Loading...
HomeMy WebLinkAboutLeeth Residence - Wind Load Letter eSEALrepared for Clear Choice Windows and Glass Calculations by Seaside Engineers Project: Leeth Residence Certificate of Authorization No. 32048 Location: 3200 N HWY A1A #410 4265 60th Court Fort Pierce, Florida Vero Beach, Florida 32967 Project ID:(722) 202‐8008            info@seasideengineers.com Date:  1/7/2022 www.seasideengineers.com Design Information Risk Category II Windspeed 161 mph Exposure D Int. Press. Coef., GCpi(+/‐)0.18 Enclosed a 5.00 feet ID Area  (sqft) Zone Florida  Product  Approval # or  NOA Manufacturer Model 1 9.2 4 20‐0401.05 PGT 5460 46.4 ‐52.8 50.0 ‐100.0 2 17.9 4 20‐0401.05 PGT 5460 46.4 ‐52.8 50.0 ‐100.0 3 12.2 4 20‐0401.05 PGT 5460 46.4 ‐52.8 50.0 ‐100.0 4 12.2 4 20‐0401.05 PGT 5460 46.4 ‐52.8 50.0 ‐100.0 5 17.9 4 20‐0401.04 PGT 5400 46.4 ‐52.8 50.0 ‐65.0 Select the appropriate fastener size and spacing using the pre‐engineered attachment schedule for the Florida Approved Product(s) or NOA used on this job. The contractor is  responsible to ensure the use of the proper material, reinforcement, components, etc. to meet the indicated pressure per the product approval engineering document. The contractor  is responsible to verify the component is in the appropriate zone using the "a" dimension shown above and diagrams shown below. The building pressures are calculated using the  Allowable Stress Design. Contact Seaside Engineers immediately if the substrate at the attachment locations appears to have deterioration, abnormalities, damage, or other conditions  resulting in questionable integrity. Component & Cladding Wind Loads Building Design  Pressure (PSF) Product Design  Pressure (PSF)Opening Description DH Window DH Window DH Window DH Window SH Window