Loading...
HomeMy WebLinkAboutPHOTOVOLTAIC SYSTEMREVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEG-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947 CODES AND STANDARDS1103 N 37TH ST,FORT PIERCE, FL 34947KELLY-HOLMES RESIDENCEVICINITY MAPSHEET INDEXG-01COVER SHEETPROJECT DESCRIPTION:OWNERHOUSE PHOTOA-01ROOF PLANS-01MODULE LAYOUTS-02.1STRUCTURE CALCULATIONE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGSHEET SHEET DESCRITIONCOVER SHEETA-00NOTES AND DESCRIPTIONELECTRICAL CERTIFICATION:STRUCTURAL CERTIFICATION:DESIGN CRITERIA:WIND SPEED (ULT): 160 MPHWIND SPEED (ASD): 124 MPHRISK CATEGORY:IIEXPOSURE:CS-01.1ARTIAL RESSURE AND MODULES EXOSURESUNPRO SOLAR4492 Eagle Falls Place,Tampa, FL 33619PH: (866) 450-1012INSTALLERCastillo Engineering Services LLC620 N. Wymore Road, Suite 250, Maitland, FL 32751TEL: (407) 289-2575Ermocrates E. CastilloLicense#: FL PE 52590ENGINEERKELLY-HOLMES, ROMONA22x375 LG NEON2: LG375N1C-A6 (375) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESEQUIPMENT SUMMARY22LG NEON2: LG375N1C-A6 (375) MODULES22ENPHASE: IQ7PLUS-72-2-US MICROINVERTERSSYSTEM SIZE:8.250 kW DC STCARRAY AREA #1:117.02 SQ. FT.ARRAY AREA #2:312.06 SQ. FT.I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINED INTHE MOST RECENT VERSION OF THE FLORIDABUILDING CODE. FBC 107, THE NEC 2017, ANDTHOSE SET FORTH BY THE FLORIDA SOLARENERGY CENTER CERTIFICATION.I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED.,CHAPTER 3. BUILDING STRUCTURE WILL SAFELYACCOMMODATE WIND LATERAL AND UPLIFTFORCES, AND EQUIPMENT DEAD LOADS.RACKING: UNIRAC LIGHT RAILATTACHMENT: FLASHKIT PROPROJECT SITEPROJECT SITESS-02ATTACHMENT DETAIL8.25 kW PV SYSTEMDS-01-08DATA SHEETSGOVERNING CODES :FLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7TH EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA MECHANICAL CODE, 7TH EDITION 2020 (FMC)NATIONAL ELECTRICAL CODE 2017 (NEC)ASCE 7-16FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC) System DescriptionThis system is a grid-tied, PV system, with PV generation consisting of 22x375 LGNEON2: LG375N1C-A6 (375W) Modules with a combined STC rated dc outputpower of 8,250W. The modules are connected into 22 Enphase: IQ7PLUS-72-2-USmicroinverters. The inverter has electronic maximum power point tracking tomaximize energy captured by the PV modules. The inverter also has an internalground fault detection and interruption device that is set to disconnect the array inthe event that a ground fault that exceeds one ampere should occur. The inverterhas DC and AC disconnect integrated system and labels are provided as required bythe National Electrical Code.When the sun is shining, power from the PV array is fed into the inverter,where it is converted from DC to AC. The inverter output is then used tocontribute to the power requirements of the occupancy. If PV power meets therequirements of the loads of the occupancy, any remaining PV power is sold backto the utility. When utility power is available, but PV power is not available,building loads are supplied by the utility.The inverter meets the requirements of IEEE 1547 and UL 1741.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxFigure 1: PV System Block DiagramSection..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........AC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBACDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberVent, Attic fan(Roof obstruction)PV Roof AttachmentTrussesConduitFire AccessUMAC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCB Combiner BoxDC Direct CurrentACD AC DisconnectDISC Disconnect(E) ExistingEL ElevationEQ EqualJB Junction BoxMCB Main Combiner BoxMFR ManufacturerMIN MinimumMISC Miscellaneous(N) NewOCPD OverCurrent Protection DevicePOCC Point Of Common CouplingPV PhotovoltaicSF Squarefoot/feetSTC Standard Test ConditionsTBD To Be DeterminedTYP TypicalUNO Unless Noted OtherwiseVIF Verify In FieldWP Weather ProofBatteryBATUtility meterGPGeneration PanelMDPMain Distribution PanelSoladeckSDNAVD North American Vertical datumMID Microgrid Interconnect DeviceREVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-00CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947NOTES ANDDESCRIPTIONSymbols:Abbreviations:68.5"41.0"RAILS IN THISPOSITION UNOFALL PROTECTION:ANCHORAGES USED FOR ATTACHMENT OF PERSONAL FALL ARREST EQUIPMENTMUST BE INDEPENDENT OF ANY ANCHORAGE BEING USED TO SUPPORT ORSUSPEND PLATFORMS, AND CAPABLE OF SUPPORTING AT LEAST 5,000 POUNDSPER EMPLOYEE ATTACHED, OR MUST BE DESIGNED AND USED AS FOLLOWS:·AS PART OF A COMPLETE PERSONAL FALL ARREST SYSTEM WHICHMAINTAINS A SAFETY FACTOR OF AT LEAST TWO.·UNDER THE SUPERVISION OF A QUALIFIED PERSONADDITIONAL INFORMATION·29 CFR 1926 SUBPART M, FALL PROTECTION. OSHA STANDARD.·1926.502, FALL PROTECTION SYSTEMS CRITERIA AND PRACTICES···1926.502(D)(15)ALLOWABLE/DESIGN PRESSUREPSFDOWN PRESSURE125UPLIFT PRESSURE, 2 RAILS88LG NEON2:LG375N1C-A6(375W) MODULES*MODULE RAILING MAY BE INSTALLED INLANDSCAPE ORIENTATION FOR MODULES WITHWEIGHTED PRESSURES BELOW 33 PSF* 111'-0"91'-10" 91'-10"111'-0"15'-10"24'-1"22'-1"55'-5"UMMDPCBACDTBSDREVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEA-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947ROOF PLANN 37TH ST,ROOF PLAN WITH FIRE SETBACKSAND PROPERTY LINESSCALE: 3/32" = 1'-0"A-0111-STORYHOUSEEXISTINGDRIVEWAYROOF #2(16) LG NEON2: LG375N1C-A6(375W) MODULES(N) (22) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSFIRE ACCESS AND PATHWAYSAS PER NFPA 1, 11.12.21" IMC, RMC, FMC, LFMC, PVC,HDPE, NUCC, RTRC, LFNC, FMT,ENT OR EMT CONDUIT RUN(E) SERVICE POINT ANDUTILITY METERING(N) SOLADECK3'- 0" FIRE SETBACKROOF #1(06) LG NEON2: LG375N1C-A6(375W) MODULES3'- 0" FIRE SETBACK3'- 0" FIRE SETBACK 3'- 0" FIRE SETBACK 3'- 0" FIRE SETBACK 3'- 0" FIRE SETBACK 3'- 0" FIRE SETBACK- FIRE SETBACK - 3 FT- ZONING SETBACK - 2 FTALL MODULES TO BE INSTALLEDAT LEAST 2 FT AWAY FROM ALLTHE ROOF EDGES(N) ALTERNATIVE POWER SOURCEAC DISCONNECT/RAPID SHUTDOWN(DISCONNECT 2 OF 2)(N) ENPHASE IQ COMBINER BOX(E) MAIN SERVICE DISCONNECT/ MAIN DISTRIBUTION PANEL(N) TAP BOX (DISCONNECT 1 OF 2) 47'-0"53'-11"4'-0" TYP.REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947MODULE LAYOUTS-01SCALE: 1/8" = 1'-0"1MODULE LAYOUTGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED ASSHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:WINDZONESNON-EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 14' - 0"1' - 4"2' - 0"0' - 8"ZONE 1'XXXXZONE 2e4' - 0"1' - 4"2' - 0"0' - 8"ZONE 2n2' - 0"0' - 8"2' - 0"0' - 8"ZONE 2r2' - 0"0' - 8"2' - 0"0' - 8"ZONE 3e2' - 0"0' - 8"2' - 0"0' - 8"ZONE 3r2' - 0"0' - 8"2' - 0"0' - 8"MODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 22 MODULESMODULE TYPE = LG NEON2: LG375N1C-A6 (375W) MODULESMODULE WEIGHT = 41.01 LBS / 18.6 KG.MODULE DIMENSIONS = 68.5" x 41.0" = 19.50 SFUNIT WEIGHT OF ARRAY = 2.10 PSFARRAY AREA & ROOF AREA CALC'SROOFROOF TYPEARRAYAREA(sq.Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZETRUSSSPACING#1ASPHALT SHINGLE117.02664.1217.6222.6°270°2"X4"24" O.C.#2ASPHALT SHINGLE312.06664.1246.9922.6°90°2"X4"24" O.C.LEGEND- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)SEE SHEET S-02.1 FOR SUPPORTING CALCULATIONS.2) EXISTING RESIDENTIAL BUILDING IS AN ASPHALT SHINGLE ROOFWITH A MEAN ROOF HEIGHT OF 15 FT AND SYP 2"X4" ROOF TRUSSESSPACED 24" O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEMRETROFIT IS 22.6 DEGREES. CONTRACTOR TO FIELD VERIFY ANDSHALL REPORT TO THE ENGINEER IF ANY DISCREPANCIESEXIST BETWEEN PLANS AND IN FIELD CONDITIONS.3) FIRE SETBACK TO BE 3' FROM RIDGES AND EDGES, AND 18" EACHWAY FROM HIPS AND VALLEYS PER NFPA 1, 11.12.2. * I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL 2020 7th ED. CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE WIND LATERALAND UPLIFT FORCES AND EQUIPMENT DEAD LOADS. *(E) FRONT YARD(N) UNIRAC LIGHT RAIL (TYP.)(56) PV ROOF ATTACHMENT@ 24", 48" O.C. MAX.(SEE SHEET S-02 FORATTACHMENT DETAIL)(SEE SHEET S-01.1 FOR PARTIALPRESSURE OF THE MODULE)(E) BACK YARD ROOF #2TILT - 22.6°AZIM. - 90°ROOF #1TILT - 22.6°AZIM. - 270°(N) (22) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSROOF #2(16) LG NEON2: LG375N1C-A6(375W) MODULESROOF #1(06) LG NEON2: LG375N1C-A6(375W) MODULES*MODULE RAILING MAY BE INSTALLED INLANDSCAPE ORIENTATION FOR MODULES WITHWEIGHTED PRESSURES BELOW 33 PSF* 4'-0" TYP.10'-9"10'-9"7'-0"3'-10"3'-10"P1P2P3P4P5P6REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-01.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947PARTIAL PRESSURE AND MODULES EXPOSURES-01.1SCALE: 1/8" = 1'-0"1ARTIAL RESSURE ANDMODULES EXOSURELEGEND- NON- EXPOSED MODULE- MIN. MODULE EDGE DISTANCE LINE- EDGE MODULE- MODULE EXPOSURE LINE- EXPOSED MODULE- WIND ZONE 1 (TYP)- WIND ZONE 2e (TYP)- WIND ZONE 2n (TYP)- WIND ZONE 2r (TYP)- WIND ZONE 3r (TYP)- WIND ZONE 3e (TYP)NOTE: PARTIAL PRESSURES OF THE WIND ZONES ONALL MODULES HAVE BEEN VERIFIED AND ARE WITHINTHE ALLOWABLE PER THE MANUFACTURERSPECIFICATION, INSTALLER SHOULD FOLLOW THELAYOUT TO AVOID HIGHER ZONAL PARTIALPRESSURES. ANY CHANGES IN LAYOUT SHOULD BEREPORTED BACK TO THE ENGINEER OF RECORD.- MISSING MODULEFOR EXPOSED MODULES2h2DISTANCE : 0' - 10"0.5hDISTANCE : 7' - 6"ALLOWABLE MODULE UPLIFT PRESSURE 2 RAILS : 88 PSFFOR NON-EXPOSED MODULES2h20.5hROOF #2(16) LG NEON2: LG375N1C-A6(375W) MODULESROOF #1(06) LG NEON2: LG375N1C-A6(375W) MODULES(E) FRONT YARD (E) BACK YARD *MODULE RAILING MAY BE INSTALLED INLANDSCAPE ORIENTATION FOR MODULES WITHWEIGHTED PRESSURES BELOW 33 PSF* 5"REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947ATTACHMENT DETAIL2ATTACHMENT DETAIL (ENLARGED VIEW)S-02SCALE: 6" = 1'-0"MODULE MID/END CLAMPSOLAR MODULEUNIRAC LIGHT RAIL5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMING(E) ROOF SHEATHINGASPHALT SHINGLE ROOFATTACHMENT DETAILS-02SCALE: 1" = 1'-0"12"X4" TRUSSES @ 24" O.C.2"X4" TRUSS SPANNER FORMISSED TRUSS ATTACHMENT(IF REQUIRED)UNIRAC L-FOOTUNIRAC LIGHT RAILGROUNDING MID/END CLAMP5/16"DIA. X 2.5"MIN.EMBEDMENT LAG SCREWAT EACH ATTACHMENT POINTINTO EXISTING FRAMINGFLASH KIT PROFLASHING2"X4" TRUSSES @ 24" O.C.SOLAR MODULEh₂ REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMES-02.1CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947STRUCTURECALCULATION REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947ELECTRICALLINE DIAGRAMNOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION,INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUMNUMBER OF MODULES PER STRING, MAXIMUM OUTPUT,MODULE MANUFACTURER AND MODEL NUMBER, INVERTERMANUFACTURER AND MODEL NUMBER, AS APPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANELGUTTER SPACE IS INADEQUATE.3. IF THE FUSED AC DISCONNECT WIRE RUN EXCEEDS 10 FTFROM THE POINT OF INTERCONNECTION, CABLE LIMITERS ORCURRENT-LIMITED CIRCUIT BREAKERS MUST BE INSTALLEDFOR EACH UNGROUNDED CONDUCTOR PER NEC 705.31.4. REFER SHEET DS-08 FOR LOAD CALCULATIONS.1ELECTRICAL LINE DIAGRAME-01SCALE: NTS(N) SOLADECK600V, NEMA 3RUL LISTEDQ CABLESL2L1NL2L1GN20A/2PGGGG (N) 125A ENPHASE IQ COMBINER 3(X-IQ-AM1-240-3) [WITH UPTO (4)2-POLE BREAKERS AND ENVOYCOMMUNICATION GATEWAY]GGGGGG(N) JUNCTION BOX600 V, NEMA 3RUL LISTEDGL2L1L2L1GGL2L120A/2PL2L1L2L1GGGGGGGGGGG#6 BARE CU WIRE PROTECTED PER NEC 250.64(B)FACTORY INSTALLEDBREAKER 10A OR 15ABREAKER FOR THE ENVOYSOLAR ARRAY (8.25 kW-DC STC)(22) LG NEON2: LG375N1C-A6 375 W) MODULES(02) BRANCHES OF 11 MODULES(2) #10 AWG THWN-2 – RED(2) #10 AWG THWN-2 – BLACKEGC #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNGG(3) #6 AWG THWN-2IN 1" IMC, RMC, FMC, PVC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT, ENTCONDUIT RUN(3) #6 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, PVC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT, ENTCONDUIT RUNTO UTILITY GRIDL1L2N(E) BI-DIRECTIONALSERVICE POINT ANDUTILITY METERING1-PHASE, 240VL1L2NEXISTING GROUNDINGELECTRODE SYSTEML2L1L2L1GL2L1L2L1L2L1L2L1L1L2N(E) MAIN BREAKER200A/2P, 240VN(E) MAIN SERVICEDISCONNECT/MAIN DISTRIBUTIONPANEL,200A RATED, 240VSUPPLY SIDE CONNECTION USINGINSULATION PIERCING OR POLARISTAPS PER NEC 705.12(A)L2L1L2L1NNGGL2L1NGL2L1NG(N) SINGLEBREAKER ENCLOSURE,TAP BOX,60 RATED, 240V,WITH 40A BREAKER(INTERTIOR)(DISCONNECT 1 OF 2)(N) ALTERNATIVE POWERSOURCE /AC DISCONNECT/RAPID SHUTDOWN:240V,60AMP RATED,NEMA 3R, UL LISTED LOCKABLE & NON FUSIBLE(EXTERIOR)(DISCONNECT 2 OF 2)(2) 10/2 ROMEX RUN IN ATTICOR(2) #10 AWG THWN-2-RED(2) #10 AWG THWN-2-BLACKEGC #6 AWG THWN-2 GNDIN 1" PVC, IMC, RMC, FMC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT OR ENTCONDUIT RUN REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947 ELECTRICAL CALCULATIONELECTRICAL NOTES1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELEDFOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR 75DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALLBE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TOTHE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICALEQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES ANDSTANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARENOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED ANDREADILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHTRESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FORUSE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).17.THIS SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN OF PVCONDUCTORS IN COMPLIANCE WITH NEC 690.12.18.LABELING IN COMPLIANCE WITH NEC 690.12 AND 690.56(C) IS SHOWNON SHEET E-03.19.ALL CONDUITS TO BE INSTALLED A MIN OF 7/8" ABOVE THE ROOFSURFACE.WIRING CALCULATIONSI ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICALCOMPONENTS ARE DESIGNED AND APPROVED USINGTHE STANDARDS CONTAINED IN THE MOST RECENTVERSION OF THE FLORIDA BUILDING CODE. FBC 107,THE NEC 2017, AND THOSE SET FORTH BY THEFLORIDA SOLAR ENERGY CENTER CERTIFICATION. UMMDPCBACDTBREVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEE-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947SYSTEM LABELINGRAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECT(PER CODE: NEC 690.56(C)(3))WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))WARNINGPOWER SOURCE OUTPUT CONNECTION DONOT RELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!TURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSAC DISCONNECTPHOTOVOLTAICSYSTEM MICROINVERTERSLOCATED UNDER EACHPV MODULE INROOF TOP ARRAYAC COMBINER BOXLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)LABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)LABEL LOCATION:INVERTER(PER CODE: NEC 690.52)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)NOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC 690.52)DATA PER PANELLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.54)PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 26.6 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTS8.250 kW SOLARDISCONNECT LOCATEDLABEL LOCATION:MAIN SERVICE DISCONNECT / MAIN DISTRIBUTION PANEL, PV DISCONNECTLOCATED NO MORE THAN 3FT (1M) FROM THE SERVICE DISCONNECT(TEXT HEIGHT SHOULD BE A MINIMUM OF 3/8")(PER CODE: NEC 690.56(B), NEC 705.10, NFPA 1, 11.12.2.1)CAUTION!POWER TO THIS BUILDINGSUPPLIED FROM MULTIPLE SOURCES EMERGENCY RESPONDER:THIS SOLAR PV SYSTEM IS EQUIPPEDWITH RAPID SHUTDOWN.TURN RAPID SHUTDOWN SWITCH TO THE ''OFF''POSITION TO SHUTDOWN ENTIRE PV SYSTEMSOLAR CONNECTIONLINE SIDE TAPLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(A))ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE VISIBLE, REFLECTIVE AND SUITABLE FORTHE ENVIRONMENT WHERE IT IS INSTALLED [NFPA 1, 11.12.2.1]· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]1103 N 37TH ST, FORT PIERCE, FL 34947LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 1204.5.1(E) MAIN SERVICE DISCONNECT/MAIN DISTRIBUTION PANELSERVICE POINT ANDUTILITY METERING ENPHASE IQ COMBINER BOXPV SOLAR ARRAYON ROOFALTERNATIVE POWER SOURCEAC DISCONNECT/RAPID SHUTDOWN(DISCONNECT 2 OF 2)TAP BOX (DISCONNECT 1 OF 2) REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-01CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-02CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-03CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-04CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-05CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-06CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-07CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947DATA SHEET REVSHEET NAMESHEET SIZESHEET NUMBERKELLY-HOLMES RESIDENCE PROJECT INSTALLERSignature with SealANSI B11" X 17"DATEDESCRIPTIONREVISIONSPROJECT NAMEDS-08CASTILLO ENGINEERINGSERVICES, LLCCOA # 28345620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1103 N 37TH ST, FORT PIERCE, FL 34947DATA SHEET