description Area 15-Hot water sy9tem5 Cap:50 gallons a. U-Factw(AVO)' NfA fe s. Elec#rio EI=:0,98 SHQC(AVG): WA b- Conservation features 9- Floor Types Insulation Area None a. SratrOn-Grade Edge Insulation R=0.4 1626-00 ff Credits(Performance rneabnd) Nang b.NIA R= ff c. N.A R= ff I certify that #his home has ccrnpiiad with the Florida Energy Efficiency Code for Building } Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection, Otherwise, a new EPL Display Card will be completed based on installed Corse oompiiant features, LU Builder Signature: Date: .2 _ 0 Address of New Home: Ci#y,+FL alp; �i }4 Note: This is not a Building Energy Rating- If your Index is below 70, your home may qualify for enemy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Cornrnlssion's support staff, "Label required by Section R3011.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 712a?2421 5:09 PM EnergyrGauge+,USA 7.0.00- RaRes2020 FSC 71h Edition(2020) Cam pliant Software Sage 11 of 1