HomeMy WebLinkAboutNOA ALUMINUM SINGLE HUNG WINDOW NOA No. 20-0401.12
Expiration Date: August 23, 2023
Approval Date: July 30, 2020
Page 1
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
PGT Industries, Inc.
1070 Technology Drive
North Venice, FL 34275
SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the
right to revoke this acceptance if it is determined by Miami–Dade County Product Control Section that this
product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Series “SH7600A” Aluminum Single Hung Window – N.I.
APPROVAL DOCUMENT: Drawing No. 7600NOA-1, titled “Aluminum Single Hung Install (NI)”, sheets
1 through 12 of 12, dated 04/01/18, with revision A dated 03/11/20, prepared by manufacturer, signed and
sealed by Anthony Lynn Miller, P.E., bearing the Miami-Dade County Product Control Revision stamp with
the Notice of Acceptance number and approval date by the Miami-Dade County Product Control Section.
MISSILE IMPACT RATING: None
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami-Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 18-0430.07 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as
well as approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 20-0401.12
Expiration Date: August 23, 2023
Approval Date: July 30, 2020
E - 1
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. Submitted under NOA # 18-0430.07
A. DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No. 7600NOA-1, titled “Aluminum Single Hung Install (NI), sheets 1 through
12 of 12, dated 04/01/18, prepared by manufacturer, signed and sealed by Anthony Lynn
Miller, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94
along with marked-up drawings and installation diagram of an aluminum single hung
window, prepared by Fenestration Testing Laboratory, Inc., Test Report No.
FTL-18-7835.1, dated 04/03/18, signed and sealed by Idalmis Ortega, P.E.
2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94
along with marked-up drawings and installation diagram of an aluminum single hung
window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.
FTL-18-7835.2, dated 05/04/18, signed and sealed by Idalmis Ortega, P.E.
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 6th
Edition (2017), dated 04/23/18, prepared by manufacturer, signed and sealed by
Anthony Lynn Miller, P.E.
2. Glazing complies with ASTM E1300-09
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 20-0401.12
Expiration Date: August 23, 2023
Approval Date: July 30, 2020
E - 2
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
D. QUALITY ASSURANCE
1. Miami-Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of conformance to FBC 6th Edition (2017), dated April 24, 2018, issued
by manufacturer, signed and sealed by Anthony Lynn Miller, P.E.
2. Statement letter of no financial interest, dated April 24, 2018, issued by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E.
3. Proposal No. 18-0005R issued by the Product Control Section, dated 01/16/18, signed
by Manuel Perez, P.E
G. OTHERS
1. None.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 20-0401.12
Expiration Date: August 23, 2023
Approval Date: July 30, 2020
E - 3
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. New Evidence Submitted
A. DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No. 7600NOA-1, titled “Aluminum Single Hung Install (NI)”, sheets 1 through 12 of
12, dated 04/01/18, with revision A dated 03/11/20, prepared by manufacturer, signed and
sealed by Anthony Lynn Miller, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per ASTM F588 and TAS 202-94
along with marked-up drawings and installation diagram of all PGT Industries, Inc.
representative units listed below and tested to qualify Dowsil 791 and Dowsil 983
silicones, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.:
FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14
FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal)
FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal)
FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and
FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal)
dated 07/13/20, all signed and sealed by Idalmis Ortega, P.E
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 6th Edition
(2017) and FBC 7th Edition (2020), dated 03/10/20, prepared by manufacturer, signed and
sealed by Anthony Lynn Miller, P.E.
D. QUALITY ASSURANCE
1. Miami- Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. None.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 20-0401.12
Expiration Date: August 23, 2023
Approval Date: July 30, 2020
E - 4
PGT Industries, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 6th Edition (2017) and FBC 7th
Edition (2020), dated March 10, 2020, issued by manufacturer, signed and sealed by Anthony
Lynn Miller, P.E.
2. Statement letter of no financial interest, dated March 10, 2020, issued by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E.
3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10,
2020, signed by Ishaq Chanda, P.E.
G. OTHERS
1. Notice of Acceptance No. 18-0430.07, issued to PGT Industries, Inc. for their “Series
“SH7600A” Aluminum Single Hung Window – N.I.” approved on 08/23/18 and
expiring on 08/23/23.