OFFICE OF THE FL# FL30304-R1
SFCRETARY
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Drexel Metals,Inc.
Address/Phone/Email 204 Railroad Drive
Ivyland, PA 18974
(502) 303-1511
jshumate@drexmet.com
Authorized Signature Jason Shumate
jshumate@drexmet.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity Architectural Testing,Inc., an Intertek Company
Quality Assurance Contract Expiration Date 12/31/2025
Validated By Locke Bowden P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL30304 R1 COI DRX19002.1 2020 FBC Eval NonHVHZ Metal Roofing,
final.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM B 117 2016
ASTM G 155 2013
TAS 100 1995
TAS 110 2000
TAS 125 2003
UL1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvH%2bffZfjpUCe7wsl5artybuwVlhNBC%2bDmD2tyTc8fgfw%3d%3d 1/2
1/7/2021 Florida Building Code Online
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/09/2020
Date Validated 08/14/2020
Date Pending FBC Approval 08/26/2020
Date Approved 10/13/2020
Summary of Products
FL# Model,Number or Name Description
30304.1 HVHZ Metal Roofing Non-structural metal roof panels for use inside the HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL30304 R1 II DRX19003.1 2020 FBC Eval HVHZ Metal
Approved for use outside HVHZ: No Roofing final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-161 Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL30304 R1 AE DRX19003.1 2020 FBC Eval HVHZ Metal
Roofing final.pdf
Created by Independent Third Party: Yes
30304.2 non-HVHZ Metal Roofing Non-structural metal roof panels for use outside the HVHZ
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL30304 R1 II DRX19002.1 2020 FBC Eval NonHVHZ Metal
Approved for use outside HVHZ:Yes Roofing final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-161 Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL30304 R1 AE DRX19002.1 2020 FBC Eval NonHVHZ Metal
Roofing final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
® ci
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvH%2bffZfjpUCe7wsl5artybuwVlhNBC%2bDmD2tyTc8fgfw%3dg/o3d 2/2
CREEK Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020)
Manufacturer: DREXEL METALS, INC. Issued August 9, 2020
1234 Gardiner Lane
Louisville, KY 40213
(502)716-7143
www.drexmet.com
Manufacturing: Port St. Lucie, FL
Quality Assurance: Architectural Testing, Inc.,An Intertek Company(QUA1844)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year
Architectural Testing(TST1558) D9330.03-450-18 TAS 125 2003
Architectural Testing(TST1558) C8008.01-450-18 TAS 125 2003
Architectural Testing(TST1558) C8009.01-450-18 TAS 125 2003
Architectural Testing(TST1558) B3862.01-450-18 TAS 125 2003
Architectural Testing(TST1558) D0841.01-450-18 TAS 125 2003
Architectural Testing(TST1558) B8437.02-450-18 TAS 125 2003
Architectural Testing(TST1558) B8437.01-450-18 TAS 125 2003
Architectural Testing(TST1558) B8438.02-450-18 TAS 125 2003
Architectural Testing, Inc(an Intertek Company)(TST1527) F8542.01-450-44 UL 580 2006
UL1897 2012
Architectural Testing, Inc(an Intertek Company)(TST1527) G1899.01-450-18 UL 580 2006
UL1897 2012
Architectural Testing, Inc(an Intertek Company)(TST1527) F0755.01-450-18 TAS 125 2003
Architectural Testing, Inc(an Intertek Company)(TST1527) F9156.01-450-18 TAS 125 2003
Architectural Testing, Inc(an Intertek Company)(TST1527) F9156.02-450-18 TAS 125 2003
Architectural Testing, Inc(an Intertek Company)(TST1527) 0412-1012-06 TAS 125 2003
Architectural Testing(TST1558) C6413.02-450-18 TAS 125 2003
Architectural Testing(TST1558) D6207-01-450-18 TAS 125 2003
Architectural Testing(TST1558) 0412-0621-07 TAS 125 2003
Architectural Testing(TST1558) C6413.01-450-18 TAS 125 2003
Force Engineering&Testing(TST5328) 72-019TOT-07 UL 580 2006
UL1897 2012
Force Engineering&Testing(TST5328) 72-0314T-06A-C UL 580 2006
UL1897 2012
Force Engineering&Testing(TST5328) 72-0313T-06A-C UL 580 2006
UL1897 2012
Hurricane Test Laboratory(TST1527) 0412-1203.07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0412-1017-05 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0412-01012-06 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0412-0305-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0412-0306-06 TAS 125 2003
UL LLC(TST9628) 02NK11243 UL 580 2006
UL1897 2012
UL LLC(TST9628) 03NB13142 UL 580 2006
UL1897 2012
DRX19002.1 FL30304-R1 Page 1 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing Non-HVHZ
TECHNICAL SERVICES, LL,C
PRODUCT DESCRIPTION
1.5" Profile: 1.5-inch mechanical seam; Max.20-inch coverage
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Mechanical Description: Non-structural, min. 180' mechanical lock standing seam roof panel;
.........................................................................................................................................................................................................................................................................................................
Lock Material: Min.16 oz/ft ASTM B370 copper; Shall conform with FBC Section 1507.4.3
......................................................................................................................................................
Min.24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy=
min.50 ksi); Shall conform with FBC Section 1507.4.3
..........
Min. 0.032-inch Fluropon®coated ASTM B209 aluminum (Fy= min.24 ksi); Shall
conform with FBC Section 1507.4.3
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
1611 - 2a"
CV
r
1.5" Nail Strip ; Profile: 1.5-inch snap lock seam; Max.1 5.5-inch coverage
................................................:..........................................................................................................................................
Description: Non-structural, snap lock standing seam roof panel; slotted nail strip;
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90 steel (Fy=
min.50 ksi); Shall conform with FBC Section 1507.4.3
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
PBR and Profile: 3/-inch rib; Max. 36-inch coverage
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Econ Line Description: Non-structural,through fastened roof panel
PBR ....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min.26ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90(Fy=min.40
ksi); Shall conform with FBC Section 1507.4.3
............................................................................................................................................................................................................................................................................................................................................................................
le
a
5-V Crimp Profile: %-inch ribs; Min.20.5-inch, Max.24-inch coverage
....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Description: Non-structural,through fastened roof panel
..............<..................................................................................................................................................................................................................................................................................................................................................................
Material: Min.0.032-inch Fluropon®coated ASTM B209 aluminum (Fy= min.23 ksi); Shall
conform with FBC Section 1507.4.3
....................................................................<..................................................................................................................................................................................................................................................................................................................................................................
20.5`-24.0"G avenge
[w?ng 24,a--27.5`Coil}
W Ian. Mifening Ribs Panel Striations we Optional
DRX19002.1 FL30304-Rl Page 2 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing Non-HVHZ
TECHNICAL SERVICES, LL,C
PAC-150 Profile: 1.5-inch mechanical seam; Max.20-inch coverage
.........................................................................................................................................................................................................................................................
Description: Non-structural, min. 90°mechanical lock standing seam roof panel;
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min. 0.032-inch Fluropon®coated ASTM B209 aluminum (Fy= min.22 ksi); Shall
conform with FBC Section 1507.4.3
Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90 steel (Fy
min.55 ksi); Shall conform with FBC Section 1507.4.3
1-112"
12'-2G"
Snap-Clad Profile: 1.75-inch snap lock seam; Max. 18-inch coverage
.. ......................................................................................................................................................................................................................................................................................................................................................................................................
Description: Non-structural, snap lock standing seam roof panel;
..................................................................................................................................................................................
Material: Min. 0.032-inch Fluropon®coated ASTM B209 aluminum (Fy= min. 25 ksi); Shall
conform with FBC Section 1507.4.3
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
16'or 19'
1-314" 1-5fi3"
Optional factory Stiffening ribs and
or field applied striations optional.
sealant bead
Tite-Loc Plus Profile: 2-inch mechanical seam; Max.18-inch coverage
....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Description: Non-structural, min. 180' mechanical lock standing seam roof panel;
:.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy=
min.60 ksi); Shall conform with FBC Section 1507.4.3
: ..................................................................................................................................................................................................................................................................................................................................................................
Min.0.032-inch Fluropon®coated ASTM B209 aluminum (Fy= min.20 ksi); Shall
conform with FBC Section 1507.4.3
....................................................................<..................................................................................................................................................................................................................................................................................................................................................................
2"
I- 16"or 18"
STIFFENING RIBS AND STRIATIONS OPTIONAL
DRX19002.1 FL30304-R1 Page 3 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing Non-HVHZ
TECHNICAL SERVICES, LL,C
Econo Line 1" Profile: 1-inch snap lock seam; Max.16-inch coverage
:.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Clipless Description: Non-structural, snap lock standing seam roof panel; slotted nail strip;
.......................................................................................................................................................................................................................................................................................................................................................................................................................................
Material: Min.26 ga. Fluropon@ coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy=
min.40 ksi); Shall conform with FBC Section 1507.4.3
....................................................................................................................
Min. 0.032-inch Fluropon@ coated ASTM B209 aluminum (Fy= min.24 ksi); Shall
conform with FBC Section 1507.4.3
........................................................................................................................................................................................................................................................................................................................................................................................................................................
T
1"
Striations Optional
(Flat Shown)
Jacksonville Profile: 1.5-inch snap lock seam; Max.19-inch coverage
:.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Beach Series Description: Non-structural, snap lock standing seam roof panel; slotted nail strip;
1.5"Cli less ..................
Clip less Min.24 ga. Fluropon@ coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy=
min.50 ksi); Shall conform with FBC Section 1507.4.3
....................................................................................................................
Min. 0.032-inch Fluropon@ coated ASTM B209 aluminum (Fy= min.21 ksi); Shall
conform with FBC Section 1507.4.3
:.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
19"Coverage
Flat wiCCP Rear
(OPiexal Siu`t�niix�Ries AvaifaCls}
Miami Series Profile: 1.75-inch snap lock seam; Max. 18-inch coverage
:.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
1.75 Snap Description: Non-structural, snap lock standing seam roof panel;
Lock ..................................
Material: Min.24 ga. Fluropon@ coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy=
min.50 ksi); Shall conform with FBC Section 1507.4.3
Min.0.032-inch Fluropon@ coated ASTM B209 aluminum (Fy= min.24 ksi); Shall
conform with FBC Section 1507.4.3
.........<..................................................................................................................................................................................................................................................................................................................................................................
I
i
Palm Beach Profile: 1.5-inch mechanical seam; Max.20-inch coverage
.......................................................................................................................................................................................................................................................................................................................................................................................................................................
Series 1.5 Description: Non-structural, min.90'mechanical lock standing seam roof panel;
Mechanical ..............;..................................................................................................................................................................................................................................................................................................................................................................
Material: Min.24 ga. Fluropon@ coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy=
Seam min.50 ksi); Shall conform with FBC Section 1507.4.3
Min.0.032-inch Fluropon@ coated ASTM B209 aluminum (Fy= min. 24 ksi); Shall
conform with FBC Section 1507.4.3
:......................................................................................................................................................................................................................................................................................................................................................................................................................................
.
12" - 20" Widths Available
11/2"
Stiffening Ribs Optional
(Flat w/Clip Relief Shown)
DRX19002.1 FL30304-R1 Page 4 of 6
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing Non-HVHZ
TECHNICAL SERVICES, LL,C
Key West Profile: 1/2-inch ribs; Max. 24-inch coverage
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
Series 5-V Description: Non-structural, through fastened roof panel
Crimp ......................................................................................................................................... ........................................................................................................................................................................................................................................
Material: Min. 26 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy=
min. 50 ksi); Shall conform with FBC Section 1507.4.3
.....................................................................:..................................................................................................................................................................................................................................................................................................................................................................
24"Maximum Net Coverage
C_
N
Stuart Line Profile: 1-inch snap lock seam; Max.16-inch coverage
.......................................................................................................................................................................................................................................................................................................................................................................................................................................
Series 1"Nail Description: Non-structural, snap lock standing seam roof panel; slotted nail strip;
Stri ...............................................................................................................
p Material: Min. 24 ga. Fluropon®coated ASTM A792 AZ50, or ASTM A653 G90 steel (Fy=
min. 50 ksi); Shall conform with FBC Section 1507.4.3
........................................................................................................................................................................................................................................................................................................................................................................................................................................
16"
1"
DRX19002.1 FL30304-R1 Page 5 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK DREXEL METALS, INC.
Metal Roofing Non-HVHZ
TECHNICAL SERVICES, LLC
LIMITATIONS
1. This report is not for use in the HVHZ.
2. Fire classification is not within the scope of this evaluation.
3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4. Roof slope shall be in accordance with FBC Section 1507.4.2.
5. Reroofing shall be in accordance with FBC Section 1511.
6. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
7. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020)as evidenced in the referenced documents submitted by the named manufacturer.
N F�Fs;0 2020.08.09
No 74021 15:13:43
- *: :*
O:• STATE OF :4
O R �10... N��`� Zachary R. Priest, P.E.
i�ss •''••• • `J �� Florida Registration No. 74021
�ONA\-� Organization No.ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A— Installation (2 pages)
2) APPENDIX B—Approved Roof Systems (8 pages)
3) APPENDIX C—Design Wind Loads (4 pages)
DRX19002.1 FL30304-R1 Page 6 of 6
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
INSTALLATION
Note-Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component Product Installation Detail
#9-15 HWH wood screw
with sealing washer
#10 HWH wood screw
with sealing washer
#10 PH wood screw
#10-11 Eclipse Head Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion
wood screw with sealing resistant in accordance with FBC section 1507.4.4.
Fasteners washer
#10-13 PH wood screw
#12-11 PH wood screw
#14 WoodZAC®HWH
screws
#14-13 TH wood screw
#14 PH self-drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be
corrosion resistant in accordance with FBC section 1507.4.4.
1500SC 1.5-inch Sliding 26 ga.top with 22 ga. base galvanized steel, in-seam clip
Clip
24 ga.galvanized or stainless steel in-seam clip
'1
t.ax�
24 ga.PAC-150 Clip
d T
O.B76"
20 ga.galvanized or stainless steel in-seam clip
1.6T5"
Clips 20 ga.Snap-Clad Clip o
20 ga.galvanized or stainless steel in-seam clip
1.875�
0
20 ga.Snap-Clad
Continuous Clip
0
0
DRX19002.1 FL30304-Rl Page 1 of 2
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LL C
APPENDIX A
Component Product Installation Detail
18 ga. base/22 ga.tab galvanized or stainless steel in-seam clip
O
Tite-Loc Plus Clip
O
0.050-inch galvanized steel in-seam clip
43
Miami Series 1.75 Snap 1 .87 Q
Clips Lock Clip
LL_ 3.5o �I �-I .08 L
24 ga.galvanized steel in-seam clips
i ,� _
63819'
Palm Beach Series 1.5
Mechanical Seam Clip E;::•
Bostik Chem Calk 915
Sealants Shall be applied in'%-inch wide continuous beads along the seam
Bostik 70-05A
DRX19002.1 FL30304-R1 Page 2 of 2
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
0 CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure(MDP)was calculated using a 2:1 margin of safety per FBC Section 1504.9.
2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center(o.c.)spacing given is the maximum allowable attachment spacing for the rated system.
5. The panel thicknesses stated in the tables below are the minimum thicknesses required.
6. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy= min.40 ksi)Wide Rib Deck(Type WR)
conforming to ANSI/SDI-RD1.0& FBC.
7. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood
sheathing at maximum 24-inch span.
Roof System Numbers and Definitions
1.5ML-W# 1.5 Mechanical Lock over Wood Deck(New or Existing)
1.5NS-W# 1.5 Nail Strip over WoodDeck(New or Existing)
PBR-W# PBR or Econo Line PBR over Wood Deck New or Existing
5VC-W# 5-V-Crimp over Wood Deck(New or Existing)
PC150-W# PAC-150 over Wood Deck new or Existing)
SC-W# Snap-Clad over Wood Deck New or Existing)
TLP-W# Tite-Loc Plus over Wood Deck(New or Existing)
TLP-S# Tite-Loc Plus over Steel Deck New or Existing
EL1C-W# Econo Line 1"Clipless over Wood Deck(New or Existing)
J1.5C-W# Johnsonville Beach Series 1.5"Clipless over Wood Deck New or Existing)
M1.75-W# Miami Series 1.75 Snap Lock over Wood Deck New or Existing)
P1.5M-W# Palm Beach Series 1.5 Mechanical Seam over Wood Deck(New or Existing)
K5VC-W# Key West Series 5-V Crimp over Wood Deck New or Existing)
S1 NS-W# Stuart Line Series 1"Nail Strip over Wood Deck(New or Existing)
Approved Systems for 1.5 Mechanical Lock over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 15/32 OPTIONAL 24 ga. 1.5 Mechanical Lock 1500SC 1.5-inch Sliding Clip with
1.5ML-W 1 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide two(2)#12-11 PH wood screws -59.75
spaced 24-inch o.c.
Min. 15/32 OPTIONAL 24 ga. 1.5 Mechanical Lock 1500SC 1.5-inch Sliding Clip with
1.5ML-W2 CDX plywood Versashield Solo As required per FBC Max. 16-inch wide two(2)#12-11 PH wood screws -123.5
spaced 6-inch o.c.
DRX19002.1 FL30304-R1 Page 1 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for 1.5 Nail Strip over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
1.5NS-W1 Min. 15/32 OPTIONAL As required per FBC 24 ga. 1.5 Nail Strip One(1)#12-11 PH wood screws 78 5
CDX plywood Versashield Solo Max. 15.5-inch wide spaced 11-inch o.c.along the nail strip
Approved Systems for PBR or Econo Line PBR over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
One(1)#9-15 HWH wood screw with sealing
washer placed 1.5-inches from each side of
Min. 15/32 OPTIONAL 26 ga. PBR panel lap and one(1)#9-15 HWH wood screw
PBR-W1 CDX plywood Versashield Solo As required per FBC Max.36-inch wide and sealing washer placed 1.5-inches to one -76.75
side of the each intermediate rib(5 fasteners
per panel;6"-9"-9"-9"-3"pattern); Fastener
rows spaced 24-inch o.c.
Approved Systems for S-V-Crimp over Wood Deck(New or Existing)—Install in compliance with PAC Contractors Association's Installation Details
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
One(1)#10 HWH wood screw with sealing
5VC-W1 Min. 15/32 OPTIONAL As required per FBC .032 Al 5-V-Crimp washer placed through the apex of the inside -74.75
CDX plywood Versashield Solo Max.24-inch wide rib at the panel lap; Fastener rows spaced
16-inch o.c.
One(1)#10 HWH wood screw with sealing
5VC-W2 Min. 15/32 OPTIONAL As required per FBC .032 Al 5-V-Crimp washer placed through the apex of the inside -176
CDX plywood Versashield Solo Max.24-inch wide rib at the panel lap; Fastener rows spaced
8-inch o.c.
DRX19002.1 FL30304-R1 Page 2 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
0 CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for PAC-150 over Wood Deck(New or Existing)—Install in compliance with PAC Contractors Association's Installation Details
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 15/32 OPTIONAL .032 Al PAC-150 24 ga. PAC-150 Clip with
PC150-W1 CDX plywood Versashield Solo As required per FBC Max.20-inch wide two(2)#10 PH wood screws -69.25
90'seam spaced 24-inch o.c.
Min. 15/32 OPTIONAL .032 Al PAC-150 24 ga. PAC-150 Clip with
PC150-W2 CDX plywood Versashield Solo As required per FBC Max.20-inch wide two(2)#10 PH wood screws -69.25
90'seam spaced 24-inch o.c.
Min. 15/32 OPTIONAL .032 Al PAC-150 24 ga. PAC-150 Clip with
PC150-W3 CDX plywood Versashield Solo As required per FBC Max.20-inch wide two(2)#10 PH wood screws -99.25
90'seam spaced 6-inch o.c.
Min. 15/32 OPTIONAL 24 ga. PAC-150 24 ga. PAC-150 Clip with
PC150-W4 CDX plywood Versashield Solo As required per FBC Max.20-inch wide two(2)#10 PH wood screws -114.25
90'seam spaced 6-inch o.c.
Min. 15/32 OPTIONAL 24 ga. PAC-150 24 ga. PAC-150 Clip with
PC150-W5 CDX plywood Versashield Solo As required per FBC Max.20-inch wide two(2)#10 PH wood screws -136.75
180'seam spaced 12-inch o.c.
Min. 15/32 OPTIONAL .032 Al PAC-150 24 ga. PAC-150 Clip with
PC150-W6 CDX plywood Versashield Solo As required per FBC Max.20-inch wide two(2)#10 PH wood screws -166.75
180'seam spaced 12-inch o.c.
Approved Systems for Snap-Clad over Wood Deck(New or Existing)—Install in compliance with PAC Contractors Association's Installation Details
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 15/32 OPTIONAL .032 Al Snap-Clad 24 ga.Snap-Clad Clip with
SC-W1 CDX plywood Versashield Solo As required per FBC Max. 18-inch wide two(2)#10 PH wood screws -86
spaced 24-inch o.c.
24 ga.Snap-Clad Continuous Clip with
SC-W2 Min. 15/32 OPTIONAL As required per FBC .032 Al Snap-Clad eight(8)#10 PH wood screws per clip -151.75
CDX plywood Versashield Solo Max. 18-inch wide installed end-to-end to form a continuous clip
along the seam
DRX19002.1 FL30304-R1 Page 3 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
0 CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for Tite-Loc Plus over Wood Deck(New or Existing)—Install in compliance with PAC Contractors Association's Installation
Details
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min. 19/32 OPTIONAL 24 ga.Tite-Loc Plus Tite-Loc Plus Clip with
TLP-W1 CDX plywood Versashield Solo As required per FBC Max. 18-inch wide two(2)#10 PH wood screws -106.75
spaced 24-inch o.c.
Min. 19/32 OPTIONAL .032 Al Tite-Loc Plus Tite-Loc Plus Clip with
TLP-W2 CDX plywood Versashield Solo As required per FBC Max. 18-inch wide two(2)#10 PH wood screws -121.75
spaced 24-inch o.c.
Min. 19/32 OPTIONAL .032 Al Tite-Loc Plus Tite-Loc Plus Clip with
TLP-W3 CDX plywood Versashield Solo As required per FBC Max. 18-inch wide two(2)#10 PH wood screws -174.25
spaced 6-inch o.c.
Min. 19/32 OPTIONAL 24 ga.Tite-Loc Plus Tite-Loc Plus Clip with
TLP-W4 CDX plywood Versashield Solo As required per FBC Max. 18-inch wide two(2)#10 PH wood screws -196.75
spaced 24-inch o.c.
Approved Systems for Tite-Loc Plus over Steel Deck(New or Existing)—Install in compliance with PAC Contractors Association's Installation
Details
System Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
No. (psf)
Min.%-inch Tite-Loc Plus Clip with
Min.22 ga. Approved 24 ga.Tite-Loc Plus
TLP-S1 steel deck As required polyisocyanurate As required per FBC Max. 18-inch wide two(2)#14 PH self-drilling screws -106.75
spaced 24-inch o.c.
insulation board
Min.%-inch Tite-Loc Plus Clip with
Min.22 ga. Approved 24 ga.Tite-Loc Plus
TLP-S2 steel deck As required polyisocyanurate As required per FBC Max. 18-inch wide two(2)#14 PH self-drilling screws -196.75
spaced 24-inch o.c.
insulation board
DRX19002.1 FL30304-R1 Page 4 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for Econo Line 1" Clipless over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP
No. Insulation (psf)
EL1C-W1 Min. 15/32 OPTIONAL As required per FBC 26 ga,Econo Line 1"Clipless One(1)#10 PH wood screws -71
CDX plywood Versashield Solo Max. 16-inch coverage spaced 6-inch o.c.along the nail strip
One(1)#10 PH wood screws
EL1 C-W2 Min. 15/32 OPTIONAL As required per FBC .032 Al Econo Line 1"Clipless spaced 6-inch o.c.along the nail strip; -78 5
CDX plywood Versashield Solo Max. 16-inch coverage Bostik 70-05A applied to both sides of the male
rib prior to seam engagement;
Approved Systems for Jacksonville Beach Series 1.5" Clipless over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP(psf)
No. Insulation
OPTIONAL .032 Al Jacksonville Beach One(1)#10 PH wood screws
J1.5C-W1 Min. 15/32 Approved fire As required per FBC Series 1.5"Clipless spaced 6-inch o.c.along the nail strip; -76.75
CDX plywood barrier or insulation Max. 19-inch coverage Bostik 70-05A applied to both sides of the male rib
prior to seam engagement;
OPTIONAL 24 ga.Jacksonville Beach One(1)#10 PH wood screws
J1.5C-W2 Min. 15/32 Approved fire As required per FBC Series 1.5"Clipless spaced 6-inch o.c.along the nail strip; -97 25
CDX plywood barrier or insulation Max. 19-inch coverage Bostik 70-05A applied to both sides of the male rib
prior to seam engagement;
OPTIONAL .032 Al Jacksonville Beach One(1)#10 PH wood screws
J1.5C-W3 Min. 15/32 Approved fire As required per FBC Series 1.5"Clipless spaced 3-inch o.c.along the nail strip; -108.5
CDX plywood barrier or insulation Max. 19-inch coverage Bostik 70-05A applied to both sides of the male rib
prior to seam engagement;
OPTIONAL 24 ga.Jacksonville Beach One(1)#10 PH wood screws
J1.5C-W4 Min. 15/32 Approved fire As required per FBC Series 1.5"Clipless spaced 3-inch o.c.along the nail strip; -161
CDX plywood barrier or insulation Max. 19-inch coverage Bostik 70-05A applied to both sides of the male rib
prior to seam engagement;
DRX19002.1 FL30304-R1 Page 5 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for Miami Series 1.75 Snap Lock over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP(psf)
No. Insulation
Min. 15/32 OPTIONAL .032 Al Miami Series Miami Series 1.75 Snap Lock Clip with
M1.75-W 1 CDX plywood Approved fire As required per FBC 1.75 Snap Lock two(2)#10 PH wood screws -110.5
barrier or insulation Max. 14-inch coverage spaced 12-inch o.c.
Min. 15/32 OPTIONAL 24 ga. Miami Series Miami Series 1.75 Snap Lock Clip with
M1.75-W2 CDX plywood Approved fire As required per FBC 1.75 Snap Lock two(2)#10 PH wood screws -114.25
barrier or insulation Max. 18-inch coverage spaced 16-inch o.c.
Min. 15/32 OPTIONAL .032 Al Miami Series Miami Series 1.75 Snap Lock Clip with
M1.75-W3 Approved fire As required per FBC 1.75 Snap Lock two(2)#10 PH wood screws -114.25
CDX plywood barrier or insulation Max. 14-inch coverage spaced 6-inch o.c.
Min. 15/32 OPTIONAL 24 ga. Miami Series Miami Series 1.75 Snap Lock Clip with
M1.75-W4 Approved fire As required per FBC 1.75 Snap Lock two(2)#10 PH wood screws -156.75
CDX plywood barrier or insulation Max. 18-inch coverage spaced 8-inch o.c.
Approved Systems for Palm Beach Series 1.5 Mechanical Seam over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
.032 Al Palm Beach Series Palm Beach Series 1.5 Mechanical Seam Clip
P1.5M-W1 Min. 15/32 OPTIONAL As required per FBC 1.5 Mechanical Seam with two(2)#10 PH wood screws -63.5
CDX plywood Versashield Solo Max.20-inch wide spaced 24-inch o.c.
90'seam
24 ga. Palm Beach Series Palm Beach Series 1.5 Mechanical Seam Clip
P1.5M-W2 Min. 15/32 OPTIONAL As required per FBC 1.5 Mechanical Seam with two(2)#10 PH wood screws -93.5
CDX plywood Versashield Solo Max.20-inch wide spaced 24-inch o.c.
90'seam
24 ga. Palm Beach Series Palm Beach Series 1.5 Mechanical Seam Clip
P1.5M-W3 Min. 15/32 OPTIONAL As required per FBC 1.5 Mechanical Seam with two(2)#10 PH wood screws -101
CDX plywood Versashield Solo Max.20-inch wide spaced 6-inch o.c.
90'seam
24 ga. Palm Beach Series Palm Beach Series 1.5 Mechanical Seam Clip
P1.5M-W4 Min. 15/32 OPTIONAL As required per FBC 1.5 Mechanical Seam with two(2)#10 PH wood screws -123.5
CDX plywood Versashield Solo Max.20-inch wide spaced 6-inch o.c.
180'seam
DRX19002.1 FL30304-R1 Page 6 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX B
Approved Systems for Palm Beach Series 1.5 Mechanical Seam over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
.032 Al Palm Beach Series palm Beach Series 1.5 Mechanical Seam Clip
P1.5M-W5 Min. 15/32 OPTIONAL As required per FBC 1.5 Mechanical Seam with two(2)#10 PH wood screws -131
CDX plywood Versashield Solo Max.20-inch wide spaced 6-inch o.c.
180'seam
Approved Systems for Key West Series 5-V Crimp over Wood Deck(New or Existing)
System Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
No. (psf)
One(1)#10 HWH wood screw with sealing
Min. 15/32 OPTIONAL 26 ga.5-V-Crimp washer placed through the apex of the inside
K5VC-W1 CDX plywood Versashield Solo As required per FBC Max.24-inch wide rib at the panel lap and through the center rib -78.5
of the panel(12-inch o.c.across the panel);
Fastener rows spaced 16-inch o.c.
One(1)#14 WOOdZAC®HWH wood screw
Min. 15/32 OPTIONAL 26 ga.5-V-Crimp with sealing washer placed through the apex of
K5VC-W2 CDX plywood Versashield Solo As required per FBC Max.24-inch wide the inside rib at the panel lap and through the -106.75
center rib of the panel(12-inch o.c.across the
panel); Fastener rows spaced 8-inch o.c.
Approved Systems for Stuart Line Series 1" Nail Strip over Wood Deck(New or Existing)
System Deck Fire Barrier/ Underlayment Roof Panel Panel Attachment MDP(psf)
No. Insulation
OPTIONAL 24 ga.Stuart Line Series One(1)#10 PH wood screws
S1 NS-W1 Min. 15/32 Approved fire As required per FBC 1"Nail Strip spaced 12-inch o.c.along the nail strip; -91.25
CDX plywood barrier or insulation Max. 16-inch coverage Bostik Chem-Calk 915 applied along the
fasteners prior to seam engagement;
OPTIONAL 24 ga.Stuart Line Series One(1)#10 PH wood screws
Min. 15/32 spaced 6-inch o.c.along the nail strip;
S1 NS-W2 Approved fire As required per FBC 1"Nail Strip -136.75
CDX plywood barrier or insulation Max. 16-inch coverage Bostik Chem-Calk 915 applied to top of male rib
on fastening side prior to seam engagement;
DRX19002.1 FL30304-R1 Page 7 of 7
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC.
2. Exposure B, C, and D shall be as defined in section 1609 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based on an effective wind area of 10-ft2 or less.
5. Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7. Wind directionality factor, Kd=0.85
8. Vu,t is shown in the tables below. Design wind loads are calculated using Vasd=VU,tA.6 per 1609.3.1.
9. Zone 2 is inclusive of Zone 2e,Zone 2n, and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11.
12. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
13. Zones 1,2, and 3 shall be defined as shown below. Dimension"a"shall be 10% of the least horizontal dimension or(0.4 x Mean Roof Height),whichever
is smaller, but not less than either 4%of the least horizontal dimension or 3ft
Gable Hip
3 2 3 3 2 131 a 3 2 3 a
2 1 2 2 1 2 2 1 2 2 1 2
3 2 3 3 2 3 a 3 2 3 a
a gala a al al
DRX19002.1 FL30304-R1 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure B(Roof slope between 2:12 and 12:12
Building Mean Basic Wind Speed mph
Type Zone Roof Height(ft) 120 130 140 150 160 170 180 190 200
20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6
25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3
1 30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7
40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5
50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2
60 -34.8 -40.9 -47.4 -54.4 -61.9 -69.9 -78.4 -87.3 -96.8
20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0
25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3
Enclosed/ 30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3
Partially 2 Open 40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2
50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5
60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 1 -75.3 -83.5
20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4
25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3
3 30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2
40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0
50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 1 -159.9
60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8
20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6
25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2
1 30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2
40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2
50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9
60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2
20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0
25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2
Partially 30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8
Enclosed 2 40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9
50 -54.1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 -150.2
60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6
20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4
25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2
3 30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7
40 1 -59.3 -69.6 -80.7 -92.7 -105.4 1 -119.0 -133.4 -148.7 -164.7
50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6
60 -66.3 1 -77.8 1 -90.3 1 -103.6 1 -117.9 -133.1 -149.2 -166.3 -184.2
DRX19002.1 FL30304-R1 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure C(Roof slope between 2:12 and 12:12
Building Mean Basic Wind Speed mph
Type Zone Roof Height(ft) 120 130 140 150 160 170 180 190 200
20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5
25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0
1 30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6
40 -42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4
50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1
60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7
20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5
25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1
Enclosed/ 30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8
Partially 2 Open 40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7
50 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 1 -163.4 -181.0
60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7
20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7
25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6
3 30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5
40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 1 -205.3
50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2
60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1
20 -43.2 50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9
25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2
1 30 -47.0 -55.1 64.0 73.4 -83.5 -94.3 -105.7 -117.8 -130.5
40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5
50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2
60 -54.2 -63.6 73.7 -84.7 -96.3 -108.7 -121.9 -135.8 1 -150.5
20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9
25 -62.7 -73.6 85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3
Partially 30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7
Enclosed 2 40 -69.4 81.5 94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8
50 -72.8 -85.4 99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1
60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5
20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1
25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7
3 30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4
40 1 -81.1 -95.2 -110.5 -126.8 -144.3 1 -162.9 -182.6 -203.4 -225.4
50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2
60 -88.2 1 -103.5 1 -120.0 1 -137.8 -156.7 -177.0 1 -198.4 1 -221.0 1 -244.9
DRX19002.1 FL30304-R1 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
CREEK DREXEL METALS, INC.
Metal Roofing
TECHNICAL SERVICES, LLC
APPENDIX C
Gable/Hip Roofs in Exposure D(Roof slope between 2:12 and 12:12
Building Mean Basic Wind Speed mph
Type Zone Roof Height(ft) 120 130 140 150 160 170 180 190 200
20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0
25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5
1 30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1
40 -50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9
50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6
60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1
20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4
25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0
Enclosed/ 30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6
Partially 2 Open 40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6
50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9
60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6
20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2
25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1
3 30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0
40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8
50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7
60 -93.1 -109.3 -126.7 1 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6
20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8
25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2
1 30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5
40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 1 -162.5
50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1
60 -62.8 -73.7 -85.5 1 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5
20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2
25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6
Partially 30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1
Enclosed 2 40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2
50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5
60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9
20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1
25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7
3 30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4
40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4
50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2
60 1 -102.2 1 -120.0 1 -139.1 1 -159.7 1 -181.7 -205.1 1 -230.0 -256.2 1 -283.9
DRX19002.1 FL30304-R1 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.